R2SX RECOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

Features

  • 2 Watt power supply in SMD package
  • -40°C to +100°C operating temperature
  • 3kVDC/1 second or 1kVDC/1 second isolation
  • No minimum load required
  • IEC/EN/UL62368-1 certified, CB Report

Description

The R2SX is a low profile, open-frame 2W SMD isolated DC/DC converter with either 3kVDC/1 second isolation (/H version) or 1kVDC/1 second isolation options. There is no minimum load requirement and the efficiency stays high over a wide 20% to 100% load range. The operating temperature is from -40°C up to +75°C at full load, and up to +100°C with derating. The converters are fully certified to IEC/EN/UL62368-1 and are 10/10 RoHS-conform. A simple low cost LC filter is all that is needed for Class B EMC compliance. The R2SX comes with a 3-year warranty. E224736 UL62368-1 certified CAN/CSA-C22.2 No. 62368-1-14 certified UL60950-1 certified CAN/CSA-C22.2 No. 60950-1-07 certified IEC/EN62368-1 certified EN55032 compliant EN55024 compliant CB report Selection Guide Part nom. Input Output Output Efficiency max. Capacitive Number Voltage Voltage Current typ. (1) Load (2) [VDC] [VDC] [mA] [%] [µF] R2SX-053.3 5 3.3 606 79 3300 R2SX-0505 5 5 400 81 3300 R2SX-2405 24 5 400 85 3300 R2SX-2415 24 15 133 85 680 R2SX-2424 24 24 84 86 220 Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resistive load Notes: Note3: without suffix, standard isolation voltage (1kVDC/1 second) with suffix „/H“, high isolation voltage (3kVDC/1 second) Note4: with suffix „-R“, standard packaging tape and reel with suffix „-Tray“ for optional tray packaging Model Numbering Packaging (4) Isolation Voltage (3) Output Voltage Output Power Single nom. Input Voltage Ordering Examples: R2SX-0505-R 5Vin 5Vout Single Output 1kVDC/1 second isolation tape and reel packaging R2SX-2424/H-R 24Vin 24Vout Single Output 3kVDC/1 second isolation tape and reel packaging R2SX-2424/H-Tray 24Vin 24Vout Single Output 3kVDC/1 second isolation tray packaging

www.recom-power.com REV.: 0/2019 ECO-2 DC/DC Converter Specifications (measured @ Ta= 25°C, nominal input voltage, full load unless otherwise specified) R2SX Series BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter capacitor Input Voltage Range ±10.0% Input Current nom. Vin = 5VDC nom. Vin = 24VDC 500mA 100mA Quiescent Current nom. Vin = 5VDC nom. Vin = 24VDC 40mA 15mA Minimum Load 0% Internal Operating Frequency 20kHz Output Ripple and Noise (5) 20MHz BW 150mVp-p Efficiency vs. Load R2SX-053.3S(/H) R2SX-2405S(/H) R2SX-0505S(/H) R2SX-2424S(/H) 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] Notes: Note5: Measurements are made with a 0.1µF MLCC across output. (low ESR)

www.recom-power.com REV.: 0/2019 ECO-3 DC/DC Converter Specifications (measured @ Ta= 25°C, nominal input voltage, full load unless otherwise specified) R2SX Series REGULATIONS Parameter Condition Value Output Accuracy ±5.0% max. Line Regulation low line to high line ±1.2% typ. at 1.0% of Vin typ. Load Regulation (6) 10% to 100% load 3.3Vout, 5Vout 15Vout, 24Vout 15.0% max. 10.0% max. Notes: Note6: Operation below 10% load will not harm the converter, but specifications may not be met Tolerance Envelope R2SX-05xx(/H) R2SX-24xx(/H) +10% +5% Vnom +5% -0.5% -5% Output Voltage [%] 10 50 100 Output Load [%] Typical Load Line +15% +9% Vnom +5% -1.5% -5% Output Voltage [%] 10 50 100 Output Load [%] Typical Load Line PROTECTIONS Parameter Type Value Isolation Voltage I/P to O/P standard tested for 1 second rated for 1 minute (7) 1kVDC 500VAC I/P to O/P with suffix “/H” tested for 1 second rated for 1 minute (7) 3kVDC 1.5kVAC Isolation Resistance 10GΩ min. Isolation Capacitance 100pF max. Insulation Grade functional Notes: Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note8: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type

