Features

  • Barometric pressure, humidity, and temperature measurement in one transmitter
  • RS-232C serial interface with NMEA protocol for GPS use
  • Graphical display and keypad for convenient operation
  • Analog outputs, RS-232/485
  • Modbus RTU protocol support
  • Traceable to international standards Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300 is a unique instrument measuring three parameters simultaneously. Options
  • Available with up to two barometric pressure sensors for added reliability
  • Optional universal power supply module
  • HMT330MIK installation kit for outdoor use You can choose from the following probe options: PTU301 for wall mounting for example in laboratories or engine rooms, PTU303 for general use, PTU307 warmed probe for outdoor and demanding meteorology applications, and PTU30T for pressure and temperature measurement only. Proven Vaisala sensor technology PTU300 incorporates sensors known for their high accuracy and excellent long- term stability: Vaisala BAROCAPâ for pressure measurement and Vaisala HUMICAPâ for humidity measurement. The temperature sensor is a platinum RTD sensor. Graphical display of measurement data and trends for convenient operation PTU300 features a large numerical and graphical display with a multilingual menu and keypad. It allows users to easily monitor operational data, measurement trends, and access measurement history for the past 12 months. The optional data logger, with real-time clock, makes it possible to generate over four years of measurement history and zoom in on any desired time or time frame. The display alarm allows any measured parameter to be tracked, with freely configurable low and high limits. Versatile outputs and data collection PTU300 comes with a standard RS-232 serial interface. The output format is compatible with major GPS receivers and NMEA-coded messages. An isolated RS-485 interface is available as an option. PTU300 is also capable of applying the Modbus communication protocol, providing Modbus RTU (RS-485) communication. The data logger records data that can be viewed on the local display or transferred to a PC with Microsoftâ Windowsâ software. A USB service cable makes it easy to connect PTU300 to a PC via the service port. Outdoor installation kit Outdoor installation is possible using the optional HMT330MIK installation kit, for applications requiring reliable measurements for meteorological purposes. Flexible calibration Quick, one-point field calibration for humidity is easy using Vaisala Hand-Held Humidity Meter HM70. With Vaisala Barometric Pressure Transfer Standard PTB330TS, including optional humidity and temperature probe, field check and calibration can be performed for all three parameters.

Applications

  • Environmental monitoring in calibration laboratories
  • Industrial applications in semiconductor industry, engine testing and maritime sector
  • GPS meteorology: estimating precipitable water vapor in the atmosphere, weather stations The display also shows the WMO pressure trend ΔP 3h and tendency of 0 … 8. Model Dimensions in mm PTU301 for wall mounting 12 (0.47) 120 (4.72) 169 (6.65) Ø 7 (0.2 183 (7.20) 116 (4.57) 96 (3.78)

PTU303 probe for outdoor use M9x1 37.5 (1.48) 78.5 (3.09) 98.5 (3.88) Ø 12 (0.47) PTU307 warmed probe for demanding meteorological installations M9x1 37.5 (1.48) 79.5 (3.13) 99.5 (3.92) Ø 12 (0.47) Ø 3.2 (0.13) Ø 6 (0.24) 130 (5.12) PTU30T for pressure and temperature only measurement Ø 3.2 (0.13) Ø 6 (0.24) 130 (5.12) HMT330MIK Meteorological Installation Kit enables PTU307 to be installed outdoors to obtain reliable measurements for meteorological purposes.

