RAC02E-K RECOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

Features

  • 85 to 305VAC input voltage range
  • 4kVAC isolation strength
  • Operating temperature: -40°C to +90°C
  • Full load output power up to 80°C
  • Low profile of 15.4mm
  • Standby mode optimized for Ecodesigns
  • EMC compliance EN55032 class “B”

Description

The cost-efficient RAC02E-K/277 AC/DC converter series has an input range of nominal 100VAC to an enhanced 277VAC, delivering an uncompromising 2 watts of output power with tightly regulated outputs from 3.3V to 24VDC. These low profile, encapsulated print-mountable modules in an industry-standard pinout deliver full output power from -40°C to +80°C and are certified for operation up to +90°C air ambient with output power reduced to 1.2W. This series of AC/DC modules holds international safety certifications for industrial, domestic, ITE, use with 4kVAC input to output isolation, they are suitable for worldwide applications in automation control, industry 4.0, IoT. Due to their LPS (Limited Power Source) and reinforced class II installation rating for floating outputs and their significantly wide margin to class B EMC compliance without external components, these are the easiest to use, versatile power modules in the industry.

2 Watt

1.35” x 0.88” Single Output Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Model Numbering Singlenom. Output Power nom. Output Voltage RAC02E- SK/277 Selection Guide Part Number Input Voltage Range [VAC] nom. Output Voltage [VDC] Output Current [mA] Efficiency typ. (1) [%] RAC02E-3.3SK/277 85-305 3.3 600 68 RAC02E-05SK/277 85-305 5 400 72 RAC02E-12SK/277 85-305 12 167 73 RAC02E-15SK/277 85-305 15 133 75 RAC02E-24SK/277 85-305 24 83 78 ERP compliant RECOMCONVERTERS COM PLIANT PRODUCTS REACH compliant RECOMCONVERTERS COM PLIANT PRODUCTS RoHS compliant 10 from 10 E227436 UL/IEC/EN62368-1 certified CAN/CSA C22.2 No. 62368-1 certified EN62233 (pending) IEC/EN61558-1/2-16 (pending) EN55032/EN55035 compliant CB Report BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Nominal Input Voltage 50/60Hz 100VAC 277VAC Operating Range (2, 3) 47-63Hz DC 85VAC 120VDC 277VAC 305VAC 430VDC Input Current 115VAC 230VAC 277VAC 60mA 40mA 30mA Inrush Current cold start at 25°C 115VAC 230VAC 277VAC 10A 20A 25A No load Power Consumption 75mW ErP Standby Mode Conformity (Maximum output power available for stated maximum input power) Input Power= 0.5W 1.0W 0.32W 0.67W continued on next page Notes: Note2: The products were submitted for safety files at AC-Input operation. (90-305VAC) Note3: Refer to “Derating Graph (7)” Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)

www.recom-power.com REV.: 0/2021 PA-2 AC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC02E-K/277 Series BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Input Frequency Range AC Input 47Hz 63Hz Minimum Load 0% Power Factor 115VAC 230VAC 277VAC 0.55 0.45 0.4 Start-up Time 15ms Rise Time 10ms Hold-up Time 115VAC 230VAC 277VAC 15ms 80ms 120ms Internal Operating Frequency 100% load at nominal Vin 132kHz Output Ripple and Noise (4) 20MHz BW 3.3, 5Vout others 120mVp-p 1% of Vout continued on next page Efficiency vs. Load RAC02E-12SK/277 / RAC02E-24SK/277 RAC02E-3.3SK/277 RAC02E-15SK/277 RAC02E-05SK/277 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 110VAC 230VAC 277VAC 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 110VAC 230VAC 277VAC 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 110VAC 230VAC 277VAC 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 110VAC 230VAC 277VAC Notes: Note4: Measurements are made with a 0.1µF MLCC & 10µF E-cap in parallel across output. (low ESR)

www.recom-power.com REV.: 0/2021 PA-3 AC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC02E-K/277 Series REGULATIONS Parameter Condition Value Output Accuracy 3.3, 5Vout others ±2.0% typ. ±1.0% typ. Line Regulation low line to high line, full load ±0.5% typ. Load Regulation (5) 10% to 100% load 0.5% typ. Transient Response 10% load step change recovery time 6.0% max. 350µs max. Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met Deviation vs. Load RAC02E-3.3SK/277 RAC02E-05SK/277 1.0 0.5 -0.5 0.75 0.25 -0.25 -0.75 -1.0 Deviation [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] Deviation [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] 1.0 0.5 -0.5 0.75 0.25 -0.25 -0.75 -1.0 RAC02E-12SK/277 / RAC02E-24SK/277 RAC02E-15SK/277 Deviation [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] 1.0 0.5 -0.5 0.75 0.25 -0.25 -0.75 -1.0 Deviation [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] 1.0 0.5 -0.5 0.75 0.25 -0.25 -0.75 -1.0 PROTECTIONS Parameter Type Value Input Fuse internal fusible resistor Short Circuit Protection (SCP) Hiccup mode, auto recovery Over Voltage Protection (OVP) 120% - 260%, hiccup mode Over Current Protection (OCP) 120% - 300%, hiccup mode Over Voltage Category (OVC) OVCII Isolation Voltage (6) I/P to O/P 1 minute 4kVAC continued on next page Notes: Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage

