60 Watts

AC/DC Medical Open Frame Power Supplies Single Output 11/10/2015 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 1 of 4

FEATURES

  • Wide Operating Input Voltage of 80~275VAC
  • Single Outputs
  • Over Voltage, Over Load, and Short Circuit Protection
  • Protection Class I
  • Cooling by Free Air Convection
  • High Efficiency up to 90%
  • Output Power Up to 60 Watts
  • Support Risk Management Process
  • Input to Output: 2MOPP
  • High ESD Immunity
  • IEC60601-1 Edition 3.1, ES60601-1:2005(R2012), CSAC22.2 NO.60601-1:14, and EN60601-1:2006/A1:2013 Safety Approvals APPLICATIONS DESCRIPTION
  • Breathing Therapy Devices
  • Blood Pressure Systems
  • Portable Medical Device
  • ECG \` EEG
  • Medical Tablets The PSHBU58 series of AC/DC medical open frame power supplies provide up to 60 watts of continuous output power. This series consists of single output models with a wide operating input voltage range of 80~275VAC and output voltages ranging from 5VDC to 55VDC. Each model is protected against short circuit, over voltage and over load conditions and have IEC60601-1 Edition 3.1, ES60601-1:2005(R2012), CSAC22.2 NO.6060-1-1:14, and EN60601-1:2006/A1:2013 safety approvals. MODEL SELECTION TABLE Model Number Input Voltage Range Setting Voltage Range(1) Output Current Ripple & Noise(6) No Load Consumption Output Power Total Regulation Efficiency(8) Min Load Max Load PSHBU58-102 80~275VAC 5~6VDC 5.50A 6.60A 100mVp-p 0.5W 33W ±5% 80% PSHBU58-103 6~8VDC 5A 6.66A 100mVp-p 0.5W 40W ±5% 82% PSHBU58-104 8~11VDC 4.54A 6.25A 100mVp-p 0.5W 50W ±5% 86% PSHBU58-105 11~13VDC 4.61A 5.45A 100mVp-p 0.5W 60W ±5% 87% PSHBU58-106 13~16VDC 3.75A 4.67A 100mVp-p 0.5W 60W ±5% 87% PSHBU58-107 16~21VDC 2.85A 3.75A 100mVp-p 0.5W 60W ±5% 87% PSHBU58-108 21~27VDC 2.22A 2.85A 100mVp-p 0.5W 60W ±3% 88% PSHBU58-109 27~33VDC 1.81A 2.22A 100mVp-p 0.5W 60W ±3% 88% PSHBU58-110 33~40VDC 1.50A 1.81A 100mVp-p 0.5W 60W ±3% 89% PSHBU58-111 40~50VDC 1.20A 1.50A 100mVp-p 0.5W 60W ±3% 90% PSHBU58-112 50~55VDC 1.09A 1.20A 100mVp-p 0.5W 60W ±3% 90%

AC/DC Medical Open Frame Power Supplies Single Output 11/10/2015 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 2 of 4 SPECIFICATIONS All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Typ Max Unit INPUT SPECIFICATIONS Safety Approval Input Voltage Range Safety Approval & Specification in Label 100 240 VAC Input Operate Voltage Range Derate linearly from 100% load at 90VAC to 80% load at 80VAC) 80 275 VAC Input Frequency Sine Wave 47 63 Hz Input Current Low Line Full Load, Vin=100VAC 1.2 A High Line Full Load, Vin=240VAC 0.6 Inrush Current Low Line Full Load, 25ºC, Cool Start, Vin=100VAC 30 A High Line Full Load, 25ºC, Cool Start, Vin=100VAC 60 Safety Ground Leakage Current Vin=240VAC, Fi=60Hz 0.25 mA OUTPUT SPECIFICATIONS Output Voltage See Table Line Regulation(4) Full Load, Vin=100~120VAC or 200~240VAC 1 % Total Regulation PSHBU58-102 – PSHBU58-107 ±5 % PSHBU58-108 – PSHBU58-112 ±3 Output Power 60 W Output Current See Table Ripple & Noise See Table Transient Response Time Full Load, Vin=110VAC 4 ms Start-Up Time Full Load, Vin=100~240VAC 0.25 0.5 S Hold-Up Time(7) Full Load, Vin=100VAC 12 ms Temperature Coefficient All Conditions ±0.04 %/ºC PROTECTION Short Circuit Protection Automatic Recovery Over Load Protection Recovers automatically after fault condition is removed 110 150 % Over Voltage Protection Crowbar Mode 110 275 % ENVIRONMENTAL SPECIFICATIONS Operating Temperature Derate linearly from 100% load at 40ºC to 50% load at 70ºC -10 70 ºC Storage Temperature 10~95% RH -40 85 ºC Operating Humidity Non-Condensing 0 95 % RH Storage Humidity 0 95 % RH Electro Static Discharge Air Discharge, IEC61000-4-2 Contact Discharge, IEC61000-4-2 Operating Altitude All Condition 3000 M Vibration 10~500Hz, 10min./1cycle, 60min. each along X, Y, Z axes 5 G Cooling Free Air Convection Flammability Rating UL94V-1 Surge Voltage Line-Neutral 1 kV Line-PE & Neutral PE 2 MTBF Operating Temperature at 25ºC, Calculated per MIL-HDBK-217F 100k h GENERAL SPECIFICATIONS Efficiency Full Load, Vin=230VAC See Table Insulation Resistance 50 MΩ Dielectric Withstanding Voltage Primary to Secondary, limit current <10mA 4000 VAC Primary to PE, limit current <10mA 1500 PHYSICAL SPECIFICATIONS Weight 4.94oz (140g) Dimensions (L x W x H) 4.00in x 1.50in x 1.04in (101.6mm x 38.1mm x 26.5mm) SAFETY Safety Approvals IEC60601-1 Edition 3.1 ES60601-1: 2005 (R1012) CSAC22.2 NO.60601-1:14 EN60601-1:2006/A1:2013 EMC Emission Compliance to EN55011 (CISPR11), EN60601-1-2 Class B Protection Classes Class I

AC/DC Medical Open Frame Power Supplies Single Output 11/10/2015 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 3 of 4 NOTES (1) Setting voltage range is a factory setting and cannot be adjusted. (2) Output can provide up to peak load when the power supply starts up. Continuous staying in more than rated load is not allowed. (3) In 60% rated load condition, each output is checked to be within voltage accuracy. (4) Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. (5) Load regulation is defined by changing ±40% of measured output load from 60% rated load. (6) Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.47µF capacitor at rated load and nominal line. (7) Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated load and nominal line. (8) Efficiency is measured at rated load and nominal line. DERATING CURVES Input Voltage Derating Curve Temperature Derating Curve MECHANICAL DRAWINGS PIN CHART PIN PSHBU58-1XX

1 RTN

2 RTN

3 OUT

4 OUT

Notes: 1. Net Weight: 140g approx. 2. Input Connector mates with Molex housing 09-50-3031/35977-0300 and Moles 2478/35922 series crimp terminal. 3. Output connector mates with Molex housing 09-50-3061/35977-0600 and Molex 2478/35922 series crimp terminal.

AC/DC Medical Open Frame Power Supplies Single Output 11/10/2015 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 4 of 4 COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 50 years. Our in- house research and development engineers will provide a solution that exceeds your performance requirements on- time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: (603)778-2300 Toll Free: (888)597-9255 E-mail: sales@wallindustries.com Web: www.wallindustries.com Address: 37 Industrial Drive Exeter, NH 03833