Features

  • Up to 488VAC input voltage r ange
  • 9A current r ating for up 90°C air temperature
  • UL Listed components used
  • Stable solderability b y secure packaging
  • Clearances for oper ating altitude up to 5000m Adapter Board for RECOM AC/DC converters RAC-ADAPT-ST-1

Description

The RAC-ADAPT-ST-1 is an adapter board which allows many of RECOM’s latest AC-DC products in the range of 1 to 20 Watts of output power to be fitted with screw terminals for easy connection. Although RECOM’s AC-DC modules come equipped with integrated fuses and already meet high immunity levels, space on the board is provided for optional MOV and fusing if preferred. The product comes in a sealed package with a drying agent to ensure long term solderability. Wide input voltage and wide ambient operating temperature ratings of the design and appropriate clearance make it an easy-to-use board for short run or low-volume production and prototyping as well as for evaluation purposes. Compatible converters Converter Input Voltage Range nom. Output V oltages Internal Converter Series [VAC] [VDC] Fuse Link RAC01-GA 85-264 5, 12 fusible resistor RAC01-GA.pdf RAC01-GB 85-264 3.3, 5, 12, 24 fusible resistor RAC01-GB.pdf RAC02-GA 85-264 3.3, 5, 12, 15, 24 fusible resistor RAC02-GA.pdf RAC02-GB 85-264 3.3, 5, 12, 15, 24 fusible resistor RAC02-GB.pdf RAC03-K 85-264 3.3, 5, 12, 15, 18, 24 fusible resistor RAC03-K.pdf RAC03-GA 85-264 3.3, 5, 12, 15, 24 T1A RAC03-GA.pdf RAC03-GB 85-264 3.3, 5, 9, 12, 15, 24 T1A RAC03-GB.pdf RAC04-GA 85-305 3.3, 5, 9, 12, 15, 24 T1A RAC04-GA.pdf RAC04-GB 85-264 3.3, 5, 9, 12, 15, 24 T1A RAC04-GB.pdf 12, 15, 24 T1A RAC3.5-K/277.pdf RAC05-K/277 85-305 3.3, 5, 12, 15, 24 T1A RAC05-K/277.pdf RAC05-K/480 85-528 5, 12 fusible resistor RAC05-K/480.pdf RAC10-K/277 85-305 3.3, 5, 12, 15, 24, ±12, ±15 T2A RAC10-K/277.pdf RAC15-K 85-264 5, 12, 15, 24 T3.15A RAC15-K.pdf RAC20-K 85-264 5, 12, 15, 24, 48, ±12, ±15 T3.15A RAC20-K.pdf

ELECTRICAL CHARACTERISTICS

Parameter Condition Min. Typ. Max. Absolute Maximum Input Voltage 3000m 488VAC 690VDC 5000m 329VAC 465VDC Input Current TAMB= 90°C 9A Input Fuse Placeholder (1) 5.08mm pitch package for radial leaded fuse with hole size 0.9mm Varistor Placeholder (2) 7.5mm/3.5mm pitch Notes: Note1: Refer to local safety regulations if input over -current protection is also required RECOM suggests: Littlefuse 369 series Note2: If V aristor is installed, input fuse is always mandatory RECOM suggests: EPCOS S14 series

www.recom-power.com REV.: 0/2019 P-2 Accessory Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC-ADAPT-ST-1 DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Dimension (LxWxH) 91.0 x 50.0 x 14.0mm Weight 19g typ. Dimension Drawing (mm) Snap-on stop spacer suggestion (Model: Wuerth 709440800) +Vout-Vout COM FUSEAC 1 2 3 4 5 6 91.0 4x M3 FC 85.0 FC 45.0 3.5 5.08 7.5 50.0>14.0 11.6 10.011.0 10.014.0 1.6 Ø0.9 Ø1.05 VAR 1.80.75 Drilling in Panel Ø3.0 Panel Thickness 1.6 Drilling in Panel Ø4.0 Panel Thickness 0.8~1.6 Screw Terminal Information # Function recommended Wire 1 FUSE 16AWG 1-1.5mm² 2 VAC 16AWG 1-1.5mm² 3 VAC 16AWG 1-1.5mm² Output Screw Terminal # Function recommended Wire 4 -Vout 16AWG 1-1.5mm² 5 COM 16AWG 1-1.5mm² 6 +Vout 16AWG 1-1.5mm² wire stripping length: 6mm recommended tightening torque: 0.6Nm max. NC= no connection FC= fixing centres Tolerance: xx.x= ±0.5mm xx.xx= ±0.25mm Notes: Note3: If spacers are needed, RECOM sug gests to use Wuerth 70944xx00 series or similar)

www.recom-power.com REV.: 0/2019 P-3 Accessory Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC-ADAPT-ST-1 INSTALLATION AND APPLICATION continued on next page Layout Top Layer Bottom Layer Schematic -Vout +Vout +Vout COM COM VACin (L) VACin(N) -Vout U F VACIN (L) VACIN (L) VACIN (N) Notes: Note4: User must ensure adequate isolation between bottom of RAC-ADAPT-ST-1 board and any conductive surfaces

www.recom-power.com REV.: 0/2019 P-4 Accessory Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC-ADAPT-ST-1 INSTALLATION AND APPLICATION PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) moisture barrier bag 155.0 x 125.0 x 22.0mm Packaging Quantity 1pcs Storage Temperature Range -30°C to +90°C The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. Application Circuits module with internal fuse, single output module with external fuse, single output module with internal fuse, dual output module with external fuse, dual output NC +Vout +Vout COM COM VACin (L) VACin(N) NC VACIN (L) NC VACIN (N) -Vout +Vout +Vout COM COM VACin (L) VACin(N) -Vout VACIN (L) NC VACIN (N) NC out +Vout COM COM VACin (L) VACin(N) NC U F NC VACIN (L) VACIN (N) -Vout +Vout +Vout COM COM VACin (L) VACin(N) -Vout U F NC VACIN (L) VACIN (N) NC out +Vout COM COM VACin (L) VACin(N) NC VACIN (L) NC VACIN (N) -Vout +Vout +Vout COM COM VACin (L) VACin(N) -Vout VACIN (L) NC VACIN (N) NC out +Vout COM COM VACin (L) VACin(N) NC U F NC VACIN (L) VACIN (N) -Vout +Vout +Vout COM COM VACin (L) VACin(N) -Vout U F NC VACIN (L) VACIN (N) NC out +Vout COM COM VACin (L) VACin(N) NC VACIN (L) NC VACIN (N) -Vout +Vout +Vout COM COM VACin (L) VACin(N) -Vout VACIN (L) NC VACIN (N) NC out +Vout COM COM VACin (L) VACin(N) NC U F NC VACIN (L) VACIN (N) -Vout +Vout +Vout COM COM VACin (L) VACin(N) -Vout U F NC VACIN (L) VACIN (N) NC out +Vout COM COM VACin (L) VACin(N) NC VACIN (L) NC VACIN (N) -Vout +Vout +Vout COM COM VACin (L) VACin(N) -Vout VACIN (L) NC VACIN (N) NC out +Vout COM COM VACin (L) VACin(N) NC U F NC VACIN (L) VACIN (N) -Vout +Vout +Vout COM COM VACin (L) VACin(N) -Vout U F NC VACIN (L) VACIN (N) Note: The usage of a cable strain relief is strongly recommended.