Sealed Power For Environmental Connections Marine | Wind Power | Lighting | Transportation | Pumps | Ground Support Machine Tool | Industrial Automation | Motor | Solar Power | Harsh Environments
- 2 - | www.andersonpower.com Rugged and Sealed (IP68) Plugs and Receptacles The SPEC Pak® High Power uses rugged and environmentally sealed (IP68) shells to protect APP ® Powerpole® contacts and housings. Customer configured SPEC Pak® High Power Connectors are capable of up to 260 amps and may be used anywhere a rugged and/or waterproof high power, signal and ground interconnect solution is required. The SPEC Pak ® High Power shell accepts 75 to 180 amp Powerpole ® contacts and up to 8 auxiliary contacts. The wide range of Powerpole® housing colors and contact sizes, coupled with the available Powerpole® insert holders, offers the user a wide array of design options. Wire sizes which can accommodate a range from 24 to 3/0 AWG (0.25 to 85.0 mm²). SPEC Pak® High Power is highly configurable with thousands of design options in a single interconnect. For Use with APP® Powerpole® Signal, Power & Ground Contacts & Housings 1 - Chemical & UV Resistant Ruggedized Shells
- Wire to Wire Configurations
- Wire to Panel Configurations 2 - Stainless Steel Latches (securing plug to receptacle) 3 - IP68 Interfacial Sealing O-Ring 4 - Auxiliary Contacts (up to 8) 5 - Powerpole ® Insert Holders (user configurable)
- H02 Arrangement - up to two PP180 & 8 Auxiliaries
- H03 Arrangement - up to three PP120 & 8 Auxiliaries
- H06 Arrangement - up to six PP75 & 8 Auxiliaries 6 - Power Contacts (up to 260 amps with 3/0 AWG) 7- Color Coded Powerpole® Housings Match Wire Colors 8 - Industry Standard Sealing (IP68) Components
- PG Gland Compatible - Size 36 & 42
- Multi Hole Glands For Use With Discrete Wires
- Single Hole Glands For Use With Jacketed Cable Powerpole® Insert Arrangement5 H02 H03 H06 1 2 4
- 3 - www.andersonpower.com | Specifications High Power SPEC Pak® Shell / Components Electrical UL Voltage Rating (AC/DC) 600 Dielectric Withstanding Voltage (AC) 3000 Operating Temperature (°C ) [1] -40 to 105 (°F ) -40 to 221 Flammability Rating of SPEC Pak® Shells UL94 V-0 UV Rating (equivalent) UL746C F1 Mechanical Shell/Latch Mating Cycles 1,500 Min. Average Connect/Disconnect (lbf) 28 (N) 125 IP Rating IP68 UL50E Sealing Requirement Pass Crush Test per EIA-364-40B Pass Drop Test per UL50E Pass Material SPEC Pak ® - Receptacle, Plug & Holders PBT Latch Stainless Steel Latch Retainer Stainless Steel Holder Mount Hardware Nickel Plated Steel Powerpole® Contacts PP180 PP120 PP75 PowerMod® UL Current Rating (Amperes) [2] 260 190 70 5 CSA (30C Rise) (Amperes) [2] 140 100 40 5 Voltage Rating (AC/DC) 600 600 600 600 Contact Barrel Wire Size (AWG) 3/0 to 6 1/0 to 6 6 to 12 12 to 24 Average Contact Resistance (milliohm) 0.10 0.14 0.20 3.00 Contact Retention Force (lbf) 170 100 50 8 (N) 756 445 222 36 Operating Temperature (°C) [1] -20 to 105 -20 to 105 -20 to 105 -20 to 105 (°F) -4 to 221 -4 to 221 -4 to 221 -4 to 221 Flammability Rating UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0 Contact Materials Copper Copper Copper Copper Alloy Contact