PTB330 VAISALA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

Features

  • Vaisala BAROCAP sensor
  • Accurate measurement
  • Excellent long-term stability
  • Added reliability through redundancy
  • Graphical trend display with 1- year history data
  • Height and altitude corrected pressure (QFE, QNH)
  • For aviation, professional meteorology, laboratories, and demanding industrial applications
  • Corrosion-resistant IP65/IP66 housing, suitable for outdoor and marine environment Vaisala BAROCAPâ Digital Barometer PTB330 is designed for a wide range of high- end atmospheric pressure measurements. The pressure measurement of PTB330 is based on the Vaisala silicon capacitive, absolute pressure sensor - the Vaisala BAROCAP sensor. It provides high measurement accuracy and excellent long-term stability. Highly accurate The PTB330 series is highly accurate. Class A barometers for the most demanding applications are fine-tuned and calibrated against a high-precision pressure calibrator. Class B barometers are adjusted and calibrated using an electronic working standard. All PTB330 barometers come with a traceable factory calibration certificate. Reliability through redundancy According to your choice, PTB330 can incorporate 1, 2, or 3 BAROCAP sensors. When 2 or 3 sensors are used, the barometer continuously compares the readings of the pressure sensors against one another and reports if they are within the set internal difference criteria. This unique feature provides redundancy in pressure measurement. Users also get a stable and reliable pressure reading at all times, as well as a pre-indication of when to service or recalibrate the barometer. QNH and QFE PTB330 can be set to compensate for the QNH and QFE pressure used especially in aviation. The QNH represents the pressure reduced to sea level, based on the altitude and temperature of the observation site. The QFE represents the height-corrected pressure of small differences in altitude, for example, the air pressure at the airfield elevation. Graphical display PTB330 features a multilingual, graphical display allowing users to monitor measurement trends. PTB330 updates the graph automatically during measurement and it provides a 1-year measurement history. In addition to instant pressure, PTB330 provides the WMO pressure trend and tendency codes.

Applications

PTB330 can be used successfully for aviation, professional meteorology, and for demanding industrial pressure measurement applications such as accurate laser interferometric measurement and exhaust gas analysis in engine test benches.

Barometric pressure range 500 … 1100 hPA Linearity 1) ±0.05 hPa ±0.10 hPa Hysteresis 1) ±0.03 hPa ±0.03 hPa Repeatability 1) ±0.03 hPa ±0.03 hPa Calibration uncertainty 2) ±0.07 hPa ±0.15 hPa Accuracy at +20 °C (+68 °F) ±0.10 hPa ±0.20 hPa Barometric pressure range 50 … 1100 hPA Linearity 1) – ±0.20 hPa Hysteresis 1) – ±0.08 hPa Repeatability 1) – ±0.08 hPa Calibration uncertainty 2) – ±0.15 hPa Accuracy at +20 °C (+68 °F) – ±0.20 hPa Temperature dependence 4) 500 … 1100 hPa ±0.1 hPa ±0.1 hPa 50 … 1100 hPa ±0.3 hPa ±0.3 hPa Total accuracy −40 … +60 °C (−40 … +140 °F) 500 … 1100 hPa ±0.15 hPa ±0.25 hPa 50 … 1100 hPa – ±0.45 hPa Long-term stability 500 … 1100 hPa ±0.1 hPa/year ±0.1 hPa/year 50 … 1100 hPa ±0.2 hPa/year ±0.2 hPa/year Miscellaneous Pressure units hPa, mbar, kPa, Pa inHg, mmH20, mmHg, torr, psia hPa, mbar, kPa, Pa inHg, mmH20, mmHg, torr, psia Resolution 0.01 hPa 0.1 hPa Settling time at startup (1 sensor) 4 s 3 s Response time (1 sensor) 2 s 1 s Acceleration sensitivity – Negligible Maximum pressure limit – 5000 hPa absolute Maximum measurement rate – 10 Hz 1) Defined as ±2 standard deviation limits of endpoint non-linearity, hysteresis, or repeatability error. 2) Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to international standards. 3) Defined as the root sum of the squares (RSS) of endpoint non-linearity, hysteresis error, repeatability error, and calibration uncertainty at room temperature. 4) Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range. 5) For class A you need a longer averaging time or measurement interval. Operating environment Pressure range 500 … 1100 hPa, 50 … 1100 hPa Operating temperature −40 … +60 °C (−40 … +140 °F) Operating temperature with local display IP rating IP66 IP65 (NEMA4) with local display 1) 1) IP rating of PTB330AWS is IP40. Mechanical specifications Pressure fitting Barbed fitting for 1/8-inch (inside diameter) tubing or quick connector with shutoff valve for 1/8‑ inch hose Pressure connector M5 (10‑ 32) internal thread Housing material G AlSi10 Mg (DIN 1725) Weight 1 … 1.5 kg (2.2 … 3.3 lb) Inputs and outputs Supply voltage 10 … 35 V DC Supply voltage sensitivity Negligible Typical power consumption at +20 °C (+68 °F) (voltage at 24 V DC with 1 pressure sensor) RS‑ 232: 25 mA RS‑ 485: 40 mA Output voltage Uout: 25 mA Output current Iout: 40 mA Display and backlight: +20 mA Serial communication RS-232, RS‑ 485, RS‑ 422 Analog output (optional) Current output 0 … 20 mA, 4 … 20 mA Voltage output 0 … 1 V, 0 … 5 V, 0 … 10 V Accuracy at pressure range 500 … 1100 hPa 50 … 1100 hPa At +20 °C (+68 °F) ±0.30 hPa ±0.40 hPa At −40 … +60 °C (−40 … 140 °F) ±0.60 hPa ±0.75 hPa Data transfer software MI70 Link Interface software requirements Microsoftâ Windows OS Microsoftâ Excel

