RFL100 VAISALA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

Features

  • Industry-leading measurement precision
  • Interchangeable high-accuracy probes for T, RH, and CO2
  • 30-day memory buffer
  • Typical battery life of 18 months in RH and T measurement
  • Uses standard alkaline batteries
  • Probe calibrations are traceable to SI units through national metrology institutes or accredited calibration laboratories
  • Cost-effective alternative to chart recorders RFL100 Data Logger uses Vaisala’s proprietary VaiNet wireless technology. It can be used to monitor temperature (T), relative humidity (RH), and carbon dioxide level (CO2) in a wide range of environments. Suitable applications include warehouses, production areas, cleanrooms, laboratories, incubators, fridges, cold storage areas, and freezers down to −196 °C (approx. −320 °F). VaiNet wireless RFL100 connects wirelessly to Vaisala viewLinc Monitoring System, which provides real-time trends, alarms, and historical reporting. VaiNet wireless technology provides a robust wireless signal that is extremely reliable over long distances and in complex, obstructed conditions. This wireless technology allows the data logger’s signal to travel over 100 m (approx. 330 ft) indoors without the aid of signal amplifiers or repeaters. Wireless communications are encrypted to ensure data integrity and security. Measurements are updated and stored every 60 seconds, and sent from the data logger every 4 minutes. In case of temporary network disruptions, the data logger can record up to 30 days of measurements that are automatically transmitted to the viewLinc Enterprise Server software when communications are restored. Recorded data can also be downloaded directly from RFL100 through the USB port. Versatility and convenience RFL100 requires no startup configuration, and the included mounting bracket supports several installation methods. Detailed custom display shows the latest measurement results, alarm and battery status, and signal strength of the current access point connection. The housing is classified IP54 to protect the device from dust and cleaning. RFL100 is powered by two standard AA size 1.5 V batteries (LR6 alkaline or FR6 lithium) for 18 months of operation at approximately 20 °C (68 °F) in RH and T measurement. When fresh batteries are inserted during yearly calibration, battery replacement between calibrations is not needed. External power is required for CO2 measurement, with the batteries serving as backup in case the external power becomes unavailable. Interchangeable probes The probes are detachable and easy to switch out for calibration. viewLinc Enterprise Server detects the changed probe information automatically and maintains accurate and complete historical records. RH and T probes use Vaisala HUMICAPâ humidity sensors and platinum temperature sensors (Pt100 and Pt1000 type) for superior stability. Probes can be integrated with the RFL100 housing or connected using a cable. CO2 measurement is provided by the GMP251 probe that uses Vaisala’s patented, latest-generation CARBOCAPâ technology with exceptional stability. The probe automatically compensates the CO2 measurement according to ambient temperature.

Probe Description 1) Installation notes HMP110, HMP110T, and HMP110REF Humidity and temperature probe for measurement in demanding conditions. Robust stainless steel construction. Temperature-only version HMP110T available. Plastic grid filter provides the fastest response time. For added protection, select the membrane filter, the PTFE filter, or the stainless steel sintered filter. Measurement temperature range −40 … +80 °C (−40 … +176 °F). Suitable for measurement inside chambers, incubators, fridges, and freezers. Versatile mounting options using accessories. Must be connected to RFL100 using a cable. A constant output probe version HMP110REF is also available for validating installations. The constant output version does not measure – instead, it outputs unchanging humidity and temperature values. HMP115 and HMP115T Humidity and temperature probe for general purpose measurement. Temperature-only version HMP115T available. Plastic grid filter provides the fastest response time. For added protection, select the membrane filter or the PTFE filter. Measurement temperature range −40 … +60 °C (−40 … +140 °F). Ideal choice for ambient measurement. Can be integrated with the RFL100 housing or connected using a cable. TMP115 Temperature probe for measurement in a wide range of conditions. Available as 50 cm (1 ft 7.7 in) and 3 m (9.8 ft) long versions. Length includes the probe body and sensor tip. Measurement temperature range −196 … +90 °C (−320 … +194 °F). Operating temperature range of the probe body is Suitable for measurement inside chambers, fridges, and freezers. Can be integrated with the RFL100 housing or connected using a cable. Sensor tip withstands immersion in glycol and liquid nitrogen. Use the thermal dampener block accessory (item code 236310SP) to add thermal mass to the sensor tip. GMP251 Carbon dioxide probe for %-level measurements. Designed for use in demanding applications such as life science incubators. Measurement temperature range −40 … +60 °C (−40 … +140 °F). When ordered with the RFL100 data logger, the probe is delivered with a mounting kit that includes a probe holder designed for use with GMP251 and the other supported probes. The kit also includes a magnetic holder for the Probe Splitter M8/M12 accessory. Must be connected using the Probe Splitter M8/M12 accessory. Any one of the other supported probes can be connected at the same time in the M8 connector of the probe splitter. Requires use of external power supply due to power consumption. Data logger batteries provide a backup in case the external power is not available. Logged temperature data is limited to range −40 … +60 °C (−40 … +140 °F) when GMP251 is connected. 1) See probe datasheets for detailed probe specifications.

