RAC03-GB RECOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Features

  • Universal input 85-305VAC
  • 3W PCB mount package
  • <75mW No load power consumption
  • Ultra low profile, compact size
  • -40°C to +85°C Operating temperature
  • Continuous SCP , OCP , OVP
  • IEC/EN/UL60950 & CE certified, EN55032 Class B RAC03-GB Selection Guide UL60950-1 certified IEC/EN60950-1 certified UL62368-1 pending IEC/EN62368-1 pending EN61558-1 pending EN61558-2-16 pending E196683 Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: Max. Cap. Load is tested at nominal input and full resistive load Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ.(1) Load (2) [VAC] [VDC] [mA] [%] [µF] RAC03-05SGB 85-305 5 600 72 1500 RAC03-12SGB 85-305 12 250 78 500 RAC03-24SGB 85-305 24 130 80 150 On Request RAC03-3.3SGB 85-305 3.3 910 70 2000 RAC03-09SGB 85-305 9 330 77 1000 RAC03-15SGB 85-305 15 200 78 200 BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Pi-Type Input Voltage Range(3) refer to line derating graph on page PA-4 85VAC 120VDC 305VAC 430VDC Input Current 115VAC 230VAC 70mA 45mA Inrush Current cold start at 25°C 115VAC 230VAC 10A 20A No Load Power Consumption 75mW Input Frequency Range AC Input 45Hz 65Hz Minimum Load 0% Power Factor 115VAC 230VAC 0.53 0.41 Start-up Time 115VAC, 230VAC 30ms 1s Hold-up Time 115VAC 230VAC 5ms 40ms Internal Operating Frequency 100% load at nominal Vin 65kHz continued on next page Model Numbering Ordering Example RAC03-12SGB = 3W Output Power, 12V Output Voltage, Single Output, EMC Class B Output Power Output Voltage RAC03-__SGB EMC Class B Single

PA-2 REV.: 2/2017 www.recom-power.com AC/DC Converter Specifications (measured @ ta=25°C, nom. Vin, full load unless otherwise noted) RAC03-GB Series Output Ripple and Noise(4) 20MHz BW 0°C to 85°C

5 Vout

-30°C to 0°C 5Vout 12Vout 24Vout 200mVp-p 250mVp-p 300mVp-p REGULATIONS Parameter Condition Value Output Accuracy ±2.5% max. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max. Efficiency vs. Load RAC03-12SGBRAC03-05SGB Accuracy vs. Load (@nom. Vin: 115/230VAC) 115VAC 230VAC Efficiency [%] Output Current [%] 20 40 60 80 10030 50 70 90 115VAC 230VAC Efficiency [%] Output Current [%] 20 40 60 80 10030 50 70 90 RAC03-12SGBRAC03-05SGB Accuracy [%] Output Current [A] 2.5 1.5 -1.5 0.5 -0.5 -2.5 Accuracy [%] Output Current [A] 2.5 1.5 -1.5 0.5 -0.5 -2.5 Notes: Note3: The products were submitted for safety files at AC-Input Operation Note4: Measurements are made with a 12” twisted pair-wire with a 0.1µF and 10µF parallel capacitor across output (low ESR)

PA-3REV.: 2/2017www.recom-power.com AC/DC Converter Specifications (measured @ ta=25°C, nom. Vin, full load unless otherwise noted) RAC03-GB Series PROTECTIONS Parameter Type Value Input Fuse internal T1A, 300V Short Circuit Protection (SCP) below 100mΩ long-term mode, auto recovery Over Voltage Protection (OVP) 5Vout 12Vout 24Vout 5.3V - 6.8V, hiccup mode auto recovery 12.6V - 16.2V, hiccup mode auto recovery 25.2V - 32.4V, hiccup mode auto recovery Over Current Protection (OCP) 5Vout 12Vout 24Vout 0.91A - 2.2A, hiccup mode auto recovery 0.37A - 0.95A, hiccup mode auto recovery 0.19A - 0.45A, hiccup mode auto recovery Class of Equipment Class II Over Voltage Category (OVC) OVC II Isolation Voltage(5) I/P to O/P rated for 1 minute 3kVAC/10mA Isolation Resistance 10MΩ min. Isolation Capacitance 800pF min., 1200pF max. Insulation Grade Reinforced Leakage Current 277VAC, 50Hz 0.1mA max. U L N Notes: Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note6: For operation at 230VAC, an external MOV is recommended. The Varistor should comply with IEC61051-2. eg. EPCOS S14 series ENVIRONMENTAL Parameter Condition Value Operating Temperature Range @ natural convection 1m/s see graph without derating -40°C to +70°C Maximum Case Temperature +100°C Temperature Coefficient ±0.03%/°C Operating Altitude 3000m Operating Humidity non-condensing 5% - 95% RH Pollution Degree PD2 Shock 20G/11ms pulse, 3 times at each x, y, z axes Vibration 10-150Hz, 2G 10min./1cycle, period 60min. along x,y,z axes for 6 cycles MTBF according to MIL-HDBK-217F, G.B. +25°C +70°C 100 x 103 hours 17 x 103 hours continued on next page

