PSB2132 INFINEON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 69

Technical content

SICOFI ®2-TE Two Channel Codec Filter for Terminal Application PSB 2132 Version 2.2 Hardware Reference Manual, DS 1, Feb. 2001 Wired Communications Never stop thinking.

Published by Infineon Technologies AG, St.-Martin-Strasse 53, D-81541 München, Germany © Infineon Technologies AG 2001. All Rights Reserved. Attention please! The information herein is given to describe certain components and shall not be considered as warranted characteristics. Terms of delivery and rights to technical change reserved. We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding circuits, descriptions and charts stated herein. Infineon Technologies is an approved CECC manufacturer. Information For further information on technology, delivery terms and conditions and prices please contact your nearest Infineon Technologies Office in Germany or our Infineon Technologies Representatives worldwide (see address list). Warnings Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered.

SICOFI ®2-TE Two Channel Codec Filter for Terminal Application PSB 2132 Version 2.2 Hardware Reference Manual, DS 1, Feb. 2001 Never stop thinking.

For questions on technology, delivery and prices please contact the Infineon Technologies Offices in Germany or the Infineon Technologies Companies and Representatives worldwide: see our webpage at http://www.infineon.com/ ABM®, AOP®, ARCOFI®, ARCOFI®-BA, ARCOFI®-SP, DigiTape®, EPIC®-1, EPIC®-S, ELIC®, FALC®54, FALC®56, FALC®-E1, FALC®-LH, IDEC®, IOM®, IOM®-1, IOM®-2, IPAT®-2, ISAC ®-P, ISAC ®-S, ISAC ®-S TE, ISAC ®-P TE, ITAC ®, IWE ®, MUSAC ®-A, OCTAT®-P, QUAT ®-S, SICAT ®, SICOFI ®, SICOFI ®-2, SICOFI ®-4, SICOFI ®-4µC, SLICOFI® are registered trademarks of Infineon Technologies AG. ACE™, ASM™, ASP™, POTSWIRE™, QuadFALC™, SCOUT™ are trademarks of Infineon Technologies AG. PSB 2132 Revision History: Current Version 2001-02-20 DS 1 Previous Version: Data Sheet 07.97 DS1 (V 1.1) Delta Sheet 11.98 DS2 (V 1.4) Errata Sheet 05.98 DS1 (V 1.4) Page Subjects (major changes since last revision)

Hardware Reference Manual 2001-02-20

Hardware Reference Manual 2001-02-20

Hardware Reference Manual 2001-02-20

Hardware Reference Manual 2001-02-20 Table 31 Channel-Specific Configuration Register (CR) Map (Read & Write) . . 36

Hardware Reference Manual 1 2001-02-20 Preface This document provides detailed technical information about the SICOFI ®2-TE. It is intended for anyone considering or using the device for system design or board layout for a broad range of analog telephony applications. Organization of this Document This Hardware Reference Manual is organized as follows:  Chapter 1, Overview Includes a general description of the architecture, feature list, and logic symbol.  Chapter 2, Pin Descriptions Illustrates the Pin Configuration and provides detailed functional descriptions.  Chapter 3, Functional Description Provides a block diagram and summarizes the major functional blocks.  Chapter 4, Operational Description Begins with a state diagram and description of the operating states of all two channels and concludes with detailed transmission characteristics.  Chapter 5, Interface Descriptions Describes the Analog, IOM-2 PCM, Signaling, and Serial Microcontroller interfaces.  Chapter 6, Programming Overview Illustrates the register model and coefficient RAM structure, provides a register map and summary, and identifies the programming command sequences.  Chapter 7, Application Hints Describes the development system available for the PSB 2132, and provides guidelines and schematics for board layout.  Chapter 8, Electrical Characteristics and Timing Diagrams Provides detailed tables for the electrical characteristics and includes timing diagrams for the Analog, IOM-2 PCM, Serial Microcontroller, and Signaling interfaces.  Chapter 9, Test Configuration Describes the test loops and cut-offs available for functional tests and diagnostics.  Chapter 10, Package Outlines Illustrates the P-MQFP-64 package in which the PSB 2132 is manufactured.  The Appendix Includes a glossary and an index. Related Documentation Other documentation for the PSB 2132 includes a Product Brief, a Product Overview, a Programmer’s Reference Manual , and assorted Application Notes . Similar documentation is also available for the other members of the SICOFI Codec family including the PSB 2134, PEB 2466, and PEB 2266. Documentation is available by accessing our website: http://www.infineon.com/sicofi

Hardware Reference Manual 2 2001-02-20

1 Overview

The two-channel codec filter PSB 2132 SICOFI®2-TE is built around a central DSP-core which provides independent filter structures for both channels. Its analog I/O pins are used to connect to external subscriber line interface circuits (SLICs). Their signals are internally routed to the analog-to-digital and digital-to-analog converters (ADC, DAC). The signaling pins carry line status and control information to and from the SLICs. Two programmable clock outputs are available, one of which can be used for generating a ringing signal (RGEN). The SICOFI®2-TE’s IOM-2 PCM Interface connects directly to a 768 kbit/s IOM-2 bus, often used in terminal equipment. The digitized voice band signals are available as A-Law or µ-Law codes within selectable 8-bit time slots. The SICOFI®2-TE modes, features, and filter characteristics are programmed through a serial interface to a microcontroller. The access mechanism is very simple, and can be implemented with as few as three I/O ports. Figure 1 SICOFI ®2-TE Architecture SLIC 1 ADC - DAC Signaling SLIC 2 ADC - DAC Signaling Highway A Highway B Status and Control Registers CRAMPLL, Clocking Serial Microcontroller Interface t/r t/r PSB 2132 SICOFI2-TE Digital Filters Channel 1 Digital Filters Channel 2 DSP Core PCM Interface 2132_201

Hardware Reference Manual 3 2001-02-20 Two Channel Codec Filter for Terminal Application SICOFI®2-TE PSB 2132 Version 2.2 CMOS Type Package PSB 2132 Version 2.2 P-MQFP-64

1.1 Features

 Two-channel single chip codec with digital filters  High analog driving capability (300 Ω,5 0p F ) f o r direct driving of transformers  Digital Signal Processing (DSP) technique  Programmable digital filters to adapt transmission behavior, especially for: – AC impedance matching – Transhybrid balancing – Frequency response – Signal levels – A/µ-Law compression and expansion  Fulfills international (e.g. ITU-T Q.552, G.712) and country-specific requirements  High performance ADC and DAC for excellent linearity and dynamic gain  Programmable Analog Interface to electronic SLICs or transformer solutions  Seven SLIC-signaling I/O pins per channel with programmable debouncing  IOM-2 compatible PCM interface (1.536 MHz DCL, 768 kHz Bit Clock)  Easy to use 4-pin Serial Microcontroller Interface (SPI compatible) for read/write access  Single supply voltage (5 V)  Advanced low-power mixed-signal CMOS technology  Two programmable tone generators per channel (DTMF possible)  Level metering function for system tests and for analog input signal testing  Advanced on-chip functions for device and system diagnostics and manufacturing test – Five digital loops – Four analog loops  Support tools include: – Hardware development board — STUT 2466 – QSICOS Coefficient Calculation and Register Configuration Software  Standard P-MQFP-64 package

Hardware Reference Manual 4 2001-02-20

1.2 Logic Symbol

Figure 2 SICOFI ®2-TE Logic Symbol

1.3 Typical Applications

Many applications will benefit from the versatility of the SICOFI ®2-TE codec and filter. The inherent flexibility enables several products to be developed around one basic architecture, thus affording potentially significant savings in time to market, inventory costs, and support administration. The following list represents some of the typical applications for which the SICOFI®2-TE codec was designed: Small PBX, Terminal Adapters, and intelligent NTs. Refer to the Product Overview, Chapter 5 Application Hints for more information. Analog Interface Signaling Interface Channel Channel INT12RESET# VOUT2 Channel Channel VIN2 VOUT1 VIN1 SICOFI2-TE PSB 2132 SI1_0 SI1_1 SO1_0 SO1_1 SB1_0 SB1_1 SB1_2 SI2_0 SI2_1 SO2_0 SO2_1 SB2_0 SB2_1 SB2_2 CHCLK RGEN BCL DU DD DU DCL DD FSC IOM-2 PCM Interface DCLK CS# DIN Micro- controller Interface DOUT 2132_203

Hardware Reference Manual 5 2001-02-20

2 Pin Descriptions

2.1 Pin Diagram

(top view) Figure 3 Pin Configuration of SICOFI ®2-TE 1 2 345 6 78 9 10 11 12 13 14 15 16 SICOFI®2-TE PSB 2132-H 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 RGEN INT12 SI1_1 SI1_0 SB1_2 SB1_1 SB1_0 SO1_1 SO1_0 SO2_0 SO2_1 SB2_0 SB2_1 SB2_2 SI2_0 SI2_1 BCL FSC DU DD NU DD DU NU VDDD RESET# DCL GNDD DOUT DIN DCLK CS# CHCLK NC NUI NUI NUIO NUIO NUIO NC NC NC NC NUIO NUIO NUIO NUI NUI NC NC VIN2 VIN1 GNDA NC VDDA NC GNDA VDDREF VREF GNDA2 VOUT2 VDDA12 VOUT1 GNDA1 2132_204 P-MQFP-64

Hardware Reference Manual 6 2001-02-20

2.2 Pin Definitions and Functions

Table 1 Pin Definitions and Functions Pin Symbol Type Function Ch. 1, 2 NUI I Non Usable Input Pins must be tied directly to digital ground GNDD (Pin 21) 3, 4, NUIO I/O Non Usable Input/Output Pins must be tied via a pull-down-resistor to digital ground GNDD (Pin 21) 6, 7, 8, 9 NC Not Connected Pins are not connected in this device. 10, 11, NUIO I/O Non Usable Input/Output Pins must be tied via a pull-down resistor to digital ground GNDD (Pin 21) 13, NUI I Non Usable Input Pins must be tied directly to digital ground GNDD (Pin 21)

15 NC Not Connected

Pin is not connected in this device.

