For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Cat. No. PSC-4012 PSC-4015 PSC-4024 PSC-4048 DC VOLTAGE 12V 15V 24V 48V RATED CURRENT 3.4A 2.7A 1.7A 0.85A CURRENT RANGE 0 ~ 3.4A 0 ~ 2.7A 0 ~ 1.7A 0 ~ 0.85A RATED POWER 40.8W 40.5W 40.8W 40.8W RIPPLE & NOISE (max) 100mVp-p 100mVp-p 120mVp-p 180mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE TOLERANCE ±1.0% ±1.0% ±1.0% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION ±1.0% ±1.0% ±1.0% ±1.0% LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% SETUP , RISE TIME < 800ms, < 50ms / 230VAC at full load HOLD UP TIME (Typ.) > 32ms / 230VAC; >16ms / 115VAC at full load VOLTAGE RANGE 88 ~ 264VAC; 124 ~ 370VDC Derating may be needed under low input voltages. Please check the derating curve for more details. FREQUENCY RANGE 47~63Hz EFFICIENCY (Typ.) 84% 84% 84% 85% AC CURRENT (Typ.) 0.8 A / 115VAC; 0.4A / 230VAC INRUSH CURRENT (Typ.) COLD START 30A / 115VAC; 60A / 230VAC LEAKAGE CURRENT < 1mA/ 230VAC OVERLOAD PROTECTION > 105% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. OVERVOLTAGE PROTECTION 115% ~ 150% rated output voltage Protection type: latch-off mode OVER TEMPERATURE PROTECTION Power supply shut down at 70˚C constant current limiting / output voltage goes to 0; re-power on to recover WORKING TEMP . -20 ~ +70˚C (Refer to output load derating curve) WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP . / HUMIDITY -40 ~ +85˚C; 10 ~ 95% RH TEMP . COEFFICIENT ±0.03% / ˚C (0 ~ 50˚C) VIBRATION 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant WITHSTAND VOLTAGE I/P-O/P: 4242DC I/P-FG: 2121DC 1 minute ISOLATION RESISTANCE I/P-O/P , I/P-FG, O/P-FG: 100M Ohms/500VDC EMI CONDUCTION & RADIATION EN55022: 2006 Class B HARMONIC CURRENT EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005 EMS IMMUNITY EN61204-3:2000, EN55024:1998+A1:2001+A2:2003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. DC OK Signal Relay contact (30VDC / 1A, 120VAC / 1A) MTBF 947.2K hrs MIL-HDBK-217K DIMENSION 40x90x99 mm (WxHxD) PACKING 0.28Kg/27 pcs./8.76Kg CONNECTION I/P 3 poles, O/P: 6 poles screw DIN terminal COOLING Free air convection All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. Features:

  • Universal AC input (88-264V AC)
  • Protections: Short Circuit / Overload / Overvoltage
  • Brown-out protection
  • Installed on DIN rail TS35 / 7.5 or 15
  • True DC OK signal output
  • All wiring 105°C long life electrolytic capacitors
  • High operation temperature up to 70°C
  • Withstands 2G vibration test
  • High efficiency, long life and high reliability
  • 3 year warranty
  • UL1310 Class 2 Power unit / LPS pass
  • UL508 (Industrial control equipment) listed PSC-40 Series E361935 E205412 OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY & EMC OUTPUT

Altech Corp.

  • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 Mechanical Specification Block Diagram DC OK Relay Contact N L Ta=25°C 100 110 120 264VAC Load (%) Load V.S I/P Voltage Input Voltage(V AC)60Hz 100 -20 Ambient Temperature (°C) 0 10 20 30 40 50 60 70 100Load (%) Load V.S Temp. II//PP EEMMII FFIILLTTEERR RREECCTTIIFFIIEERRSS FFIILLTTEERR PPOOWWEERR SSWWIITTCCHHIINNGG DDEETTEECCTTIIOONN CCIIRRCCUUIITT ++VV --VV CCOONNTTRROOLL RREECCTTIIFFIIEERRSS FFIILLTTEERR DDCC OO KK Contact Close Contact Ratings (max.) Contact Open When the output voltage reaches the adjusted output voltage When the output voltage drop below 90% rated output voltage 30V / 1A resistive load Unit : mm / inch Derating Curve Pin No. Pin No. 1,2 3,4 Assignment Assignment FG AC/L AC/N DC OUTPUT +V DC OUTPUT -V 5,6 DC OK RELAY CONTACT Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB2) PSC-40 Series Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937.