RBB10-2.0 RECOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
Features
- 10W buck/boost converter with up to 4A output
- Input voltage can be higher, lower or same as output voltage
- >90% efficiency from 100mA – 3000mA load
- 7µA standby power consumption
- Low profile, thermally enhanced 25pad LGA package Notes: Note1: Max. Cap Load is tested at nominal input and full resisitive load nom. Output Current Model Numbering RBB10-2.0 Selection Guide Part Input Voltage Nom. Output Output Efficiency Max. Capacitive Number Range Voltage Current max. typ. Load (1) [VDC] [VDC] [A] [%] [µF] RBB10-2.0 2.3 - 5.5 5 2 - 4 96 42000 (1.0 - 5.5) EN55032 compliant BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter capacitor Input Voltage Range (2) Vin = 5VDC 2.3VDC 5VDC 5.5VDC Absolute Maximum Input Voltage 7VDC Undervoltage Lockout Threshold 1.6VDC 1.75VDC 2.0VDC Undervoltage Lockout Hysteresis 65mV Input Current Vin= 5VDC Vin= 3.6VDC 2.3A 3.4A Quiescent Current Vin= 5VDC 40µA 90µA Internal Power Dissipation Vin= 5VDC Vin= 3.6VDC 0.9W 1.8W Output Current Range refer to safe operating area 0A 2A 4A Output Voltage Trimming (3) see table or calculation 1.0VDC 5.0VDC 5.5VDC Minimum Load 0% Start-up time power up 2A Vin= 5VDC Vin= 3.6VDC 1.4ms 1.8ms BUCK BOOST Vin= 5VDC Vin= 3.6VDC 700µs 450µs continued on next page Specifications (measured @ Ta= 25°C, 5Vin, 5Vout, 2A and after warm-up unless otherwise stated)
www.recom-power.com REV.: 0/2018 RBB-2 DC/DC Converter Specifications (measured @ Ta= 25°C, 5Vin, 5Vout, 2A and after warm-up unless otherwise stated) RBB10-2.0 Series Parameter Condition Min. Typ. Max. Rise Time 400µs ON/OFF CTRL nom. Vin= 5VDC DC-DC ON DC-DC OFF Open or 1.2V<VCTRL<Vin Short or -0.3V<VCTRL<0.4VDC Input Current of CTRL Pad nom. Vin= 5VDC CTRL voltage = 0V 5µA Standby Current nom. Vin= 5VDC CTRL voltage = 0V 5.1µA 7µA Internal Operating Frequency 2.55MHz Output Ripple and Noise (4) 20MHz BW - 98W @ 100MHz + 22µF 15mVp-p Absolute Maximum Capacitive Load <1 second start up Css = 3700nF 42000µF <1 second start up no Css 800µF Notes: Note2: For detail information please refer to “Safe Operating Area” graph below Note3: For detail information please refer to trim table or calculation on page RBB-3 Note4: Measurements are made with a 22µF MLCC across output (low ESR) Efficiency vs. Load 5Vout 3.3Vout 100 Efficiency [%] Output Current [A] 2.5Vin 3.6Vin 5.0Vin 5.5Vin 100 Efficiency [%] Output Current [A] 2.5Vin 3.6Vin 5.0Vin 5.5Vin 4.5 4.0 3.0 2.0 3.5 2.5 1.5 1.0 0.5 Output Current [A] Input Voltage [VDC] 2.3 2.7 3.1 3.3 3.6 5.0 5.5Vout 5.0Vout 3.3Vout 1.0Vout Safe Operating Area
www.recom-power.com REV.: 0/2018 RBB-3 DC/DC Converter Specifications (measured @ Ta= 25°C, 5Vin, 5Vout, 2A and after warm-up unless otherwise stated) RBB10-2.0 Series OUTPUT VOLTAGE TRIMMING The RBB10-2.0 series offers the feature of trimming the output voltage over a range between 1.0V and 5.5V by using external trim resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may slightly vary. Rup +Vout Trim Rdown GND Trim Trim up Trim down Voutnom R1 R2 R3 Vref 5VDC 629kW 1kW 788kW 0.805 Practical Example RBB10-2.0: Calculation: Voutnom = nominal output voltage [VDC] Voutset = trimmed output voltage [VDC] Vref = reference voltage [VDC] Rup = trim up resistor [W] Rdown = trim down resistor [W] R1, R2, R3 = internal resistors [W] Rup = 629k - 1k = 1M26W5.5 - 5.0 Rup according to E96 ≈ 1M27W Rdown according to E96 ≈ 2M55W Rdown = (4.0 - 0.805) x 788k = 2M52W5.0 - 4.0 Rdown = (Voutset - Vref) x R3 Voutnom - Voutset Rup = - R2 Voutset - Vnom Rup (E96) ≈ 6M34 3M16 2M10 1M58 1M27 [W] RBB10-2.0 Trim up Trim down Rdown (E96) ≈ 5M90 2M55 1M43 1M15 866k 536k 316k 243k 158k 38k3 [W] REMOTE SENSE GND +Vin +Vin GND GND Trim +Sense +Vout Rup RW1 Rdown GND +Vout RW1 ... wire losses + Rup ... trim up resistor Rdown ... trim down resistor The output voltage can be adjusted via the trim and sense functions. The maximum output voltage from Trim and Sense function combined is 5.5VDC. Derating may be required when using Trim and/or sense functions.
www.recom-power.com REV.: 0/2018 RBB-4 DC/DC Converter Specifications (measured @ Ta= 25°C, 5Vin, 5Vout, 2A and after warm-up unless otherwise stated) RBB10-2.0 Series REGULATIONS Parameter Condition Value Output Accuracy ±3.0% max. Line Regulation low line to high line, full load 1.0% typ. / ±3.0% max. Load Regulation 0% to 100% load PWM mode selected (5) 0.5% max. Transient Response 100% - 0% load step recovery time 200mV max. 500µs typ. PROTECTIONS Parameter Condition Value Short Circuit Protection (SCP) 50mW constant current limit Short Circuit Input Current nom. Vin= 2.3VDC 700mA typ. Over Current Protection (OCP) refer to safe operating area 220% - 240%, constant current mode Over Temperature Protection (OTP) case temperature (measured on tc point) DC-DC OFF DC-DC ON 110°C, auto restart after cool down 100°C typ. ENVIRONMENTAL Parameter Condition Value Operating Temperature Range (6) @ natural convection 0.1m/s (refer to derating graph) up to 4A load up to 2A load -40°C to +85°C -40°C to +100°C Maximum Case Temperature +110°C Temperature Coefficient @ +65°C Tamb 0.02%/K Thermal Impedance 0.1m/s, horizontal (Tcase to Tamb) 8K/W Operating Altitude with derating @ natural convection 0.1m/s (refer to altitude vs. load graph) 5000m Operating Humidity non-condensing 5% - 95% RH max. Shock MIL-STD-810G, Method 516.6, Procedure I 40g, 11ms, saw-tooth, 3 shocks ± per axis 3 axis; unit is operating MIL-STD-810G, Method 516.6, Procedure IV drop on 50mm plywood on concrete 26 times from 1 meter Temperature Cycling MIL-STD-883F, Method 1010, Condition A powered -50°C to +85°C, 300 cycles Random Vibration MIL-STD-810G, Method 514.6, Procedure I, Category 24 Category 24 - Figure 514.6E-1 - power spectral density = 0.04g2/Hz at 20Hz –1000Hz, -6dB/Octave at 1000Hz – 2000Hz, 60 minutes x 3 axis; unit is operating during tests MTBF according to MIL-HDBK-217F, G.B. +25°C +85°C 2200 x 103 hours 400 x 103 hours continued on next page Notes: Note6: tested with a eurocard 160x100mm 70µm copper, 4 layer Notes: Note5: The RBB10 has the possibility to work in two regulation modes: Powersave Mode (standard): This mode is the best for use at low loads to reduce power consumption and extend battery life. In this mode the internal power consumption is reduced by using burst mode for loads under 350mA and PWM for loads above 350mA. The drawback is a 1-3 % higher output voltage at low load than full load. Fixed PWM mode: In PWM mode the device accurately regulates the output voltage independently of the load current. The drawback is a higher internal power consumption and shorter battery life at lower loads. Pull down the Mode pad to GND to enter this mode.
