R82 MAGNETROL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

Introducing Full-featured Level Transmitters with a User-friendly Price Point. 355 U L T R A S O N I C R82 R A D A R Worldwide Level and Flow Solutionssm M O D E L M O D E L ANOTHER INNOVATION FROM

TOP LEFT: Cast aluminum with a tempered glass window for XP approval. TOP RIGHT: Lexan® plastic with a transparent cover. Electronics Module ABOVE: Module as positioned in compartment shows LCD and four-button keypad. Housing Compartment Shown in aluminum; available in Lexan. Contains field wiring compartment and electronics. O-Ring Aluminum Housing: Viton® Lexan® Housing: Buna-N Echotel® Model 355is a two-wire, loop-powered, non-contact ultrasonic transmitter that performs liquid level, volume, and open channel flow measurement. A powerful 60 kHz ultrasonic transducer and advanced digital signal processing is featured to reliably measure out to a 20 foot (6 meter) maximum range. The Model 355 provides unsur- passed ease of configuration with either the menu-driven 4-pushbut- ton, 2-line× 16-character display, HART ® digital communications, or PACTware ™ . The latter enables a complete configuration via the local user interface, or remotely with the added capability of capturing echo waveforms, and viewing trend data, diagnostic conditions and all trans- mitter configuration parameters. Operating Principle Measurement is obtained by emitting an ultrasonic pulse from the transducer and measuring the time required for the echo to reflect from the liquid surface and return to the transducer. U L T R A S O N I C T R A N S M I T T E R The Model 355 with a Lexan® housing and polypropylene transducer; and a 355 with an XP aluminum housing and a Kynar® transducer. Piezoelectric Crystal Assembly Transducer Board TransducerShown in Kynar; available in polypropylene.

The intelligent electronics of the Model 355 Transmitter analyze the ultrasonic echo profile, apply temperature compensation, reject echoes from false targets, and then processes the true echo from the liquid surface. This results in an extremely reliable measurement even when application difficulties exist like turbulence or false echoes generated by agitator blades, fill pipes or other internal tank fittings. The 60 kHz ultrasonic transducer is offered in polypropylene or Kynar for superior performance in harsh environments. These powerful transducers feature a 10° conical beam and 10" (255 mm) blocking distance to maximize measurement capabilities in a wide variety of applications.

  • Chemical storage tanks
  • Vessels with highly viscous media
  • Paint, ink and solvent tanks
  • Food and beverage vessels
  • Batch and day tanks
  • Open channel flow weirs and flumes

355 Ultrasonic Transmitter

Overcomes Measurement Difficulties The sophisticated circuitry of the R82 transmits, receives and processes 1.8 million pulses per second to ensure reliable measurement. The R82 measures effectively even when atmospheres above the liquid are saturated with vapor. Pulse Burst technology and advanced signal processing manage common disturbances such as false echoes caused by obstructions, multi-path reflections from tank sidewalls or turbulence caused by agitators, aggressive chemicals, or aerators. The R82 launcher orientation and echo-rejection profiling are simplified for easy use. The microwave beam is rotatable for optimized operation. The fully- encapsulated horn antenna offers high performance and is chemically resistant to nearly all standard process media. Applications include:

  • Liquids, slurries and viscous media
  • General chemical storage
  • Day, batch and feed tanks
  • Food and beverage vessels
  • Water/Wastewater tanks and sumps R82 Radar Transmitter Agitator blade shaft Fill pipe Turbulent process Ladder and fill pipe obstacles Visible vapors Aerated process; in-tank air movement

TOP LEFT: Cast aluminum with a tempered glass window. TOP RIGHT: Lexan plastic with a transparent cover. Electronics Module ABOVE: Module as positioned in compartment shows LCD and four-button keypad. Radome Sheds condensation Housing Compartment Shown in aluminum; available in Lexan. Contains field wiring compartment and electronics. Model R82is a loop-powered,

26 GHz, non-contact radar transmitter

that performs liquid level and volume measurements in enclosed vessels. The R82 offers high-performance at an economical price point to reliably measure out to a 40 foot (12 meter) maximum range. The Model R82 provides unsurpassed ease of configuration with either the menu-driven 4-pushbutton, 2-line× 16-character display, HART digital communications, or PACTware. This allows complete configuration via the local user interface, or remotely with the added capability of capturing echo waveforms, and viewing trend data, diagnostic conditions and all transmitter configuration parameters. Model R82 with a thermoplastic housing and a polypropylene antenna; and a Model R82 with a cast aluminum housing and a Tefzel® antenna Radar Antenna Shown in Tefzel; available in polypropylene. Available in two lengths. Antennahorn is encapsulated within polypropylene or Tefzel. Operating PrincipleThe R82 is based on pulse burst radar technology together with equivalent time sampling circuitry. Short bursts of

26 GHz microwave energy

are emitted and subsequently reflected from the liquid level surface. ) ) ) ) R82 R A D A R T R A N S M I T T E R O-Ring Aluminum Housing: Viton® Lexan® Housing: Buna-N

