PSD60 WALL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 PSD60 Series
60 Watt
FEATURES
- 2 Year Warranty
- LED Indicator for Power On
- 100% Full Load Burn-In Tested
- Cooling by Free Air Convection
- Universal AC Input / Full Range
- Built-In EMI Filter, Low Ripple Noise
- Fixed Switching Frequency at 54KHz
- High Efficiency, Low Working Temperature
- Soft-Start Circuit, Limiting AC Surge Current
- Short Circuit, Overload, and Over Voltage Protected SPECIFICATIONS: PSD60 Series All specifications are based on 25 o C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. INPUT SPECIFICATIONS Input Voltage Range 85 ~ 264VAC (120 ~ 370VDC) Input Frequency 47 to 63Hz AC Current (typical) 2A @ 115VAC 1A @ 230VAC Inrush Current (typical) Cold Start 20A @ 115VAC 40A @ 230VAC Leakage Current < 3.5mA @ 240VAC OUTPUT SPECIFICATIONS Output Voltage See Table Output Power See Table Voltage Tolerance (See Note 3) PSD60-A: CH.1: ±2.0% CH.2: ±6.0% PSD60-B: CH.1: ±2.0% CH.2: ±5.0% Voltage Adjustment Range CH.1: 4.75 ~ 5.5V Line Regulation PSD60-A: CH.1: ±0.5% CH.2: ±1.0% PSD60-B: CH.1: ±0.5% CH.2: ±0.5% Load Regulation (See Note 4) PSD60-A: CH.1: ±0.5% CH.2: ±4.0% PSD60-B: CH.1: ±0.5% CH.2: ±4.0% Output Current See Table Ripple & Noise (max) (See Note 2) See Table Setup, Rise Time 300ms, 50ms @ 230VAC 800ms, 50ms @ 115VAC and full load Hold Up Time (typical) 80ms @ 230VAC 10ms @ 115VAC and full load Temperature Coefficient ±0.03%/°C (0 ~ 50°C) on +5V output PROTECTION Overload Protection 105 ~ 150% rated output power Protection Type: Hiccup mode, recovers automatically after fault condition is removed. Over Voltage Protection 5V: 5.75 ~ 6.75V Protection Type: Hiccup mode, recovers automatically after fault condition is removed. GENERAL SPECIFICATIONS Efficiency (typical) See Table Switching Frequency 54KHz Withstand Voltage 3000VAC (Input to Output), 1500VAC (Input to FG), 500VAC (Output to FG) Isolation Resistance 100MΩ/500DC (Input to Output, Input to FG, and Output to FG) ENVIRONMENTAL SPECIFICATIONS Working Temperature -10°C to +60°C (refer to output load derating curve) Storage Temperature -20°C to +85°C Working Humidity 20 ~ 90% RH non-condensing Storage Humidity 10 ~ 95% RH Cooling Free air convection Vibration 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min each along X, Y, Z axes. MTBF 301,200 hours min. @ 25°C (MIL-HDBK-217F) PHYSICAL SPECIFICATIONS Weight 540 grams Dimensions 159(L) x 97(W) x 38(H) mm Warranty 2 years SAFETY & EMC (See Note 6) Safety Standards UL1012, UL60950, TUV EN60950 Approved EMI Conduction & Radiation Compliance to EN55022 (CISPR22) Class B Harmonic Current Compliance to EN61000-3-2,-3 EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 PSD60 Series OUTPUT VOLTAGE / CURRENT RATING CHART Model Number Input Voltage Output Voltage Rated Output Current Output Current Range Ripple & Noise Rated Output Power Efficiency CH: 1 5 VDC 4A 0.3 ~ 6A 75mVp-p PSD60-A CH: 2 12 VDC 3A 0.2 ~ 4A 150mVp-p 56W 73% CH: 1 5 VDC 3A 0.3 ~ 6A 75mVp-p PSD60-B CH: 2 85 ~ 264VAC (120 ~ 370VDC) 24 VDC 1.8A 0.2 ~ 2.2A 150mVp-p 58W 76% NOTES 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25°C ambient temperature. 2. Ripple & noise are measured at 20MHz bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor. 3. Tolerances include set up tolerance, line regulation, and load regulation. 4. Load regulation is measured from 20% to 100% rated load and other output at 60% rated load. 5. Each output provides up to maximum current but total load can not exceed maximum output power. 6. The power supply is considered a component, which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. DERATING CURVE STATIC CHARACTERISTICS (B)
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 PSD60 Series Terminal Pin No. Assignment Pin No. Assignment
1 AC/L
2 AC/N
4 DC OUTPUT +V2
5 DC OUTPUT +V1
6,7 DC OUTPUT COM Unit: mm