Features

  • Universal AC Input (85-264VAC)
  • Long 7 Year Warranty
  • Protections: SCP, OVP, OCP, OTP
  • 100% Full Load burn-in test
  • DC OK Indicator LED with Relay Contacts
  • cooling by free air convection, 5000m operation
  • UL, CSA & CE certified with CB Report BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Input Voltage Range all operating conditions 85VAC 264VAC max. Input Voltage max. 1 second 300VAC 375VDC Output Voltage Adjustment (Factory Setting) (1) 12Vout 24Vout 12-15VDC (12V±5%) 24-28VDC (24V±5%) Input Current full load, 115VAC full load, 230VAC 1.35A 0.75A Inrush Current cold start at 25°C, 115VAC cold start at 25°C, 230VAC 40A 60A No Load Power Consumption standard (with Relay) /NR option (no Relay) <1000mW <500mW Start Up time cold start, 230VAC 500ms 1000ms Rise time cold start, 230VAC 20ms Hold-up time full load, 115VAC full load, 230VAC 20ms 50ms Input Frequency Range 47Hz 63Hz Operating Frequency Range 65kHz Efficiency see Selection Guide Output Ripple and Noise (2) 12Vout 24Vout 60mVp-p 75mVp-p Over Load all operating conditions 140% for 5 seconds max. continued on next page Specifications (measured at TA= 25°C, 230VAC, full load and after warm up)

Description

This DIN-rail mounted power supply uses high reliability components to give a long, trouble-free life.The power supply can be end mounted to save space or side mounted for use in low-profile cabinets. Relay contacts simplify DC OK monitoring and the units can deliver 60W start-up power. The REDIN series is fully certified for industrial use and carries a 7-year warranty. Selection Guide Part Input Output Output Rated Efficiency Max. Number Voltage Range Voltage Trimming Voltage Current typ. Capacitive Load (VAC) (VDC) (VDC) (A) (%) (µF) REDIN45-12 85-264 12 12-15 3.75 85 18800 REDIN45-24 85-264 24 24-28 1.875 86 4700 E224736

45 Watt

CSA C22.2 No. 60950-1-07 Certified Notes: Note1: For more details refer to Vadj. Derating Graph Note2: Ripple and Noise are measured at 20MHz bandwidth by using a 12” twisted pair-wire terminated with 0.1µF & 47µF parallel capacitor.

PA-2 REV.: 3/2016 www.recom-power.com Efficiency vs. Load Vadj. Derating Specifications (measured at TA= 25°C, 230VAC, full load and after warm up) PROTECTION Parameter Condition Value Input Fuse T2.5A, slow blow type Short Circuit Protection (SCP) Hiccup auto-recovery after fault condition Over Voltage Protection (OVP) 12Vout 24Vout 18VDC max., shut-down latch-off o/p voltage, re-power on to recover 35VDC max., shut-down latch-off o/p voltage, re-power on to recover Over Current Protection (OCP) 150% typ., auto-recovery after fault condition Over Temperature Protection (OTP) detect on inside ambient 105°C±5%, shut-down latch-off o/p voltage, re-power on to recover Isolation Voltage I/P to O/P I/P to FG O/P to FG 3.75kVAC / 1 minute 1.88kVAC / 1 minute 0.5kVAC / 1 minute Isolation Resistance 500VDC, 70% RH, I/P to O/P; I/P to FG; O/P to FG 100MW min. Leakage Current 240VAC <1.0mA Power OK LED Relay Contacts LED/Relay 1A, 30VDC / 120VAC ON if Vout = 11-16V (12V) / 22-30V (24V) REGULATION Parameter Condition Value Line Regulation ±0.1 typ. / ±1% max. Load Regulation ±0.1 typ. / ±1% max. Transient Response (3) Dwell Time Slew Rate 12Vout (step load change: 1.875A - 3.75A) 24Vout (step load change: 0.937A - 1.875A) ±5% typ. ±5% typ. 100Hz & 1kHz 50% duty 0.5A / µs REDIN45 Series REDIN45-12 REDIN45-24 Load (%) Altitude (m) 2000 3000 4000 5000 40 60 80 100 Ta= 35°C Ta= 50°C Load (%) Altitude (m) 2000 3000 4000 5000 40 60 80 100 Ta= 55°C Ta= 40°C Derating: 1.5W / 1000m or 5°C / 1000mDerating: 3W / 1000m or 5°C / 1000m 10-10-20 7030 50 100 Ambient Temperature (°C) 24VDC 12VDC 10-10-20 7030 50 100 Ambient Temperature (°C) Load (%) Load (%) 24VDC 12VDC 1 2 3 3.750 Load (A) Efficiency (%) 85VAC 115VAC 230VAC 264VAC 0.5 1 1.5 1.8750 Load (A) Efficiency (%) 85VAC 115VAC 230VAC 264VAC 5012 (24) 45W max. (28) Vadj. 100 Output Voltage (V) Output Current (%) Notes: Note3: Transient Response + E-CAP loading 3300µF. Other specs with resistive load only.