16 CHCLK O Chopper Clock Output

Provides 256, 512, or 16,384 kHz signal; sync. to DCL. both

17 CS# I Chip Select

Microcontroller Interface Chip Select, enable to read or write; active low. both

18 DCLK I Data Clock

Microcontroller Interface data clock, shifts data from or to device; maximum clock rate 8192 kHz. both

19 DIN I Data Input

Microcontroller Interface control data input pin; DCLK determines data rate. both

20 DOUT O Data Output

Microcontroller Interface control data output pin; DCLK determines data rate: DOUT is high impedance "Z" if no data is transmitted from the SICOFI ®2-TE. both

21 GNDD I Digital Ground

Ground reference for all digital signals. Internally isolated from GNDA1 (Pin 50), GNDA2 (Pin 54), and GNDA (Pins 59 and 63). both

Hardware Reference Manual 7 2001-02-20

22 DCL I Master Clock Input

1536 kHz signal must be applied for any operation. DCL, BCL, and FSC must be synchronous. both

23 RESET# I Reset Input

Forces the device to default setting mode; active low. both

24 VDDD I Digital Supply Voltage

+5 V supply for digital circuits (use 100 nF blocking cap.). both

25 NU None Usable

Leave unconnected.

26 DU I/O/

Interface together with Pin 30. Both pins must be connected together. Transmits or receives PCM data in 8-bit bursts every 125 µs. With push-pull resistor. both

27 DD I/O/

Interface together with Pin 29. Both pins must be connected together. Transmits or receives PCM data in 8-bit bursts every 125 µs. With push-pull resistor. both

28 NU None Usable

Leave unconnected.

29 DD I/O/

Interface together with Pin 27. Both pins must be connected together. Transmits or receives PCM data in 8-bit bursts every 125 µs. With push-pull resistor. both

30 DU I/O/

Interface together with Pin 26. Both pins must be connected together. Transmits or receives PCM data in 8-bit bursts every 125 µs. With push-pull resistor. both

31 FSC I Frame Synchronization Clock

8 kHz; reference for individual time slots, indicates start of PCM frame; DCL, BCL and FSC must be synchronous. both

32 BCL I IOM-2 Bit Clock

Determines rate at which PCM data is shifted into or out of PCM-ports. BCL, DCL, and FSC must be synchronous. If C-MODE = 0 in XR6, single clocking mode is used; 768 kHz must be applied to BCL. If C-MODE = 1 in XR6, double clocking mode is used; 1536 kHz must be applied to BCL. The data rate at the PCM ports remains 768 kbit/s. both Pin Symbol Type Function Ch.

Hardware Reference Manual 8 2001-02-20

33 RGEN O Ring Generator Output

Configurable output clock (2 … 28 ms) synchronous to DCL. Square-wave signal with duty cycle 1:1. both

34 INT12 O Interrupt Output, Channels 1 and 2

Active high. both

35 SI1_1 I Signaling Input Channel 1, Pin 1 1

36 SI1_0 I Signaling Input Channel 1, Pin 0 1

37 SB1_2 I/O Bi-directional Signaling, Channel 1 Pin 2 1

38 SB1_1 I/O Bi-directional Signaling, Channel 1 Pin 1 1

39 SB1_0 I/O Bi-directional Signaling, Channel 1 Pin 0 1

40 SO1_1 O Signaling Output, Channel 1, Pin 1 1

41 SO1_0 O Signaling Output, Channel 1, Pin 0 1

42 SO2_0 O Signaling Output, Channel 2, Pin 0 2

43 SO2_1 O Signaling Output, Channel 2, Pin 1 2

44 SB2_0 I/O Bi-directional Signaling, Channel 2 Pin 0 2

45 SB2_1 I/O Bi-directional Signaling, Channel 2 Pin 1 2

46 SB2_2 I/O Bi-directional Signaling, Channel 2 Pin 2 2

47 SI2_0 I Signaling Input, Channel 2, Pin 0 2

48 SI2_1 I Signaling Input, Channel 2, Pin 1 2

49 VIN1 I Analog Voice (Voltage) Input, Channel 1

Requires a coupling capacitor >39 nF to the SLIC.

50 GNDA1 I Analog Ground, Channel 1

Not internally connected to GNDD or GNDA2 or GNDA.

51 VOUT1 O Analog Voice (Voltage) Output, Channel 1

Requires a coupling capacitor to the SLIC. The capacitor value depends on the SLIC’s input impedance. (See Chapter 5.1, "Analog Interface" on page 25).

52 VDDA12 I Analog Supply Voltage, Channels 1 and 2

+5 V (100 nF blocking capacitor required). both

53 VOUT2 O Analog Voice (Voltage) Output, Channel 2

Requires a coupling capacitor to the SLIC. The capacitor value depends on the SLIC’s input impedance. (See Chapter 5.1, "Analog Interface" on page 25). Pin Symbol Type Function Ch.

Hardware Reference Manual 9 2001-02-20

54 GNDA2 I Analog Ground, Channel 2

Not internally connected to GNDD or GNDA1 or GNDA.

55 VIN2 I Analog Voice (Voltage) Input, Channel 2

Requires a coupling capacitor >39 nF to the SLIC.

56 VREF I/O Reference Voltage

Must connect to a 220 nF cap. to ground. both

57 VDDREF I Analog Supply Reference Voltage

+5 V (100 nF blocking capacitor required). both

58 NC Not Connected

Pin is not connected in this device.

59 GNDA I Analog Ground

Internally isolated from GNDD (Pin 21), GNDA1(Pin 50), and GNDA2 (Pin 54).

60 NC Not Connected

Pin is not connected in this device.

61 VDDA I Analog Supply Voltage

+5 V (100 nF blocking capacitor required).

62 NC Not Connected

Pin not connected in this device.

63 GNDA I Analog Ground

Internally isolated from GNDD (Pin 21), GNDA1(Pin 50), and GNDA2 (Pin 54).

64 NC Not Connected

Pin is not connected in this device. Pin Symbol Type Function Ch.

Hardware Reference Manual 10 2001-02-20

3 Functional Description

The SICOFI ®2-TE in combination with four Subscriber Line Interface Circuits (SLIC) provides four analog telephone lines. The SLIC can be either a transformer or an electronic circuit with operational amplifiers. It must have a defined input impedance towards the analog line for maximum power transfer and return loss. Also, the signal reflections that are generated by the hybrid inside the SLIC must be eliminated. Along with its other features, the SICOFI ®2-TE has built-in impedance matching and transhybrid balancing to perform these tasks.

3.1 DSP-based Architecture

The impedance matching and transhybrid balancing functions are performed by loop filters between the transmit path (analog to PCM) and the receive path (PCM to analog). The filter characteristics must be adjusted according to the local requirements of each market. In the analog domain, filters must be optimized in hardware; this is generally both tedious and time-consuming. This is not the case with the DSP-based SICOFI ®2- TE two-channel codec. Its integrated signal processor implements the impedance matching and transhybrid balancing functions as digital, programmable filters. It also performs frequency response corrections and level adjustments to enable the design of a truly universal and internationally applicable telephone interface. Transmission characteristics and frequency behavior are enhanced by the accuracy of the digital filters, which do not fluctuate over temperature or with age. As an additional benefit of its DSP-based architecture, the PSB 2132 also provides two tone generators per channel. An on-chip level-metering unit allows line-characterization without extra hardware; it can also be used to detect specific tones, e.g., modem tones.

3.2 Programming and Control

A very simple Microcontroller Interface is used to program the SICOFI ®2-TE functions. The same port provides access to 14 general purpose I/O pins of the Signaling Interface. This allows efficient and convenient monitoring and control of other tip/ring functions, such as on-/off-hook detection, ground-key detection, switching of ring signals and test relays. The Serial Microcontroller Interface provides a programming and control interface and is generic and non-proprietary for use with any microcontroller. It can be implemented with as few as three signal lines, since the data receive and data transmit pins may be strapped together.