Plating Silver Silver Silver Gold over Nickel Mechanical Mating Cycles - no load [3] 10,000 10,000 10,000 10,000 Average Connect/Disconnect (lbf) 20 8 5 (Low Detent) 10 oz. (3N) Average 7 (High Detent) Material Powerpole® Housing Material Polycarbonate Polycarbonate Polycarbonate PBT NOTE: [1] -40° to 105° C (-40° to 221° F) can be achieved by using APP Chemical Resistant Powerpole® housing. Contact factory for more information. [2] Based on Panel Mount Receptacle to Plug configuration. [3] Based on silver plated contacts. For other industry tests and/or agency approvals, contact customer service. Mated pair High Power Plug To Inline Receptacle Inline Receptacle Latch Plug PG Gland
- 4 - | www.andersonpower.com Product Selection Guide SPEC Pak ® High Power Series is a highly configurable environmentally sealed connector, that can be purchased as components in bulk for volume production, or pre-packaged as a kit. For your convenience, follow the steps below to determine the component or kit part number. | KIT PART NUMBER GUIDE (FOR KITTED CONNECTOR PURCHASE) | | COMPONENT PART NUMBER GUIDE (FOR COMPONENT BULK PURCHASE) | Step 1: Select Shell * Select shell kit for use with PG36 _____ or PG42 _____ from page 6. Step 1 - (see page 6) Plug Inline Receptacle Panel Mount Receptacle Step 2: Select Wire Protection * Define: Number of Wires Wire OD Wires * Select wire protection that will accommodate the number of wires and outer diameter (OD) of the wire used in your application, from page 7. * Wire protection is required for use with Inline Receptacles and Plugs to obtain IP68 seal. 095 = 095mm Panel Mount Receptacle Shell A95 = 095mm Inline Receptacle or Plug Shell, PG 36 B95 = 095mm Inline Receptacle or Plug Shell, PG 42 H02, PP180, 2 Pole H03, PP120, 3 Pole H06, PP75, 6 Pole 1 = Inline Receptacle 2 = Panel Mount Receptacle 6 = Plug 9 = Receptacle Cover 9P = Plug Cover List Kit Part Number Here: SPEC Pak® Series Shell Color Shell Style Shell Size Insert Arrangement (Select One) Dash (Select One) (Select One) S K - List Component Part Numbers Here:
- 5 - www.andersonpower.com | Step 3: Select Housing Arrangement * Define: Number of Number of Wires Auxiliaries Housing Arrangement * Select housing arrangement colors appropriate for your AC or DC application, from page 8, 9 or 10. Step 4: Select Contacts * Define: Number of Wire Gauge Wire Gauge Contacts Amps (continuous): ____ Max amps at ____ volts * Select power and/or auxiliary contacts appropriate for your wire size (AWG or mm²), from page 8, 9 or 10. Step 2 - Wire Protection Step 3 - Select Housing Arrangement (Style) Step 4 - Select Contacts Custom 00 = None PS = Plastic Single Hole PM = Plastic Multi Hole 00 = None “01 to 99 = Various Gland Types From Page 7 Number of Holes Cable Sealing Range (Select Two) Dash (Select One) (Select One) Dash - - Contact the factory Custom Configuration Insert Arrangement 0 = Custom Configuration - A = AC Single Phase H03 B = AC 3 Phase, 3 Wire H06 E = AC 3 Phase, 4 wire H06 F = AC 3 phase, 5 wire H06 G = DC 2 Circuit, 6 wire H06 R = DC 1 Circuit, 2 Wire H02, H03 Z = All Black H02, H03, H06 Contact Wire Size Insert Code Contact