RAC25-K-480 RECOM | Alldatasheet
Document overview
- PDF pages: 7
Technical content
Features
- OVC III and PD3 up to 5000m altitude
- 85-528VAC input r ange
- -40°C to +90°C operating temper ature:
- LPS limited power sour ce
- EN55032 class “B”; floating outputs
- No load power consumption <0.3W RAC25-K/480 Selection Guide Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ (1) Load (1) [VAC] [VDC] [mA] [%] [µF] RAC25-05SK/480 85-528 5 5000 82 20000 RAC25-12SK/480 85-528 12 2080 84 18000 RAC25-15SK/480 85-528 15 1670 85 6000 RAC25-24SK/480 85-528 24 1040 87 4000 Model Numbering Singlenom. Output Power Output Voltage RAC25-__ SK/480
Description
The RAC25-K/480 series AC/DC modules with ultra-wide input range of 100-480 VAC are specially designed for harsh industrial conditions of overvoltage category OVC III and pollution degree PD3 in both single-phase and phase-to-phase power connections of class II. These power supplies are capable of operating over a wide temperature range of -40° to 90°C (up to 70°C without derating) to be completed by the addition of an external fuse, offer LPS limited outputs with continuous overcurrent protection, surge immunity to level 3 and emission class B EMC compliance in potential free configurations. The silicone-free encapsulated modules are built extremely compact to fit on printed circuit boards without compromising board area. Global safety certifications ensure fast time-to-market when integrated into applications for markets such as Smart Grid, Smart Metering, Renewable Energy; Sensors and actuators or IoT applications. Notes: Note1: Is tested at 230V AC input and constant resistive load at +25°C ambient E224736 ERP compliant RECOMCONVERTERS COM PLIANT PRODUCTS REACH compliant RECOMCONVERTERS COM PLIANT PRODUCTS RoHS compliant 10 from 10 IEC/EN62368-1 certified UL62368-1 certified CAN/CSA-C22.2 No. 62368-1-14 certified IEC/EN61010 certified IEC/EN60335-1 pending EN62233 pending EN55032 compliant EN55035 compliant CB Report BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Nominal Input Voltage (2) 50/60Hz 100VAC 277VAC 480VAC Input Voltage Range (3) 47-63HZ 85VAC 528VAC DC 120VDC 750VDC Input Current 115/230VAC 480VAC 500mA 400mA Inrush Current cold start 115VAC 20A 230VAC 40A 480VAC 50A continued on next page Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Notes: Note2: 480VAC limited to L-L connections Note3: The products were submitted for safety files a t AC-Input operation
www.recom-power.com REV.: 0/2022 PA-2 RAC25-K/480 Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. No Load Power Consumption 85-528VAC 300mW Input Frequency Range AC Input 47Hz 63Hz Minimum Load 0% Power Factor 115VAC 0.45 230VAC 0.4 480VAC 0.3 Start-up Time 130ms Rise Time 30ms Hold-up Time 30ms Internal Operating Frequency 50kHz Output Ripple and Noise (4) 20MHz BW VOUT= 5VDC 100mVp-p others 1% of VOUT Efficiency vs. Load 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 115VAC 230VAC 480VAC 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 115VAC 230VAC 480VAC 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 115VAC 230VAC 480VAC 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 115VAC 230VAC 480VAC RAC25-05SK/480 RAC25-15SK/480 RAC25-12SK/480 RAC25-24SK/480 Notes: Note4: Measurements are made with a 0.1µF MLCC & 10µF E-cap in parallel across output (low ESR).