Hardware Reference Manual 12 2001-02-20

4 Operational Description

Each channel of the SICOFI ®2-TE can be in one of two stable states: “Standby” and “Operating”. These states can be switched by programming Bit 0 (PU) in the channel-specific configuration register CR1. “Standby” is a power-saving state. Keeping any unused channels in this state reduces the overall system power dissipation. The third state, “Reset”, is transient and is reached after applying power to the device (Power On), after asserting a logic low signal to the RESET#-pin (HW-Reset), or after issuing an XOP command with Bit 7 (RST) set to "1" (SW-Reset). Both channels would be affected in any case.

4.1 Operating States

Figure 5 SICOFI ®2-TE State Diagram

4.1.1 Power On

All input pins must be at GND level before applying VDD to the SICOFI®2-TE. Otherwise, the device may not enter the Reset State. In this case, the SICOFI®2-TE can be reset by HW- or SW-Reset, or can be initialized by setting all registers to zero. 2132_206 Reset (both channels) Power-On HW-Reset SW-Reset Power Up Ch.2 Power Down Ch.2 Power Up Ch.1 Power Down Ch.1 Operating Ch.1 Standby Ch.1 Operating Ch.2 Standby Ch.2

Hardware Reference Manual 13 2001-02-20

4.1.2 Hardware Reset

Voltage levels lower than 1.2 V applied to Pin 23 (RESET#) for more than 3 µs will reset the SICOFI®2-TE. Spikes that are shorter than 1 µs will be ignored. When RESET# is released the SICOFI®2-TE will enter Standby State. Table 2 Register Values and Accessibility Table 3 Input and Output Pin Behavior Note: The 1536 kHz DCL clock must be applied for all device functions. Register SICOFI®2-TE State Reset Standby Operating CR0...CR4 00 H user configurable user configurable XR0...XR7 00 H user configurable user configurable CRAM unchanged user configurable user configurable Pin SICOFI®2-TE State Reset Standby Operating DIN ignored serial input serial input DOUT high impedance serial output serial output DU, DD inactive inactive receiving/transmitting PCM data during programmed time slot VOUT1 , VOUT2 high impedance high impedance analog output VIN1 , VIN2 ignored ignored analog input SBx_y configured as input programmable as input or output programmable as input or output SOx_y GNDD digital output digital output SIx_y ignored digital input digital input RGEN high programmable frequency programmable frequency CHCLK high programmable freq. (not 16,384 kHz) programmable frequency

Hardware Reference Manual 14 2001-02-20 Table 4 Power Dissipation

4.2 Transmission Characteristics

4.2.1 Overload Point

The overload point of the SICOFI ®2-TE A/D converters is at 2.223 V. This is the peak amplitude of a sine wave level of 1.572 Vrms. Higher input signal levels will be distorted. Theoretical load capacities for A-Law and µ-Law encoded signals are defined in ITU-T Recommendation G.711. These values correspond to the SICOFI®2-TE overload point: Table 5 Maximum Signal Levels 4.2.2 0 dBm0-Levels The analog voltage levels corresponding to a 0 dBm0 sine wave signal can be calculated from the maximum signal levels shown in Table 5. The results are shown in Table 6. Table 6 Analog Voltage Levels Corresponding to 0 dBm0-Level Note: Periodic PCM codes for a 1 kHz sine wave signal with 0 dBm0 level can be found in ITU-T G.711. No. of Channels Operating Typical Power Dissipation None 2.5 mW 1 70 mW 2 90 mW Encoding Law IOM-2 PCM Interface Analog Interface Theoretical Load Capacity (according to ITU-T G.711) Max. Sine Wave Level (SICOFI®2-TE Overload Point) A-Law 3.14 dBm0

1.572 Vrms

µ-Law 3.17 dBm0 Encoding Law Analog Sine Wave Level corresponding to 0 dBm0 PCM Level A-Law 1.572 Vrms*10^(-3.14/20) = 1.095 V rms µ-Law 1.572 Vrms*10^(-3.17/20) = 1.091 V rms

Hardware Reference Manual 15 2001-02-20

4.2.3 Compressor Gain Relative to Coding Law

The µ-Law compressor unit of the SICOFI ®2-TE automatically adds 1.94 dBm0 gain, which has to be considered for the total gain calculation. The accumulated gain of all programmable transmit filters (AX1+AX2+FRX) must not exceed 6 dB if the device is set to µ-Law operation. If the device is set to A-Law operation, then the accumulated gain must not exceed 8 dB. Figure 6 Analog and PCM Signal Levels in A-Law Mode Figure 7 Analog and PCM Signal Levels in µ-Law Mode A-Law Compressor Transmit A-Law Expander Receive 0d B m 0 1014 Hz 0d B m 0 DXA/B DXA/BA/D 0d B Gain D/A 0d B Gain VOUT VIN1014 Hz

1.095 Vrms

2132_207 A/D µ -Law Compressor [+1.94 dB] Transmit D/A µ -Law Expander Receive VOUT VIN1014 Hz 1.091 V rms

1.091 Vrms

1.94 dBm0 1014 Hz 0d B m 0 DXA/B DXA/B0d B Gain 0d B Gain 2132_208

Hardware Reference Manual 16 2001-02-20

4.2.4 Operating Conditions

The figures in this document are based on the subscriber-line board requirements. Proper adjustment of the programmable filters (transhybrid balancing, impedance matching, frequency-response correction) requires a complete knowledge of the analog environment in which the SICOFI ®2-TE is to be used. Unless otherwise stated, the transmission characteristics are guaranteed within the following operating conditions:  TA = 0 °C to 70 °C;  VDD = 5 V ± 5%;  GNDA1,2,3,4 = GNDD = 0 V;  Load on VOUT: RL > 300 Ω; CL < 50 pF;  H(IM) = H(TH) = 0;  H(R1) = H(FRX) = H(FRR) = 1;  HPR and HPX enabled;  AR = 0 to –8 dB (AR = AR1 + AR2 + FRR + R1);  AX = 0 to +8 dB for A-Law, AX = 0 to +6 dB for µ-Law (AX = AX1 + AX2 + FRX);  f = 1014 Hz; 0 dBm0; A-Law or µ-Law;  AGX = 0 dB, +6.02 dB; and  AGR = 0 dB, –6.02 dB. Figure 8 Simplified Signal Flow Diagram 2132_209 ADC DAC Receive Path Transmit Path Analog Output Analog Input PCM Input PCM Output IM AGR R1 AR2 FRR AR1 EXP CMPAX1FRXAX2AGX TH HPX HPR

4.2.5 Gain Accuracy

4.2.6 Gain Tracking (Receive and Transmit)

Table 8. All values are relative to the gain of a 0 dBm0 input signal.

Hardware Reference Manual 18 2001-02-20

4.2.7 Frequency Response

Table 9 Attenuation with Frequency in Transmit and Receive Direction

4.2.8 Group Delay

4.2.8.1 Group Delay, Absolute Values

Table 10 shows the limit values for the Absolute Group Delay. The maximum delays are valid when the SICOFI®2-TE is operating with H(TH) = H(IM) = 0, and H(FRR) = H(FRX) = 1, and include the delay through the A/D and D/A converters. The typical delays are the average of all different time slot delays during one IOM-2 frame. Table 10 Group Delay, Absolute Values Input Frequency Receive Loss Transmit Loss Unit Test Conditions min. max. min. max.

0 Hz to 100 Hz 0 > 2 dB 0 dBm0 input signal

level. 1014 Hz reference frequency

100 Hz to 200 Hz 0 0 dB

200 Hz to 300 Hz -0.125 -0.125 1 dB > 3.4 kHz 0 0 dB Parameter Symbol Limit Values Unit Test Conditions min. typ. max. Transmit Delay DXA 300 375 450 µs 0 dBm0 input signal level, fTest at TGmin.Receive Delay DRA 300 375 450 µs

Hardware Reference Manual 19 2001-02-20

4.2.8.2 Group Delay Distortion with Frequency

The Group Delay Distortion in transmit and receive direction will stay within the limits shown in Table 11. Group Delay Distortion values are referenced to the minimum value of Group Delay (TGmin). Table 11 Group Delay Distortion with Frequency

4.2.9 Noise

Table 12 Idle Channel Noise in Transmit Direction Table 13 Idle Channel Noise in Receive Direction Frequency Symbol Limit Values Unit Test Conditions min. typ. max.

