RD L100 Series D C -D C C onverter xxx Series w w w .xppow er.com 1 M odels & Ratings Notes 1. M easured at 20 M H z bandw idth pk-pk, full load, 10 µF tantalum and 1.0 µF ceram ic capacitors for 12 V , 15 V & 24 V m odels, 47 µF alum inium capacitor and 1.0 µF ceram ic capacitor for 48 V m odel. 2. M easured at 110 V input and full load. 3. M easured at 66 VD C input.
- Wide 3:1 Input Range
- Covers 110 VDC Nominal Input for Rail Applications
- Complies with EN50155
- Meets EN50121-3-2
- Single Output
- Industry Standard Half Brick
- -40 °C to +100 °C Operation
- Output Trim ±10%
- Remote On/Off
- 3 Year Warranty Dim ensions: RDL100:
100 Watts
- All dimensions are in inches (mm) 2. Weight: 0.198 lbs (90 g) approx. x.xxx = ±0.01 (x.xx = ±0.25) Notes Mounting Holes 0.126 (3.2) clearance,
4 Places Bottom View
2.40 (61.0) 2.00 (50.8) 1.40 (35.5) 0.50 (12.7) 0.18 (4.6) 0.6 (15.2) 1.9 (48.3) 2.28 (57.9) 2ø0.08 (2.03) 7ø0.04 (1.02) M echanical Details Input Voltage O utput Voltage O utput C urrent Input C urrent R ipple & noise (1) Efficiency (2) M ax. capacitive load M odel N um ber N o Load Full Load (3 ) 66-160 V 12 V 8.30 A 3 mA 1.75 A 150 mV 86.5% 8300 µF RDL100110 S12 15 V 6.70 A 3 mA 1.04 A 150 mV 87 .5% 4170 µF RDL100110 S15 24 V 4.17 A 3 mA 1.04 A 240 mV 87 .5% 4170 µF RDL100110 S24 48 V 2.08 A 3 mA 1.02 A 480 mV 89.0% 1500 µF RDL100110 S48 Pin Function 1 +Vin
2 Remote On/Off
7 T rim
w w w .xppow er.com 2 D C -D C C onverter Input O utput C haracteristic M inim um Typical M axim um U nits N otes & C onditions Output Voltage 12 48 VDC See Models and Ratings table Output T rim -10 +10 % See Application Note Initial Set Accuracy ±1.5 % At full load and 110 V input Minimum Load 0% No minimum load required Line Regulation ±0.2 % From minimum to maximum input at full load Load Regulation ±0.2 % From 0% to full load T ransient Response ±3.0 ±5.0 % Maximum deviation, recovering to less than 1% in 500 µs for 25% step load change. Start Up Time 120 ms Output Voltage Rise Time 15 ms Ripple & Noise mV pk-pk See models and ratings table Overload Protection 110 130 160 % Short Circuit Protection Continuous hiccup mode, with auto recovery Maximum Capacitive Load See Models and Ratings table T emperature Coefficient 0.03 %/ ˚C Overvoltage Protection 115 125 140 % Remote On/Off Ouput is on if REM On/Off (pin 2) is open or high (3.5-75 VDC) WRT -Vin Output turns off if REM On/Off (pin 2) is low (<1.8 VDC max) WRT -Vin C haracteristic M inim um Typical M axim um U nits N otes & C onditions Input Voltage Range 66 160 VDC 110 V nominal input Input Surge 180 VDC for 100 ms Undervoltage Lockout On: >60 V 62 64 VDC On Off: <54 V 56 58 Off Lockout Hysteresis 6 VDC Idle Current 1.5 5 mA When output is inhibited Inrush Current 0.1 A2s Input Reflected Ripple Current 50 mA pk-pk Through 12 µH inductor Recommended Input Fuse T4.0A G eneral C haracteristic M inim um Typical M axim um U nits N otes & C onditions