SFH4730_12 OSRAM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 8

Technical content

Features

 Active chip area 2.1 x 5.4 mm2  max. DC-current 1 A  Low thermal resistance (2.8 K/W)  Spectral emission at 850 nm  ESD safe up to 2 kV acc. to JESD22-A114-E  Eye safety precautions given in IEC 60825-1 and IEC 62471 have to be followed.

Applications

 Infrared Illumination for cameras  Surveillance systems  IR Data Transmission  Driver assistance systems

SFH 4730, SFH 4740 Grenzwerte Maximum Ratings Bezeichnung Parameter Symbol Symbol Wert Value Einheit Unit Betriebs- und Lagertemperatur Operating and storage temperature range TB, op , TB, stg – 40 … + 125 °C Sperrschichttemperatur Junction temperature TJ + 145 °C Sperrspannung Reverse voltage VR 0.5 V Vorwärtsgleichstrom, TB 1) ≤ 90 °C Forward current IF 1 A Stoßstrom, tp < 3 ms, D = 0 Surge current IFSM 5 A Leistungsaufnahme, TB ≤ 90 °C Power consumption Ptot 19 W Thermische Verlustleistung, TB ≤ 90 °C Thermal power-dissipation Pth 15.4 W Wärmewiderstand Sperrschicht / Bodenplatte Thermal resistance Junction / Base plate RthJB 2.8 K/W 1) TB = Temperatur auf der Rückseite der Metallkernplatine / Temperature at the backside of the base plate.

SFH 4730, SFH 4740 2010-12-15 3 Kennwerte (TB = 25 °C) Characteristics Bezeichnung Parameter Symbol Symbol Wert Value Einheit Unit Wellenlänge der Strahlung Wavelength at peak emission IF = 1 A, tp = 10 ms λpeak 860 nm Schwerpunkts-Wellenlänge der Strahlung Centroid wavelength IF = 1 A, tp = 10 ms λcentroid 850 nm Spektrale Bandbreite bei 50% von Imax Spectral bandwidth at 50% of Imax IF = 1 A, tp = 10 ms Δλ 30 nm Abstrahlwinkel Half angle ϕ ± 60 Grad deg. Abmessungen der aktiven Chipfläche1) Dimension of the active chip area L × B L × W 2.1 × 5.4 mm² Schaltzeiten, Ie von 10% auf 90% und von 90% auf 10%, IF = 5 A, RL = 50 Ω Switching times, Ιe from 10% to 90% and from 90% to 10%, IF = 5 A, RL = 50 Ω tr, tf 10, 10 ns Durchlassspannung Forward voltage IF = 1 A, tp = 100 µs VF 15.5 (≤ 19) V Gesamtstrahlungsfluss Total radiant flux IF = 1 A, tp = 100 μs SFH 4730 SFH 4740 Φe Φe 3.6 4.3 W W Temperaturkoeffizient von Ie bzw. Φe Temperature coefficient of Ie or Φe IF = 1 A, tp = 10 ms TCI – 0.3 %/K Temperaturkoeffizient von VF Temperature coefficient of VF IF = 1 A, tp = 10 ms TCV – 10 mV/K Temperaturkoeffizient von λ Temperature coefficient of λ IF = 1 A, tp = 10 ms TCλ,centroid + 0.3 nm/K 1) Die aktive Chipfläche besteht aus 10 einzelnen Chips mit je 1 x 1 mm². The active chip area consists of 10 single chips with 1 x 1 mm² each.

SFH 4730, SFH 4740 Strahlstärke1) Ιe Radiant Intensity1) Ιe 1) Nur eine Gruppe in einer Verpackungseinheit (Streuung kleiner 1.6:1) Only one group in one packing unit (variation lower 1.6:1) Bezeichnung Parameter Symbol Werte Values Einheit Unit SFH 4730 -EB SFH 4730 -FA SFH 4740 -FA SFH 4740 -FB Strahlstärke Radiant Intensity IF = 1 A, tp = 20 ms Ιe min Ιe max 800 1250 1000 1600 1000 1600 1250 2000 mW/sr mW/sr Abstrahlcharakteristik Radiation Characteristics I rel = f (ϕ) 0.2 0.4 1.0 0.8 0.6 ϕ 1.0 0.8 0.6 0.4 50˚ 60˚ 70˚ 80˚ 90˚ 100˚

SFH 4730, SFH 4740 2010-12-15 5 Relative spektrale Emission Relative Spectral Emission Irel = f (λ), TB = 25 °C Max. zulässiger Durchlassstrom Max. Permissible Forward Current IF = f (TB), RthJB = 2.8 K/W 700 nm OHF04132 100 950750 800 850 Irel λ 14010080604020 ˚C0 TB 100 200 400 300 500 700 600 800 FI 900 mA 1100 OHF04318 Durchlassstrom Forward Current IF = f (VF), TB = 25 °C, Single pulse, tp = 100 μs Zulässige Impulsbelastbarkeit Permissible Pulse Handling Capability IF = f (tp), TB = 85 °C, Duty cycle D = parameter OHF04319 FI V A FV 10-1 100 101 10-2 15 20 25 1010 0 -2-3-4-5 1010 10 FI A Pt =D T 210-1 10 tp 10 s 10 OHF04317 T tP IF 0.5 0.33 0.1 0.2 0.05 0.005 0.01 0.02 D = 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.5 Relativer Gesamtstrahlungsfluss Relative Total Radiant Flux Φe/Φe(1A) = f (IF), TB = 25 °C, Single pulse, tp = 100 μs OHF03848 10-3 A 101 010 10-1 IF 10 10 010 11055-2 -1 Φ (1 A) Φe e

SFH 4730, SFH 4740 SMD NTC Thermistor mit Nickel Barrier Termination, Typ 0603 SMD NTC Thermistor with Nickel Barrier Termination, Type 0603 No. of R/T characteristics R25 [Ω] B25/50 [K] B25/85 [K] B25/100 [K] EPCOS 8502 / A01 10k ± 5% 3940 3980 4000 -60 ˚C T R Ω OHL02893 NTC -20 20 60 100 160 210 103 410 610 Typische Thermistor Kennlinie Typical Thermistor Graph (www.epcos.com)

SFH 4730, SFH 4740 2010-12-15 7 Maßzeichnung und Ersatzschaltbild Package Outlines and equivalent circuit diagram Maße in mm (inch) / Dimensions in mm (inch). Verwendeter Stecker / Used male connector on board: ERNI male connector SMD 214012, 4-pins (www.erni.com) Empfohlene Gegenstecker / Recommended female connector for power supply: ERNI female connector SMD 214025, 4-pins (www.erni.com) Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved. The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserv ed. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of tr ansport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or system s must be expressly authorized for such purpose! Critical components 1 , may only be used in life-support devices or systems 2 with the express written approval of OSRAM OS. 1 A critical component is a component usedin a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system. 2 Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.

720-SFH4730 - Osram Opto Semiconductor SFH 4730 720-SFH4740 - Osram Opto Semiconductor SFH 4740