AWG (mm²) Arrangement 80 = 1328G2 3/0 85.0 H02 81 = 1328G1 2/0 67.4 H02 82 = 1382 1/0 53.5 H02 83 = 1347 #1 42.4 H02 84 = 1383 #2 33.6 H02 85 = 1384 #4 21.2 H02 86 = 1348 #6 13.3 H02 With Auxiliary [1] 87 = 1328G2 3/0 85.0 H02 88 = 1328G1 2/0 67.4 H02 89 = 1382 1/0 53.5 H02 90 = 1347 #1 42.4 H02 91 = 1383 #2 33.6 H02 92 = 1384 #4 21.2 H02 93 = 1348 #6 13.3 H02 Contact Wire Size Insert Code Contact AWG (mm²) Arrangement 20 = 1323G2 1/0 53.5 H03 21 = 1323G1 #1 42.4 H03 22 = 1319 #2 33.6 H03 23 = 1319G4 #4 21.2 H03 24 = 1319G6 #6 13.3 H03 With Auxiliary [1] 25 = 1323G2 1/0 53.5 H03 26 = 1323G1 #1 42.4 H03 27 = 1319 #2 33.6 H03 28 = 1319G4 #4 21.2 H03 29 = 1319G6 #6 13.3 H03 Contact Wire Size Code Contact AWG (mm²) Insert 00 = Custom Configuration Arrangement 11 = 5900 #6 13.3 H06 12 = 5952 #8 8.4 H06 13 = 5915 #10/12 5.3/3.3 H06 With Auxiliary [1] 14 = 5900 #6 13.3 H06 15 = 5952 #8 8.4 H06 16 = 5915 #10/12 5.3/3.3 H06 List Component Part Numbers Here: NOTE: [1] Contact code designation #25 to 29 uses 4 each of PM16P12S30 (pins) & 4 each of part number PM16S12S32 (sockets) as signal. Power Contact Pin Auxiliary Contact Socket Auxiliary Contact
- 6 - | www.andersonpower.com Cover Kit Description - Part Numbers - Receptacle SK9-095 Plug SK9P-095 Component Replacement Parts Description - Part Number - #8 x 5/8 screws H1120P41 PP75 Spacer & Key Red, short 1399G23-BK 1399G23 Red, long 1399G21-BK 1399G21 | ORDERING INFORMATION | Step 1: Select Shell (Pick 1 Receptacle Shell Kit & Pick 1 Plug Shell Kit) Panel Mount Receptacle Gasket Panel Mount Receptacle Shell With Latches Powerpole® Holder Set Holder Retaining Screws Holder Retaining Screws Powerpole® Holder Set Inline Receptacle Shell With Latches Powerpole® Holder Set Holder Retaining Screws Plug Shell IP68 Sealing Plug Cover IP68 Sealing Receptacle Cover Lanyard Short Long | ACCESSORIES | Panel Mount Receptacle Shell Kit Description -- Part Numbers -- With 2 pole PP180 holders SK2-095H02 With 3 pole PP180 holders SK2-095H03 With 6 pole PP75 holders SK2-095H06 Inline Receptacle Shell Kit (PG 36) Description -- Part Numbers -- PG 36, with 2 pole PP180 holder SK1-A95H02 PG 36, with 3 pole PP120 holder SK1-A95H03 PG 36, with 6 pole PP75 holder SK1-A95H06 Plug Shell Kit (PG 36) Description -- Part Numbers -- PG 36, with 2 pole PP180 holder SK6-A95H02 PG 36, with 3 pole PP120 holder SK6-A95H03 PG 36, with 6 pole PP75 holder SK6-A95H06 Inline Receptacle Shell Kit (PG 42) Description -- Part Numbers -- PG 42, with 2 pole PP180 holder SK1-B95H02 PG 42, with 3 pole PP120 holder SK1-B95H03 PG 42, with 6 pole PP75 holder SK1-B95H06 Plug Shell Kit (PG 42) Description -- Part Numbers -- PG 42, with 2 pole PP180 holder SK6-B95H02 PG 42, with 3 pole PP120 holder SK6-B95H03 PG 42, with 6 pole PP75 holder SK6-B95H06