Temperature-compensated analog output module AOUT-1T Isolated RS-485 module RS485-1 Power supply module POWER-1 AC adapters for devices already equipped with an external AC adapter connector AC adapter, EU MI70EUROADAPTER AC adapter, USA MI70USADAPTER AC adapter, UK MI70UKADAPTER AC adapter, AUS MI70AUSDAPTER Static pressure head Static pressure head SPH10 Static pressure head with heating SPH20 Barometer mounting accessories Junction box ASM211113 Wall mounting kit 214829 Installation kit for pole or pipeline 215108 Outdoor installation kit (weather shield) 215109 DIN rail clips with installation plate 215094 Panel mounting frame 216038 Connection cables Connection cable for PTB330 and MI70 handheld meters for spot check or calibration and adjustment 211339 Service cables USB-RJ45 serial connection cable 219685 D9-RJ45 serial connection cable 215005 Output cables for 8-pin connector Connection cable 5 m with 8-pin M12 female, black 212142 Female connector 8-pin M12 with screw terminals 212416 Cable bushings PTB330/220/PTU200 DC adapter and RS-232 cable for PC 213019 PTB330/PTB220/PTU200 DC adapter cable 213026 Others Dust filter 237018SP Barbed pressure fitting 1/8-inch 19498SP Quick connector 1/8‑ inch 220186 Compliance Property Value EU directives and regulations RoHS Directive (2011/65/EU) amended by 2015/863 EMC Directive (2014/30/EU) Low Voltage Directive (2014/35/EU), applies to units equipped with single- phase AC power supply Power-1 Electrical safety EN 61010-1:2010 + A1:2019, applies to units equipped with single-phase AC power supply Power-1 Electromagnetic compatibility (EMC) EN 61326‑ 1, industrial environment EN 55011:2009 + A1:2010 Environmental EN IEC 63000:2018 183 [7.20] 119 [4.69] 143 [5.63] 77 [3.03] mm [in] PTB330 dimensions 145 [5.71] 120 [4.72] mm [in] 141 [5.55] 75 [2.95] PTB330AWS dimensions Published by Vaisala | B210708EN-J © Vaisala Oyj 2023 All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. Any reproduction, transfer, distribution or storage of information contained in this document is strictly prohibited. All specifications — technical included — are subject to change without notice. www.vaisala.com