PM042OX1 AZDISPLAYS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 28

Technical content

The information contained herein is the exclusive property of Prime View In ternational Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part w ithout prior written permission of Prime View International Co., Ltd. Page:1 Version : 0.1 TECHNICAL SPECIFICATION MODEL NO. : PM042OX1 Customer’s Confirmation Customer By PVI’s Confirmation Confirmed By Prepared By Date: Oct 08, 2004 This technical specification is subject to change without notice. Please return 1 copy with your signature on this page for approval. FOR MORE INFORMATION: AZ DISPLAYS, INC.

75 COLUMBIA, ALISO VIEJO, CA, 92656

Http://www.AZDISPLAYS.com

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:2 TECHNICAL SPECIFICATION

CONTENTS

NO. ITEM PAGE - Cover 1 - Contents 2

1 Application 3

2 Features 3

3 Mechanical Specifications 3

4 Mechanical Drawing of TFT-LCD module 4

5 Input / Output Terminals 6

6 Absolute Maximum Ratings 12

7 Electrical Characteristics 12

8 Pixel Arrangement 13

9 Display Color and Gray Scale Reference 14

10 Block Diagram 15

11 Interface Timing 16

12 Power On Sequence 21

13 Optical Characteristics 21

14 Handling Cautions 25

15 Reliability Test 26

16 Indication of Lot Number Label 26

17 Packing Diagram 27

  • Revision History 28

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:3 1.Application This data sheet applies to a color TFT LCD module, PM042OX1. PM042OX1 module applies to Car Audio, which requires high quality flat panel display. If you must use in severe reliability environment, please don’t extend over PVI’s reliability test conditions. If you use PM042OX1, Prime View advises your systems use PVI’s timing controller IC (PVI-2002A) which will generate proper timing signals to control PM042OX1. 2. Features . Resolution: 320 * RGB * 96 . Amorphous silicon TFT LCD panel with back-light unit . Pixel in stripe configuration . Thin and light weight . Display Colors:262,144 colors . Optimum Viewing Direction:6 o’clock . TTL interface . Wide viewing angle 3.Mechanical Specifications Parameter Specifications Unit Screen Size 4.2 (diagonal) inch Display Format 320×(R, G, B)×96 dot Display Colors 262,144 Active Area 103.68(H)×25.10(V) mm Pixel Pitch 0.324(H)×0.261(V) mm Pixel Configuration Stripe Outline Dimension 119.9(W)*38.30(H)*6.6(D) (Typ.) mm Weight TBD g Back-light CCFL, 1 tube Surface treatment Anti-glare and Wide View Film Display mode Normally white

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:4 4.Mechanical Drawing of TFT-LCD Module Outline Drawing : Front View (unit : mm) Patrick Lin Patrick Lin M001-037-01 4.2"SW(FRONT VIEW) CN1 CN2

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:5 Outline Drawing : Rear View (unit : mm) 30 1 (S: 2/1,2PLS) DETAIL "A" Patrick Lin Patrick Lin 4.2"SW(BACK VIEW) M001-037-01 CN1CN2 30 1 30 1

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:6 5.Input / Output Terminals 5-1) TFT-LCD Panel Driving Connector type: ELCO, 6210-30PIN, PIN No 30 pins, pitch=0.5mm CN 1 Pin No. Symbol I/O Function Remark

1 DIO1 I/O Horizontal Start Pulse Signal Input or Output Note 5-1

2 VSS1 I Ground

3 VDD1 I Power Supply

4 CLK I Horizontal Shift Clock

5 VSS1 I Ground

6 R/L I Right / Left selection Note 5-1

7 R0 I Red Data (LSB)

8 R1 I Red Data

9 R2 I Red Data

10 R3 I Red Data

11 R4 I Red Data

12 R5 I Red Data (MSB)

13 VSS1 I Ground

14 G0 I Green Data (LSB)

15 G1 I Green Data

16 G2 I Green Data

17 G3 I Green Data

18 G4 I Green Data

19 G5 I Green Data (MSB)

20 VSS1 I Ground

21 B0 I Blue Data (LSB)

22 B1 I Blue Data

23 B2 I Blue Data

24 B3 I Blue Data

25 B4 I Blue Data

26 B5 I Blue Data (MSB)

27 LD I Load output signal Note 5-2

28 REV I Data invert control Note 5-3

29 POL I Polarity selection Note 5-4

30 DIO2 I/O Horizontal Start Pulse Signal Input or Output Note 5-1

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:7 CN 2 Pin No. Symbol I/O Function Remark

