PSE2-SC-02 PF | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
< Safety control unit < For evaluating safety thru-beam sensors PSE4-SL < Safety category 3 according to EN61496-1 < 24 V DC supply voltage < 1 safe output contact < Performance level PLd (EN13849-1) is attainable < Component of PSE4 modular system Safety control unit from the PSE2/PSE4 series Functional Safety Type Approved Dimensions 12022.5 100 Technical Data Limit data Permissible cable length 200 m Functional safety related parameters Performance level (PL) PL d Category Cat. 3 MTTFd 109 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 87 % Indicators/operating means Operation indicator LED green: Power on Release date: 2020-10--
06 Date of
Release date: 2020-10-06 Date of issue: 2020-10-06 Filename: 262534_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091
Function indicator LED green Electrical specifications Operating voltage UB 24 V DC +20/-10 %
24 V AC ± 10 %
Power consumption P0 < 4 W Surge protection overvoltage category III Output Signal output relay, 1 NO Switching voltage 230 V AC / 24 V DC Switching current 3 A AC / 4 A DC Mechanical life > 107 switching cycles Response time 18 ms Output 1 Output type Signal output, PNP, open collector Switching voltage UB - 1 V Switching current max. 50 mA Conformity Functional safety ISO 13849-1 Product standard EN 12978 ; ISO 13856-2 Approvals and certificates UL approval cULus Listed File no: NRNT.E344450 TÜV approval TÜV Rheinland 968/M 301.00/11 Ambient conditions Pollution degree 2 Mechanical specifications Degree of protection IP20 Connection screw terminals , lead cross section 2 x 1 mm2 Material PC / PA black Mass approx. 150 g Safety control unit PSE2-SC-02 Release date: 2020-10-06 Date of issue: 2020-10-06 Filename: 262534_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091
24 V DC
switch machine safety circuit machine safety circuit external bridge or Transmitter Receiver Transmitter Receiver Transmitter Receiver wh gn bn wh gn1 bn A1 (+) X2 X3 13 wh gn bn bn gn2 gn3 gn4 wh gn bn wh gn bn wh gn bn wh gn bn wh gn bn wh gn bn A2 (-) Safety control unit PSE2-SC-02 Release date: 2020-10-06 Date of issue: 2020-10-06 Filename: 262534_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091
Release date: 2020-10-06 Date of issue: 2020-10-06 Filename: 262534_eng.pdf PSE2-SC-02 Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Safety control unit The PSE 2 module is comprised of the following components: Safety thru-beam sensors PSE4-SL: The emitter and receiver housings are fully encapsulated to provide maximum protection against environmental influences such as water, dust and moisture and achieve degree of protection IP 68. Sensor strips PSE4-RUB and PSE4-ROI: The sensor strip has a two chamber design . The emitter and receiver are housed in the round top chamber. When the sensor strip is actuated, the optical channel is interrupted and the safety contacts on the control unit open. When actuation occurs in the end area, the emitter and receiver are pushed into the lower chamber to ensure that the light beam is broken. However, the force required is extremely high and the end areas become inactive as specified in EN 1760-2. Safety control unit PSE2-SC: The signal from the emitter/receiver system is evaluated as specified in EN ISO /IEC 61496-1 according to control category 3. Aluminum rails PSE4-ALU: Aluminum mounting rails are available in different lengths. Operating principle The emitter transmits pulses of infrared light, which are detected by the receiver. When the emitter light is detected, the receiver turns off the emitter via a control input. The "optical emission" stops. The receiver also detects this status and the emitter is then switched on again after a specified time. This coupling generates a dynamic signal sent to a buffer. The evaluation analyzes the charge state of the buffer. Any errors in the emitter/receiver system affect the optical or electrical signal, which results in the absence of a dynamic signal. Note: Only fully fitted safety edges comply with the examination certificate for the PSE2 series. Possible combinations Mounting or replacing the sensors Notes PSE4-ALU-* PSE4-ALU-3009-* PSE4-ROI-* PSE4-RUB-* PSE4-RUB-30EPDM58-* PSE2-SC-* PSE4-SC-* PSE4-SL-* P S E 4 - A L U - * XX- XXX PSE4-ALU-3009-* - - X X X X P S E 4 - R O I - * X- XXX P S E 4 - R U B - * X- XXX PSE4-RUB-30EPDM58-* - X X X X P S E 2 - S C - * XXXXX X P S E 4 - S C - * XXXXX X P S E 4 - S L - * XXXXXXX Mounting 1 kHz 38 kHz +12 V Gnd Transmitter Receiver Signal
Release date: 2020-10-06 Date of issue: 2020-10-06 Filename: 262534_eng.pdf PSE2-SC-02 Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Safety control unit Other suitable accessories can be found at www.pepperl-fuchs.com This control interface works with the PSE4 Series and as a complete system consists of the control unit, sensors, a rubber sensor strip, and an optional aluminum mounting strip. The system has been tested within a temperature range of 5 °Ct o5 5 °C in line with EN 1760-2 and is suitable for finger protection. The control interface analyzes the signal from the sensors and is designed to be installed in a switch cabinet. The safety contact of the control interface is released by actuating the safety edge. With this control interface, the system as a whole meets the requirements for performance level d, cat. 3 in accordance with EN ISO 13849-1. Sensor strip PSE4-RUB-XX or PSE4-ROI- XX and accompanying aluminum mounting strip Cut PSE4-ALU-XX to the required length. Slide the emitter and receiver into the upper chamber. Guide the emitter cable through the lower chamber to the receiver side. Accessories Function 1 2 3 4 5 6 7