500 Hz to 600 Hz ∆tG 300 µs 0 dBm0 input signal level,

reference point is at TGmin.600 Hz to 1.0 kHz ∆tG 150 µs 1.0 kHz to 2.6 kHz ∆tG 100 µs 2.6 kHz to 3.0 kHz ∆tG 300 µs Parameter Symbol Limit Values Unit min. typ. max. A-Law, psophometric (VIN =0V ) NTP –66.0 dBm0p µ-Law, C-message (VIN =0V ) NTC 19.0 dBrnc0 Parameter Symbol Limit Values Unit min. typ. max. A-Law, psophometric (idle code + 0) NRP –85 –77.0 dBm0p µ-Law, C-message (idle code + 0) NRC 5 13.0 dBrnc0

Hardware Reference Manual 20 2001-02-20

4.2.10 Harmonic and Intermodulation Distortion

Table 14 Harmonic and Intermodulation Distortion

4.2.11 Total Distortion

Table 15 Signal-to-Total Distortion Ratio Measured with Sine Wave Figure 9 Total Distortion Measured with Sine-Wave, Receive and Transmit Parameter Symbol Limit Values Unit Test Conditions min. typ. max. Harmonic Distortion 2nd, 3rd order HD –44 dB 0 dBm0; f = 1014 Hz Intermodulation IMD IMD –46 –56 dB dB Equal-level, 4-tone method (EIA-464) at composite level of -13 dBm0; f = 300 Hz to 3400 Hz Input Level Symbol Min. Values Unit Test Conditions A-Law µ-Law -45 dB S/D 23.5 26.0 dB sine wave f=1014 Hz, receive and transmit, µ-Law: C-message weighted, A-Law: psophometrically weighted. -40 dB S/D 28.5 30.0 dB -30 dB S/D 34.5 34.5 dB > -28 dB S/D 35.4 35.4 dB 2132_210 -600 Input Level -50 -40 -30 -20 -10 0 dBm0 dB 23.5 -45 -28 34.5 28.5 A-Law -Lawµ 35.4 S/D

Hardware Reference Manual 21 2001-02-20

4.2.12 Single Frequency Distortion

Table 16 Single Frequency Distortion Any resulting signal with a frequency different from the test input signal will stay at least 28 dB below the input signal level.

4.2.13 Overload Compression

This is measured with a 1014 Hz sine-wave signal. The overload point in µ-Law Mode is at 3.17 dBm0. Figure 10 Overload Compression (µ -Law Coding, Transmit Direction)

4.2.14 Crosstalk

Table 17 Crosstalk Between Channels Test Input Signal Frequency Range max. Input Level Receive Direction 300 Hz to 3.4kHz 0 dBm0 Transmit Direction 0 Hz to 12 kHz 0 dBm0 Parameter Symbol Limit Values Unit Test Conditions min. typ. max. Crosstalk, 0dBm0 CT – 80 – 75 dB f= 200 Hz to 3400 Hz, any combination of directions and channels 2132_213 Fundamental Input Power Fundamental dBm0 0.25 -0.25 1234567 d B m 0 9 Output Power

Hardware Reference Manual 22 2001-02-20

4.2.15 Out-of-Band Discrimination in Transmit Direction

With any 0 dBm0 sine-wave signal below 100 Hz and in the range from 3.4 kHz to 100 kHz (out-of-band signal) applied to an analog input (V INx), the level of any resulting frequency component at the digital output will stay at least X dB (see Table 18) below the output level of a 0 dBm0 1kHz sine-wave reference signal at the analog input. Table 18 Out-of-Band Signals Applied to the Analog Inputs (V INx) The Hardware Filters behind the A/D Converters reject teletax pulses with their poles at 12 kHz ±150 Hz and 16 kHz ±150 Hz. Figure 11 Out-of-Band Discrimination in Transmit Direction Input Frequency Min. Output Signal Rejection X Unit Test Conditions

0 Hz to 60 Hz 25 dB 0 dBm0 sine-wave input

signal on VIN60 Hz to 100 Hz 10 dB 3.4 kHz to 4 kHz dB 4 kHz 15 dB 4 kHz to 4.6 kHz dB 4.6 kHz to 100 kHz 40 dB 14– π 4000 f– 18– π 4000 f– sin 7 9---– kHz f 1000.06 0.1 3.4 4 4.6 6 10 18 dB Transmit Out-of-Band Discrimination X 2132_214

Hardware Reference Manual 23 2001-02-20

4.2.16 Out-of-Band Discrimination in Receive Direction

With any 0 dBm0 sine-wave frequency in the range from 300 Hz to 3.99 kHz applied to the digital input (DU or DD), the level of any resulting out-of-band signal at the analog output will stay at least X dB (see Table 19) below the output level of a 0 dBm0 1kHz sine-wave reference signal at the digital input. Table 19 Out-of-Band Signals at the Analog Outputs (V OUTx) Figure 12 Analog Output: Out-of-Band Signals

4.2.17 Out-of-Band Idle Channel Noise at Analog Output

With an idle code (any sequence of constant PCM octets) applied to the digital input, the level of any resulting out-of-band power spectral density at the analog output, measured with 3 kHz bandwidth, will be not greater than the limit curve shown in Figure 13. Output Frequency Min. Output Signal Rejection X Unit Test Conditions 3.4 kHz to 4.6 kHz dB 0 dBm0 sine-wave input signal on digital input (DU or DD) 4.6 kHz to 10.55 kHz dB 4 kHz 15 dB 4.6 kHz 28 dB >10.55 kHz 57 dB 14– π 4000 f– 35 22 f 4600– kHz f 1000.06 0.1 3.4 4 4.6 6 10 18 dB Receive Out-of-Band Discrimination X 10.55 8 16 2132_215

Hardware Reference Manual 24 2001-02-20 Figure 13 Analog Output: Out-of-Band Idle Channel Noise

4.2.18 Transhybrid Loss

The quality of Transhybrid-Balancing is very sensitive to deviations in gain, group delay, and deviations inherent to the A/D- and D/A-converters, as well as to all external components used with a tip/ring interface (SLIC, OP’s etc.). Transhybrid loss test setup: The SICOFI®2-TE test loop “DLB-ANA” is selected (see Figure 31), which connects the analog output with the analog input. The programmable filters FRR, AR, FRX, AX are by-passed. The IM-filter is disabled, (H(IM)=0). The balancing filter TH is enabled with optimized coefficients for this configuration (VOUT = VIN). A 0 dBm0 sine wave signal with a frequency in the range of 300 Hz to 3400 Hz is applied to the digital input. The signal levels of the resulting echo at the digital output will stay below the values shown in Table 20. Table 20 Transhybrid Loss Input Frequency Symbol Transhybrid Loss Unit Test Condition min. typ.

300 Hz THL300 19 40 dB TA = 25 °C; VDD = 5 V

AGX = AGR = 0 dB; typical variation of amplitude: ± 0.15 dB delay: ± 0.5 µs.

500 Hz THL500 25 45 dB

2500 Hz THL2500 21 40 dB

3000 Hz THL3000 19 35 dB

3400 Hz THL3400 19 35 dB

-100 f 1012 10 310 410kHz -90 -80 -70 -60 -50 -40 dBm0 -55 -78 Out of Band Noise 2132_216

Hardware Reference Manual 25 2001-02-20

5 Interface Description

The SICOFI®2-TE provides four interfaces:  Analog Interface,  IOM-2 PCM Interface,  Signaling Interface, and  Serial Microcontroller Interface. A general description of these interface is given in the Product Overview, Chapter 4. Refer to the Programmers Reference Manual for information on the configuration and operation of the four interfaces. The subsequent chapters in this manual explain how to connect the SICOFI ®2-TE to subscriber line interface circuits (SLICs), microcontrollers, and IOM-2 Interface.

5.1 Analog Interface

The Analog Interface in combination with a Subscriber Line Interface Circuit (SLIC) forms a configurable tip/ring (t/r) telephone line. The AC transmission characteristic of the SICOFI®2-TE— SLIC combination can be controlled by programming the digital filter structures inside the SICOFI®2-TE. The correct filter coefficients are determined by the targeted AC transmission behavior (e.g. Telco specification) and by the transfer functions of the SLIC. The SICOFI®2-TE can be interfaced directly to electronic SLICs or transformer solutions. The high driving capability of up to 300 Ohms eliminates the need for an external amplifier that is normally used with transformer SLICs. The peak amplitude of the analog inputs and outputs is at 2.223 V (overload point). Out-of-band signals applied to the analog inputs are suppressed by the on-chip digital hardware filters. The poles of these filters are fixed at 12 kHz and 16 kHz which suppresses the echo signal from teletax pulses very efficiently: As long as the amplitude of the teletax echo stays below the overload threshold of 2.223 Vp (1.57 Vrms), the voice signal in the transmit path will not be disturbed. Thus, the on-chip hardware filters can eliminate the need for external teletax filters.

5.1.1 Coupling Capacitors at the Analog Interface

A coupling capacitor >39 nF must be used on the VIN-pins in the transmit direction. The required value for the coupling capacitor on the VOUT-pins depends on the input resistance of the SLIC-circuitry ( RLoad). It has to be chosen to fulfil the frequency response requirement in the receive direction. Figure 14 can be used to determine an appropriate value for the coupling capacitor (CExt1).

