DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

1 Watt

Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 1 of 5 Standard SIP Package 90º Bend SIP Package (-F Suffix) FEATURES

  • Input Voltage Range of 85-305VAC/70-430VDC
  • AC and DC Dual-Use (Input From Same Terminal)
  • Compact Size
  • Low Power Consumption
  • Industrial Grade
  • Over Current and Short Circuit Protection
  • RoHS Compliant
  • High Power Density
  • Standard or 90º Bend SIP Package
  • IEC60950, EN60950, and UL60950 Safety Approvals

DESCRIPTION

The PSLS01 series of AC/DC converters offers 1 watt of output power in a compact SIP package. This series consists of single output models with a wide input voltage range of 85-305VAC/70-430VDC. Each model in this series has high efficiency, low power consumption, over current and short circuit protection, as well as the option for 90º bent pins. This series has IEC60950, EN60950 and UL60950 safety approvals and is RoHS compliant. MODEL SELECTION TABLE Model Number(1) Input Voltage Range Output Voltage Output Current Efficiency Maximum Capacitive Load Output Power Certification PSLS01-15B05SS 85-305VAC (70-430VDC) 5V 200mA 66% 220µF 1W UL/CE/CB PSLS01-15B09SS 9V 111mA 67% 100µF PSLS01-15B12SS 12V 83mA 70% 100µF PSLS01-15B15SS 15V 67mA 69% 100µF PSLS01-15B24SS 24V 42mA 68% 100µF SPECIFICATIONS All specifications are based on 25°C, Humidity <75%, Nominal Input Voltage (115V and 230V), and Rated Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Typ Max Unit INPUT SPECIFICATIONS Input Voltage Range AC Input 85 305 VAC DC Input 70 430 VDC Input Frequency 47 63 Hz Input Current 115VAC 0.12 A 277VAC 0.06 Inrush Current 115VAC 9 A 277VAC 15 Recommended External Input Fuse 1A, slow fusing, necessary OUTPUT SPECIFICATIONS Output Voltage See Table Voltage Accuracy 5V Model ±8 % All Others ±5 Line Regulation Full Load ±1.5 % Load Regulation 5%-100% Load ±2.5 % Output Power See Table Output Current See Table Minimum Load 5 % Maximum Capacitive Load See Table Ripple & Noise(2) 20MHz Bandwidth (peak-peak value) 50 120 mV Temperature Coefficient ±0.15 %/ºC Stand-By Power Consumption 5V, 9V, 12V, & 15V Models 0.15 0.25 W 24V Models 0.2 0.3 Hold-Up Time 230VAC Input 150 180 ms PROTECTION Short Circuit Protection Continuous, Self-Recovery Over Current Protection Self-Recovery 110 500 %Io ENVIRONMENTAL SPECIFICATIONS Operating Temperature -40 +85 ºC Storage Temperature -40 +105 ºC Storage Humidity 85 %RH MTBF MIL-HDBK-217F@25ºC 200,000 Hours

Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 2 of 5 SPECIFICATIONS All specifications are based on 25°C, Humidity <75%, Nominal Input Voltage, and Rated Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Typ Max Unit GENERAL SPECIFICATIONS Efficiency 230VAC, %Typ. See Table Switching Frequency 100 kHz Isolation Voltage Input to Output, Test Time: 1 min 3000 VAC PHYSICAL SPECIFICATIONS Weight 0.21oz (6g) Typ. Dimensions (L x W x H) Standard 1.38in x 0.66in x 0.43in (35mm x 16.45mm x 11mm) 90º Bend Pin Package 1.38in x 0.71in x 0.43in (35mm x 18mm x 0.11mm) Cooling Free Air Convection SAFETY CHARACTERISTICS Safety Standards & Certification IEC60950, EN60950, UL60950 Safety Class Class II EMI CE CISPR32/EN55032 CIRSP32/EN55032 Class A(3) Class B(4) RE CISPR32/EN55032 CISPR32/EN55032 Class A(3) Class B(4 ESD IEC/EN61000-4-2 ±4kV Pref. Criteria B RS IEC/EN61000-4-3 10V/m(4) Perf. Criteria A EFT IEC/EN61000-4-4 IEC/EN61000-4-4 ±2kV(3) ±4kV(4) Perf. Criteria B Perf. Criteria B Surge IEC/EN61000-4-5 Line to Line ±1kV(3) Perf. Criteria B IEC/EN61000-4-5 Line to Line ±1kV/line to ground ±2kV(4) Perf. Criteria B CS IEC/EN61000-4-6 10Vr.m.s(4) Perf. Criteria A Voltage Dips, Short Interruption, and Voltage Variations Immunity IEC/EN61000-4-11 0%-70%(4) Perf. Criteria B NOTES 2. Ripple and noise are measured by “parallel cable” method. 3. See Fig. 1 for recommended circuit. 4. See Fig. 2 for recommended circuit. 5. External electrolytic capacitors are required to modules, for more info refer to typical applications 6. In order to increase conversion efficiency of the product with light load in the design, product will have audio noise when it is operating, but will not affect the product’s reliability and performance 7. Module required dispensing fixed after assembled. 8. This part is open frame, at least 6.4mm safety distance between primary and secondary external components of module is needed to meet safety requirements. 9. Product customization is available. *Due to advances in technology, specifications subject to change without notice. CHARACTERISTIC CURVES Temperature Derating Graph Input Voltage Derating Graph Note: This product is suitable for use in natural air cooling envirionments. If in a closed environment, please contact factory.

Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 3 of 5 EFFICIENCY CURVES Efficiency Vs. Input Voltage (Full Load) Efficiency vs. Output Load (Vin=230VAC) MECHANICAL DRAWINGS Note: 2.54*2.54mm PIN OUT Pin Function

1 AC (N)

3 AC (L)

5 +V (cap) 7 -V (cap) 10 -Vo 12 +Vo 1. It is necessary to add C1 between pin5 and pin7 2. It is necessary to add pi-type filter circuit to the output, such as the typical application of Fig. 1 3. It is necessary to have a distance of ≥6.4mm between external components in primary circuit and secondary circuit. Note: Unit: mm[in] Pin section tolerances: ±0.10 [±0.004] General Tolerances: ±0.50 [±0.020] The layout of the device is for reference only, please refer to actual product

Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 4 of 5 90º Bend SIP Package (“-F” Suffix) Note: Grid 2.54*2.54mm PIN OUT Pin Function 5 +V (cap) 7 -V (cap) 10 -Vo 12 +Vo 1. It is necessary to add C1 between pin5 and pin7 2. It is necessary to add pi-type filter circuit to the output, such as the typical application of Fig. 1 Note: Unit: mm [inch] Pin section tolerances: ±0.10 [±0.004] General tolerances: ±0.50 [±0.020] The layout of this device is for reference only, please refer to actual product. DESIGN REFERENCE 1. Typical Application Circuit Model FUSE (Necessary) (Necessary) L2 NTC C2 (Necessary) L1 (Necessary) (Necessary) C4 CY0 TVS PSLS01-15B05SS(-F) 1A/300V 4.7µF/450V 1mH 15D-5 100µF/16V (Solid Capacitor) 2.2µH 68µF/35V 0.1µF/50V 1nF/400VAC SMBJ7.0A PSLS01-15B09SS(-F) 150µF/35V SMBJ12A PSLS01-15B12SS(-F) 100µF/35V SMBJ20A PSLS01-15B15SS(-F) SMBJ20A PSLS01-15B24SS(-F) SMBJ30A Note: 1. C1: AC Input, C1 is input flier capacitor (which is required); DC Input is a filtering capacitor in EMC filter (which is required); C2 and C3 are output flier capacitors (which is required). C2, C3, and L1 form a pi-type filter circuit, they are recommended to be high frequency and low impedance electrolytic capacitors. Capacitance and rated ripple current of capacitors refer to the datasheets provided by the manufacturers. Capacitor voltage reduced to at least 80%. C4 is a ceramic capacitor, which is used to filter high frequency noise. Current of L1 and L2 refer to the datasheets provided by the manufacturers, current derating to at least 80%. TVS is a recommended component to protect post-circuits (if converter fails). External Input MOV1 model is recommended to use S14K350.

Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 5 of 5 EMC Solution-Recommended Circuit Components Recommended Parameter MOV2 S14K350 CY1/CY2/CY3 1nF/400VAC CX 0.1µF/275VAC LCM 3.5mH LDM 0.33mH R2/R3 33Ω/3W Fuse (Necessary) 1A/300V, Slow Fusing COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 50 years. Our in- house research and development engineers will provide a solution that exceeds your performance requirements on- time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: (603)778-2300 Toll Free: (888)597-9255 E-mail: sales@wallindustries.com Web: www.wallindustries.com Address: 37 Industrial Drive Exeter, NH 03833