Operating Temperature Range with derating -20°C to +70°C (see graph) Operating Humidity non-condensing 20% - 90%RH Vibration 10-500Hz 2G, 60min. Shock 3 times each axis 10G / 11ms, along X, Y and Z axis Altitude see derating graph 5000m MTBF (+25°C) MIL-HDBK-217F, 115VAC, 60Hz, 75% load 200 x 10³ hours Design Lifetime (+40°C) 87.6 x 10³ hours PA-3REV.: 3/2016www.recom-power.com Specifications (measured at TA= 25°C, 230VAC, full load and after warm up) REDIN45 Series Derating Graph Typical Characteristics Load (%) Altitude (m) 2000 3000 4000 5000 40 60 80 100 35°C 50°C (45W) Load (%) Altitude (m) 2000 3000 4000 5000 40 60 80 100 35°C 40°C (45W) Vin ≤100VAC Vin >100VAC 10-10-20 7030 50 100 Temperature (°C) 24VDC 12VDC 10-10-20 7030 50 100 Temperature (°C) Load (%) Load (%) 24VDC 12VDC Load (%) Altitude (m) 2000 3000 4000 5000 40 60 80 100 35°C 50°C (45W) Load (%) Altitude (m) 2000 3000 4000 5000 40 60 80 100 35°C 40°C (45W) Vin ≤100VAC Vin >100VAC 10-10-20 7030 50 100 Temperature (°C) 24VDC 12VDC 10-10-20 7030 50 100 Temperature (°C) Load (%) Load (%) 24VDC 12VDC Vin ≤ 100VAC Vin > 100VAC REDIN45-12 REDIN45-24

PA-4 REV.: 3/2016 www.recom-power.com Specifications (measured at TA= 25°C, 230VAC, full load and after warm up) REDIN45 Series DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Case Material UL94V-0 plastic Paclage Dimension (WxHxD) 45.1 x 92.0 x 101.2mm Package Weight 332g continued on next page 7.5±0.2 101.2 92.0 45.1 75±0.3 35±0.1 DIN-RAIL mounting bracket (75mm) included SIDE MOUNTINGEND MOUNTING 18±0.2 1±0.05 25.0 25.0 6.3±0.2 Side Latch Release End Latch Release Front Side Front Side DC OK DC OK DC OK TRIM Tolerance: ±0.5mm FG N L +V -V FG N L +V -V Dimension Drawing (mm) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard UL General Safety CSA General Safety E224736 UL-60950-1, 2nd Edition UL-1310 C22.2 No. 60950-1-07, 2nd Edition Industrial Control Equipment General Use Power Supplies E470721 UL-508 C22.2 No. 107.1 IEC/EN General Safety E224736 IEC/EN-60950-1, 2nd Edition Chinese Safety Standard E224736 GB 4943.1-2011 EMC Compliance Report / Condition Standard / Criterion EMI Standard Report: HA150146 EN-55022, Class B EN-55024, Class B FCC15, Class B ESD Radiated Immunity Fast Transient Surge Conducted Immunity Power frequency magnetic field immunity test Noise Immunity Harmonic Immunity Voltage Flicker ±8kV Contact & Air Discharge 10V/m, 80-3000MHz, 80% AM at 1kHz Level 2 ±2kV / L-N, ±4kV / L, N-FG 10Vrms, 0.15-80MHz, 80% AM at 1kHz 40% reduction, 200ms 70% reduction, 500ms 90% reduction, 5s not applicable input below 75W EN-61000-4-2, Criteria A EN-61000-4-3, Criteria A EN-61000-4-4, Criteria A EN-61000-4-5, Criteria A EN-61000-4-6, Criteria A EN-61000-4-8, Criteria A EN-61000-4-11, Criteria A EN-61000-4-11, Criteria B EN-61000-4-11, Criteria B EN-61000-3-2 EN-61000-3-3

PA-5REV.: 3/2016www.recom-power.com Specifications (measured at TA= 25°C, 230VAC, full load and after warm up) REDIN45 Series 7.5±0.2 101.2 92.0 45.1 75±0.3 35±0.1 DIN-RAIL mounting bracket (75mm) included SIDE MOUNTINGEND MOUNTING 18±0.2 1±0.05 25.0 25.0 6.3±0.2 Side Latch Release End Latch Release Front Side Front Side DC OK DC OK DC OK TRIM Tolerance: ±0.5mm FG N L +V -V FG N L +V -V 7.5±0.2 101.2 92.0 45.1 75±0.3 35±0.1 DIN-RAIL mounting bracket (75mm) included SIDE MOUNTINGEND MOUNTING 18±0.2 1±0.05 25.0 25.0 6.3±0.2 Side Latch Release End Latch Release Front Side Front Side DC OK DC OK DC OK TRIM Tolerance: ±0.5mm FG N L +V -V FG N L +V -V Dimension Drawing (mm) Mounting Instruction Mounting „Click“ Front Side FG N L Releasing Front Side

2 FG N L

www.recom-power.comPA-6 REV.: 3/2016 Specifications (measured at TA= 25°C, 230VAC, full load and after warm up) REDIN45 Series 0mm no spacers between supplies required 0mm FG N L FG N L FG N L Mounting Multiple Power Supplies Functional Diagram Power Stage LED L T2.5A N E DC OK Vadj. Relay Output Filter Protection Input Filter Outoput Voltage Regulation OVP Shut- Down OTP Shut- Down OCP Limit The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) Cardboard Box 310 x 285 x 252mm Packaging Quantity 30pcs Storage Temperature Range -30°C to +85°C Storage Humidity 10% - 90% RH