© TT Electronics plc General Note All data sheets are subject to change without notice. TT Electronics | Power Partners, Inc 43 Broad Street Suite B206, Hudson, MA 01749, USA. t: +1 (978) 567-9600 ISS.1 22/07/2020 Page: 1 Description: The PM201 series comprising single and multiple output models for 150 to 200 watts of continuous output power is specially designed for medical and ITE applications. They operate at 90 to 264 VAC input voltage without the need of a selector strap. All auxiliary outputs are with magnetic amplifier linear regulator to keep regulation. The units are constructed on a printed circuit board with a U– bracket for mechanical support and heat sinking. A cover and fan assembly can be added during manufacturing. Features:

  • Low safety ground leakage current
  • Meet EN55011, EN55022 and FCC Class B
  • Power Factor 0.98 typical
  • Short-circuit protection
  • Power Fail Detect (PFD) signal
  • 100% burn– in at full rated load
  • Optional cover and fan assembly
  • Remote inhibit– TTL high to disable output
  • Compliant with RoHS requirements Model1 Output #14 Output #22,4 Output #3 Output #43 Max. Output Power4 V1 Imin Imax Tol. V1 Imin Imax Tol. V1 Imin Imax Tol. V1 Imin Imax Tol. PM201-10B 5.1V 3A 35A ±2% 87.5W/175W N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PM201-10-3B 3.3V 3A 46A ±3% N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 75W/150W PM201-12B 12V 1.2A 16.7A ±2% N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 100W/200W PM201-13B 15V 1A 13.4A ±2% N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 100W/200W PM201-14B 24V 0.6A 8.4A ±2% N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 100W/200W PM201-16B 30V 0.5A 6.7A ±2% N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 100W/200W PM201-18B 48V 0.5A 4.2A ±2% N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 100W/200W PM201-23B 5.1V 3A 30A ±2% 12V 0A 8A ±4% N/A N/A N/A N/A N/A N/A N/A N/A 100W/200W PM201-24B 5.1V 3A 30A ±2% 15V 0A 6A ±4% N/A N/A N/A N/A N/A N/A N/A N/A 100W/200W PM201-25B 5.1V 3A 30A ±2% 24V 0A 4A ±4% N/A N/A N/A N/A N/A N/A N/A N/A 100W/200W PM201-27B 12V 1A 8.7A ±2% 24V 0A 4A ±4% N/A N/A N/A N/A N/A N/A N/A N/A 100W/200W PM201-30B 5.1V 3A 30A ±2% 12V 0A 8A ±4% -5V 0A 6A ±4% N/A N/A N/A N/A 100W/200W PM201-31B 5.1V 3A 30A ±2% 12V 0A 8A ±4% -12V 0A 4A ±4% N/A N/A N/A N/A 100W/200W PM201-32B 5.1V 3A 30A ±2% 15V 0A 6A ±4% -15V 0A 4A ±4% N/A N/A N/A N/A 100W/200W PM201-33B 5.1V 3A 30A ±2% 15V 0A 6A ±4% -12V 0A 4A ±4% N/A N/A N/A N/A 100W/200W PM201-36B 5.1V 3A 30A ±2% 12V 0A 8A ±4% 24V 0A 4A ±4% N/A N/A N/A N/A 100W/200W PM201-40B 5.1V 3A 30A ±2% 12V 0A 8A ±4% -12V 0A 4A ±4% 5V 0A 6A ±4% 100W/200W PM201-41B 5.1V 3A 30A ±2% 15V 0A 6A ±4% -15V 0A 4A ±4% 24V 0A 4A ±4% 100W/200W PM201-42B 5.1V 3A 30A ±2% 12V 0A 8A ±4% -12V 0A 4A ±4% 12V 0A 4A ±4% 100W/200W PM201-44B 5.1V 3A 30A ±2% 12V 0A 8A ±4% -15V 0A 4A ±4% 15V 0A 4A ±4% 100W/200W PM201-45B 5.1V 3A 30A ±2% 12V 0A 8A ±4% -12V 0A 4A ±4% 24V 0A 4A ±4% 100W/200W PM201-40-3B 3.3V 3A 30A ±3% 5.1V 0A 8A ±4% -12V 0A 4A ±4% 12V 0A 4A ±4% 87.5W/175W NOTES: 2. Peak output current is 12 A on +12 V, 9 A on +15 V and 6 A on +24 V. 3. Output #4 is floating. It can be connected externally for positive or negative output. 4. 200 watts for “C” version with a cover and fan assembly. 100 watts for “B” version without moving air (maximum current of output #1 & #2 derated to 50%), or 200 watts with 25 CFM forced air provided by user. 5. When the remote Sense facility is not used, +Sense must be connected to +V, and -Sense to return, on P2 connector. 6. All models may be operated at no-load. At no-load, output voltage tolerance increases to ±10%. 7. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output.

