RAC02-SE-277 RECOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Features
- 35mW max. No Load Power Consumption
- Efficiency up to 76%
- Isolated Output 3kVAC / 1 min
- SCP, OVP Protection
- Wide Operating Temperature Range: -40°C to +85°C
- Universal Input 85-305VAC
2 Watt
Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ. Load (1) (VAC) (VDC) (mA) (%) (µF) RAC02-3.3SE/277 85-305 3.3 600 67 12000 RAC02-05SE/277 85-305 5.0 400 70 5500 RAC02-12SE/277 85-305 12 167 73 500 RAC02-24SE/277 85-305 24 83 76 160 Notes: Note2: Ripple and Noise is the maximum peak-to-peak voltage value measured at the output with a 20MHz bandwidth, at rated line voltage at full load. And with a 47µF low-ESR electrolytic capacitor in parallel with a 0.1µF ceramic capacitor across output. Notes: Note1: Test by minimum input and constant resistor load. EN55024 Certified EN60950-1 Certified UL60950-1 Certified E224736
PA-2 REV.: 4/2016 www.recom-power.com AC/DC Converter PROTECTIONS Parameter Type Value Short Circuit Protection (SCP) continuous, automatic recovery Over Voltage Protection (OVP) Zener Diode clamp 110% - 140% Over Current Limit 110% - 190% Isolation Voltage 3kVAC / 1 Minute Isolation Resistance 1GΩ min. Leakage Current 85-305VAC, 47-440Hz 10µA max. Specifications (measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up) REGULATIONS Parameter Condition Value Output Voltage Tolerance (3) ±6% max. Line Voltage Regulation low line to high line, full load ±1.5% max. Load Voltage Regulation 2% to 100% load ±6% typ. RAC02-SE/277 Series Notes: Note3: Includes initial voltage accuracy, thermal drift, line regulation and load regulation at rated input voltage and load conditions. Notes: Note4: An input fuse is recommended: T1A slow blow type. Note5: An external MOV is required. The Varistor should comply with IEC-61051-2. e.g. EPCOS S14 Series RAC02-05SE/277MOV FUSE L N VACin (L) VACin (N) -Vout +Vout Efficiency vs. Load 115VAC 230VAC 277VAC 0.3 0.40 0.1 0.2 Efficiency (%) Output Current (A) RAC02-05SE/277
PA-3REV.: 4/2016www.recom-power.com AC/DC Converter ENVIRONMENTAL Parameter Condition Value Operating Temperature Range 230VAC, with derating (see graph) -40°C to +85°C Maximum Case Temperature +105°C Thermal Impedance 8.5°C/W typ. Humidity non-condensing 5% - 95%, RH max. MTBF (6) MIL-HDBK-217F, 115VAC, +25°C MIL-HDBK-217F, 230VAC, +25°C 2238 x 103 hours 1670 x 103 hours -40 60 70 75 80 90 10050403020100-20 -25 100 Ambient Temperature (°C) Output Power (%) Output Power (%) @ 85-140VAC 3.3V and 5V all other models -40 60 70 90 10050403020100-20 100 Ambient Temperature (°C) @ 140-305VAC all models Derating Graph Specifications (measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up) RAC02-SE/277 Series Notes: Note6: MTBF is referring RAC02-05SE/277 SAFETY AND CERTIFICATIONS Certificate Type Report / File Number Standard EN General Safety SPCLVD1208051 EN-60950-1, 2nd Edition UL General Safety E224736-X1-A24 UL-60950-1, 2nd Edition, 2014 Canada General Safety E224736-X1-A24 CAN/CSA C22.2 No. 60950-1-07, 2nd Edition 2014 Certificate Type (Environmental) Report / File Number Standard / Criterion ESD Radiated Immunity Fast Transient Surge Conducted Immunity Power Magnetic Field Voltage Dips and Interruption Voltage flicker ±8kV Air Discharge; ±6kV Contact 3V/m AC Power Port: ±1kV AC Power Port: line to line: ±1kV AC Power Port: 3V/m
1 A/m
Voltage Dips: >95% reduction >30% reduction Interruption: >95% . EN61000-4-2, Criteria B EN61000-4-3, Criteria A EN61000-4-4, Criteria B EN61000-4-5, Criteria B EN61000-4-6, Criteria A EN61000-4-8, Criteria A EN61000-4-11, Criteria B EN61000-4-11, Criteria C EN61000-4-11, Criteria C EN61000-3-3 EMI Standard Report: 1502CE17 EN55022, Class B EN55024 Vibration MIL-STD-202G Over Voltage Category OVC II
PA-4 REV.: 4/2016 www.recom-power.com AC/DC Converter Specifications (measured at TA= 25°C, nominal input voltage (115/230VAC), full load and after warm-up) RAC02-SE/277 Series The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Case Material Potting Material UL94V-0, black plastic UL94V-0, Silicone Package Dimension (LxWxH) 33.7 x 22.2 x 17.75mm Package Weight 24.5g typ. PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) Tube 520 x 37 x 28mm Packaging Quantity 22 pcs. Storage Temperature Range -40°C to +85°C Bottom View 33.7 7.0 tc18.0 Ø 0.8±0.1 28.0 15.24 7.62 22.2 6.1 0.75 ±0.25 17.75 ±0.25 5.0 embossed logo Pin Connections Pin # Single
1 VAC in (N)
2 VAC in (L)
Tolerance: xx.x= ±0.5mm xx.xx= ±0.35mm Pin width: ±0.05mm Dimension Drawing (mm)