- 7 - www.andersonpower.com | | SPECIFICATIONS | Mechanical Operating Temp -40°C to 105°C (-40°F to 221°F) IP Rating IP68 UV Rating Equivalent to UL746C F1 Thread Type PG Material Shell Nylon PA 66 (UL94 V-2) Gasket EPDM Color Black Torque Requirements Cable Gland Body to Plug Housing - Hand tighten until snug, tighten additional 1/8 - 1/4 turn with wrench Sealing Nut to Cable - Hand tighten until snug, tighten additional 1/2 - 3/4 turn with wrench NOTE: 1. Other PG Gland configurations and specifications are available, please contact the factory. 2. Only UL listed cable glands are UL recognized components when used with SPEC Pak® connector(s). 3. Shading indicates stock item. | STRAIGHT PLASTIC MULTI-HOLE TYPE - STD PACK 10 / NOT UL LISTED | Lock Nut Washer Body Seal Claw Sealing Nut | STRAIGHT PLASTIC SHORT THREAD TYPE - STD PACK 10 / UL LISTED | C1Lock Nut Washer Body Seal Sealing Nut Cable Range PG Thread Panel Thread Wrench Wrench Wire Protection Number Wire Outer Gland O.D. C1 Mounting Length Size Lock Size Sealing Designation of Holes Dia. mm (in) Size mm (in) Hole mm (in) C2 mm (in) Nut (mm) Nut (mm) (4 Characters) -- Part Numbers -- Cable Range PG Thread Panel Thread Wrench Wrench Wire Protection Number Wire Outer Gland O.D. C1 Mounting Length Size Lock Size Sealing Designation of Holes Dia. mm (in) Size mm (in) Hole mm (in) C2 mm (in) Nut (mm) Nut (mm) (4 Characters) -- Part Numbers --
- 8 - | www.andersonpower.com H02 Housing Arrangement Configured with up to 2 PP180 Contacts - Up to 260 Amps - Standard & Custom Configuration Options | HOUSING ARRANGEMENTS | | POWERPOLE® INSERT HOLDER | | POWERPOLE® CONTACTS & HOUSINGS FOR H02 INSERT ARRANGEMENT | NOTE: 1. For custom configuration, contact the factory. 2. Arrangement represents front view of the receptacle. H02 Custom Configuration R Z 1381G1 1381G3 1381G1 1381G1 DC 1 Circuit, 2 Wire All Black PP180 Contacts Mating Contact Code 3/0 85 Low - - 1328G2-BK 1328G2 80 2/0 67.4 Low - 1328G1-BK - 1328G1 81 1/0 53.5 High 1382-BK - - 1382 82 1 42.4 High 1347-BK - - 1347 83 2 33.6 High 1383-BK - - 1383 84 4 21.1 High 1384-BK - - 1384 85 6 13.3 High 1348-BK - - 1348 86 PP180 Housings Red 1381G3-BK 1381G3 Green 1381G4-BK 1381G4 Black 1381G1-BK 1381G1 White 1381G2-BK 1381G2 Blue 1381-BK 1381 Auxiliary Contacts (PowerMod® series) Contact Code Standard Length 7.7mm Pin 24 to 20 0.50 to 0.75 PM16P2024S30 PM16P2024S30-50 - Pin 20 to 18 0.75 to 1.00 PM16P1620S30 PM16P1620S30-50 - Pin 16 to 14 1.00 to 1.5 PM16P1416S30 PM16P1416S30-50 - Pin 12 2.50 PM16P12S30 PM16P12S30-50 87 thru 93 Pre-Mate 9.3mm Pin 24 to 20 0.50 to 0.75 PM16P2024A30 PM16P2024A30-50 - Pin 20 to 18 0.75 to 1.00 PM16P1620A30 PM16P1620A30-50 - Pin 16 to 14 1.00 to 1.5 PM16P1416A30 PM16P1416A30-50 - Pin 12 2.50 PM16P12A30 PM16P12A30-50 - Post-Mate 6.4mm Pin 24 to 20 0.50 to 0.75 PM16P2024C30 PM16P2024C30-50 - Pin 20 to 18 0.75 to 1.00 PM16P1620C30 PM16P1620C30-50 - Pin 16 to 14 1.00 to 1.5 PM16P1416C30 PM16P1416C30-50 - Pin 12 2.50 PM16P12C30 PM16P12C30-50 - Socket 24 to 20 0.25 to 0.50 PM16S2024S32 PM16S2024S32-50 - Socket 20 to 16 0.50 to 1.30 PM16S1620S32 PM16S1620S32-50 - Socket 16 to 14 1.30 to 2.10 PM16S1416S32 PM16S1416S32-50 - Socket 12 2.5 PM16S12S32 PM16S12S32-50 87 thru 93 NOTE: 1. Contact code designation #87 to 93 is 4 each of PM16P12S30 (pins) & 4 each of part number PM16S12S32 (sockets) as signal. 2. See Powerpole ® & Multipole Power Connectors Catalog for additional contacts and/or housings options. 3. Application tooling information is available on page 11.