© TT Electronics plc General Note All data sheets are subject to change without notice. TT Electronics | Power Partners, Inc 43 Broad Street Suite B206, Hudson, MA 01749, USA. t: +1 (978) 567-9600 ISS.1 22/07/2020 Page: 2 Specifications Safety Standards & EMC Specifications Safety Standard UL ES 60601-1, CSA C22.2 No. 60601-1, File No. E178020, UL 60950-1 File No. E137410 TUV EN60601-1 TUV EN60950-1 EMI Standard EN55011/EN55022 radiated and conducted EMC Performance EN61000-3-2: Harmonic distortion, Class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±15 KV air and ± 8KV contact EN61000-4-3: Radiated immunity, 10V/m EN61000-4-4: Fast transient/burst, ±2KV EN61000-4-5: Surge, ±1 KV diff., ±2 KV com. EN61000-4-6: Conducted immunity, 10Vrms EN61000-4-8: Magnetic field immunity, 30 A/m EN61000-4-11: Voltage dip immunity, 30% reduction for 500ms, and 100% reduction for 10ms *Consult with TT Electronics for information on additional country safety approvals Input Specifications Input Voltage Range 90 to 264VAC Input Frequency Range 47 to 63Hz Input Current 3.2A (rms) @100VAC, 60 Hz and 1.6A (rms) @240VAC, 50 Hz Earth Leakage Current 220μA max. @ 264VAC, 63Hz Touch Current 100μA max. @ 264 VAC, 63Hz Output Specifications Ripple & Noise 2% peak to peak maximum on 3.3 V & 5.1 V and 1% peak to peak maximum on other voltage outputs Overvoltage Protection Provided on output #1 only; set at 112-132% of its nominal output voltage Overcurrent Protection All outputs protected to short circuit conditions Temperature Coefficient All outputs ±0.04%/°C maximum Transient Response Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change Fan Power 12V at 200 mA maximum, except 24V at 200mA maximum for PM201-25B and PM201-27B, and 5V at 380 mA maximum for PM201-40-3B Environmental Specifications Operating Temperature -0°C to +70°C Storage Temperature -40°C to +85°C Relative Humidity 5% to 95% non-condensing Temperature Derating De-rate from 100% at +50°C linearly to 50% at +70°C Cooling 10.8 CFM forced air provided on “C” version; 25 CFM forced air to be provided for “B” version by user. General Specifications Switching Frequency 88-112 KHz Efficiency 70% minimum on all models Hold-up Time 20ms minimum at 110 VAC Line Regulation ±0.5% maximum at full load Inrush Current 20A @ 115 Vac or 40A @ 230 Vac at 25°C cold start Withstand Voltage

5600 VDC from input to output (2 MOPP)

2100 VDC from input to ground (1 MOPP)

700 VDC from output to ground

(To verify AC strength, get correct test method to avoid power supply damage.) MTBF 350,000 hours at full load at 25°C ambient, calculated per MIL-HDBK-217F Interface Signals PFD TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1ms prior to V1 output dropping 5% below its nomi- nal value. This signal also provides a minimum delay of 100 ms after V1 is with- in regulation. Inhibit Requires an external TTL high level signal to inhibit outputs for standard mod- els

© TT Electronics plc General Note All data sheets are subject to change without notice. ISS.1 22/07/2020 Page: 3 TT Electronics | Power Partners, Inc 43 Broad Street Suite B206, Hudson, MA 01749, USA. t: +1 (978) 567-9600 Diagrams

© TT Electronics plc General Note All data sheets are subject to change without notice. ISS.1 22/07/2020 Page: 4 TT Electronics | Power Partners, Inc 43 Broad Street Suite B206, Hudson, MA 01749, USA. t: +1 (978) 567-9600