Hardware Reference Manual 26 2001-02-20 Figure 14 Analog Interface to Two Subscriber Line Interface Circuits (SLICs) RLoad Ext1C 10 -3 10 23 10 410 -210 -110 110 210 010 F Ω µ 510 610 CExt1= fmin·RLoad fmin = 250 Hz 5756 50 54 VDDA12 VREF VDDREF SICOFI2-TE 100nF220nF Channel 1 VIN1 VOUT1 GNDA1 Channel 2 VIN2 VOUT2 GNDA2 CExt1 CExt1 > 39nF > 39nF 100nF 100nFSLIC 1 t/r RLoad SLIC 2 t/r RLoad 2132_217

Hardware Reference Manual 27 2001-02-20

5.1.2 Analog Interface Pins

Table 21 Analog Interface Pins

5.2 IOM-2 PCM Interface

The SICOFI ®2-TE’s IOM-2 PCM Interface can be connected directly to an IOM-2 interface in terminal mode (3 IOM channels, 768 kbit/s). The device uses the IOM-clock DCL at 1536 kHz as a master clock. The bit clock input BCL can be at either 768 kHz or 1536 kHz. FCS is an 8 kHz input. The SICOFI ®2-TE has data input Pin 30 and data output Pin 26 assigned to the IOM Data Upstream signal, DU. Further, input Pin 27 and output Pin 29 are assigned to the IOM Data Downstream signal, DD. This configuration allows transmission and reception of PCM data on either DU or DD. It further enables internal connections of channels, by programming the receive time slot of one channel to the transmit time slot of the other channel, and vice versa. The IOM-2 PCM Interface has the following characteristics and features:  Data rate of 768 kbit/s,  Bit clock input (BCL) configurable for 768 kHz or 1536 kHz,  IOM-2 DCL signal used as 1536 kHz master clock for the device; must be applied for all device functions,  12 time slots per IOM-2 frame,  PCM data format serialized 8 bits with MSB first,  Configurable A-Law or µ-Law coding,  Independent time slot assignment for each channel and direction,  Internal voice connection between channels possible,  Programmable sampling slopes,  Programmable frame delay. Symbol Pin Function VIN1 49 Analog Input, Channel 1, 2 Requires a coupling capacitor >39 nF to the SLIC, see Figure 14.VIN2 55 VOUT1 51 Analog Output, Channel 1, 2 Requires a coupling capacitor to the SLIC. The capacitor’s value depends on the input impedance of the SLIC, see Figure 14.VOUT2 53 GNDA1 50 Analog Ground, Channel 1, 2 Not internally connected to GNDD or the other GNDAx. GNDA2 54 VDDA12 52 Analog Supply Voltage, Channels 1+2 +5 V (100 nF blocking capacitor required, see Figure 14). VDDREF 57 Analog Supply Reference Voltage, +5 V (100 nF blocking capacitor required, see Figure 14). VREF 56 Reference Voltage Must connect to a 220 nF cap. to ground, see Figure 14.

Hardware Reference Manual 28 2001-02-20

5.2.1 IOM-2 PCM Interface Pins

Table 22 IOM-2 PCM Interface Pins

5.2.2 IOM-2 PCM Time Slot Configuration in TE Mode

Each voice channel should be assigned to one of the following time slots: B1, B2, IC1, IC2, IC3, or IC4. Figure 15 and Table 23 illustrate the time slot and bit positions resulting from the programming example below: Table 23 IOM-2 Time Slot Selection Symbol Pin Function DCL 22 Master Clock input, 1536 kHz. BCL 32 Bit Clock input at 768 kHz or 1536 kHz. FSC 31 Frame Synchronization Clock, 8 kHz. DD 27 Data Downstream input, connect to Pin 29. DU 30 Data Upstream input, connect to Pin 26. DU 26 Data Upstream output, connect to Pin 30. DD 29 Data Downstream output, connect to Pin 27. IOM-2 Time Slot Reception on: Transmission on: DD DU DU DD B1 CR4 = 0000 0000 CR4 = 1000 0000 CR5 = 0000 0000 CR5 = 1000 0000 B2 CR4 = 0000 0001 CR4 = 1000 0001 CR5 = 0000 0001 CR5 = 1000 0001 IC1 CR4 = 0000 0100 CR4 = 1000 0100 CR5 = 0000 0100 CR5 = 1000 0100 IC2 CR4 = 0000 0101 CR4 = 1000 0101 CR5 = 0000 0101 CR5 = 1000 0101 IC3 CR4 = 0000 1000 CR4 = 1000 1000 CR5 = 0000 1000 CR5 = 1000 1000 IC4 CR4 = 0000 1001 CR4 = 1000 1001 CR5 = 0000 1001 CR5 = 1000 1001

Hardware Reference Manual 29 2001-02-20 Figure 15 IOM-2 PCM Interface Time Slot Positions

5.3 Signaling Interface

The SICOFI®2-TE Signaling Interface is used to monitor and control supervision and signaling functions on up to four subscriber lines. The device generates interrupt signals to indicate signaling status changes on any of the input pins. The Signaling Interface consists of the following I/O pins and functions:  14 signaling pins (2 input pins, 2 output pins, and 3 user-configurable bi-directional pins per channel),  Debouncing functions,  1 interrupt output, indicating changes on any of the signaling inputs,  1 output signal for ringing,  1 chopper clock output. B1 B2 DC I 0MON0 IC1 IC2 CI1MON1 IC3 IC4 TIC 125 µs MR MX MR MX 7 6 5 4 3 2 1 0 ... ... DU/DD FSC DCL BCL DU/DD 2132_218

Hardware Reference Manual 30 2001-02-20

5.3.1 Signaling Interface Pins

Figure 16 Signaling Example: Two Subscriber Lines Table 24 Signaling Interface: Pins and Functions for SLIC Interfaces Table 25 Channel 1 Channel 2 Pin Symbol Function Pin Symbol Function

36 SI1_0 Signaling Input 0 47 SI2_0 Signaling Input 0

35 SI1_1 Signaling Input 1 48 SI2_1 Signaling Input 1

41 SO1_0 Signaling Output 0 42 SO2_0 Signaling Output 0

40 SO1_1 Signaling Output 1 43 SO2_1 Signaling Output 1

39 SB1_0 Bi-directional Signaling 0 44 SB2_0 Bi-directional Signaling 0

38 SB1_1 Bi-directional Signaling 1 45 SB2_1 Bi-directional Signaling 1

37 SB1_2 Bi-directional Signaling 2 46 SB2_2 Bi-directional Signaling 2

34 INT12 Interrupt Output, Channels 1+2, active high

SI1_0 SI1_1 SB1_2 SO1_1 SB1_1 Channel 1 SO1_0 SB1_0 Channel 2 SI2_0 SI2_1 SB2_2 SO2_1 SB2_1 SO2_0 SB2_0 SICOFI2-TE INT 12 Operating Mode Off-Hook Det. Status LED Status LED Ground Key Det. SLIC 2SLIC 1 Operating Mode Off-Hook Det. Ground Key Det. RGEN Microcontroller RWG Input CHCLK RWG Input Polarity Rev. Polarity Rev. Tip Ring Tip Ring 3416 2132_220

Hardware Reference Manual 31 2001-02-20

5.3.2 Debouncing Functions and Interrupt Generation

All signaling inputs are sampled at programmable intervals (Field N in register XR4). If all the inputs assigned to one channel-pair (1&2) have been stable for two subsequent samples their values are stored in the signaling registers and the associated interrupt output (INT12) is set high. The debouncing functions and interrupt generation require a 1536 kHz signal on Pin 22 (DCL). If, for power savings reasons, DCL is temporarily disabled, a signaling change interrupt can be generated by external hardware. Refer to the Programmer’s Reference Manual for further details on this function.

5.3.3 Clock Output Signals

Two programmable Clock Output signals are provided by the PSB 2132:  RGEN (Pin 33) divided by two can drive the ring input of a ringing SLIC. It is configured in register XR4.Field T.  CHCLK (Pin 16) is configured in register XR5.CHCLK.  CHCLK = 16,384 kHz: Requires at least one channel in POWER-UP state. Table 26 Clock Programming

5.4 Serial Microcontroller Interface

The Serial Microcontroller Interface is used to access the SICOFI ®2-TE’s internal registers and the Coefficient RAM (CRAM). The Serial Microcontroller Interface consists of four pins: two data pins (DIN, DOUT), one clock pin (DCLK) and one pin for chip select (CS#). If DIN and DOUT are strapped together, only three microcontroller I/O pins are required to build this interface. REGEN CHCLK XR4.Field T Output (Pin 33) XR5.CHCLK Output (Pin 16)

0000 High level (+5V) 00 High level (+5V)

Clock period = T *2ms (min. 2 ms, max. 28 ms) 01 512 kHz signal 10 256 kHz signal

1111 Low level (0V) 11 16,384 kHz signal

Hardware Reference Manual 32 2001-02-20 Figure 17 Serial Microcontroller Interface

5.4.1 Serial Microcontroller Interface Pins

Table 27 Serial Microcontroller Interface: Pins and Functions

5.4.2 Write Access

Following a falling edge of CS#, the first eight bits received on DIN specify the type of command. The data bytes following a write command are stored in the selected configuration registers or the selected part of the Coefficient RAM. The number of data bytes depends on the type of command. After every command CS# must be set to ’1’. Symbol Pin Function CS# 17 Chip Select, enable to read or write data, active low. DCLK 18 Data Clock, shifts data from or to device; max. clock rate is 8192 kHz. DIN 19 Control Data Input; sampled with rising edge of DCLK. DOUT 20 Control Data Output; bits are shifted with the falling edge of DCLK; DOUT is in high impedance state when no data is transmitted from the SICOFI ®2-TE. SICOFI2-TE Microcontroller Out InOut Out CS# DOUTDCLK DIN SICOFI2-TE Microcontroller Out Out I/O CS# DOUTDCLK DIN Configuration A: Separate DIN, DOUT Configuration B: Bi-Directional Data 2132_221

Hardware Reference Manual 33 2001-02-20 Figure 18 Example for a Two-Byte Write Access

5.4.3 Read Access

If the first eight bits received via DIN represent a read command, the SICOFI ®2-TE will initiate its response via DOUT. An identification byte (81 H) is followed by the requested number of data bytes (contents of configuration registers or contents of the CRAM). During execution of a read command, the device will ignore data on DIN. After every command CS# must be set to ’1’. Figure 19 Example for a One-Byte Read Access For byte-by-byte transfer, the high time of DCLK can be prolonged, resulting in a user-defined ‘waiting time’ between bytes. This mechanism can be used for writing to and reading from the device. 2132_222 76543210 0 12345670 1234567DIN DOUT DCLK CS# Write Command Data Byte 1 Data Byte 2 High 'Z' 2132_223 76543210DIN DOUT DCLK CS# Read Command Data Byte 1 High 'Z' 7654321076543210 High 'Z' Identification 81H

Hardware Reference Manual 34 2001-02-20 Figure 20 Example for a Read Access with Byte-by-Byte Transfer Read and write commands can be chained by leaving CS# low after the completion of each command sequence. For read or write access to individual registers, the command sequence may be terminated by rising CS# after the transmission of any number of bytes.

