Altech Corp.® •35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com A ltech U L508 MA10U 15.910U 6.3/7.5/8.7/10 MA16U 15.911U 10/12/14/16 MA20U 15.912U 16/17/18.5/20 MA25U 15.913U 20/21.5/23/25 MA32U 15.914U 25/27/30/32 MA40U 15.915U 32/34/37/40 Note:HEA - Horsepower Equivalent Amperes,the nominal amperage assigned to standard motor horsepower ratings in design guide tables such as HEA values (in parenthesis) by 1.1 if power factor is 90%, and by 1.2 if power factor is 80%. a The standard-circuit short-circuit rating is 14kA for all types. Group ratings can be used in a standard circuit (e.g., MA1.0U at 42kA), but a higher standard rating cannot be used in a group circuit (e.g., MA40U at 14kA only in standard circuit.) FLA Dial Adjustment MarkingsCat. No. Type and Rated Current 3Ø HORSEPO WER RA TINGS AT NOMINAL LINE VOL TAGE (See Note for HEA Definition) 110-120V HP (HEA) 200V HP (HEA) 208V HP (HEA) GR OUP SHOR T CIRCUIT RA TING AT 480VAC a (and BCP size) 42kARMS symmetrical (max.1200A MCCB or RK5) 14kARMS symmetrical (max. 350A MCCB or RK5) 10kARMS symmetrical (max. 350A MCCB or RK5) 220-240V HP (HEA) 460-480V HP (HEA) Through MA2.5U, ampere rated for motor circuits having a full- load-amperage (FLA) not exceeding the MA’s general purpose rated current (RC, equals maximum dial setting) and a locked rotor current not exceeding 6 times the MA’s RC. MA- Series Three Phase Adjustable Trip Miniature Circuit Breakers/ Manual Motor Controllers The MA was designed to handle the high inrush loads of 3 phase transformers, power supplies, motors, etc. The MA protects wiring and equipment from damage caused by the three major classes of over-current, yet greatly reduc- es the number of nuisance trips in high starting and inrush current circuits. An IEC device with excellent ratings under a UL listing at 480Y/277V (including group ratings) and at 500V under international standards, the Altech/ABL Sursum MA provides short and long term cost effective circuit protection for USA and/or export applications. The short term advantages include: (1) adjustable thermal trip allows finalization of initial designs before procurement of the load equipment is complete; (2) snap-on mounting for readily available, internationally standardized DIN Rail saves panel layout design time as well as installation and change labor; (3) large cage-clamp terminals with screws suitable to power screwdrivers, simplifies and speeds wiring; (4) convenient switched disconnect during factory testing and/or initial start-up savestime and aggravation. The key long term advantage is customer satisfaction and proven over-current pro- tection of wiring and equipment (and the lack of rework/repair costs). UL508 listed E137938 CAN/CSA-C22.2 No.14 certified Type Designation (a) (b) (c) (d) (a)= MA - Manual Motor Controller (b)= Rated Current (c)= U -US Housing (d)= Blank - Standard Terminal RT - Ring-tongue Terminal Voltage Rating AIC (Interrupt Capacity) Standard ShortCircuit Withstand Rating (UL/CSA Ratings) Group ShortCircuit Ratings (UL/CSA Ratings) Typical Life Calibration Temperature Standard Pack and Weight Terminal Size Acceptability 480Y/277VAC 0.16A-2.5A:42kA;4.0A-16A:14kA;20A-40A:10kA 0.16A-2.5A:42kA;4.0A-16A:14kA see above 6000 on/off operations with 2xRC 1/450g (1.0 lb.) Top/Bottom: 18-3 AWG
Altech Corp.® •35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com A ltech U L508 0.1 1 1.15 1.5 2 2.3 3 4 5 6 6.9 8 10 12 16 19 0.2 0.4 0.6 120 Multiple of Dial Setting (Thermal) M ultiple of Rated Current (Magnetic Trip) Rated Current = Max. Dial Setting Seconds M inutes Tripping tim e tTripping tim e t M A0.16U-MA16U M A 3 Phase Controller Thermal Overload (B, C, D) “Must Trip” Current = 115% of Dial Setting “Must Not Trip” > 1 hr = 105% ofDialSetting 0.1 11.15 1.5 2 2.3 3 4 5 6 6.9 8 10 12 12.5 0.2 0.4 0.6 120 Multiple of Dial Setting (Thermal) Multiple of Rated Current (Magnetic Trip) Rated Current = Max. Dial Setting Seconds M inutes MA20U-MA40U MA 3 Phase Controller Thermal Overload (B, C, D) “Must Trip” Current = 115% ofDial Setting “Must Not Trip” > 1 hr = 105% ofDial Setting Magnetic Trip Nominal 1100% of Rated Current Magnetic Trip Nominal 1100% of Rated Current DIMENSIONS MA/USA Manual Motor Controller 68mm (2.68 in.) 44mm (1.73 in.) 30.5mm (1.20 in.) 45m m (1.77 in.) 35m m (1.38 in.) 45m m (1.77 in.) 89.5m m (3.52 in.) 7mm (.28 in.) 37.5mm (1.48 in.) 44mm (1.73 in.) 25.5mm (1.0 in.) 6mm (.24 in.) 7mm (.28 in.) 17.5mm (1.28 in.) 3mm (.12 in.) 52.5mm (2.07 in.) MA.16 VDE 0660 AC-3 12A 10A 14A 16A 40°C2 0 °C 500V 50-60Mz ABL SURSUM
Altech Corp.® •35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com A ltech U L508 Lock-out ** Cat.No. EASS Prevent inadvertent resetting of the V-EA or MA during maintenance. Fits 1/4”pad lock. Cooling Spacer Cat.No. 15.960 FA - Shunt Trip UA -Undervoltage Trip H -Auxiliary Switch * Please consult Altech for your 50Hz application needs. ** V-EA and MA can also be locked in the on and off position by simply using a common lead or meter seal, which gets fed through the hole in the handle and a corresponding hole in the housing. Type/ Line Voltage Cat.No. 60Hz* UA120 120VAC UA240 240VAC UA277 277VAC UA415 415VAC UA480 480VAC Std.Pk.:1 Unit Weight: 70 grams (0.16 lb.) Width:17.5mm (.689in.) V-EA and MA Circuit Breaker Accessories Accessories can be factory or field mounted on V-EA and MA manual motor controllers for enhanced control and monitoring capabilities. Field mounting kits include all necessary parts and instructions. Accessories can be gang mounted on a single controller (the Auxiliary Switch in the outside position). The mounting arrangement links the internal latch-pins for the tripping mechanisms, ensuring simul- taneous trips. Handles are linked to simplify manual resetting. Type/ Contact Wire Cat.No. Rating Size Approvals For Use With: H11U 10A / 220V AC 4mm 2 (12 AWG) V-EA, MA 3A / 110V DC or pulsed 1A / 220V DC or pulsed Std. Pk.: 1 Unit W eight:45 grams (0.12 lb.) Width: 9mm (.354in.) UL Trip/Coil Type/ Voltage Max. Coil Cat. No. AC or DC Current Approvals FA12U 12V 1.3A FA24U 24V 0.6A FA48U 48-72V 0.2A FA110U 110V/220V 0.25A/0.5A Std.Pk.: 1 Unit Weight: 120 grams (0.27 lb.) Width: 17.5mm (.689in.) UL UL UL UL UL508 listed E137938