Output Accuracy ±3.0% max. Line Regulation low line to high line ±2.0% typ. Load Regulation (5) 10% to 100% load 2.0% typ. Transient Response 25% load step change 4.0% max. recovery time 1ms typ. AC/DC Converter www.recom-power.com REV.: 0/2022 PA-3 RAC25-K/480 Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Deviation vs. Load -0.4 -0.8 -1.2 -0.2 -0.6 -1.4 -1.6 Deviation [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] 115VAC 230VAC 480VAC 0.4 -0.4 -0.8 0.2 -0.2 -0.6 Deviation [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] 115VAC 230VAC 480VAC RAC25-05SK/480 RAC25-15SK/480 RAC25-12SK/480 RAC25-24SK/480 -0.4 -0.8 -1.2 -0.2 -0.6 -1.4 Deviation [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] 115VAC 230VAC 480VAC -0.4 -0.8 -1.2 -0.2 -0.6 -1.6 -1.4 Deviation [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] 115VAC 230VAC 480VAC Notes: Note5: Operation below 10% load will not harm the converter , but specifications may not be met PROTECTIONS Parameter Type Value Input Fuse external (refer to “Protection Circuit”) T2A, 600VAC min. Limited Power Source (LPS) according to IEC62368-1 CB Report yes Short Circuit Protection (SCP) below 100mW hiccup, auto recovery Over Voltage Protection (OVP) 105% - 120%, hiccup mode Over Current Protection (OCP) 128% - 155%, hiccup mode Over Voltage Category according to 61010-1 OVCIII (up to 5000m) continued on next page
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC25-K/480 Series www.recom-power.com REV.: 0/2022 PA-4 ENVIRONMENTAL Parameter Condition Value Operating Temperature Range refer to “Derating Graph” -40°C to +90°C Maximum Case Temperature +105°C Temperature Coefficient 0.02%/K Operating Altitude 5000m Operating Humidity non-condensing 95% RH max. Polution Degree PD3 Vibration according to MIL-STD-202G 10-500Hz, 2G 10min./1cycle, 60min. each along x,y,z axes Design Lifetime 230VAC/50Hz +50°C 30 x 10³ hours MTBF according to MIL-HDBK-217F, G.B. VOUT= 5, 12VDC +25°C 950 x 10³ hours VOUT= 15, 24VDC 1040 x 10³ hours VOUT= 5, 12VDC +40°C 800 x 10³ hours VOUT= 15, 24VDC 920 x 10³ hours continued on next page Parameter Type Value Isolation Voltage (6) tested for 1 minute I/P to O/P 3.6kVAC tested for 5 seconds 5.4kVAC Isolation Resistance 1GW max. Isolation Capacitance 3200pF max. Insulation Grade reinforced Leakage Current 250µA max. Notes: Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage -Vout +Vout +Vout -Vout L (L1) N (L2) FF VACin (L, L1) VACin(N, L2) Protection Circuit An external fuse is mandatory in order to protect the device in addition on the AC input side. RECOM recommend: slow blow type, 600VAC, 2A -40 -30 -20 -25 -10 10 30 50 70 900 20 40 60 80 100 12.5 Output Load [W] Ambient Temperature [°C] 480VAC 220/277VAC 100/115VAC -40 -30 -20 -10 10 30 50 70 900 20 40 60 80 100 7.5 Output Load [W] Ambient Temperature [°C] 480VAC 220/277VAC 100/115VAC Derating Graph (@ Chamber and natural convection 0.1m/s) RAC25-05SK/480 RAC25-12SK/480
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC25-K/480 Series www.recom-power.com REV.: 0/2022 PA-5 -40 -30 -20 -10 10 30 50 70 900 20 40 60 80 100 12.5 7.5 Output Load [W] Ambient Temperature [°C] 480VAC 220/277VAC 100/115VAC -40 -30 -20 -10 10 30 50 70 900 20 40 60 80 100 22.5 12.5 2.5 Output Load [W] Ambient Temperature [°C] 480VAC 220/277VAC 100/115VAC RAC25-15SK/480 RAC25-24SK/480 Derating Graph (@ Chamber and natural convection 0.1m/s) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report Number Standard Audio/Video, information and communication technology equipment - Safety requirements E491408-A6020-UL UL62368-1, 3rd Edition, 2019 CAN/CSA C22.2 Nr. 62368-1-14, 3rd Ed. 2019 Audio/Video, information and communication technology equipment - Safety requirements (CB) 211112013 IEC62368-1:2014 2nd Edition Audio/Video, information and communication technology equipment - Safety requirements (LVD) EN62368-1:2014 + A11:2017 Audio/Video, information