5.4.4 Three-Wire Access

DIN and DOUT may be strapped together and connected to a single I/O pin of the microcontroller. The interface remains fully functional with only three wire connections. After every command CS# must be set to ’1’. Figure 21 Bi-Directional Data Signal: DIN and DOUT Strapped Together 2132_224 76543210DIN DOUT DCLK CS# Read Command Data Byte 1 High 'Z' High 'Z'7654321 0 76543210 Identification 81H 2132_225 DATA DCLK CS# Read Command Identification 81 H High 'Z' Data Byte 1 76543210 76543210 76543210

Hardware Reference Manual 35 2001-02-20

6 Programming Overview

The transmission characteristics and interfaces of the PSB 2132 can be adapted to various environments. Configuring the functional blocks and programming the digital filter behavior is accomplished by loading values to the Configuration Registers and the Coefficient RAM (CRAM). Software utilities are available to determine the appropriate register and CRAM values (see Programmer’s Reference Manual).

6.1 Programming Overview

The SICOFI®2-TE has eight Common Configuration Registers (XR0 to XR7). Settings in these registers affect all two channels. Each of the two channels has six Channel-Specific Configuration Registers (CR0 to CR5). Settings in these registers affect only the designated channel. The filters of each channel are individually programmable through channel-specific coefficients in CRAM. There are two global sets of TH Filter coefficients that can be assigned to either channel. All of the filter blocks and their locations are illustrated in Figure 8.

6.1.1 Register Model

Channel-specific and Common Configuration Registers and coefficients are shown in Table 28. Table 28 Register Model Configuration Registers and CRAM Channel Usage XR0 to XR7 (8 bytes) common CR0 to CR5 (6 bytes) channel-specific IM/R1 Coefficients (16 bytes) FRR, FRX Coefficients (16 bytes) AR1, AR2, AX1, and AX2 Coefficients (8 bytes) TG1 and TG2 Coefficients (8 bytes) TH Coefficient Set 1 (24 bytes) one coefficient set per channelTH Coefficient Set 2 (24 bytes)

Hardware Reference Manual 36 2001-02-20

6.1.2 Register Maps

Table 29 Read Access to Common Configuration Register (XR) Map Table 30 Write Access to Common Configuration Register (XR) Map Table 31 Channel-Specific Configuration Register (CR) Map (Read & Write) B i t 7B i t 6B i t 5B i t 4B i t 3B i t 2B i t 1B i t 0 XR0 0 0 0 0 SI2_1 SI2_0 SI1_1 SI1_0 XR1 0 0 0 0 SB2_1 SB2_0 SB1_1 SB1_0 XR2 0 0 0 0 PSB2_1 PSB2_0 PSB1_1 PSB1_0 XR3 0 0 SB2_2 SB1_2 0 0 PSB2_2 PSB1_2 XR4 Field N (Signal Debounce) Field T (Configure RGEN) XR5 0 0 CR_DU CR_DD CHCLK Version XR6 C-Mode X-S R-S DRV_0 Shift PCM-OFFSET XR7 O F 7O F 6O F 5O F 4O F 3O F 2O F 1O F 0 B i t 7B i t 6B i t 5B i t 4B i t 3B i t 2B i t 1B i t 0 XR0 0 0 0 0 SO2_1 SO2_0 SO1_1 SO1_0 XR1 0 0 0 0 SB2_1 SB2_0 SB1_1 SB1_0 XR2 0 0 0 0 PSB2_1 PSB2_0 PSB1_1 PSB1_0 XR3 0 0 SB2_2 SB1_2 0 0 PSB2_2 PSB1_2 XR4 Field N (Signal Debounce) Field T (Configure RGEN) XR5 0 0 CR_DU CR_DD CHCLK Version XR6 C-Mode X-S R-S DRV_0 Shift PCM-OFFSET XR7 O F 7O F 6O F 5O F 4O F 3O F 2O F 1O F 0 B i t 7B i t 6B i t 5B i t 4B i t 3B i t 2B i t 1B i t 0 CR0 TH IM/R1 FRX FRR AX AR TH-SEL CR1 ETG2 ETG1 PTG2 PTG1 LAW 0 0 PU CR2 COT/R 0 IDR LM LMR V+T CR3 TEST-Loops AGX AGR D-HPX D-HPR CR4 RLINE 000 RS3 RS2 RS1 RS0 CR5 XLINE 000 XS3 XS2 XS1 XS0

Hardware Reference Manual 37 2001-02-20

6.1.3 CRAM Structure

Coefficient RAM (CRAM) is used to store the individual coefficients calculated for each channel. The coefficients can be written and read through the Microcontroller Interface. The IM, FRX, FRR, AX, AR, TG1, TG2, and TH coefficients are accessed through the Coefficient Operation (COP) Command Sequences which include the channel address (see Programmer’s Reference Manual Chapter 6.5). Channel-specific coefficients always belong to their designated channel. Common coefficients (TH) can be assigned to any of the two channels through field TH-SEL in CR0 (see Figure 22). Figure 22 Channel-Specific and Common Coefficients Table 32 Coefficient RAM (CRAM) Structure per Channel IM Part 1 8 Coefficient Bytes IM Part 2 8 Coefficient Bytes FRX 8 Coefficient Bytes FRR 8 Coefficient Bytes AX 4 Coefficient Bytes AR 4 Coefficient Bytes TG1 4 Coefficient Bytes TG2 4 Coefficient Bytes 2132_226 Common Coefficients Channel Specific Coefficients Set 1 TH Part 1, 2, 3 Set 2 TH Part 1, 2, 3 Channel 2 IM Part 1 & 2, FRX, FRR, AX, AR, TG1, TG2 Channel 1 IM Part 1 & 2, FRX, FRR, AX, AR, TG1, TG2 Channel Specific Coefficients

Hardware Reference Manual 38 2001-02-20 Table 33 Coefficient RAM (CRAM) Structure per Set

6.2 Types of Commands and Data Bytes

Coefficients and register contents are programmed and accessed through command sequences via the Microcontroller Interface. There are three types of command sequences:  Extended Operation (XOP) for access to the Common Configuration Registers (XR0 to XR7) including the Control Registers for the signaling interface.  Status Operation (SOP) for access to the Channel-Specific Registers (CR0 to CR5), e.g. enabling and disabling of filters, time slot assignment, and test loops.  Coefficient Operation (COP) for access to the CRAM structures. Coefficients can be written to the SICOFI®2-TE, and also read back. Table 34 Types of Commands and Data Bytes. With the first byte received via DIN, a command type is selected through bits 3 and 4. A two-bit address field (AD) in the COP and SOP commands allows access to the channel-specific structures (CRAM and CR registers). Since the XR Registers are common for all channels, no address field is required within the XOP command byte. All three commands allow read and write access, which is indicated by bit 5 (RW). The bit fields LSEL and CODE specify the type and the length of data that follows the command. TH Part 1 8 Coefficient Bytes TH Part 2 8 Coefficient Bytes TH Part 3 8 Coefficient Bytes 76543210 XOP RST 0 RW 11 LSEL SOP AD RW 10 LSEL COP AD RW 0 CODE

Hardware Reference Manual 39 2001-02-20

7 Application Hints

7.1 Support Tools

7.1.1 Development Board

The Evaluation Package EASY 2466 includes the following hardware:  One SICOFI ®2-TE Evaluation Board STUT 2466 with connectors for four optional SLIC daughter cards and BNC connectors to a PCM backplane.  One microcontroller board EVC50x with RS-232 interface that translates data from a PC to SICOFI®2-TE format.  Two SLIC Babyboards STUT 5502 with HARRIS SLIC HC 5502 mounted. The QSICOS software enables the calculation of the coefficients and the download of the setup file to the evaluation board. This setup allows measurements and optimization of the actual behavior of a complete transmission system. The EASY 2466 evaluation system connects directly to industry-standard test equipment. Figure 23 Development System with STUT 2466 Evaluation Board SICOFI-xµc Eval. Board V1.3 STUT 2466 SLC2 SLC1 SLC4 SLC3 out in in/ out in/ out ST2 ST1 SICOFI4 -µC PCM PCLK FSC Evaluation Board EVC50x sw1 RX Sign. TX Sign. TX Clock 4W i r e T X / R X Power Supply reset EVC SLIC (STUT5502) ST3 COM 1 DC Loop-Holding circuit FSC in tip ring PCM-4 PC

