www.sensortechnics.com
FEATURES
absolute, gage or differential pressure
- Barometric pressure ranges
- SPI bus and analog output
- Precision ASIC conditioning
- Calibrated and temperature compensated
- Total accuracy ±1.0 %FSS
- Sensortechnics PRO services ELECTRICAL CONNECTIONSPECIFICATIONS Maximum ratings Supply voltage VS 4.75 V to 5.25 VDC max. 6.50 VDC Output current Sink 1 mA Source 1 mA Maximum pressure on any port6 10 bar Lead specifications Average preheating temperature gradient2.5 K/s Soak time ca. 3 min Time above 217°C 50 s Time above 230°C 40 s Time above 250°C 15 s Peak temperature 260°C Cooling temperature gradient -3.5 K/s Temperature ranges Compensated 0 to +85 °C Operating -10 to +85 °C Storage -20 to +105 °C Caution! The sensor is not reverse polarity protected. Incorrect applications of excitation voltage or ground to the wrong pin can cause electrical failure. Application of supply voltage above the maximum can cause electrical failure. Bottom view MEDIA COMPATIBILITY To be used with non-corrosive, non-ionic working fluids such as clean dry air, dry gases and the like. Note: MOSI is internally connected to high level. No external port is available. CLK Vout SS GND +Vs MISO Pin 1 marked by dot
www.sensortechnics.com PRESSURE RANGES SPECIFICATIONS Specification notes: 1. If maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture. 2. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure. 3. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset and full scale from nominal values. 4. Max. delay time between pressure change at the pressure die and signal change at the output. and reponse times are available on request. Please contact Sensortechnics for further information. 6. Maximum pressure on any port is the maximum operating plus common-mode pressure for differential pressure devices which can be applied without damaging the sensor. Common Mode Pressure is the pressure applied to both sides of the diaphragm simultaneously. traPr ebmune gnarerusserPt sruBe russerp 1 RA1160ECRr abm0011...006r ab2 UD520MECRr abm52...0r ab2.0 UD050MECRr abm05...0r ab53.0 UD001MECRr abm001...0r ab53.0 UD052MECRr abm052...0r ab1 UD005MECRr abm005...0r ab1 U)D,A(100BECRr ab1...0r ab2 U)D,A(200BECRr ab2...0r ab5 U)D,A(500BECRr ab5...0r ab01 BD010MECRr abm01±...0r ab2.0 BD520MECRr abm52±...0r ab2.0 BD050MECRr abm05±...0r ab53.0 BD001MECRr abm001±...0r ab53.0 BD052MECRr abm052±...0r ab1 BD005MECRr abm005±...0r ab1 BD100BECRr ab1±...0r ab2 RA6121ECRi sp61...21i sp03 UD010HECRH hcni01...0 2Oi sp3 UD100PECRi sp1...0i sp5 UD500PECRi sp5...0i sp51 U)D,A(510PECRi sp51...0i sp03 U)D,A(030PECRi sp03...0i sp07 U)D,A(001PECRi sp001...0i sp051 BD400HECRH hcni4±...0 2Oi sp3 BD010HECRH hcni01±...0 2Oi sp3 BD100PECRi sp1±...0i sp5 BD500PECRi sp5±...0i sp51 BD510PECRi sp51±...0i sp03
www.sensortechnics.com PERFORMANCE CHARACTERISTICS (Vs = 5.0 V, TA = 25 °C, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS) All RCE...(U,R) All RCE...B scitsiretcarahC. niM. pyT. xaMs tinU SCITSIRETCARAHCECNAMROFREPLATIGID erusserpdeificepstsewoltatesffO0 0710 0020 032 stnuoc)SSF(napselacslluF 2 00003 tuptuoelacslluF0 07130 00230 0323 SCITSIRETCARAHCECNAMROFREPEUGOLANA erusserpdeificepstsewoltatesffO6 2.01 3.05 3.0 V)SSF(napselacslluF 2 85.4 tuptuoelacslluF4 8.48 8.43 9.4 scitsiretcarahC. niM. pyT. xaMs tinU SCITSIRETCARAHCECNAMROFREPLATIGID tesffoerusserporeZ0 07610 00710 0371 stnuoc)SSF(napselacslluF 2 00003 tuptuOe russerpdeificeps.xamta0 07130 00230 0323 erusserpdeificeps.nimta0 0710 0020 032 SCITSIRETCARAHCECNAMROFREPEUGOLANA tesffoerusserporeZ5 5.29 5.24 6.2 V)SSF(napselacslluF 2 85.4 tuptuOe russerpdeificeps.xamta4 8.48 8.43 9.4 erusserpdeificeps.nimta6 2.01 3.05 3.0 scitsiretcarahC. niM. pyT. xaMs tinU )C°58...0(ycaruccalatoT 3 0.1±S SF% yaledesnopseR 5,4 5.0s m noituloserD/A 5 21 tib noituloserA/D 11 )daolon(noitpmusnoctnerruC 5A m All devices