PA-4 REV.: 2/2017 www.recom-power.com AC/DC Converter Specifications (measured @ ta=25°C, nom. Vin, full load unless otherwise noted) RAC03-GB Series DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Material Case PCB black plastic, (UL94 V-0) FR4, (UL94 V-0) Package Dimension (LxWxH) 37.0 x 24.0 x 15.0mm Package Weight 20g typ. continued on next page Derating Graph (@ Chamber and natural convection 0.1m/s) Line Derating Graph 100 120 0 60 70 804020-20-40 10085 Output Power [%] Ambient Temperature [°C] 100 120 85 105 125 145 165 185 205 225 245 265 285 305 Output Power [%] Input Voltage [VAC] 100 SAFETY AND CERTIFICATION Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety (LVD) SA17031845 001 IEC60950-1, 2nd Edition: 2005 +9 + A2, 2013 EN60950-1: 2006 +A2, 2013 Information Technology Equipment, General Requirements for Safety E196683-A3-UL UL60950-1, 2nd Edition, 2014 CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014 Audio/video, information and communication technology equipment. Safety requirements pending UL62368-1, 2nd Edition CAN/CSA C22.2 No 62368-1 Audio/video, information and communication technology equipment. Safety requirements pending IEC62368-1, 2nd Edition: 2014 EN62368-1: 2014 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1100 V Part 2: Particular requirements pending EN61558-1: 2005 + A1, 2009 EN61558-2-16: 2009 + A1, 2013 RoHs 2+ RoHS 2011/65/EU + AM2015/863 EMC Compliance Condition Standard / Criterion Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement EA1703184E 01001 EN55032: 2015, Class B Limitations on the amount of electromagnetic intererence allowed from digital and electronic devices EA1703184E 01001 47 CFR FCC Part 15 Subpart B: 2016 ESD Electrostatic discharge immunity test Air ±8kV, Contact ±4kV EN61000-4-2: 2009, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 3V/m EN61000-4-3: 2006 + A2, 2010, Criteria A Fast Transient and Burst Immunity AC Power Port ±1kV EN61000-4-4: 2012, Criteria A Surge Immunity AC Power Port L-N ±1kV EN61000-4-5: 2014, Criteria B Immunity to conducted disturbances, induced by radio- frequency fields AC Power Port 3V EN61000-4-6: 2014, Criteria A Voltage Dips and Interruption Voltage Dips >95% Voltage Dips 30% Voltage Interruptions >95% EN61000-4-11: 2004, Criteria A EN61000-4-11: 2004, Criteria A EN61000-4-11: 2004, Criteria C

Packaging Dimension (LxWxH) tube 505.0 x 39.7 x 23.2mm Packaging Quantity 20pcs Storage Temperature Range -40°C to +100°C Storage Humidtiy non-condensing 5% - 95% RH max. 37.0

25.40 Recommended Footprint Details:

5.08 0.60 3.26 5.08 24.0 3.11 2.54 2.54 restricted area for PCB layout 17.78 15.03.5 embossed logo Dimension Drawing (mm) PA-5REV.: 2/2017www.recom-power.com AC/DC Converter Specifications (measured @ ta=25°C, nom. Vin, full load unless otherwise noted) RAC03-GB Series Pin Connections Pin # Single

1 VAC in (L)

2 VAC in (N)

NC: not connected Tolerance: XX.X ±0.5mm Pin Width: XX.X ±0.05mm The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.