Hardware Reference Manual 40 2001-02-20

7.2 Guidelines for Board Design

7.2.1 Filter Capacitors

 For high frequency noise rejection, use 100 nF SMD ceramic capacitors on pins VDDA12, VDDA and VDDREF and connect to GNDA. Additional 2.2 µF tantalum capacitors are recommended.  Use one 100 nF SMD ceramic capacitor on pin VDDD and connect to GNDD.  Use a 1 µF – 10 µF tantalum capacitor from +5 V supply to GND (central blocking). Note: All blocking capacitors MUST be placed as close as possible to the SICOFI®2-TE pins. Figure 24 SICOFI ®2-TE Test Circuit Configuration SICOFI2-TE PSB 2132-H BCL FSC DU DD NU DD DU NU VDDD RESET# DCL GNDD DOUT DIN DCLK CS#NC NC VIN2 GNDA NC VDDA NC GNDA VDDREF VREF GNDA2 VOUT2 VDDA12 VOUT1 GNDA1 VIN1 RGEN INT12 SI1_1 SI1_0 SB1_2 SB1_1 SB1_0 SO1_1 SO1_0 SO2_0 SO2_1 SB2_0 SB2_1 SB2_2 SI2_0 SI2_1 CHCLK NC NUI NUI NUIO NUIO NUIO NC NC NC NC NUIO NUIO NUIO NUI NUI 1-10µF100nF 10K IOM-2 Interface Micro- controller Interface Signaling Interface, Channels 1&2 Analog Interface 2.2µF 100nF 11 6 3348 5 x 680K5 x 680K 10µF 1µF 2.2µF 100nF 1µF 220nF 2.2µF 100nF 100nF 100nF 10µF 6 x 680K 2132_228

Hardware Reference Manual 41 2001-02-20

7.3 Proposal for SICOFI ®2-TE Board Design

For a new layout design it is recommended to use a separate ground-layer which gives the possibilty to connect all ground-pins of the SICOFI ®2-TE (GNDA and GNDD) low- ohmic together. Furthermore, an optimum board layout should follow these recommendations  Separate all digital supply lines from analog supply lines as far as possible  Applying the standard practice regarding blocking capacitors is recommended  Place all SLIC circuits as close as possible to the Vinx/Voutx pins of the SICOFI  Separate all analog circuitry (especially SLIC and Vinx/Voutx) as far as possible from any digital signal source (esp. clock signals) Figure 25 Proposal for a Ground Concept VDD is the grey colored layer and the Ground-plane is the black colored layer. The Ground-plane should be on both sides of the board on the top and on the ground layer. 49 51 5352 55 56 5857 60 6261 64 100 nF GND 1-10 F Tantal VDD µ PSB 2132 H Ground- plane DDD GNDD V 1718192024 22232526272829303132 GNDA2 VDDA12 GNDA1 VDDREF VREF Connector Connector next to the connector pins Ceramic nF nF100 nF220 635954 Ceramic 100 Ceramic The ground-plane should be used for shielding SICOFI2-TE V2.2

Electrical Characteristics and Timing Diagrams Hardware Reference Manual 42 2001-02-20

8 Electrical Characteristics and Timing Diagrams

Note: Stresses above those listed here may cause permanent damage to the device. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.

8.1 Absolute Maximum Ratings

Conditionmin. max. VDD referred to GNDD –0.3 7.0 V GNDA to GNDD –0.6 0.6 V Analog input and output voltage Referred to VDD = 5 V; Referred to GNDA = 0 V –5.3 –0.3 0.3 5.3 V V All digital input voltages Referred to GNDD = 0 V; (VDD =5 V ) Referred to VDD = 5 V; (GNDD = 0 V) –0.3 –5.3 5.3 0.3 V V DC input and output current at any input or output pin (free from latch-up) 10 mA Storage temperature TSTG –60 125 °C Ambient temperature under bias TA –10 80 °C Power dissipation (package) PD 1W

Electrical Characteristics and Timing Diagrams Hardware Reference Manual 43 2001-02-20

8.2 Operating Range

VDD = 5 V ±5%; GNDD = 0 V; GNDA = 0 V; TA = 0 °C to +70 °C Parameter Symbol Limit Values Unit Test Condition min. typ. max. VDD supply current: IDD FSC = 8 kHz, FSC, DCL, BCL active no loads, PCM idle codes, VIN= 0V. Standby 0.5 1.0 mA 1 channel operating 14 25 mA 2 channels operating 18 30 mA Power supply rejection ratio (either direction) PSRR 30 dB Ripple: sine wave

1014 Hz, 70 mVrms,

on every supply pin, AGX=AGR=AX=AR=0dB (see Chapter 4.2.4)

8.3 Digital Interface

VDD = 5 V ± 5%; GNDD = 0 V; GNDA = 0 V; TA = 0 °C to +70 °C Parameter Symbol Limit Values Unit Test Condition min. max. Input voltages: Low level VIL –0.3 0.8 V High level VIH 2.0 V Output voltages: Low level VOL 0.45 V IOL = – 2m A Low level VOL 0.8 V IOL = – 5m A High level VOH 4.4 V IOH = 0.4 mA High level VOH 4.0 V IOH = 2 mA High level VOH 2.4 V IOH = 5 mA Input leakage current VIL ±1µ A –0.3 ≤ VIN ≤ VDD

Electrical Characteristics and Timing Diagrams Hardware Reference Manual 44 2001-02-20

8.4.1 Coupling Capacitors at the Analog Interface

Coupling capacitors are required on pins VIN and VOUT. The recommended value for VIN is >39 nF. The required value for the VOUT capacitor depends on the input impedance of the SLIC (see Figure 14 in Chapter 5.1).

8.5 Reset Timing

To reset the SICOFI®2-TE to Reset State, logic low pulses applied to pin RESET# must be below 1.2 V (TTL-Schmitt-Trigger Input) and must persist longer than 3 µs. Note: Spikes shorter than 1 µs will be ignored.

8.4 Analog Interface

VDD = 5 V ±5%; GNDD = 0 V; GNDA = 0 V; TA = 0 °C to +70 °C Parameter Symbol Limit Values Unit Test Condition min. typ. max. Input resistance Ri 160 270 380 kW 0 ≤ VIN ≤ VDD Output resistance RO 0.25 Ω Output load RL CL 300 Ω pF Input leakage current IIL ±0.1 ±1.0 µA 0 ≤ VIN ≤ VDD Input offset voltage VIO ±50 mV Output offset voltage VOO ±50 mV Input voltage range (AC) VIN ±2.223 V

Electrical Characteristics and Timing Diagrams Hardware Reference Manual 45 2001-02-20

8.6 IOM-2 PCM-Interface Timing

8.6.1 Single Clocking Mode

Figure 26 PCM Interface Timing in Single Clocking Mode Parameter Symbol Limit Values Unit min. typ. max. Period of BCL tBCL 1/768000 µs BCL high time tBCLh 0.4*tBCL tBCL/2 0.6* tBCL µs Period FSC tFSC 125 µs FSC setup time tFSC_s 10 50 ns FSC hold time tFSC_h 40 50 ns DU/DD setup time tDR_s 10 50 ns DU/DD hold time tDR_h 10 50 ns DU/DD delay time 1) 1) All delay times are made up by two components: an intrinsic time (min-time), caused by internal processing, and a second component tC_Load = 0.4ns*CLoad/pF, caused by external circuitry (C-load). tdDX 25 tdDX_min + tC_Load ns DU/DD delay time to high Z tdDXhz 25 50 ns 2132_229 t BCL BCL FSC DU/DD in DU/DD out FSC_St BCLht High Imp. t DR_S DR_Ht t dDX dDXhzt tFSC_H FSCt 50%

Electrical Characteristics and Timing Diagrams Hardware Reference Manual 46 2001-02-20

8.6.2 Double Clocking Mode

Figure 27 PCM Interface Timing in Double Clocking Mode Parameter Symbol Limit Values Unit min. typ. max. Period of BCL tBCL 1/1536000 µs BCL high time tBCLh 0.4*tBCL tBCL/2 0.6* tBCL µs Period FSC tFSC 125 µs FSC setup time tFSC_s 10 50 ns FSC hold time tFSC_h 40 50 ns DU/DD setup time tDR_s 10 50 ns DU/DD hold time tDR_h 10 50 ns DU/DD delay time 1) 1) All delay times are made up by two components: an intrinsic time (min-time), caused by internal processing, and a second component tC_Load = 0.4ns*CLoad/pF, caused by external circuitry (C-load). tdDX 25 tdDX_min + tC_Load ns DU/DD delay time to high Z tdDXhz 25 50 ns 2132_230 t BCL BCL FSC DU/DD in DU/DD out FSC_St BCLht High Imp. t DR_S DR_Ht tdDX dDXhzt tFSC_H FSCt 50%