www.recom-power.com REV.: 0/2019 ECO-4 DC/DC Converter Specifications (measured @ Ta= 25°C, nominal input voltage, full load unless otherwise specified) R2SX Series ENVIRONMENTAL Parameter Condition Value Operating Temperature Range @ natural convection and full load (refer to derating graph) -40°C to +75°C Operating Altitude 5000m Operating Humidity non-condensing 5% - 95% RH max. Pollution Degree PD2 Vibration according to MIL-STD-202G MTBF according to MIL-HDBK-217F, G.B. +25°C +75°C 12100 x 10³ hours 4400 x 10³ hours Derating Graph (@ Chamber and natural convection 0.1m/s) -40 -20 0 20 40 7060-30 -10 10 30 50 80 90 75 85 110100 100 Output Load [%] Ambient Temperature [°C] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Audio/video, information and communication technology equipment - Safety requirements E224736 UL62368-1, 2nd Edition, 2014 CAN/CSA -C22.2 No. 62368-1-14, 2nd Edition Information Technology Equipment, General Requirements for Safety UL60950-1, 2nd Edition, 2014 CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition Audio/video, information and communication technology equipment - Safety requirements (CB Scheme) WD-ITAV-190016-A0 IEC62368-1:2014, 2nd Edition Audio/video, information and communication technology equipment - Safety requirements EN62368-1:2014 + A11:2017 RoHS2 RoHS 2011/65/EU + AM2015/863 continued on next page

www.recom-power.com REV.: 0/2019 ECO-5 DC/DC Converter Specifications (measured @ Ta= 25°C, nominal input voltage, full load unless otherwise specified) R2SX Series EMC Compliance Condition Standard / Criterion Electromagnetic Compatibility of Multimedia Equipment - Emission Requirements with external filter (see filter suggestion below) EN55032:2015 + AC:2016, Class B Information technology equipment - Immunity characteristics - Limits and methods of measurement WH-CE-E1803002 EN55024:2010 + A1:2015 ESD Electrostatic discharge immunity test Air: ±2, 4, 6, 8kV Contact: ±2, 4kV EN61000-4-2:2009, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 1, 3, 10V/m EN61000-4-3:2010, Criteria A Fast Transient and Burst Immunity DC Power Port: ±0.5, 1, 2kV EN61000-4-4:2012, Criteria A Surge Immunity DC Power Port: ±0.5, 1kV EN61000-4-5:2017, Criteria B Immunity to conducted disturbances, induced by radio-frequency fields 10V r.m.s EN61000-4-6:2014, Criteria A Power Magnetic Field Immunity 50Hz / 1A/m EN61000-4-8:2010, Criteria A EMC Filtering Suggestions for EN55032 -Vout +Vout -Vin +Vin +Vout+Vin -Vout-Vin Component List Class B Model C1 L1 C2 R2SX-05xx 10µF MLCC 10µH SMD Inductor 470pF/4kVDCR2SX-24xx 47µH SMD Inductor DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Material base PCB black plastic, (UL94V-0) FR4, (UL94V-0) Package Dimension (LxWxH) 15.24 x 11.1 x 8.0mm Package Weight 1.6g typ. continued on next page

www.recom-power.com REV.: 0/2019 ECO-6 DC/DC Converter Specifications (measured @ Ta= 25°C, nominal input voltage, full load unless otherwise specified) R2SX Series The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. Dimension Drawing (mm) Recommended Footprint Details Pin Connection Pin # Single 1 -Vin 2 +Vin 4 NC 5 -Vout 7 +Vout 10 NC CG= center of gravity NC= no connection Tolerance: xx.x= ±0.5mm xx.xx= ±0.25mmBottom View Top View 1 2 4 710 710 1 2 4 5 11.1 15.24 4 x 2.54= 10.16 10.7 12.07 0.25±0.10 8.0 max. 2.54 1.27 2.54 0.50±0.10 0.802.50 CG PACKAGING INFORMATION Packaging Dimension (LxWxH) tape and reel (carton) reel 355.0 x 340.0 x 35.0mm 330.2 x 330.2 x 30.0mm tray 260.0 x 205.0 x 27.0mm Packaging Quantity tape and reel 250pcs tray 30pcs Tape Width 24.0mm Storage Temperature Range non-condensing -55°C to +125°C Storage Humidity 5% - 95% RH max.