1 VSS2 I Ground

2 V1 I Gamma Voltage 1 Note 5-10

3 V2 I Gamma Voltage 2 Note 5-10

4 V3 I Gamma Voltage 3 Note 5-10

5 V4 I Gamma Voltage 4 Note 5-10

6 V5 I Gamma Voltage 5 Note 5-10

7 V6 I Gamma Voltage 6 Note 5-10

8 V7 I Gamma Voltage 7 Note 5-10

9 VSS2 I Ground

10 V8 I Gamma Voltage 8 Note 5-10

11 V9 I Gamma Voltage 9 Note 5-10

12 V10 I Gamma Voltage 10 Note 5-10

13 V11 I Gamma Voltage 11 Note 5-10

14 V12 I Gamma Voltage 12 Note 5-10

15 V13 I Gamma Voltage 13 Note 5-10

16 V14 I Gamma Voltage 14 Note 5-10

17 VSS2 I Ground

18 VDD2 I Voltage for analog circuit Note 5-10

19 VCOM I Common Voltage

20 XON I NC

21 OE I Output Enable Note 5-5

22 U/D I Up / Down Selection Note 5-6

23 CKV I Vertical Shift Clock Note 5-7

24 STVU I/O Vertical Shift Pulse Signal Input or Output Note 5-6

25 STVD I/O Vertical Shift Pulse Signal Input or Output Note 5-6

26 VGG I Gate On Voltage Note 5-8

27 GND I Ground

28 VCC I Voltage for logic circuit

29 GND I Ground

30 VEE I Gate Off Voltage Note 5-9

Note 5-1: Select left or right shift R/L DIO1 DIO2 Shift

1 Input Hi-Z Left to right

0 Hi-Z Input Right to left

Note 5-2: Latch the polarity of outputs and switch the new data to outputs At the rising edge (CLK), latch the “POL” signal to control the polarity of the outputs. Note 5-3: Control whether the Data R0~G5 are inverted or not. (PVI suggests connecting to GND) When “REV=1”, these data will be inverted. Note 5-4: Polarity selector for dot-inversion control. Available at the rising edge of LD. When POL=1: Even outputs range from V1~V7, and Odd outputs range from V8~V14; When POL=0: Even outputs range from V8~V14, and Odd outputs range from V1~V7.

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:8 Note 5-5: When OE is connected to high “1”, the driver outputs are disabled (Gate output = V EE). Under this condition, the operation of registers will not be affected. Note 5-6: Select up or down shift U/D STVU STVD Shift

1 Hi-Z Input Down to Up

0 Input Hi-Z Up to Down

Note 5-7: Gate driver shift clock Note 5-8: Gate on voltage, V GG=20V. Note 5-9: Gate off voltage, V EE=-10V. Note 5-10: 1) Relationship between input data and output voltage The figure below shows the relationship between the input data and the output voltage with the polarity. The range of V1~V7 is for positive polarity, and V8~V14 for negative polarity. Please refer to the following pages to get the related resister values and voltage calculation method. Positive polarity Negative polarity Gamma correction diagram Vout VDD2 V10 V11 V12 V13 V14 Vcom Vss2 00H 08H 10H 18H 20H 28H 30H 38H 3FH Input Data VSS2+0.1V.

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:9 2) Output voltage and input data Output Voltage to Panel V.S. Input Data Data Positive polarity Output Voltage Negative polarity Output Voltage 00H V1 V14 10H V3 V12 15H V4+(V3-V4) × 12 / 22 V12+(V11-V12) × 10 / 22

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:10 Output Voltage to Panel V.S. Input Data (continued) Data Positive polarity Output Voltage Negative polarity Output Voltage 20H V4 V11 30H V5 V10 3FH V7 V8

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:11 3) Typical Application Circuit (When V DD2 = +9.5V)

0 OHM

1.2K OHM OPEN OPEN 10K OHM 787 1% OHM 10K OHM OPEN OPEN 4.7K OHM 51K OHM OPEN 5-2) Backlight driving Connector type: JST BHSR-02VS-1, PIN No 2 pins, pitch=3.5mm Pin No Symbol Description Remark

1 VL1 Input terminal (Hi voltage side) Wire color : Pink

2 VL2 Input terminal (Low voltage side)

Wire color : White Note 5-11 Note 5-11: Low voltage side of backlight inverter connects with ground of inverter circuits.

