PPM-Series – PPM01-S-xxELF – Single Output - Plasti c Case Specification can change without a notice – We acce pt no liability for any inaccuracy or printing errors. Page 1/3 PPM01-S-xxELF All specifications typical at Ta=25° C, nominal input voltage and full load unless otherwise specified Input Specifications Input Voltage Range 85 – 305 VAC or 120 – 430 VDC universal Input Frequency 47 – 63 Hz Input (Inrush) Current

115 VAC 230 VAC

30 mA (5A, typ.) 17mA (11A, typ.) External Input Fuse (recommended) 1A / 300V slow blow Output Specifications Voltage Accuracy ±5%, typ (±6% @3.3 Vout) Line Regulation (at full load) ±2% Load variation (10-100%) ±5% Ripple and Noise (20Mhz bandwidth) ≤ 100mV pk-pk Short Circuit Protection Continuous, auto recovery Common Specifications Temperature range -25° C to +70 ° C Power derating 3.3% / ° C, min Storage -40° C to +85 ° C Humidity (non condensing) 95%, max. Switching Frequency 100kHz I/O Isolation Voltage 3000VAC / 1min. EMI / RFI conducted EN55022, Class B EMC compliance ESD RS EFT Surge CS PFM Voltage dips, short and interruptions immunity IEC/EN 61000-4-2 Contact±8KV/Air±8KV perf. Criteria B IEC/EN 61000-4-3 10V/m perf. Criteria A IEC/EN 61000-4-4 ±2KV perf. Criteria B IEC/EN 61000-4-5 ±1KV/±2KV perf. Criteria B IEC/EN 61000-4-6 10Vr.m.s perf. Criteria A IEC/EN 61000-4-8 10A/m perf. Criteria A IEC/EN 610004-11 0%-70% perf. Criteria B Safety Standards IEC60950, EN60950, UL60950 Safety Class CLASS 2 Case Material UL94V-0 rated Reliability Calculated MTBF (MIL-HDBK-217F) > 300,000 hrs Weight ~ 20g Mainzer Straße 151–153 D-55299 Nackenheim Tel. +49 6135 7026-0 Fax: +49 6135 931070 www.peak-electronics.de peak@peak-electronics.de The PPM 5Series is a compact size power converter provided by Peak . The features of this series are: wide input voltage, DC and AC all in one, high efficiency, high reliability, low loss, safety isolation etc. They are widely used in industrial, office and civil equipments. EMC and safety standards meet international standards IEC61000, UL60950 and IEC60950, and Multi5certificate is in processing. PPM-SERIES /checkbld 1 Watt /checkbld Univ. 85-305VAC (120-430VDC) /checkbld Single Output /checkbld Over Voltage Protection (out) /checkbld 3 kV AC I/O Isolation /checkbld Low Ripple and Noise /checkbld High Efficiency Rev.12-2014

PPM-Series – PPM01-S-xxELF – Single Output - Plasti c Case Specification can change without a notice – We acce pt no liability for any inaccuracy or printing errors. Page 2/3 Selection Guide Single Output Order # Power (W) Output Voltage (Vdc) Output Current Full Load (mA) Capacitor Load µ F (max.) Efficiency (%) SINGLE OUTPUT PPM01-S-3R3ELF 1 3.3 300 4000 63 PPM01-S-05ELF 1 5 200 4000 68 PPM01-S-09ELF 1 9 111 2200 72 PPM01-S-12ELF 1 12 83 2200 73 PPM01-S-15ELF 1 15 67 1000 74 PPM01-S-24ELF 1 24 42 680 75 If you need other specifications, please enquire. Package / Pinning / Derating 15.24 (0.60) 22.20 (0.874) 0.6 (0.024) # SINGLE

1 AC (N)

2 AC (L)

PPM-Series – PPM01-S-xxELF – Single Output - Plasti c Case Specification can change without a notice – We acce pt no liability for any inaccuracy or printing errors. Page 3/3 App Notes: Parallel Line Measure Typical Application EMC Recommended Circuit EXTERNAL CAPACITORS TYPICAL VALUE(Unit: µµ µµ F) Model C1 C2 TVS PPM015S53R3ELF 1µF/50V 220 SMBJ7.0A PPM015S505ELF 1µF/50V 220 SMBJ7.0A PPM015S509ELF 1µF/50V 120 SMBJ12A PPM015S512ELF 1µF/50V 120 SMBJ20 A PPM015S515ELF 1µF/50V 120 SMBJ20 A PPM015S524ELF 1µF/50V 68 SMBJ30 A Note: 1. C1 is ceramic capacitor, it is used to filter high frequency noise. C2 is electrolytic capacitor, It is recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. TVS is a recommended component to protect post5circuits (if converter fails). 2. For standard EMC requirement, please refer to figure 1. If higher EMC requirement, please refer to figure 3, recommended parameters are shown in the table below. Recommend Parameter For High er EMC Standard Circuit Components Recommend Parameter MOV S14K350 CY3 2.2nF/400V CY4 2.2nF/400V CX 0.1 µF/305VAC LCM 10 mH NTC 5D-9 FUSE 1A/300V, slow blow, it must be connected to FUSE