Electrical Characteristics and Timing Diagrams Hardware Reference Manual 47 2001-02-20

8.7 Microcontroller Interface Timing

Figure 28 Timing of the Microcontroller Interface Parameter Symbol Limit Values Unit min. typ. max. Period of DCLK tDCLK 1/8192 ms DCLK high time tDCLKh 0.4*tDCLK tDCLK/2 0.6* tDCLK µs CS# setup time tCS_s 10 50 ns CS# hold time tCS_h 30 50 ns DIN setup time tDIN_s 10 50 ns DIN hold time tDIN_h 10 50 ns DOUT delay time 1) 1) All delay times are made up by two components: an intrinsic time (min-time), caused by internal processing, and a second component tC_Load = 0.4ns*CLoad/pF, caused by external circuitry (C-load). tdDOUT 30 tdDOUT_min + tC_Load ns DOUT delay time to high Z tdDOUThz 30 50 ns 2132_231 DCLK CS# DIN DOUT CS_St High Imp. t DIN_S DIN_Ht t dDOUT dDOUThz t t DCLKhDCLKt t CS_h 50%

Electrical Characteristics and Timing Diagrams Hardware Reference Manual 48 2001-02-20

8.8 Signaling Interface Timing

8.8.1 Timing from the Microcontroller Interface to the SO/SB-pins

Figure 29 Signaling Output Timing (Data Downstream)

8.8.2 Timing from the SI/SB-pins to the Microcontroller Interface

The register update and interrupt behavior resulting from signaling input changes (data upstream – pins SI and SB, if programmed as signaling inputs) depend on internal sampling clocks, counters and register settings. No external reference signal is available. See Chapter 5.3.2 for a functional description. Parameter Symbol Limit Values Unit min. typ. max. SO/SB delay time 1) 1) All delay times are made up by two components: an intrinsic time (min-time), caused by internal processing, and a second component tC_Load = 0.4ns*CLoad/pF, caused by external circuitry (C-load). tdSout 30 tdSout_min+ tC_Load ns SB to "Z" - time tdSBZ 40 100 ns SB to "drive"-time tdSBD 40 tdSBD_min+ tC_Load ns 2132_232 DCLK Bit 2DIN SO/SB Output Old Value New Value SB (Output Input) Output)(Input SB dSBDt High Imp. tdSBZ tdSout High Imp. Bit 1 Bit 0

Hardware Reference Manual 49 2001-02-20 9T e s t M o d e s Each SICOFI®2-TE channel has four test loops that feed the analog input signal back to the analog output (analog test loops), and five test loops that feed the PCM input signal back to the PCM output (digital test loops).. Note: The signal path can also be cut off at two different points per receive and transmit direction.

9.1 Analog Loops

The four analog loops feed signals from the transmit path back into the receive path. Figure 30 shows the locations of the analog loops. Figure 30 Analog Loops Table 35 Analog Loop Programming in Register CR3, Bits 7 to 4 Test-Loops Analog Loops (CR3.7 = 0) 0000 All loops are disabled (normal operation). 0001 ALB-PFI Analog Loop Back via PREFI-POFI is selected. 0011 ALB-4M Analog Loop Back via 4 MHz is selected.

0100 ALB-PCM Analog Loop Back via 8 kHz (PCM) is selected and in all

channels active. (required slope setting in XR6.6, XR6.5 = 00 or 11). 0101 ALB-8K Analog Loop Back via 8 kHz (linear) is selected. 2132_233 Receive Path Transmit Path Analog Output Analog Input PCM Input PCM Output IM1 TH Digital Gain 2 Digital Gain 2 IM2 Frequency Response Digital Gain 1 Frequency Response Digital Gain 1 HPX HPR ADC DAC AGX AGR CMP EXP ALB-PFI ALB-4M ALB-8K ALB-PCM

Hardware Reference Manual 50 2001-02-20

9.2 Digital Loops

The digital loops feed signals from the receive path back to the transmit path. There are five digital loops, which are shown in Figure 31. Figure 31 Digital Loops Table 36 Digital Loop Programming in Register CR3, Bits 7 to 4 Test-Loops Digital Loops (CR3.7 = 1) 1000 DLB-ANA Digital Loop Back via analog port is selected. 1001 DLB-4M Digital Loop Back via 4 MHz is selected. 1100 DLB-128K Digital Loop Back via 128 kHz is selected. 1101 DLB-64K Digital Loop Back via 64 kHz is selected. 1111 DLB-PCM Digital Loop Back via PCM Registers is selected. 2132_234 Receive Path Transmit Path Analog Output Analog Input PCM Input PCM Output IM1 TH Digital Gain 2 Digital Gain 2 DLB-PCM DLB-64K DLB-ANA DLB-4M IM2 DLB-128K Frequency Response Digital Gain 1 Frequency Response Digital Gain 1 HPX HPR ADC DAC AGX AGR CMP EXP

Hardware Reference Manual 51 2001-02-20

9.3 Cut-Off ’s

The transmit path and the receive path can be cut off at two locations each. Figure 32 shows the locations in the signal paths. Figure 32 Cut-Off ’s Table 37 Cut-Off Programming in Register CR2, Bits 7 to 5. COT/R Cut-Off ’s in the Transmit and the Receive Paths 000 All Cut-offs disabled (Normal Operation). 001 COT16 Cut Off Transmit path at 16 kHz (input of TH-Filter).

010 COT8 Cut Off Transmit path at 8 kHz (shortens the input of the

compressor unit to ground, resulting in PCM idle codes in the transmit time slot). 101 COR4M Cut Off Receive path at 4 MHz (POFI-output). 110 COR64 Cut Off Receive path at 64 kHz (IM-filter input). 2132_235 Receive Path Transmit Path Analog Output Analog Input PCM Input PCM Output IM1 TH Digital Gain 2 Digital Gain 2 IM2 Frequency Response Digital Gain 1 Frequency Response Digital Gain 1 HPX HPR ADC DAC AGX AGR CMP EXP COT8COT16 COR64 COR4M

Hardware Reference Manual 52 2001-02-20 P-MQFP-64 (Plastic Metric Quad Flat Package) GPM05250 Sorts of Packing Package outlines for tubes, trays etc. are contained in our Data Book “Package Information”. Dimensions in mmSMD = Surface Mounted Device

Hardware Reference Manual 53 2001-02-20

11 Glossary

ADC Analog-to-Digital Converter CMOS Complementary Metal Oxide Semiconductor CRAM Coefficient RAM DAC Digital-to-Analog Converter DC Direct Current DLC Digital Loop Carrier DSP Digital Signal Processor DTMF Dual Tone Multi Frequency FIR Finite Impulse Response FTTC Fiber-To-The-Curb IIR Infinite Impulse Response IOM-2 ISDN-Oriented Modular 2nd Generation ISDN Integrated Services Digital Network ITU International Telecommunication Union ITU-T International Telecommunication Union-Telecommunication Standardization Sector (formerly CCITT) NT Network Termination PBX Private Branch Exchange PCM Pulse Code Modulation POTS Plain Old Telephone System PSTN Public Switched Telephone Network PTT Post Telephone Telegraph QSICOS Quad SICOFI Coefficient Software RITL Radio-In-The-Loop RT Remote Terminal SICOFI Signal Processor Codec Filter SLIC Subscriber Line Interface Circuit t/r tip/ring TA Terminal Adapter

Hardware Reference Manual 54 2001-02-20 Index Symbols Numerics A A/D and D/A converters . . . 11, 14, 18, 22, 24 B C Channel-specific registers. . . .11, 12, 35, 36 Coefficient calculation & Coefficient Operation (COP) command . . . 38 Common configuration registers . . . 11, 35, 36

Hardware Reference Manual 55 2001-02-20 D E Extended Operation (XOP) command . . .38 F Frequency response corrections . . 10, 16

Hardware Reference Manual 56 2001-02-20 G H I IOM-2 PCM interface . . .2, 3, 11, 14, 25, 27 L M Microcontroller interface . . 10, 31, 37, 38 N

Hardware Reference Manual 57 2001-02-20 O P Q R

Hardware Reference Manual 58 2001-02-20 S Serial microcontroller interface . . . . 10, 25 Status Operation (SOP) command . . . 38 Subscriber line interface circuits . . .2, 10, 25 Supervision and signaling functions . . 29 T

Hardware Reference Manual 59 2001-02-20 Transhybrid balancing . . . . 3, 10, 11, 16, 24 Transmission characteristics . . . . 10, 14, 35 V W X

http://www.infineon.com Published by Infineon Technologies AG Infineon goes for Business Excellence “Business excellence means intelligent approaches and clearly defined processes, which are both constantly under review and ultimately lead to good operating results. Better operating results and business excellence mean less idleness and wastefulness for all of us, more professional success, more accurate information, a better overview and, thereby, less frustration and more satisfaction.” Dr. Ulrich Schumacher