Pressure range 500 … 1100 hPa 50 … 1100 hPa Accuracy 500 … 1100 hPa 500 … 1100 hPa 50 … 1100 hPa Class A Class B Linearity ±0.05 hPa ±0.10 hPa ±0.20 hPa Hysteresis ±0.03 hPa ±0.03 hPa ±0.08 hPa Repeatability ±0.03 hPa ±0.03 hPa ±0.08 hPa Calibration unceratinty ±0.07 hPa ±0.15 hPa ±0.20 hPa Accuracy at +20 °C / +68 °F ±0.10 hPa ±0.20 hPa ±0.30 hPa Temperature dependence ±0.1 hPa ±0.1 hPa ±0.3 hPa Total accuracy (-40 … +60 °C / -40 … +140 °F) ±0.15 hPa ±0.25 hPa ±0.45 hPa Long-term stability/year ±0.1 hPa ±0.1 hPa ±0.2 hPa Response time (100 % response): One sensor 2 s 1s 1 s Pressure units hPa, mbar, kPa, Pa, inHg, mmH20, mmHg, torr, psia Relative humidity Measurement range 0 … 100 %RH Accuracy (Including non-linearity, hysteresis, and repeatability): ±(1.0 + 0.008 x reading) %RH ±(1.5 + 0.015 x reading) %RH Factory calibration uncertainty (+20 °C / +68 °F) (Defined as ±2 standard deviation limits. Small variations possible, see also calibration certificate.) Sensor for typical applications Vaisala HUMICAP 180 or 180R Sensor for applications with chemical purge/warmed probe Vaisala HUMICAP 180C or 180RC Response Time (90 %) at +20 °C (+68 °F) in Still Air: With grid filter With grid + steel netting filter With sintered filter 8 s / 17 s 1) 20 s / 50 s 1) 40 s / 60 s 1) Temperature Measurement range, housing (barometric pressure measurement limit) 2) Measurement range, probes (operational limit when measuring RH or T) PTU307: -40 … +180 °C (-40 … +356 °F) PTU30T: -70 … +180 °C (-94 … +356 °F) 3) Accuracy at +20 °C (+68 °F) PTU301, PTU303, PTU307: ±0.2 °C (±0.4 °F) Temperature units °C, °F Temperature sensor Pt100 RTD Class F0.1 IEC 60751 1) With HUMICAP 180R or 180RC sensor 2) Note that the operational temperature limits of the PTU303, PTU307, and PTU30T probes are higher than for the PTU300 transmitter itself. The transmitter's temperature limit is based on the upper temperature limit for barometric pressure measurement, +60 °C (+140 °F) 3) PTU30T is used for T and P measurements only, RH measurement not in use. ∆ °C -0.7 0.7 0.6 0.5 0.4 0.3 0.2 0.1 -0.1 -0.2 -0.3 -0.4 -0.5 -0.6 0-60 -40 -20 20 40 60 80 100 120 140 160 180-80 Accuracy over temperature range Operating environment Operating temperature -40 … +60 °C (-40 … +140 °F) Operating temperature with optional display Humidity range Non-condensing Measurement environment For air, nitrogen, hydrogen, argon, helium, and oxygen 1) 1) Consult Vaisala if other chemicals are present. Consider safety regulations with flammable gases. Compliance Compliance marks CE, RCM EMC compliance EN61326-1, Industrial Environment Note: For transmitter with display, a test impedance of 40 Ω is used in IEC61000-4-5 (Surge immunity). Mechanical specifications Cable bushing M20 x 1.5 for cable diameter 8 … 11 mm / 0.31 … 0.43" Conduit fitting 1/2" NPT User cable connector (optional) Option 1 Option 2 M12 series 8-pin (male) Female plug with 5 m (16.4 ft) black cable Female plug with screw terminals Cable diameter, PTU303 6.0 mm Cable diameter, other probes 5.5 mm Standard probe cable lengths 2 m, 5 m or 10 m 1) Housing material G-AlSi 10 Mg (DIN 1725) IP rating IP66 IP65 with local display Weight (depending on selected probe) 1.0 - 3.0 kg / 2.2 - 6.6 lb 1) Additional cable lengths available, please see order form for details. Optional data logger with real-time clock Logged parameters Max. four with trend/min/max values Logging interval 10 s (fixed) Maximum logging period with maximum temporal resolution 4 years 5 months Logged points 13.7 million points per parameter Battery lifetime Min. 5 years

Material LCD with backlight, graphical trend display of any parameter Menu languages English, Chinese, Finnish, French, German, Japanese, Russian, Spanish, Swedish Inputs and outputs Operating voltage With optional power supply module 10 … 35 V DC, 24 V AC ±20 % 100 … 240 V AC, 50/60 Hz Settling time at power-up (one sensor) Class A: 4 s Class B: 3 s Wire size 0.5 … 2.5 mm2 (AWG 20 … 14) Stranded wires recommended Digital outputs RS-232, RS-485 (optional) Protocols ASCII commands, Modbus RTU Service connection RS-232, USB Relay outputs (optional) 0.5 A, 250 VAC Power consumption at +20 °C (+68 °F) (Uin 24 VDC): RS-232 Max. 28 mA Uout 3 x 0 … 1 V / 0 … 5 V / 0 … 10 V Max. 33 mA Iout 3 x 0 … 20 mA Max. 63 mA Display and backlight +20 mA During chemical purge Max. +110 mA During probe heating +120 mA External Loads Current outputs RL < 500 Ω 0 … 1 V output RL > 2 kΩ 0 … 5 V and 0 … 10 V outputs RL > 10 kΩ Analog outputs (optional) Current output 0 … 20 mA, 4 … 20 mA Voltage output 0 … 1 V, 0 … 5 V, 0 … 10 V Humidity and temperature: Accuracy of analog outputs at +20 °C (+68 °F) ±0.05 °% full scale Temperature dependence of analog outputs ±0.005 %/°C (0.003 %/°F) full scale Pressure: Accuracy of analog outputs at +20 °C (+68 °F) ±0.30 hPa (500 … 1100 hPa) ±0.40 hPa (50 … 1100 hPa) Accuracy of analog outputs at ±0.60 hPa (500 … 1100 hPa) ±0.75 hPa (50 … 1100 hPa) Spare parts and accessories PC software and cable 215005 USB-RJ45 Serial Connection Cable 219685 Connection cable for HM70 211339 Wall mounting plate (plastic) 214829 Pole installation kit with rain shield 215109 DIN rail installation set 211477 Duct installation kit, PTU303/307 210697 Cable gland and AGRO, PTU303/307 HMP247CG Solar radiation shield, PTU303/307 /30T DTR502B Meteorological installation kit HMT330MIK Duct installation kit (T probe) 215003 169 (6.65) 183 (7.20) 116 (4.57) 96 (3.78) Ø 7 (0.28) 71 (2.80) 77 (3.03) Dimensions in mm (inches) Published by Vaisala | B210954EN-J © Vaisala Oyj 2023 All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. Any reproduction, transfer, distribution or storage of information contained in this document is strictly prohibited. All specifications — technical included — are subject to change without notice. www.vaisala.com