www.recom-power.com REV.: 0/2018 RBB-5 DC/DC Converter Specifications (measured @ Ta= 25°C, 5Vin, 5Vout, 2A and after warm-up unless otherwise stated) RBB10-2.0 Series SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard RoHS 2 RoHS 2011/65/EU EMC Compliance Condition Standard / Criterion Electromagnetic compatibility of multimedia equipment - Emission requirements with external components EN55032, Class B Information technology equipment - Immunity characteristics - Limits and methods of measurement EN55024:2010+A1:2015 EMC Filtering Suggestions according to EN55032 Vin Mode GND1 GND3 GND2 NC Trim PG Sense Vout CTRL Vin Vout FB1 C2 C3 FB2 Component List Class B C1 C2 FB1 FB2 C3 10µF 25V X7R 10µF 25V X7R WE ref.: 742792510 WE ref.: 7427932 22µF 10V 7XR -40 -20 0 20 40 7060-30 -10 10 30 50 80 90 110100 4.0 2.5 1.5 3.5 3.0 2.0 1.0 0.5 Output Current [A] Ambient Temperature [°C] 5.5Vin 5.0Vin 3.6Vin 2.5Vin Operating Altitude [m] 0 1000 2000 3000 4000 5000 6000 4.0 2.5 1.5 3.5 3.4 3.0 2.0 1.0 0.5 Output Current [A] +85°C -40°C to +70°C Derating Graph (6) (@ chamber and natural convection 0.1m/s) Operating Altitude vs Load (@ chamber and natural convection 0.1m/s)
www.recom-power.com REV.: 0/2018 RBB-6 DC/DC Converter Specifications (measured @ Ta= 25°C, 5Vin, 5Vout, 2A and after warm-up unless otherwise stated) RBB10-2.0 Series DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case PCB solder pads metal FR4, (UL94 V-0) copper with electrolytic nickel-gold Dimension (LxWxH) 12.19 x 12.19 x 3.75mm Weight 1.1g typ. Dimension Drawing (mm) A B C D E 2 3 4 51 A B C D E 2 3 4 5 tc 11.70 11.70 12.19 ±0.5 1.025 x R0.3 3.75 1.061.06 Top View 1.52 12.19 ±0.2 2.291.52 Bottom View Recommended Footprint Details Pinning information Pad # Function Description A1, A2 Vin Positive input voltage with respect to GND. Connect to a Vin plane for enhanced thermal performance C1 CTRL High active: pull to GND to disable the device. Pull high or leave open to enable the device A5, B5 Vout Positive output voltage. Connect to a Vout plane for enhanced thermal performance C5 Sense Connect this pad to the load or directly to Vout. This pad must not be left floating E5 Trim Used to set the output voltage between 0.9V and 6V E1 NC Not connected E2 Mode Refer to note 5 on page RBB-4 D1 PGood Output power good. High = Vout at set level, low = Vout outside of specification. Maximum sink current is 2mA. A3, A4, B1, B2, B3, B4, C2, C3, C4, D2, D3, D4, D5, E3, E4 GND Negative input voltage. Connect to GND plane(s) for enhanced thermal performance tc = case temperature measuring point Tolerance: xx.xx= 0.25mm PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tape and reel tape and reel (carton) 330.2 x 330.2 x 30.4mm 355.0 x 350.0 x 50.0mm Packaging Quantity tape and reel 500pcs Tape Width 24mm Storage Temperature Range -55°C to +125°C Storage Humidity non-condensing 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.