- 9 - www.andersonpower.com | Auxiliary Contacts (PowerMod® series) Contact Code Standard Length 7.7mm Pin 24 to 20 0.50 to 0.75 PM16P2024S30 PM16P2024S30-50 - Pin 20 to 18 0.75 to 1.00 PM16P1620S30 PM16P1620S30-50 - Pin 16 to 14 1.00 to 1.5 PM16P1416S30 PM16P1416S30-50 - Pin 12 2.50 PM16P12S30 PM16P12S30-50 25 thru 29 Pre-Mate 9.3mm Pin 24 to 20 0.50 to 0.75 PM16P2024A30 PM16P2024A30-50 - Pin 20 to 18 0.75 to 1.00 PM16P1620A30 PM16P1620A30-50 - Pin 16 to 14 1.00 to 1.5 PM16P1416A30 PM16P1416A30-50 - Pin 12 2.50 PM16P12A30 PM16P12A30-50 - Post-Mate 6.4mm Pin 24 to 20 0.50 to 0.75 PM16P2024C30 PM16P2024C30-50 - Pin 20 to 18 0.75 to 1.00 PM16P1620C30 PM16P1620C30-5 - Pin 16 to 14 1.00 to 1.5 PM16P1416C30 PM16P1416C30-50 - Pin 12 2.50 PM16P12C30 PM16P12C30-50 - Socket 24 to 20 0.25 to 0.50 PM16S2024S32 PM16S2024S32-50 - Socket 20 to 16 0.50 to 1.30 PM16S1620S32 PM16S1620S32-50 - Socket 16 to 14 1.30 to 2.10 PM16S1416S32 PM16S1416S32-50 - Socket 12 2.5 PM16S12S32 PM16S12S32-50 25 thru 29 H03 Housing Arrangement Configured with up to 3 PP120 Contacts - Up to 190 Amps - Standard & Custom Configuration Options | HOUSING ARRANGEMENTS | | POWERPOLE® INSERT HOLDER | Custom Configuration A R 1321G1 1321G2 1321G4 1321G1 1321G3 AC Single Phase DC 1 Circuit, 2 Wire All Black Z 1321G1 1321G1 1321G1 E H03 | POWERPOLE® CONTACTS & HOUSINGS FOR H03 INSERT ARRANGEMENT | PP120 Housings Red 1321G3-BK 1321G3 Green 1321G4-BK 1321G4 Black 1321G1-BK 1321G1 White 1321G2-BK 1321G2 Blue 1321-BK 1321 PP120 Silver Plated Wire Contacts Mating Contact Code 1/0 53.5 Low 1323G2-BK - 1323G2 20 1 42.4 Low 1323G1-BK - 1323G1 21 2 33.6 High - 1319-BK 1319 22 4 21.1 High - 1319G4-BK 1319G4 23 6 13.3 Low - 6811G4-BK 6811G4 24 NOTE: 1. E = Empty 2. For custom configuration, contact the factory. 3. Arrangement represents front view of the receptacle. NOTE: 1. Contact code designation #25 to 29 uses 4 each of PM16P12S30 (pins) & 4 each of part number PM16S12S32 (sockets) as signal. 2. See Powerpole ® & Multipole Power Connectors Catalog for additional contacts and/or housings options. 3. Application tooling information is available on page 11.
