PSQ60 WALL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 PSD60 Series

60 Watt

FEATURES

  • 2 Year Warranty
  • LED Indicator for Power On
  • 100% Full Load Burn-In Tested
  • Cooling by Free Air Convection
  • Universal AC Input / Full Range
  • Fixed Switching Frequency at 35KHz
  • Built-In EMI Filter, Low Ripple and Noise
  • Soft-Start Circuit, Limiting AC Surge Current
  • Short Circuit, Overload, and Over Voltage Protected SPECIFICATIONS: PSQ60 Series All specifications are based on 25 o C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. INPUT SPECIFICATIONS Input Voltage Range 85 ~ 264VAC (120 ~ 370VDC) Input Frequency 47 to 63Hz AC Current (typical) 2A @ 115VAC 0.8A @ 230VAC Inrush Current (typical) Cold Start 15A @ 115VAC 30A @ 230VAC Leakage Current < 1mA @ 240VAC OUTPUT SPECIFICATIONS Output Voltage See Table Output Power See Table Voltage Tolerance (See Note 3) Voltage Adjustment Range CH.1: 4.75 ~ 5.5V Line Regulation (See Note 4) Load Regulation (See Note 5) Output Current See Table Ripple & Noise (max) (See Note 2) See Table Setup, Rise Time 800ms, 20ms @ 230VAC 1600ms, 20ms @ 115VAC and full load Hold Up Time (typical) 70ms @ 230VAC 15ms @ 115VAC and full load Temperature Coefficient ±0.03%/°C (0 ~ 50°C) on +5V output PROTECTION Overload Protection 105 ~ 150%/115VAC rated output power Protection Type: Hiccup mode, recovers automatically after fault condition is removed. Over Voltage Protection 5V: 5.75 ~ 6.75VDC Protection Type: Hiccup mode, recovers automatically after fault condition is removed. GENERAL SPECIFICATIONS Efficiency (typical) See Table Switching Frequency 35KHz Withstand Voltage 3000VAC (Input to Output), 1500VAC (Input to FG), 500VAC (Output to FG) Isolation Resistance 100MΩ/500DC (Input to Output, Input to FG, and Output to FG) ENVIRONMENTAL SPECIFICATIONS Working Temperature -10°C to +60°C (refer to output load derating curve) Storage Temperature -20°C to +85°C Working Humidity 20 ~ 90% RH non-condensing Storage Humidity 10 ~ 95% RH Cooling Free air convection Vibration 10 ~ 500Hz, 2G 10min./1 cycle, 60min each along X, Y, Z axes. MTBF 284,800 hours min. @ 25°C (MIL-HDBK-217F) PHYSICAL SPECIFICATIONS Weight 550 grams Dimensions 159(L) x 97(W) x 38(H) mm Warranty 2 years SAFETY & EMC (See Note 7) Safety Standards UL60950-1, Approved EMI Conduction & Radiation Compliance to EN55022 (CISPR22) Class B Harmonic Current Compliance to EN61000-3-2,-3 EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A

Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 PSD60 Series OUTPUT VOLTAGE / CURRENT RATING CHART Model Number Input Voltage Output Voltage Rated Output Current Output Current Range Ripple & Noise Rated Output Power Efficiency CH: 1 5 VDC 5.5A 0.5 ~ 8A 100mVp-p CH: 2 12 VDC 2A 0.1 ~ 3A 120mVp-p CH: 3 -5 VDC 0.5A 0 ~ 1A 100mVp-p PSQ60-B CH. 4 85 ~ 264VAC (120 ~ 370VDC) -12 VDC 0.5A 0 ~ 1A 120mVp-p 60W 70% CH: 1 5 VDC 5.5A 0.5 ~ 8A 100mVp-p CH: 2 15 VDC 1.5A 0.1 ~ 3A 120mVp-p CH: 3 -5 VDC 0.5A 0 ~ 1A 100mVp-p PSQ60-C CH. 4 85 ~ 264VAC (120 ~ 370VDC) -15 VDC 0.5A 0 ~ 1A 120mVp-p 60W 72% CH: 1 5 VDC 4A 0.5 ~ 8A 100mVp-p CH: 2 12 VDC 1A 0.1 ~ 3A 120mVp-p CH: 3 24 VDC 1A 0.1 ~ 1.5A 150mVp-p PSQ60-D CH. 4 85 ~ 264VAC (120 ~ 370VDC) -12 VDC 0.5A 0 ~ 1A 120mVp-p 62W 75% NOTES 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25°C ambient temperature. 2. Ripple & noise are measured at 20MHz bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor. 3. Tolerances include set up tolerance, line regulation, and load regulation. 4. Line Regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load and auxiliary outputs at 60% rated load. 6. Each output provides up to maximum current but total load can not exceed maximum output power. 7. The power supply is considered a component, which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. DERATING CURVE STATIC CHARACTERISTICS

Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 PSD60 Series Terminal Pin No. Assignment Pin No. Assignment

1 AC/L

2 AC/N

4 DC OUTPUT -V1

5 DC OUTPUT -V2

6 DC OUTPUT +V2

7 DC OUTPUT COM

8 DC OUTPUT +V1

Unit: mm