Features
- Regulated output with internal linear regulator
- Isolated 1W power in SMD package
- Up to 2kVDC isolation
- Industry standard pinout
- -40°C to +100°C operating temperature
- IEC/EN/UL62368-1 certified, CB report R1ZX
Description
The R1ZX is similar to the R1SX but with the addition of an internal linear regulator to give a precise, load-independent and low noise output. The output is also continuously short circuit protected. In the event of a continuous overload or over-temperature condition, the output will shut down thus protecting the converter from damage. The output will automatically restart once the fault condition has been lifted. Typical applications include isolated 5V supplies for sensor, bus-interface and test and measurement circuits. DC/DC Converter
1 Watt
CAN/CSA-C22.2 No. 62368-1-14 certified UL60950-1 certified CAN/CSA-C22.2 No. 60950-1-07 certified IEC/EN62368-1 certified IEC/EN60950-1 certified CB report EN55032 compliant EN55024 compliant Selection Guide Part nom. Input Output Output Efficiency max. Capacitive Number Voltage Voltage Current typ. (1) Load (2) [VDC] [VDC] [mA] [%] [µF] R1ZX-0505/P (3) 5 5 200 68 1000 Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resistive load Model Numbering Notes: Note3: standard part is with continuous short circuit protection Note4: without suffix, standard isolation voltage (1kVDC/1 second) with suffix „/H“, high isolation voltage (2kVDC/1 second) Note5: with suffix „-R“, standard packaging tape and reel with suffix „-Tray“ for optional tray packaging Packaging (5) Protection (3) Isolation Voltage (4) Output Power nom. Input Voltage nom. Output Voltage Ordering Examples: R1ZX-0505/P-R 5Vin 5Vout Single Output 1kVDC/ 1 minute isolation with SCP function tape and reel packaging R1ZX-0505/HP-R 5Vin 5Vout Single Output 2kVDC/1 minute isolation with SCP function tape and reel packaging R1ZX-0505/P-Tray 5Vin 5Vout Single Output 1kVDC/ 1 minute isolation with SCP function tray packaging R1ZX-0505/HP-Tray 5Vin 5Vout Single Output 2kVDC/1 minute isolation with SCP function tray packaging
www.recom-power.com REV.: 0/2019 ECO-2 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) R1ZX Series BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter capacitor Input Voltage Range nom. Vin = 5VDC ±5.0% Input Current 300mA Quiescent Current nom. Vin = 5VDC 20mA Minimum Load 0% Internal Operating Frequency 20kHz Output Ripple and Noise (6) 20MHz BW 30mVp-p 100mVp-p Efficiency vs. Load 0 10 20 30 40 50 60 70 80 90 100 100 Efficiency [%] Output Load [%] Notes: Note6: Measurements are made with a 0.1µF MLCC across output. (low ESR) REGULATIONS Parameter Condition Value Output Accuracy -0.5 typ. / ±2.0% max. Line Regulation low line to high line, full load ±1.0% max. Load Regulation 0% to 100% load 0.5 typ. / 1.0% max. 2.0 1.0 -1.0 1.5 0.5 -0.5 -1.5 -2.0 Deviation [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] Deviation vs. Load
www.recom-power.com REV.: 0/2019 ECO-3 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) R1ZX Series PROTECTIONS Parameter Type Value Short Circuit Protection (SCP) below 100mW continuous, automatic recovery Isolation Voltage I/P to O/P standard tested for 1 second rated for 1 minute (7) 1kVDC 500VAC with suffix “/H” tested for 1 second rated for 1 minute (7) 2kVDC 1kVAC Isolation Resistance 10GW min. Isolation Capacitance 100pF max. Leakage Current standard with suffix “/H” 1µA max. 2µA max. Insulation Grade functional Notes: Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note8: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type ENVIRONMENTAL Parameter Condition Value Operating Temperature Range full load @ natural convection 0.1m/s (see graph) -40°C to +65°C Operating Altitude 5000m Operating Humidity non-condensing 5% - 95% RH max. Pollution Degree PD2 Vibration according to MIL-STD-202G MTBF according to MIL-HDBK-217F, G.B. +25°C +65°C 14400 x 10³ hours 3700 x 10³ hours Derating Graph (@ Chamber and natural convection 0.1m/s) -40 -20 0 20 40 7060-30 -10 10 30 50 80 90 110100 100 Output Load [%] Ambient Temperature [°C]
www.recom-power.com REV.: 0/2019 ECO-4 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) R1ZX Series SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Audio/video, information and communication technology equipment - Safety requirements E224736 UL62368-1, 2nd Edition, 2014 CAN/CSA -C22.2 No. 62368-1-14, 2nd Edition Information Technology Equipment, General Requirements for Safety UL60950-1, 2nd Edition, 2014 CAN/CSA C-22.2 No. 60950-1-07, 2nd Edition Audio/video, information and communication technology equipment - Safety requirements (CB Scheme) E224736-4788277362-1 IEC62368-1:2014, 2nd Edition Audio/video, information and communication technology equipment - Safety requirements EN62368-1:2014 + A11:2017 Information Technology Equipment, General Requirements for Safety (CB Scheme) E224736-4788277362-2 IEC60950-1:2005, 2nd Edition + A2:2013 Information Technology Equipment, General Requirements for Safety EN60950-1:2006 + A2:2013 RoHS2+ RoHS 2011/65/EU + AM2015/863 EMC Compliance Condition Standard / Criterion Electromagnetic Compatibility of Multimedia Equipment - Emission Requirements with external filter (see filter suggestion) EN55032:2015 + AC:2016, Class B Information technology equipment - Immunity characteristics - Limits and methods of measurement EN55024:2010 + A1:2015 ESD Electrostatic discharge immunity test Air: ±6kV; Contact: ±4kV EN61000-4-2:2009, Criteria A Fast Transient and Burst Immunity ±0.5kV EN61000-4-4:2012, Criteria A Surge Immunity ±1.0kV EN61000-4-5:2017, Criteria A EMC Filtering Suggestions for EN55032 Class B -Vout +Vout -Vin +Vin +Vout+Vin -Vout-Vin Component List C1 C2 L1 10µF MLCC 470pF/3kVDC 10µH SMD Inductor DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Material base PCB black plastic (UL94V-0) FR4 (UL94V-0) Dimension (LxWxH) 15.24 x 11.10 x 8.5mm Weight 1.6g typ. continued on next page
www.recom-power.com REV.: 0/2019 ECO-5 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) R1ZX Series Dimension Drawing (mm) Recommended Footprint Details Pin Connection Pin # Single 1 -Vin 2 +Vin 4,5 -Vout 7 +Vout 10 NC CG= center of gravity NC= no connection Tolerance: xx.x= ±0.5mm xx.xx= ±0.25mm Pin dimension: ±0.1mm Bottom View Top View 1 2 4 710 710 1 2 4 5 11.10 15.24 4x2.54= 10.16 10.7 12.07 8.0 0.25 8.5 max. 2.54 1.27 2.54 0.50 0.802.50 CG PACKAGING INFORMATION Packaging Dimension (LxWxH) tape and reel (carton) reel 355.0 x 340.0 x 35.0mm 330.2 x 330.2 x 30.0mm tray 260.0 x 205.0 x 27.0mm Packaging Quantity tape and reel 250pcs tray 30pcs Tape Width 24.0mm Storage Temperature Range -55°C to +125°C Storage Humidity 5% - 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.