HMD60 VAISALA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

Features

  • Measurement accuracy up to
  • 4 … 20 mA analog outputs: HMD62 (RH and T) and TMD62 (T- only)
  • 0 … 10 V analog outputs: HMD65 (RH and T)
  • BACnet MS/TP and Modbus RTU: HMD65
  • All common humidity parameters available, including RH, dew point, enthalpy, and wet bulb temperature
  • Resistant to chemicals and dust
  • IP66-rated body
  • Traceable calibration certificate
  • Easy field adjustment and output configuration with quick access to electronics also when installed
  • Compatible with Vaisala Insight PC software The duct mounted HMD60 series HUMICAPâ transmitters HMD62, TMD62, and HMD65 are designed for light industrial applications and demanding HVAC applications such as museums, cleanrooms, and laboratories. Analog or Digital Output with

3 Transmitter Options

HMD60 series transmitter options:

  • HMD62: RH and T measurement, 4 … 20 mA analog output
  • TMD62: T-only transmitter, 4 … 20 mA analog output
  • HMD65: RH and T measurement, 0 … 10 V analog output, Modbus RTU, and BACnet MS/TP Robust Design, Stability, and Reliability The all-metal body is suitable for building sites and industrial settings. HMD60 series transmitters provide state- of-the-art stability and environmental resistance, thanks to the Vaisala HUMICAPâ R2 sensor. For applications where hydrogen peroxide disinfection is used, the HUMICAPâ 180V catalytic sensor option provides improved stability during H2O2 exposure. Traceable Accuracy HMD60 series transmitters are always delivered with a traceable (ISO9001) calibration certificate. Upon request, accredited (ISO17025) calibration certificates can also be provided. Field Configurable Outputs The analog HMD62 and TMD62 transmitter models use floating 4 … 20 mA loop powered outputs. The HMD65 model has two 0 … 10 V outputs in addition to BACnet MS/TP and Modbus RTU interfaces (RS-485). The analog outputs are field configurable with easy humidity parameter selection using DIP switches. For special scaling and other additional configuration and adjustment options, you can use the convenient Vaisala Insight PC software for Windowsâ (see www.vaisala.com/insight). When required, HMD60 series transmitters can also be intuitively field adjusted using trimmers or with the Vaisala HM70 handheld meter.

Relative Humidity Measurement Performance Humidity Sensor Options HUMICAPâ R2 Latest generation industrial sensor with improved corrosion resistance HUMICAPâ 180V Humidity sensor with a catalytic surface for processes with H2O2 Measurement range 0 ... 100 %RH Stability ±0.5 %RH/year in typical HVAC

applications

Accuracy at 0 … +40 °C (+32 … +104 °F) 1) 90 … 100 %RH ±3.5 %RH Factory calibration uncertainty ±1.0 %RH Start-up and Response Time Start-up time at +20 °C (+68 °F) 8 s Response time (T63) at +20 °C (+68 °F) 15 s Calculated Humidity Parameters (Default Analog Output Scale) Dew point - Absolute humidity 0 … 300 g/m3 (0 … 131.1 gr/ft3) Btu/lb) Mixing ratio 0 … 600 g/kg (0 … 4200 gr/lb) 1) Including non-linearity, hysteresis, and repeatability 2) With HUMICAPâ 180V sensor, accuracy is not specified below -20 °C (-4 °F) operating temperature Temperature Measurement Performance Temperature sensor Pt1000 RTD Class F 0.1 IEC 60751 Default analog output scale -20 … +80 °C (-4 … +176 °F) Accuracy at +20 °C (+68 °F) ±0.1 °C (0.18 °F) Temperature dependence ±0.005 °C/°C Factory calibration uncertainty ±0.1 °C (0.18 °F) Response time (T63) with free convection 8 min Analog Output Performance Accuracy at +20 °C (68 °F): ±0.01 mA (HMD62 and TMD62) ±5 mV (HMD65) Temperature dependence ±0.0008 mA/°C (HMD62 and TMD62) ±0.2 mV/°C (HMD65) Operating Environment Maximum flow speed 50 m/s with sintered filter Electromagnetic compatibility EN61326-1, Industrial Environment Inputs and Outputs Power supply input HMD62 and TMD62: 10 ... 35 VDC (RL = 0 Ω) 20 ... 35 VDC (RL = 600 Ω) HMD65: 15 … 35 VDC 16 … 24 VAC Power consumption (HMD65) 1.0 W (typical, for both AC and DC) Analog outputs TMD62: 1 × T output 4 ... 20 mA HMD62: 1 × RH output 4 … 20 mA, 1 × T output 4 ... 20 mA 1) HMD65: 1 × RH output 0 … 10 V, 1 × T output 0 … 10 V 1) (load resistance: 10 kΩ min.) Digital output (RS-485) HMD65: Isolated, supports Modbus RTU and BACnet MS/TP protocols BACnet MS/TP Address range: 0 … 127 (master mode only) Modbus RTU Address range: 1 … 247 Service port M8 4-pin male connector:

  • MI70 handheld indicator (requires cable 219980SP)
  • Vaisala Insight PC software 2) (requires USB cable 219690) 1) Calculated output parameters for HMD62 and HMD65 include T d, Tdf, A, X, Tw, and H. 2) Vaisala Insight software for Windows â available at www.vaisala.com/insight. Spare Parts and Accessories USB cable for PC operation (Vaisala Insight software) 219690 Connection cable for HM70 (MI70) handheld meter 219980SP Membrane filter ASM212652SP Sintered filter HM46670SP Sintered teflon filter DRW244938SP Conduit fitting and O-ring (M16×1.5 / NPT1/2") 210675SP Mechanical Specification Housing material Cast aluminum Probe material Stainless steel IP rating IP66 (NEMA 4X) Weight 511 g (18 oz) 101 [3.97] 82[3.23] 82 [3.23] 101 [3.97] 299 [11.77] 101 [3.97] mm 49 [1.92] 100 [3.94] 149 [5.87] 299 [11.77] 149 [5.87] HMD60 Dimensions (Long and Short Probe Options)

Model Measurement Parameters Outputs and Scaling HMD62 Humidity and Temperature 2 analog outputs, 4 … 20 mA TMD62 Temperature 1 analog output, 4 … 20 mA HMD65 Humidity and Temperature 2 analog outputs, 0 … 10 V Digital output: B ACnet MS/TP, Modbus RTU HMD60 Humidity and Temperature Configurable outputs and scale , short probe option TMD60 Temperature 1 analog output (4 … 20 mA, c onfigurable scale), short probe option Published by Vaisala | B211718EN-D © Vaisala Oyj 2019 All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. Any reproduction, transfer, distribution or storage of information contained in this document is strictly prohibited. All specifications — technical included — are subject to change without notice. www.vaisala.com