Accessory 1) Item code Probe cable for RFL100, 1.5 m CBL210555-1M5SP Probe cable for RFL100, 3 m CBL210555-3MSP Probe cable for RFL100, 10 m CBL210555-10MSP Flat cable for RFL100, 3 m CBL210647SP Probe holder (5 pcs) for Ø 12 mm probes ASM213382SP CO2 probe mounting kit ASM214253SP Probe splitter M8 (for connecting two T probes) CBL210834SP Probe splitter M8/M12 (for connecting a CO2 probe) CBL211050SP 1 m high-temperature cable M12 (for CO2 probe) 2) 271038SP 1 m high-temperature cable M8 (for RH/T probe in CO2 applications) 2) 271039SP Universal power supply (100–240 V AC / 5 V DC) with micro-USB connector ASM214178SP 1) See probe datasheets for probe-specific accessories. remain inside an incubator during a typical heat sterilization cycle. Due to heat conduction, leave half of the cable in ambient temperature when installed. RFL100 with two TMP115 probes (left) and with GMP251 and HMP110 probes (right)

Networking standards Vaisala VaiNet Modulation Chirp spread spectrum modulation Output power ≤ 13 dBm (≤ 20 mW) Antenna Internal Typical range (indoors) At least 100 m (approx. 330 ft) Range with line-of-sight Over 500 m (1640 ft) Frequency bands 500 MHz, 868 MHz, 915 MHz,

920 MHz, and 922 MHz

Sample capacity 30 days (43200 samples per channel) Memory type Non-volatile EEPROM Memory mode Ring buffer (FIFO) Sampling rate One sample / channel / minute (non- changeable) General Compatible probes GMP251, HMP110, HMP110T, HMP115, HMP115T, TMP115 Batteries 2 × AA sized, 1.5 V (LR6 or FR6) Operation time on battery power at 20 °C (68 °F) RH and T measurement in any probe combination 18 months CO2 measurement Typically 12 hours with lithium batteries Compatibility requirements Item Required minimum version(s) viewLinc version viewLinc Enterprise Server 5.0 Dual T probe support using Probe Splitter M8 accessory

  • RFL100 firmware 1.2.0
  • AP10 firmware 3.0
  • viewLinc Enterprise Server 5.0.2 CO2 measurement using Probe Splitter M8/M12 accessory and external power
  • RFL100 firmware 1.4.0
  • RFL100 hardware manufactured after July 2021
  • AP10 firmware 4.0 and hardware revision G
  • viewLinc Enterprise Server 5.1 Operating environment Storage temperature −40 … +60 °C (−40 … +140 °F) Operating humidity 0 … 100 %RH, non‑ condensing IP rating IP54 IP rating with external power supply IP20 Operating temperature 1) with alkaline batteries +2 … +60 °C (+35.6 … +140 °F) with lithium batteries −20 … +60 °C (−4 … +140 °F) with external power supply 0 … +60 °C (+32 … +140 °F) 1) Verify operating temperature specification when using third party batteries and power supplies. Compliance EMC compatibility IEC/EN 61326‑ 1, industrial environment Electrical safety IEC/EN 61010‑ 1

500 MHz model

Radio standards and approvals China MIIT 工业和信息化部公告 2019 年第 52号 Compliance marks China RoHS

868 MHz model

EU directives and regulations RoHS Directive (2011/65/EU) amended by 2015/863 Radio Equipment Directive, RED (2014/53/EU) Radio standards and approvals ETSI EN 300 220-2 ETSI EN 301 489-1 ICASA No: TA 2020-7761 IMDA No: DB105576 TRA No: 67584/18 Serbia: И005 21 Compliance marks AAA, CE, ICASA, UKCA

915 MHz model

Radio standards and approvals Anatel ID: 04761-19-12322 AS/NZS 4268 FCC ID: 2AO39-RFL100A IC ID: 23830-RFL100A NOM ID: 1901C00493 Compliance marks ANATEL, NOM, NYCE, RCM

920 MHz model

Radio standards and approvals MIC ID: 012-200007 Compliance marks GITEKI

922 MHz model

Radio standards and approvals NCC ID: CCAP21LP1240T3 Compliance marks NCC

Mounting methods Screws, cable ties, hook, or magnetic mounting bracket (optional accessory) Probe interface 4-pin female M8 connector Service port USB 2.0 with micro-USB connector Dimensions (H × W × D) with HMP115 probe Without mounting bracket 158 × 62 × 31 mm (6.22 × 2.4 × 1.22 in) With mounting bracket 186 × 68 × 36.5 mm Weight With batteries (2 pcs alkaline) and HMP115 probe 190 g (6.7 oz) With batteries (2 pcs alkaline), HMP115 probe, and magnetic mounting bracket 254 g (8.96 oz) Materials Housing PC/ABS blend Display window PMMA (acrylic) Sealings TPE Requirements for external power supply Output voltage 5 V DC Output power Min. 1 W Output connector Micro-USB Certifications and approvals • Certified to IEC 62368-1

  • Approved for use in your country 68 [2.68] 186 [7.32] 36.5 [1.44] Ø 12 [0.47] mm [in] RFL100 dimensions with HMP115 probe Published by Vaisala | B211595EN-N © Vaisala 2023 All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. Any reproduction, transfer, distribution or storage of information contained in this document is strictly prohibited. All specifications — technical included — are subject to change without notice. www.vaisala.com