RHV3 RECOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
Features
- bullet points (Productmanager) RHV3 DC/DC Converter
3 Watt
- 12.5kVAC/1 minute isolation
- Compact SIP16 case with >30mm pin separation
- Low 4pF max. isolation capacitance
- Wide operating temper ature range from -40°C to +80°C at full load
- Efficiency up to 81%
Description
The RHV3 is a DC/DC converter with exceptionally high 20kVDC (12.5KVAC/1 minute) isolation in a compact SIP16 case. Input voltages can be 5, 12 or 24VDC and outputs 5V, 12V, 24V, ±5V or ±12V. The operating temperature is -40°C to +80°C without derating. Applications include high vacuum monitoring, X-Ray equipment, HVAC dust extraction systems and other high voltage industrial applications where a very high isolation remote power supply is required. Selection Guide Part nom. Input Output Output Efficiency max. Capacitive Number Voltage Voltage Curr ent typ. (1) Load (2) [VDC] [VDC] [mA] [%] [µF] RHV3-0505S/R20 5 5 600 76 1000 RHV3-0512S/R20 5 12 250 78 330 RHV3-0524S/R20 5 24 125 80 100 RHV3-1205S/R20 12 5 600 78 1000 RHV3-1212S/R20 12 12 250 79 330 RHV3-1224S/R20 12 24 125 80 100 RHV3-2405S/R20 24 5 600 80 1000 RHV3-2412S/R20 24 12 250 80 330 RHV3-2424S/R20 24 24 125 81 100 RHV3-0505D/R20 5 ±5 ±300 78 ±680 RHV3-0512D/R20 5 ±12 ±125 80 ±150 RHV3-1205D/R20 12 ±5 ±300 78 ±680 RHV3-1212D/R20 12 ±12 ±125 81 ±150 RHV3-2405D/R20 24 ±5 ±300 80 ±680 RHV3-2412D/R20 24 ±12 ±125 80 ±150 Notes: Note1: Efficiency is tested a t nominal input and full load at +25°C ambient Note2: The capacitive load is tested at minimum input and constant resistive load Model Numbering Isolation Voltage Single or Dual Output Output Power nom. Input Voltage Output Voltage RHV3-__ __ /R20 IEC/EN62368-1 certified IEC/EN61010-1 certified
www.recom-power.com REV.: 0/2019 ECO-2 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RHV3 Series BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter capacitors Input Voltage Range ±10% Minimum Load 0% Internal Operating Frequency 20kHz 45kHz Output Ripple and Noise (3) 20MHz BW 150mVp-p 200mVp-p Notes: Note3: Measurements are made with a 0.1µF MLCC across output (low ESR) 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] Efficiency vs. Load RHV3-1205S/R20RHV3-0505D/R20 RHV3-2424S/R20RHV3-0505S/R20
www.recom-power.com REV.: 0/2019 ECO-3 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RHV3 Series REGULATIONS Parameter Condition Value Output Accuracy ±5.0% max. Line Regulation low line to high line, full load ±1.2% of 1.0% Vin typ. Load Regulation (4) 10% to 100% load 5Vin 15.0% max. others 10.0% max. Cross Regulation 10% to 100% load ±7.5% typ. Notes: Note4: Opera tion below 10% load will not harm the converter, but specifications may not be met +15% +12.5% Vnom +5% +0.5% -5% Output Voltage [%] 10 50 100 Output Load [%] Typical Load Line +10% +8% Vnom +5% -1.5% -5% Output Voltage [%] 10 50 100 Output Load [%] Typical Load Line +10% +6.6% Vnom +5% -1.5% -5% Output Voltage [%] 10 50 100 Output Load [%] Typical Load Line +6.5% +10% Vnom +5% -5% Output Voltage [%] 10 50 100 Output Load [%] Typical Load Line Tolerance Envelope RHV3-0505S/R20 +15% +12% Vnom +5% +1.5% -5% Output Voltage [%] 10 50 100 Output Load [%] Typical Load Line +10% +15% Vnom +5% +1% -5% Output Voltage [%] 10 50 100 Output Load [%] Typical Load Line RHV3-0505D/R20 RHV3-1205S/R20 RHV3-0524S/R20 RHV3-2412D/R20 RHV3-2424S/R20