A P P L I C A T I O N S U I T A B I L I T Y MEASUREMENT CAPABILITY Level, Volume, or Open Channel Flow Level or Volume VESSEL TYPES Open or Closed Closed only VOLUME Selectable from stored tank shapes Utilizes 20-point table RANGE 13" to 20 feet (0.3 to 6 meters)Recommended Recommended 20 to 40 feet (6 to 12 meters) Not Recommended Recommended NARROW SHOT w/ OBSTRUCTIONS Recommended Not Recommended PLASTIC STILLWELL Recommended Not Recommended STEEL STILLWELL Recommended Recommended TEMPERATURE GRADIENTS Not Recommended Recommended PRESSURE Vacuum Not Recommended Recommended Atmospheric Recommended Recommendedto 43.5 psig (3 bar) 43.5 psig (3 bar) Not Recommended Recommendedto 200 psig (13.8 bar) VAPORS Not Recommended Recommended AGGRESSIVE MEDIA Recommended with Kynar® transducer Recommended with Tefzel® antenna CO 2 GAS Not Recommended Recommended HYGIENIC, CIP/SIP APPLICATIONS Not Recommended Recommended

CORPORATE HEADQUARTERS: EUROPEAN HEADQUARTERS: U.S.A. 5300 Belmont Road• Downers Grove, Illinois 60515-4499 BELGIUM: Heikensstraat 6• 9240 Zele, Belgium Phone: 630-969-4000 • Fax: 630-969-9489 Phone: 052 45.11.11• Fax: 052 45.09.93 info@ magnetrol.com • www.magnetrol.com Echotel is a registered trademark of Magnetrol International. HART is a registered trademark of The HART Communication Foundation. Lexan is a registered trademark of SABIC Innovative Plastics. PACTware is a trademark of the PACTware Consortium. Kynar is a registered trademark of Atofina. Tefzel is a registered Bulletin: 41-231.1• Effective: September 2009 Worldwide Level and Flow SolutionsSM PERFORMANCE Linearity±0.2 inch (±5 mm) or 0.05% of tank height (whichever is greater) Measured ErrorSame as above Repeatability< 0.1" (2.5 mm) or 0.03% of tank height Response Time< 1 second Maximum Rate of Change180" (460 cm)/minute Minimum Dielectric1.7 FUNCTIONAL Measurement PrinciplePulse Burst Radar at 26 GHz Range 15 inches to 40 feet (0.4 to 12 meters) Output RangeAnalog 3.8 to 20.5 mA useable (NAMUR 43); with HART Loop ResistanceGP/IS: 400Ω@ 24 VDC/20 mA, 350Ω @ 24 VDC/22 mA Damping Adjustable 0-45 units Output @ Antenna< 0.01 mW (avg.), < 2 mW (max.) Keypad 4-button menu-driven data entry and system security Indication2-line× 16-character LCD Power GP/IS16 to 36 VDC Housing MaterialLexan base and cover; Cast aluminum A356T6 (<0.2% copper) Cable EntryTwo 3⁄4" NPT or M20 entries Ingress ProtectionType 6P (IP 68) – Aluminum housing AntennaEncapsulated horn, polypropylene, Tefzel (optional) -40° to +200° F @ atmos (-40° to 95° C) Wetted SurfacesPolypropylene or Tefzel PHYSICAL Operating Temperature-40° to +175° F (-40° to +80° C) Operating PressureVacuum to 200 psig @ +70° F (-1 to 13.8 bar) – Tefzel Humidity0 to 99%, non-condensing S P E C I F I C A T I O N S

355 R82

Linearity±0.4" (±10 mm) Resolution0.1" (2.5 mm) Repeatability±0.125" (±3 mm) Response Time<1 second Warm-up Time 30 seconds FUNCTIONAL Measurement PrincipleNon-Contact Ultrasonic Transducer Frequency60 kHz Range 13 inches to 20 feet (0.3 to 6.0 meters) Output RangeAnalog 3.8 to 20.5 mA useable (NAMUR 43); with HART Loop ResistanceGP/IS: 400Ω@ 24 VDC/20 mA, 350Ω @ 24 VDC/22 mA Damping 1–60 units Keypad 4-button menu-driven data entry and system security Indication2-line x 16-character LCD Power XP & GP: 16 to 36 VDC IS: 16 to 28.6 VDC Housing MaterialLexan base and cover; Cast aluminum A356T6 (<0.2% copper) Cable EntryTwo 3⁄4" NPT or M20 entries Ingress ProtectionType 6P (IP 68) – Aluminum housing TransducerEncapsulated piezoelectric crystal, polypropylene, Kynar (optional) Wetted SurfacesPolypropylene or Kynar (PVDF) PHYSICAL Operating Temperature-40° to +175° F (-40° to +80° C) Operating Pressure0 to 43.5 psig (0 to 3 bar) Humidity0 to 99%, non-condensing