www.recom-power.com REV.: 0/2021 PA-4 AC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC02E-K/277 Series PROTECTIONS Parameter Condition Value Isolation Resistance I/P to O/P , Isolation Voltage 500VDC 1GΩ min. Isolation Capacitance I/P to O/P , 100KHz/0.1V 100pF max. Leakage Current @ 277VAC 0.25mA max. Insulation Grade reinforced ENVIRONMENTAL Parameter Condition Value Operating Temperature Range @ natural convection 0.1m/s refer to “Derating Graph (7)” -40°C to +85/90°C Maximum Case Temperature +95°C Temperature Coefficient ±0.03%/K Operating Altitude 2000m Operating Humidity non-condensing 20% - 90% RH max. Pollution Degree PD2 Vibration 10-500Hz, 2G 10min./1cycle, period 60min. each along x,y,z axes MTBF according to MIL-HDBK-217F, G.B. +25°C +40°C 1850 x 103 hours 1510 x 103 hours Design Lifetime 230VAC/60Hz and full load +50°C >30 x 103 hours -40 -20-30 -10 0 2010 30 5040 60 70 80 90 8565 75 100 100 Output Load [%] Ambient Temperature [°C] 115-240VAC nom. 100VAC nom. Derating Graph (7) (@ Chamber and natural convection 0.1m/s) othersRAC02E-3.3SK/277 -30-40 -20 -10 0 2010 30 5040 60 70 80 90 100 100 Output Load [%] Ambient Temperature [°C] 115-240VAC nom. 100VAC nom. Notes: Note7: Output power derating for Line-input of less than 90VAC (derate linearly from 100% at 90VAC to 85% at 85VAC)

www.recom-power.com REV.: 0/2021 PA-5 AC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC02E-K/277 Series SAFETY AND CERTIFICATION Certificate Type (Safety) Report Number Standard Audio/Video, information and communication technology equipment - Part 1: Safety requirements E491408-A6014- UL UL62368-1:2019 3rd Edition CAN/CSA-C22.2 No. 62368-1:2019 Audio/Video, information and communication technology equipment - Safety requirements (CB Scheme) 200703001-1 IEC62368-1:2018 3rd Edition Audio/Video, information and communication technology equipment - Safety requirements (LVD) EN IEC 62368-1:2020+A11:2020 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure (pending) EN62233:2008 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1100 V (CB Scheme) (pending) IEC61558-1:2005 2nd Edition + A1:2009 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1100 V (pending) EN61558-1:2005 + A1:2009 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1100 V Part 2: Particular requirements (CB Scheme) (pending) IEC61558-2-16:2009 1st Edition + A1:2013 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1100 V Part 2: Particular requirements (pending) EN61558-2-16:2009 + A1:2013 RoHS2 RoHS 2011/65/EU + AM2015/863 EMC Compliance (Industrial) Condition Standard / Criterion Electromagnetic compatibility of multimedia equipment – Emission Requirements EN55032:2015, Class B Electromagnetic compatibility of multimedia equipment – Immunity requirements EN55035:2017 ESD Electrostatic discharge immunity test Air: ±2, 4 ,8kV; Contact: ±4kV IEC61000-4-2:2008 , Criteria B EN61000-4-2:2009, Criteria B Radiated, radio-frequency, electromagnetic field immunity test 3V/m: 80-1000MHz, 1800MHz, 2600MHz, 3500MHz, 5000MHz IEC/EN61000-4-3:2006 + A2:2010, Criteria A Fast Transient and Burst Immunity AC Port: ±1kV IEC/EN61000-4-4:2012, Criteria B Surge Immunity AC Port: ±1kV IEC/EN61000-4-5:2014, Criteria B Immunity to conducted disturbances, induced by radio-frequency fields 3Vrms: 0.15-10MHz 3-1Vrms: 10-30MHz 1Vrms: 30-80MHz IEC61000-4-6:2013/EN6100-4-6:2014, Criteria A IEC61000-4-6:2013/EN6100-4-6:2014, Criteria A IEC61000-4-6:2013/EN6100-4-6:2014, Criteria A Power Magnetic Field Immunity IEC61000-4-8:2009 EN61000-4-8:2010 Voltage Dips and Interruptions IEC/EN61004-11:2004 Limits of Harmonic Current Emissions IEC/EN61000-3-2:2019 Limits of Voltage Fluctuations & Flicker Clause 5 EN61000-3-3:2013+A1 Limitations on the amount of electromagnetic interference allowed from digital and electronic devices FCC 47 CFR Part 15 Subpart B, Class B DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case/baseplate potting PCB black plastic, (UL94 V-0) silicone, (UL94 V-0) FR4, (UL94 V-0) Dimension (LxWxH) 33.7 x 22.2 x 15.4mm Weight 18.4g typ. continued on next page

www.recom-power.com REV.: 0/2021 PA-6 AC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC02E-K/277 Series Dimension Drawing (mm) Recommended Footprint Details Pinning Information Pin # Single

1 VAC in (L)

2 VAC in (N)

General tolerances according to ISO 2768-m (table for reference only) Dimension range 0.5 - 6 mm 6 - 30 mm 30 - 120 mm 120 - 400 mm Tolerances ±0.1 mm ±0.2 mm ±0.3 mm ±0.5 mm PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 490.0 x 36.3 x 26.3mm Packaging Quantity 20pcs Storage Temperature Range -40°C to +85°C Storage Humidity non-condensing 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. 2 3 33.7 33.1 21.6 2.54 2.54 Bottom View 15.4 Ø0.60±0.1 3.50 7.62 2.85 27.94 15.24 22.2 embossed logo 4.00±1.0