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:12 6.Absolute Maximum Ratings: V SS1=VSS2=GND=0V, Ta=25℃ Parameters Symbol MIN. MAX. Unit Remark VDD1 V VCC -0.3 5.0 V VDD2 -0.5 12.0 V VGG -0.3 40.0 V VGG-VEE - 40 V Supply Voltage VEE -20 0.3 V Digital Input V IN -0.5 V CC+0.5 V Backlight Driving Voltage V L - 2000 V Backlight Driving Frequency F L 0 100 KHz Storage Temperature T ST -30 80 ℃ Operating Temperature T OP -20 80 ℃ 7.Electrical Characteristics 7-1) Recommended Operating Conditions: VSS1=VSS2=GND=0V, Ta=25℃ Item Symbol Min. Typ. Max. Unit Remark VDD1 3.0 3.3 3.6 V Supply Voltage for Source Driver VDD2 9 9.5 10 V VGG - 20 - V VEE - -10 - V Supply Voltage for Gate Driver VCC 3.0 3.3 3.6 V VIH 0.8V DD1 - V DD1 V Digital Input Voltage VIL 0 - 0.2V DD1 V 7-2) Recommended Driving Condition for Back Light T a = 2 5 ℃ Parameter Symbol Min. Typ. Max. Unit Remark Lamp Voltage V L TBD TBD TBD V I L=6mA Lamp Current I L TBD TBD TBD mA Note 7-1 Lamp Frequency P L TBD TBD TBD KHz Note 7-2 Starting Voltage (25℃) (Reference Value) Vs - - TBD Vrms Note 7-3 Starting Voltage (0℃) (Reference Value) Vs - - TBD Vrms Note 7-3 Note 7-1: In order to have proper operation of the B/L, no matter what kind of inverters, the output lamp current must be between Min. and Max. values to avoid the abnormal display image caused by B/L. Note 7-2: The waveform of lamp driving voltage should be as close to a perfect sine wave as possible. Note 7-3: This value is not the output voltage of inverter. The voltage of inverter must be larger than the starting voltage.

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:13 7-3) Power Consumption Parameter Symbol Min. Typ. Max. Unit Remark Supply Current for Gate Driver (Hi level) I GG V GH=+20V TBD TBD mA Supply Current for Gate Driver (Low level) I EE V EE=-10V TBD TBD mA Supply Current for Source Driver (Digital) I DD1 V DD1=+3.3V TBD TBD mA Supply Current for Source Driver (Analog) I DD2 V DD2=+9.5V TBD TBD mA Supply Current for Gate Driver (Digital) I CC V CC=+3.3V TBD TBD mA LCD Panel Power Consumption TBD TBD mW Note 7-4 Back Light Lamp Power Consumption TBD TBD W Note 7-5 Note 7-4: The power consumption for back light is not included. Note 7-5: Back light lamp power consumption is calculated by I L×VL. 8. Pixel Arrangement The LCD module pixel arrangement is stripe configuration. R G B R G B R G B R G B R G B R G B R G B R G B R G B R G B R G B R G B R G B R G B rd Line 2 nd Line st Line 96 th Line 95 th Line 94 th Line R G B R G B R G B R G B 1 st Pixel 320 th Pixel