Efficiency 88 % See Models and Ratings table Isolation: Input to Output 3000 VAC 60 s Isolation: Input to Case 1500 VAC 60 s Isolation: Output to Case 500 VAC 60 s Isolation Resistance 10 9 Ω Isolation Capacitance 500 pF Input to output Switching Frequency 250 kHz Fixed Power Density 36.5 W/in 3 Mean Time Between Failure 830 kHrs MIL-HDBK-217F , +25 °C GB Weight 0.198 (90.0) lb (g) Environm ental C haracteristic M inim um Typical M axim um U nits N otes & C onditions Operating Base Plate T emperature -40 +100 °C Storage T emperature -55 +105 °C Thermal Protection + 105 °C Measured on baseplate Humidity 95 %RH Non-condensing Cooling Base plate cooled
w w w .xppow er.com D C -D C C onverter M echanical Details EM C: Im m unity Phenom enon Standard Test Level C riteria N otes & C onditions Railway Equipment EN50121-3-2 See Application Note ESD Immunity EN61000-4-2 ±6 kV/±8 kV A C ontact D ischarge/Air D ischarge Radiated Immunity EN61000-4-3 10 V/m A EFT/Burst EN61000-4-4 2 kV A External capacitor required such as R ubycon 4XF Series, 220 µF/200V Surge EN61000-4-5 ±1 kV A L-E/L-L, External TVS, 1.5 K E 180 A Littlefuse Conducted Immunity EN61000-4-6 10 V rms A EM C: Em issions Phenom enon Standard Test Level N otes & C onditions Conducted EN50121-3-2 See Application N otes Radiated EN50121-3-2 See Application N otes Safety A pprovals Agency Standard Test Level N otes & C onditions UL cUL60950-1 ITE EN EN60950-1 ITE EN50155 R ailw ay 1. All dimensions are in inches (mm) 2. Weight: 0.22 lbs (100 g) approx. x.xxx = ±0.01 (x.xx = ±0.25) Notes Mounting Holes 0.126 (3.2) clearance, 2.40 (61.0) 2.00 (50.8) 1.40 (35.5) 0.50 (12.7) 0.18 (4.6) 0.6 (15.2) 1.9 (48.3) 2.28 (57.9) 2ø0.08 (2.03) 7ø0.04 (1.02) Pin Function 1 +Vin
w w w .xppow er.com 4 D C -D C C onverter A pplication N otes Input Fusing and Safety Considerations The RDL100 series converters have no internal fuse. In order to achieve maximum safety and system protection, always use an input line fuse. We recommended a 4 A time delay fuse. It is recommended that the circuit has a transient voltage suppressor diode (TVS) across the input terminals to protect the unit against surge or spike voltages and input reverse voltage (as shown). A suitable part would be 1.5KE180A. Output Voltage Adjustment The T rim input permits the user to adjust the output voltage up or down by 10%. This is accomplished by connecting an external resistor between the T rim pin and either the +Sense pin or the -Sense pin. To Trim Up Connecting an external resistor (Rd) between the T rim pin and the -Sense pin decreases the output voltage. The following table can be used to determine the required external resistor value to obtain a percentage output voltage change of Δ%. -Vin +Vin1 +Vout +Sense Trim -Sense -Vout Vin TVS Load Trim Up Rd Trim Down Ru Fuse To Trim Down Connecting an external resistor (Ru) between the +Vout pin and the +Sense pin increases the output voltage. The