- 10 - | www.andersonpower.com H06 Housing Arrangement Configured with up to 6 PP75 Contacts - Up to 75 Amps - Standard & Custom Configuration Options | HOUSING ARRANGEMENTS | | POWERPOLE® INSERT HOLDER | Custom Configuration B E 5916G4 5916G5 5916G6E AC 3 Phase, 3 Wire AC 3 Phase, 4 Wire AC3 Phase, 5 Wire DC 2 Circuit, 6 Wire 5916G7 E 5916G4 5916 5916G75916G6 5916G5 E 5916G4 5916G5 5916G65916 5916G7 5916 5916G7 5916G7 5916G7 5916G45916G4 5916G4 F G H06 | POWERPOLE® CONTACTS & HOUSINGS FOR H06 INSERT ARRANGEMENT | PP75 Standard Housings Red 5916G7-BK 5916G7 Green 5916G6-BK 5916G6 Black 5916G4-BK 5916G4 White 5916G5-BK 5916G5 Blue 5916-BK 5916 PP75 Contacts Mating Loose Piece Contact Code AWG mm² Force -- Part Numbers -- Designation 6 13.3 High 5900-BK 5900 11 8 8.4 High 5952-BK 5952 12 12 to 10 3.3 to 5.3 High 5915-BK 5915 13 NOTE: 1. E = Empty 2. For custom configuration, contact the factory. 3. Arrangement represents front view of the receptacle. Auxiliary Contacts (PowerMod® series) Contact Code Standard Length 7.7mm Pin 24 to 20 0.50 to 0.75 PM16P2024S30 PM16P2024S30-50 - Pin 20 to 18 0.75 to 1.00 PM16P1620S30 PM16P1620S30-50 - Pin 16 to 14 1.00 to 1.5 PM16P1416S30 PM16P1416S30-50 - Pin 12 2.50 PM16P12S30 PM16P12S30-50 14 thru 16 Pre-Mate 9.3mm Pin 24 to 20 0.50 to 0.75 PM16P2024A30 PM16P2024A30-50 - Pin 20 to 18 0.75 to 1.00 PM16P1620A30 PM16P1620A30-50 - Pin 16 to 14 1.00 to 1.5 PM16P1416A30 PM16P1416A30-50 - Pin 12 2.50 PM16P12A30 PM16P12A30-50 - Post-Mate 6.4mm Pin 24 to 20 0.50 to 0.75 PM16P2024C30 PM16P2024C30-50 - Pin 20 to 18 0.75 to 1.00 PM16P1620C30 PM16P1620C30-50 - Pin 16 to 14 1.00 to 1.5 PM16P1416C30 PM16P1416C30-50 - Pin 12 2.50 PM16P12C30 PM16P12C30-50 - Socket 24 to 20 0.25 to 0.50 PM16S2024S32 PM16S2024S32-50 - Socket 20 to 16 0.50 to 1.30 PM16S1620S32 PM16S1620S32-50 - Socket 16 to 14 1.30 to 2.10 PM16S1416S32 PM16S1416S32-50 - Socket 12 2.5 PM16S12S32 PM16S12S32-50 14 thru 16 NOTE: 1. Contact code designation #14 to 16 uses 4 each of PM16P12S30 (pins) & 4 each of part number PM16S12S32 (sockets) as signal. 2. See Powerpole® & Multipole Power Connectors Catalog for additional contacts and/or housings options. 3. Application tooling information is available on page 11. Z 5916G4 5916G4 All Black 5916G4 5916G4 5916G4 5916G4
- 11 - www.andersonpower.com | AWG mm² Loose Piece Part Numbers Tin Plating Silver Plating Hand Tool Die Locator Number of Crimps Tin Plating Silver Plating ATS Applicator ATS Press Air Feed Kit * Wire Size or Pneumatic Bench Tool + + Loose Piece Contact Crimp Tool Reeled Part Numbers Reeled Contact Crimp Tools 1307 5900 #8 8.4 5952 5953 5915 1/0 53.5 1323G2 #1 42.4 1323G1 #2 33.6 1319 #4 21.2 1319G4 #6 13.3 1319G6 3/0 85 1328G2 1303G12 2/0 53.5 1328G1 1303G13 #1 42.4 1347 1387G2 1303G13 1304G32 Double 1387G1 1388G3 1389G3 Single 1387G2 1303G13 1304G32 Double #6 13.3 1348 1387G1 1388G4 1389G3 Single * All ATS applicators for APP® contacts are air feed style, (except 1385870) and require the press to have an air feed kit installed. Double Single Single1387G1 1388G6 1389G6 #6 13.3 1309G4 #10 / 12 5.3 / 3.3 N/A N/A 1368 1387G1 1387G2 1388G4 1389G4 1388G3 1304G32 1385523-1 1385522-1265G6 1/0 53.5 1382 1387G1 N/A 1368 1388G3 1389G3 265G5 N/A Single 1388G7 33.6 1383 #4 21.1 1384 N/AN/A N/A 2-565435-2 692655-1 1725900-2 or [3-54500-1] 1424266-1 or [354578-1] N/A PP180 PP120 PP75 NOTE: See website for the most current information. Tooling