1 Pixel = R G B

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:14 9. Display Color and Gray Scale Reference Input Color Data Color Red Green Blue R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0 Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red (63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Green (63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 Basic Blue (63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 Colors Cyan 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 Magenta 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1 Y e l l o w 1 1 111111111100 0 0 0 0 White 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Red (00) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red (01) 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Red (02) 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 D a r k e r Brighter Red (61) 1 1 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Red (62) 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Red (63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Green (00) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Green (01) 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Green (02) 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 D a r k e r Brighter Green (61) 0 0 0 0 0 0 1 1 1 1 0 1 0 0 0 0 0 0 Green (62) 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0 Green (63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 Blue (00) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Blue (01) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 Blue (02) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 D a r k e r Brighter Blue (61) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 1 Blue (62) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 Blue (63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:15 10. Block Diagram 10-1) TFT-module Block Diagram User connector 30 pin Timing Controller (PVI-2002A) DC-DC Converter Gamma Generator Vcom Generator FPC Source Driver IC Gate Driver IC 4.2" OA TFT-LCD Panel SYSTEM Video Control VDD1 VDD2 Gamma Vcom VGG / VEE If you use PD042OX1, you can apply PVI-2002A(Timing controller) which will gernerate timing signals to support PD042OX1.

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:16 11. Interface Timing 11.1) Timing Parameters CC=VDD1=3.3V, VDD2=9.5V, GND=VSS1=VSS2=0V, Ta=25℃) Parameter Symbol Min. Typ. Max. Unit CLK Frequency Fclk - 2.5 - MHz CLV1 Period Tcph - 0.4 - us CLK Pulse Width Tcw 8 - - ns Data Set-up Time Tsu 4 - - ns Data Hold Time Thd 2 - - ns Propagation Delay of DIO2/1 Tphl 6 10 15 ns Time That The Last Data to LD Tld 1 - - Tcph Pulse width of LD Twld 2 - - Tcph Time That LD to DIO1/2 Tlds 5 - - Tcph POL Set-up Time Tpsu 6 - - ns POL Hold Time Tphd 6 - - ns OE Pulse Width T OEV 1 - - µs CKV Pulse Width T CKV 2.5 - - µs STV Set-up Time T SUV 700 - - ns STV Hold Time T HDV 700 - - ns Horizontal Display Period T HDP - 320 - Tcph Horizontal Period Timing Range T HP - 400 - Tcph Horizontal Lines Per Field T V 100 104 130 T HP Vertical Display Timing Range T DV - 96 - T HP

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:17 11.2) Timing Diagram Tcph CLK DIO1/2 (Input) Data REV DIO1/2 (Output) 70% 70% 70% 70% 70% 70% 30% 30% Tcw TcwTsu Thd Tsu Thd First data Second data 1 2 319 320 Last data Tphl Tphl 70% 70% 70% 30% Fig. 11-1 Operation Mode

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:18 Last 70% Thd Twld Tlds 70% 70% 70% CLK LD DIO 1/2 (Input) 70% 30% 70% 30% 30% 70% 70% 70% 70% Tpsu Tphd Tpsu TpsuTphd Tphd High-z High-z High-z Positive Negative LD POL Odd outputs Even outputs Fig. 11-2 Horizontal timing

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:19 STVU/STVD 50% 50% TSUV THDV TCKV CKV OE TOEV Fig. 11-3 Vertical shift clock timing

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:20 STVU/STVD POL(Odd Field) POL(Even Field) (VSY) (HSY) THDP THP Fig. 11-4 Vertical timing

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:21 12. Power On Sequence 1. 10ms ≦T1<T2 2. 0ms <T3≦T4≦10ms 13. Optical Characteristics 13-1) Specification: Ta=25℃ Parameter Symbol Condition MIN. TYP. MAX. Unit Remarks Horizontal θ TBD TBD - deg Note 13-1 θ(to 12 o’clock) TBD TBD - deg Viewing Angle Vertical θ(to 6 o’clock) CR>10 TBD TBD - deg Contrast Ratio CR At optimized viewing angle 200 400 - - Note 13-2 Rise Tr - 15 30 ms Response time Fall Tf θ=0° - 25 50 ms Note 13-3 Brightness θ=0°/φ=0 TBD TBD - cd/㎡ Note 13-4 Luminance Uniformity U TBD TBD - % Note 13-5 x TBD TBD TBD - White Chromaticity y TBD TBD TBD - Cross Talk θ=0° - - 3.5 % Note 13-6 VSS(0V) VGG ONOFF OFF VDD1,VCC VEE Logic signal RGB-Video signal VDD2

