< Safety control unit < For evaluating safety thru-beam sensors PSE4-SL < Safety category 4 according to EN61496-1 < 24 V DC supply voltage < 2 safe output contacts < Performance level PLe (EN13849-1) is attainable < Component of PSE4 modular system Safety control unit from the PSE4 series Functional Safety Type Approved Dimensions 12022.5 100 Technical Data Limit data Permissible cable length 200 m Functional safety related parameters Performance level (PL) PL e Category Cat. 4 MTTFd 166 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 99 % Indicators/operating means Operation indicator LED green: Power on Release date: 2020-10--

06 Date of

Release date: 2020-10-06 Date of issue: 2020-10-06 Filename: 233900_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Function indicator LED green Electrical specifications Operating voltage UB 24 V DC +20/-10 % Power consumption P0 < 4 W Output Signal output relay, 2 NO Switching voltage max. 250 V AC/DC Switching current max. 4 A Switching power 1000 VA Response time 32 ms Conformity Functional safety ISO 13849-1 Product standard EN 12978 ; ISO 13856-2 Approvals and certificates UL approval cULus Listed File no: NRNT.E344450 TÜV approval TÜV Rheinland 968/M 301.00/11 Ambient conditions Pollution degree 2 Mechanical specifications Degree of protection IP20 Material Polyethylene (PE) Mass approx. 200 g Connection Transmitter Receiver Power supply

24 V DC

wh gn bn A1 (+) X1 X2 X3 13 23 14 24 K1 K2 wh gn bn A2 (-) Safety control unit PSE4-SC-01 Release date: 2020-10-06 Date of issue: 2020-10-06 Filename: 233900_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

A B C D 0 5 10 15 20 25 600 500 400 300 200 100 Force path diagram Measurement parameters: T = 23 °C, mounting position B as per EN 1760-2, measuring location C (EN 1760-2), v = 100 mm/s up to A, v = 10 mm/s from A. Force [N] Path in [mm] Force path diagram representing the deformation of the sensor strip under force Deformation under force with control unit PSE4-SC-01 Deformation [mm] Force [N] A Resistance 12.8 80 B 22.0 250 C 23.0 400 D 24.0 600 Point of activation using PSE4-SC-01 Safety control unit PSE4-SC-01 Release date: 2020-10-06 Date of issue: 2020-10-06 Filename: 233900_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Release date: 2020-10-06 Date of issue: 2020-10-06 Filename: 233900_eng.pdf PSE4-SC-01 Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Safety control unit The modular PSE system comprises the following components: PSE4-SL safety thru-beam sensors: The plug electronics are fully encapsulated in the housing to achieve a high level of resistance to environmental influences such as water, dust, and moisture. Degree of protection IP68 is achieved. Rubber profiles PSE4-RUB and PSE4-ROI: The rubber profile is designed as a double-chamber profile. The emitter and receiver are inserted in the round hollow chamber at the top. When the profile is actuated, the optical channel is interrupted and the enable circuits on the control unit open. Whe n actuated near the end, the emitte r and/or receiver dip into the lower chamber. Th is ensures that the beam of light is broken. However, the forces required are high, meaning the end areas are inactive areas in line with EN 1760-2. PSE safety control units: Controller for the emitter/receiver system. PSE4-ALU aluminum rails: The aluminum rails are available in various lengths and can be used as an option. Functional Principle The emitter transmits pulses of infrared light, which are detected by the receiver. When the emitter light is detected, the receiver turns off the emitter via a control input. Th e "luminous flux" stops. The receiver also detects this status and the emitter is then switched on again after a specified time. This coupling produces a dynamic signal that is conveyed, in principle, to a charge pump. The pump's charge state is analyzed in the evaluation. Any errors in the emitter/receiver system affect the optical or electrical signal, which results in the absence of a dynamic signal. Note: Safety edges must be fully installed to comply with the EC-Type Examination Certificate for the PSE4 series. Possible combinations Mounting or replacing the sensors Notes PSE4-ALU-* PSE4-ALU-3009-* PSE4-ROI-* PSE4-RUB-* PSE4-RUB-30EPDM58-* PSE2-SC-* PSE4-SC-* PSE4-SL-* P S E 4 - A L U - * XX- XXX PSE4-ALU-3009-* - - X X X X P S E 4 - R O I - * X- XXX P S E 4 - R U B - * X- XXX PSE4-RUB-30EPDM58-* - X X X X P S E 2 - S C - * XXXXX X P S E 4 - S C - * XXXXX X P S E 4 - S L - * XXXXXXX Mounting 1 kHz 38 kHz +12 V Gnd Transmitter Receiver Signal

Release date: 2020-10-06 Date of issue: 2020-10-06 Filename: 233900_eng.pdf PSE4-SC-01 Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Safety control unit Other suitable accessories can be found at www.pepperl-fuchs.com In its entirety, the PSE4 safety edge system consists of the control interface, sensors, a rubber sensor strip, and an optional aluminum mounting strip. The system can be used within a temperature range of 5 °Ct o5 5 °C. The control interface analyzes the signal from the sensors and is designed to be installed in a switch cabinet. The safety contact of the control interface is released by actuating the safety edge. The system as a whole can be used in applications up to Cat. 4/PL e as defined in EN ISO 13849-1. Sensor strip PSE4-RUB-XX or PSE4-ROI- XX and accompanying aluminum mounting strip Cut PSE4-ALU-XX to the required length. Slide the emitter and receiver into the upper chamber. Guide the emitter cable through the lower chamber to the receiver side. Accessories Function 1 2 3 4 5 6 7