and communication technology equipment - Safety requirements (CB) 211112012 IEC62368-1:2018 3rd Edition Audio/Video, information and communication technology equipment - Safety requirements EN/IEC62368-1:2020 + A11:2020 Household and similar electrical appliances – Safety – Part 1: General requirements EN60335-1:2012 + A15:2020 Household and similar electrical appliances – Safety – Part 1: General requirements pending IEC60335-1:2010 EN60335-1:2012 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure pending EN62233:2008 EAC TP TC 004/2011 RoHS2 RoHS-2011/65/EU + AM-2015/863 EMC Compliance (EN55032) (7) Condition Standard / Criterion Electromagnetic compatibility of multimedia equipment - Emission requirements EN55032:2015 + A11:2020, Class B Electromagnetic compatibility of multimedia equipment – Immunity requirements EN55035:2017 + A11:2020 ESD Electrostatic discharge immunity test Air: ±2, 4, 8kV Contact: ±2, 4kV EN61000-4-2:2009, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 3 V/m (80-5000MHz) EN61000-4-3:2006 + A2:2010, Criteria A Fast Transient and Burst Immunity AC Port: L, N, L-N ±1kV EN61000-4-4:2012, Criteria A Surge Immunity AC Port: L-N: ±1kV EN61000-4-5:2015, Criteria A Immunity to conducted disturbances, induced by radio-frequency fields AC Port: 3Vrms (0.15-10MHz) 3-1Vrms (10-30MHz) 1Vrms (30-80MHz) EN61000-4-6:2014, Criteria A continued on next page
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC25-K/480 Series www.recom-power.com REV.: 0/2022 PA-6 Power Magnetic Field Immunity 1A/m EN61000-4-8:2010, Criteria A Voltage Dips 100% (0.5P , 0.5P) 30% (25P , 30P) EN61000-4-11:2004, Criteria A EN61000-4-11:2004, Criteria A Voltage Interruptions 100% (250P/300P) EN61000-4-11:2004, Criteria B EMC Compliance (EN61204-3) (7) Condition Standard / Criterion Low voltage power supplies, d.c. output Part 3: Electromagnetic compatibility (EMC) EN IEC 61204-3:2018 ESD Electrostatic discharge immunity test Air: ±2, 4, 8kV Contact: ±4kV EN61000-4-2:2009, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 10V/m (80-1000MHz) 3V/m (1400-2000MHz) 1V/m (2000-2700MHz) EN61000-4-3:2006 + A2:2010, Criteria A Fast Transient and Burst Immunity AC Port: L, N, L-N ±2kV EN61000-4-4:2012, Criteria A Surge Immunity AC Port: L-N: ±1kV EN61000-4-5:2014 + A1:2017, Criteria A Immunity to conducted disturbances, induced by radio-frequency fields AC Port: 10Vrms (0.15-80MHz) EN61000-4-6:2014, Criteria A Power Magnetic Field Immunity 30A/m EN61000-4-8:2010, Criteria A Voltage Dips 100% (0.5P , 0.5P) 100% (1.0P , 1.0P) 60% (10P , 12P) 30% (25P , 30P) 20% (250P , 300P) EN61000-4-11:2004 + A1:2017, Criteria A Voltage Interruptions 100% (250P , 300P) EN61000-4-11:2004 + A1:2017, Criteria B Limits of Harmonic Current Emissions EN IEC 61000-3-2:2019 Limits of Harmonic Current Emissions EN61000-3-2:2014 Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013 + A1:2019 Notes: Note7: With earth referenced output connections, use of an external common mode choke 45mH (E-type) ma y be considered at the input. DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case/baseplate polycarbonate, (UL94V-0) potting PU, (UL94V-0) PCB FR4, (UL94V-0) Dimension (LxWxH) 83.23 x 46.43 x 30.40mm Weight 185g typ. continued on next page
www.recom-power.com REV.: 0/2022 PA-7 Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tray 365.0 x 210.0 x 56.0mm Packaging Quantity tube 12pcs Storage Temperature Range -40°C to +90°C Storage Humidity non-condensing 95% The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. 83.81 min. 47.03 min. 83.23 46.4330.44.00 ±1.0 6x Ø1.6 ±0.1 21.04 21.34 6x Ø2.0 68.93.35 3x 3.96 7.92 8.58 8.88 15.3319.76 69.35 3.27 2 x M3 6.0max. 2 3 consider millings for PCB adaption to creepage requirements Dimension Drawing (mm) Pinning information Pin # Single
1 VAC in (N) (L2)
2 VAC in (L) (L1)
Tolerance: xx.x= ±0.5mm xx.xx= ±0.25mm Recommended Footprint Details Top ViewBottom View