PMI210-F110-IU-V1 PF | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Inductive positioning system PMI210-F110-IU-V1 < Measuring range 0 ... 210 mm Dimensions L17 41 ± 0.15 8 ± 0.15 30.5 0V/4mA 10V/20mA Technical Data General specifications Switching element function analog, current or voltage output Object distance max. 6 mm Measurement range 0 ... 210 mm Nominal ratings Operating voltage UB 18 ... 30 V DC Reverse polarity protection reverse polarity protected Linearity error ± 0.4 mm Repeat accuracy R ± 0.2 mm Resolution 210 µm Temperature drift ± 0.5 mm (-25 °C ... 70 °C) No-load supply current I0 ≤ 40 mA Operating voltage indicator LED green Functional safety related parameters Release date: 2021-04--

06 Date of

Release date: 2021-04-06 Date of issue: 2021-04-06 Filename: 191142_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 % Analog output Output type 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V Load resistor current output: ≤ 400 Ω voltage output: ≥ 1000 Ω Short-circuit protection voltage output: pulsing Compliance with standards and directives Standard conformity Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates UL approval cULus Listed, General Purpose, Class 2 Power Source CCC approval CCC approval / marking not required for products rated ≤36 V Ambient conditions Mechanical specifications Connection type 4-pin, M12 x 1 connector Housing length L 250 mm Degree of protection IP65 Material Housing PA 6 / AL Target mild steel, e. g. 1.0037, SR235JR (formerly St37-2) Note The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6 mm. Connection Core colours in accordance with EN 60947-5-2. + UB I U - UB (BN) (BK) (WH) (BU) I 0-10 V 4-20 mA IU Connection Assignment 1 BN 2 WH 3 BU 4 BK Wire colors in accordance with EN 60947-5-2 (brown) (white) (blue) (black) Inductive positioning system PMI210-F110-IU-V1 Release date: 2021-04-06 Date of issue: 2021-04-06 Filename: 191142_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

BT-F110-G Damping element for F110 housing sensors; front screw holes BT-F110-W Damping element for F110 housing sensors; lateral screw holes V1-G-2M-PVC Female cordset single-ended M12 straight A-coded, 4-pin, PVC cable grey MH-F110 Mounting bracket for mounting F110 series sensors Inductive positioning system PMI210-F110-IU-V1 Release date: 2021-04-06 Date of issue: 2021-04-06 Filename: 191142_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Release date: 2021-04-06 Date of issue: 2021-04-06 Filename: 191142_eng.pdf PMI210-F110-IU-V1 Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Inductive positioning system Instruction manual

  • Security advice
  • Sensor Properties The inductive positioning system F110 provides both, a current and voltage signal at the outputs, which is proportional to the position of the attenuating element.
  • Attenuating element The inductive position encoding system F110 is optimally adjusted to the geometry of the attenuating elements we offer (see accessories, below).
  • Installation and operation Notes on installation - A flush installation is possible. - Fixation and installation of the positioning system F110 is carried out by the use of t-slides. This provides a flexible adaptation to the field situation. - The distance between the measuring field (b ordered area at the front of the sensor) and the fixing base or fixing element of the attenuating element must at least be 6 mm.
  • Notes on operation The sensor accuracy can be guaranteed, when the spacing between attenuating element and sensor is within an interval of 1 ... 6 mm. When the attenuating element leaves the measurement range (figures below): - the last valid value is maintained at the voltage output until the attenuating element re-enters the valid range. - the last valid value is mainta ined at the current output for 0.5 seconds. Afterwards, the output changes to a fault current of 3.6 mA until the attenuating element re-enters the valid range.
  • Definition of measuring range / of measured position The measured attenuating elements (actuators) position refers to half its width (middle of the actuator). The measuring range starts and ends when the attenuating element overlaps the labeled measuring area on the sensor at transversal motion (see Installation This product must not be used in applications, where safety of persons depend on the correct device function. This product is not a safety device according to EC machinery directive. When using your own attenuating elements, you must ensure that the active surface of the attenuating element has a width of exactly 13 mm and overlaps the entire sensor width (41 mm). A different width has a direct impact on the achievable resolution and accuracy of the system. Spacing between sensor and attenuating element is from 0 ... 6 mm. Warning ≥ 4 ≥ 41 Objekt: Note screw

Release date: 2021-04-06 Date of issue: 2021-04-06 Filename: 191142_eng.pdf PMI210-F110-IU-V1 Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Inductive positioning system left figure above).

  • Accessories Straight cables:V1-G-2M-PVC (4 wire) Angled cables:V1-W-2M-PVC (4 wire) Attenuating elements Mounting brackets BT-F110-G BT-F110-W MH-F110 start of measuring range measured position end of measuring range labeled measuring area motion direction of actuator width w of actuator w/2 actuator