1309 PM1000G1 TM0001
1368 TP0001
- TP0001 and TM0001 tools require locators to properly position contacts. TP0001* N/A PM1000G1#12 / 24 2.5 / .25 TL0001 TL0002 Single AWG mm² Contacts Pneumatic Bench Tool + Die + Locator Number of Crimps or Hand Tool PowerMod Auxiliary Contacts Loose Piece Part Numbers Wire Size Loose Piece Contact Crimp Tool NOTE: See website for the most current information. TM0001*
HEADQUARTERS: Anderson Power Products®, 13 Pratts Junction Road, Sterling, MA 01564-2305 USA T:978-422-3600 F:978-422-0128 EUROPE: Anderson Power Products® Ltd., Unit 3, Europa Court, Europa Boulevard, Westbrook, Warrington, Cheshire, WA5 7TN United Kingdom T: +44 (0) 1925 428390 F: +44 (0) 1925 520203 ASIA / PACIFIC: IDEAL Anderson Asia Pacific Ltd., Unit 922-928 Topsail Plaza, 11 On Sum Street, Shatin N.T., Hong Kong T:+(852) 2636 0836 F:+(852) 2635 9036 CHINA: IDEAL Anderson Technologies (Shenzhen) Ltd., Block A8 Tantou Western Industrial Park, Songgang Baoan District, Shenzhen, PR. China 518105 T: +(86) 755 2768 2118 F: +(86) 755 2768 2218 www.andersonpower.com | INLINE RECEPTACLE | | PANEL MOUNT RECEPTACLE | | PLUG | | MATED SIDE VIEW | | RECEPTACLE COVER | | PLUG COVER | Dimensions [ 155.2 ] 6.11 [ 127.0 ] 5.00 Shell with PG 36 200 7.9 Shell with PG 42 208 8.2 APPROXIMATE OVERALL LENGTH W/ GLAND X MM IN[ 6.11 ] 155.2 X [ 3.57 ] 90.7 [ 0.55 ] 14.0 Latch Range CL CL [ 0.22 ] Ø 5.6 TYP (8) [ 2.94 ] 74.7 [ 3.84 ] 97.5 [ 0.71 ] 18.0 [ 3.30 ] 83.8 [ 1.23 ] R31.2 TYP (2) [ 1.50 ] 38.1 [ 3.50 ] 88.8 [ 5.0 ] 127.0 [ 1.80 ] 45.7 [ 2.94 ] 74.6 [ 1.7 ] 43.1 MAX PP180 [ 1.80 ] 45.7 [ 4.49 ] 114.0 [ 0.55 ] 14.0 Latch Range [ 5.85 ] 148.6 [ 3.95 ] 100.3 [ 5.85 ] 148.6 APPROXIMATE OVERALL LENGTH W/ GLAND X MM IN 193 7.6 201 7.9X [ 3.24 ] 82.3 Shell with PG 36 Shell with PG 42 X PLUG TO PANEL MOUNT RECEPTACLE X Shell with PG 36 Shell with PG 36 MM IN 114.0 4.7 200.7 7.90 114.0 4.7 207.3 8.16 MM IN PANEL [ 4.47 ] 114.0 [ 1.7 ] 43.1 MAX PP180 X [ 3.57 ] 90.7 PLUG TO INLINE RECEPTACLE X Shell with PG 36 Shell with PG 36 MM IN 90.7 3.57 354.1 13.94 MM IN 90.7 3.57 370.3 14.58 [ 3.65 ] 92.7 [ 4.80 ] 121.88 [ 2.25 ] 57.15 [ 3.96 ] 100.7 [ 1.09 ] 27.6 REF [ 3.015 ] 76.58 [ 2.25 ] 57.15 [ 1.09 ] 27.6 REF [ 0.150 ] 3.81 [ 4.798 ] 121.88 [ 1.003 ] 24.48 All Data Subject To Change Without Notice “SPEC Pak, PowerMod, Powerpole, A, APP & Anderson Power Products are registered trademarks of Anderson Power Products”. 15411 DS-HPSPAK REV 01 Top View Side View Panel Cutout Top View Side View Top View Side View Plug to Panel Mount receptacle Plug to Inline Receptacle Front View Side View Front View Side View