www.sensortechnics.com Introduction The RCE is capable to generate a digital output signal. The device runs a cyclic program, which will store a corrected sensor value with 12-bit resolution about every 250 µs within the output registers of the internal ASIC. This cyclic program runs independent from the bus communication. In order to use the RCE pressure sensor for digital signal readout, it should be connected to a SPI Master device. SPI specifies four signals: The clock (CLK) is generated by the master and input to all slaves. MOSI carries data from master to slave. MISO carries data from slave back to master. A slave select line (SS) allows individual selection of a slave device. SPI Modes A pair of parameters called clock polarity (CPOL) and clock phase (CPHA) determine the edges of the clock signal on which the data are driven and sampled. Each of the two parameters has two possible states, which allows for four possible combinations, all of which are incompatible with one another. In general the RCE series supports all combinations of clock phase (CPHA) and polarity (CPOL). By default it is programmed to CPHA = 0 and CPOL = 0, which means that data transmission starts with the rising first clock edge (see Fig 1). Slave select The falling edge of the SS line indicates the beginning of the transfer. Additionally the SS line must not be negated and reasserted between the three bytes to be transmitted. Data operation The MOSI is internally connected to high level. So there is no data transmission from master to slave. Because of internal configuration the slave will answer the first byte with an FFxh. The second and third byte contain the 15 bit pressure information (see Fig. 2). SPI - SERIAL PERIPHERAL INTERFACE For further information please refer to Sensortechnics SPI bus application note Fig. 2: 3 byte data stream between RCE sensor and master containing the pressure value as a 15 bit information Fig. 1:Example of a standard 1 byte SPI data transfer for CPHA=0 and CPOL=0 Relevant data Data Byte 2 Data Byte 3 X P14 P13 P12 P11 P10 P9 P8 P7 P6 P5 P4 P3 P2 P1 P0X X X X X X X X Data Byte 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1MOSI MISO SCK cycle 1 2 3 4 5 6 7 8 SCK (CPOL=0) MOSI MISO SS MSB LSB LSBMSB Sampling
www.sensortechnics.com SPI - SERIAL PERIPHERAL INTERFACE (cont.) Interface parameters retemaraPl obmyS. niM. pyT. xaMt inU levelhgihtupnI0 90 01 sVfo%levelwoltupnI0 0 1 levelwoltuptuO 01 rotsiserpu-lluP0 05 Ω OSIM@ecnaticapacdaoL C OSIM 004 Fpniphcae@ecnaticapactupnI C NI_IPS 01 ycneuqerfkcolclangiS f KCS *0010 46z Hk epolselpmasKCSretfaemitdlohOSIM t OSIM_DH_IPS 002s n epolselpmasKCSerofebemitputesISOM t ISOM_US_IPS f/2 KLC epolselpmasKCSerofebemitputesSS/ t SS_US_IPS 01s n * recommended Fig. 3:Timing characteristics t t SS MISO MOSI SCK (CPOL=0) SPI_SU_SSt SPI_SU_MOSI SPI_HD_MISO Note: Sensortechnics recommends communication speeds of at least 100 kHz (max. 640 kHz). Please contact your nearest Sensortechnics sales office for further information.
www.sensortechnics.com PHYSICAL DIMENSIONS dimensions in inches (mm) third angle projection 1 2 3 4 5 6 0.85 (21.6) 1.10 ref (27.9 ref 0.80 (20.3) 0.190 (4.8) 2 pls 0.36 (9.1) Ø 0.08 (2.0) pressure port B 0.42 (10.7) 1.03 ref (26.2) ref 0.55 (14.0) 0.05 (1.3) 0.20 (5.1) Ø 0.08 (2.0) pressure port A 1.08 (27.4) 0.41 (10.4) 0.25 (6.4) Ø 0.14 (3.6) thru rivet mounting holes pins 6 pls 0.05 (1.3) 0.10 (2.5) pin spacing R0.13 (R3.3) typ Port B: High pressure Port for gage and differential devices Port A: High pressure Port for absolute devices
www.sensortechnics.com
ORDERING INFORMATION
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. seireS egnarerusserP edomerusserP noitarbilaC snoitpOE CR *1160 rabm0011...006 *A etulosbA B lanoitceridiB 010M rabm01 D egaG/laitnereffiD U lanoitceridinU 520M rabm52 R cirtemoraB 050M rabm05 001M rabm001 052M rabm052 005M rabm005 100B rab1 *200B rab2 ***500B rab5 *6121 isp61...21 400H Hhcni4 2O 010H Hhcni01 2O 100P isp1 500P isp5 510P isp51 *030P isp03 ***001P isp001 secivedcirtemorabsaelbaliavaylno* lanoitceridibsaelbaliavaylno secived lanoitceridinusaelbaliavaylno* secived morfelbaliavaylno* rofdnaisp51/rab1 segnarcirtemorab :elpmaxE ECR 520M D B Sensortechnics PRO services:
- Extended guarantee period of 2 years
- Custom product modifications and adaptations even for small quantities
- Advanced logistics models for supply inventory and short delivery times
- Technical support through application engineers on the phone or at your site
- Fastest possible technical response for design and QA engineers ... plus other services on request