www.recom-power.com REV.: 0/2019 ECO-4 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RHV3 Series PROTECTIONS Parameter Type Value Isolation Voltage (5) I/P to O/P tested for 1 second tested for 1 minute 20kVDC 12.5kVAC Isolation Resistance 15GW min. Isolation Capacitance 3.5pF typ./ 4pF max. Insulation Grade reinforced Notes: Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note6: Refer to local safety regulations if input over -current protection is also required. Recommended fuse: slow blow type ENVIRONMENTAL Parameter Condition Value Operating Temperature Range without derating @ natural convection 0.1m/s (see graph) -40°C to +80°C Maximum Case Temperature +105°C Temperature Coefficient 0.02%/K max. Thermal Impedance 12K/W typ. Operating Altitude 5000m Operating Humidity non-condensing 5% - 95% RH max. Pollution Degree PD2 Vibration MIL-STD-202G MTBF according to MIL-HDBK-217F,G.B. +25°C +80°C 13400 x 103 hours 3600 x 103 hours Derating Graph (@ Chamber and natural convection 0.1m/s) -40 -20 0 20 40 70 60-30 -10 10 30 50 80 90 110 100 100 Output Load [%] Ambient Temperature [°C]
www.recom-power.com REV.: 0/2019 ECO-5 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RHV3 Series SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Audio/Video, information and communication technology equipment - Part1: Safety requirements WD-SE-R-190305-A0 IEC62368-1:2014 2nd Edition EN62368-1:2014+AC:2015 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements WD-SE-R-190305-B0 IEC61010:2010 EN61010:2010 RoHS 2 RoHS 2011/65/EU + AM2015/863 EMC Compliance Condition Standard / Criterion Electromagnetic compatibility of multimedia equipment – Emission Requirements refer to “EMC Filtering Suggestions” EN55032, Class B Information technology equipment - Immunity characteristics - Limits and methods of measurement EN55024:2010 + A1:2015 ESD Electrostatic discharge immunity test Air: ±2, 4, 8kV, Contact: ±2, 4kV IEC61000-4-2:2009, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 3V/m IEC61000-4-3:2006+A2:2010, Criteria A Fast Transient and Burst Immunity DC Power Port: ±0.5kV, ±1kV IEC61000-4-4:2012, Criteria A Surge Immunity DC Power (Output) Port: ±0.5kV IEC61000-4-5:2014+A1:2017, Criteria A Immunity to conducted disturbances, induced by radio-frequency fields DC Power (Output) Port: 3V IEC61000-4-6:2013+C1:2015, Criteria A Power Magnetic Field Immunity 50Hz, 1A/m IEC61000-4-8:2010, Criteria A +Vin -Vin +Vout -Vout -Vin +Vin -Vout +Vout +Vin -Vin +Vout -Vout -Vin +Vin -Vout +Vout ComCom EMC Filtering Suggestions according to EN55032 Single Output Dual Output DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case PCB potting black plastic, (UL94V-0) FR4, (UL94V-0) epoxy, (UL94V-0) Package Dimension (LxWxH) 45.0 x 15.0 x 17.0mm Weight 19.7g typ. continued on next page Component List Class B nom. Input Voltage C1 L1 5VDC, 12VDC, 24VDC 10µF, 50VDC MLCC 18µH choke RLS-226
www.recom-power.com REV.: 0/2019 ECO-6 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RHV3 Series 2.54 2.541 2 14 1615 embossed logo Bottom View 0.25±0.100.5±0.10 45.0 12 x 2.54 = 30.48 15.0 5.00 17.0 Top View 1.50 Marking 3.45 0.50 1 2 14 16 15 Pinning Information Pin # Single Dual 1 +Vin +Vin 2 -Vin -Vin 14 -Vout -Vout 15 no pin Com 16 +Vout +Vout Tolerance: xx.x= ±0.5mm xx.xx= ±0.25mm Recommended Footprint Details Dimension Drawing (mm) PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 26.9 x 17.9mm Packaging Quantity 10pcs Storage Temperature Range -55°C to +125°C Storage Humidity non-condensing 5% - 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.