following table can be used to determine the required external resistor value to obtain a percentage output voltage change of Δ%. Trim D ow n % 12 V 15 V 24 V 48 V R d (k Ω) 1 660.32 932.00 1641.67 3500.43 2 300.11 432.00 745.83 1595.11 3 180.04 265.33 447 .22 960.01 4 12.00 182.00 297 .92 642.46 5 83.98 132.00 208.33 451.93 6 59.97 98.67 148.61 324.90 7 42.82 74.86 105.95 234.18 8 29.95 57 .00 73.96 166.13 9 19.95 43.11 49.07 113.20 10 11.94 32.00 29.17 70.86 Trim U p% 12 V 15 V 24 V 48 V R u (k Ω) 1 153.23 160.83 165.83 166.56 2 74.30 76.77 79.95 80.78 3 47 .99 48.78 51.33 52.18 4 34.83 34.79 37 .02 37 .89 5 26.94 26.39 28.43 29.31 6 21.68 20.80 22.71 23.59 7 17 .92 16.80 18.62 19.50 8 15.10 13.80 15.55 16.44 9 12.90 11.47 13.17 14.06 10 11.15 9.60 11.26 12.15
w w w .xppow er.com D C -D C C onverter Thermal Resistance Information Example (Without Heatsink) T o determine the minimum airflow necessary for a RDL100110S12 operating at an input voltage of 110 V , an output current of 8.3 A, and a maximum ambient temperature of 40°C: Determine Power dissipation (Pd): Pd = Pi-Po = Po(1- η)/ η, Where Pi = Input power, Po = Output Power and η = Efficiency Determine airflow from airflow derating graph using data points for Pd=17 .58 W and T a = 40 °C Minimum airflow= 500 ft./min. T o check that the maximum case temp of 100 °C is not exceeded: Maximum temperature rise is Maximum case temperature is Tc=T a+ ΔT=92.2°C <100°C. Where: Rca is the thermal resistance from case to ambient environment. T a is ambient temperature and Tc is case temperature. Po wer D issip ated v s Ambi ent T emperature a nd Ai r Flow w ithout he at sink 0 1 02 03 04 05 06 07 08 09 01 0 0 Amb ien t T empera tu re, Ta(° C) Power Disspated, Pd (Watts) Natur al C onvection 20 ft./min. (0 .1 m /s ) 100 f t./min. ( 0.5 m /s ) 200 f t./min. ( 1.0 m /s ) 300 f t./min. ( 1.5 m /s ) 400 f t./min. ( 2.0 m /s ) 500 f t./min. ( 2.5 m /s ) 600 f t./min. ( 3.0 m /s ) 700 f t./min. ( 3.5 m /s ) 800 f t./min. ( 4.0 m /s ) Air Flow R ate Typical R ca Natural Convection 20 ft/min (0.1 m/s) 7 .12 °C/W 100 ft/min (0.5 m/s) 6.21 °C/W 200 ft/min (1.0 m/s) 5.17 °C/W 300 ft/min (1.5 m/s) 4.29 °C/W 400 ft/min (2.0 m/s) 3.64 °C/W 500 ft/min (2.5 m/s) 2.96 °C/W 600 ft/min (2.5 m/s) 2.53 °C/W 700 ft/min (2.5 m/s) 2.37 °C/W 800 ft/min (2.5 m/s) 2.19 °C/W Airflow Derating Graph A pplication N otes
w w w .xppow er.com D C -D C C onverter M odel D 1 C 1 C 2 C 3 C 4 L1 L2 RDL100 110S12 1.5KE180A 220 µF/
200 V , YXF
220 µF/ 200 V , YXF 2200 pF 2200 pF 5 µH 0.5 mH RDL100 110S15 1.5KE180A 220 µF/ 220 µF/ 200 V , YXF 2200 pF 2200 pF 5 µH 0.5 mH RDL100 110S24 1.5KE180A 220 µF/ 220 µF/ 200 V , YXF 2200 pF 2200 pF 5 µH 0.5 mH RDL100 110S48 1.5KE180A 220 µF/ 220 µF/ 200 V , YXF 2200 pF 2200 pF 5 µH 0.5 mH
25 Jan 18
+Vin RDL100 -Vin +Vout -Vout +Vin -Vin Load +Vo -Vo EMC Filter - Emissions and Immunity Note: C1, C2 Aluminium Capacitors and C3, C4 Ceramic Capacitor