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:22 Note 13-1: The definitions of viewing angles are as follow 6o ’ c l o c k 9o ’ c l o c k 3o ’ c l o c k 12 o’clock θ φ Lamp connector Note 13-2: The definition of contrast ratio CR Luminance at gray level 63 Luminance at gray level 0= Note 13-3: Definition of Response Time T r and Tf: 100% 90% 10% White White Brightness Black Tr Tf

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:23 Note 13-4: All optical measurements shall be performed after backlight being turned-on for 30 mins. The optical characteristics shall be measured in dark room (ambient illumination on panel surface less than 1 Lux). The measuring configuration shows as following figure. Note 13-5: The uniformity of LCD is defined as The Minimum Brightness of the 9 testing Points U = The Maximum Brightness of the 9 testing Points Luminance meter: BM-5A or BM-7 fast (TOPCON) Measurement distance: 500 mm +/- 50 mm Ambient illumination: < 1 Lux Measuring direction: Perpendicular to the surface of module The test pattern is white (Gray Level 63). 123 6 5 4 789 Photometer (TOPCON BM-5A or BM-7 fast) 500 mm +/- 50 mm TFT-LCD module DC/AC Inverter Optical characteristics measuring configuration Field = 2°

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:24 YA-YB Note 13-6: Cross Talk (CTK) = YA ×100% YA: Brightness of Pattern A YB: Brightness of Pattern B Luminance meter: BM-5A or BM-7 fast (TOPCON) Measurement distance: 500 mm +/- 50 mm Ambient illumination: < 1 Lux Measuring direction: Perpendicular to the surface of module Pattern A (Gray Level 31) Pattern B (Gray Level 31, except the black box in the center ) : Measuring Point (A and B are at the same point.) YA YB 1/3 1/3 1/3 Black (Gray Level 0) Note 13-7: Topcon BM-5A or BM-7 fast luminance meter 2° field of view is used in the testing (after 30 minutes’ B/L power-on). The typical luminance value is measured at lamp current TBD mA.

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:25 14. Handling Cautions 14-1) Mounting of module a) Please power off the module when you connect the input/output connector. b) Please connect the ground pattern of the inverter circuit surely. If the connection is not perfect, some following problems may happen possibly. 1.The noise from the backlight unit will increase. 2.The output from inverter circuit will be unstable. 3.In some cases a part of module will heat. c) Polarizer which is made of soft material and susceptible to flaw must be handled carefully. d) Protective film (Laminator) is applied on surface to protect it against scratches and dirts. It is recommended to peel off the laminator before use and taking c a r e o f s t a t i c e l e c t r i c i t y . 14-2) Precautions in mounting a) When metal part of the TFT-LCD module (shielding lid and rear case) is soiled, wipe it with soft dry cloth. b) Wipe off water drops or finger grease immediately. Long contact with water may cause discoloration or spots. c) TFT-LCD module uses glass which breaks or cracks easily if dropped or bumped on hard surface. Please handle with care. d) Since CMOS LSI is used in the module. So take care of static electricity and earth yourself when handling. 14-3) Adjusting module a) Adjusting volumes on the rear face of the module have been set optimally before shipment. b) Therefore, do not change any adjusted values. If adjusted values are changed, the specifications described may not be satisfied. 14-4) Others a) Do not expose the module to direct sunlight or intensive ultraviolet rays for many hours. b) Store the module at a room temperature place. c) The voltage of beginning electric discharge may over the normal voltage because of leakage current from approach conductor by to draw lump read lead line around. d) If LCD panel breaks, it is possibly that the liquid crystal escapes from the panel. Avoid putting it into eyes or mouth. When liquid crystal sticks on hands, clothes or feet. Wash it out immediately with soap. e) Observe all other precautionary requirements in handling general electronic components. f) Please adjust the voltage of common electrode as material of attachment by 1 module. 14-5) Polarizer mark The polarizer mark is to describe the direction of wide view angle film how to match up with the rubbing direction.

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:26 15. Reliability Test No Test Item Test Condition Remark

1 High Temperature Storage Test Ta = +80℃, 240 hrs

2 Low Temperature Storage Test Ta = -30℃, 240 hrs

3 High Temperature Operation Test Ta = +80℃, 240 hrs

4 Low Temperature Operation Test Ta = -20℃, 240 hrs

High Temperature & High Humidity Operation Test Ta = +60℃, 90%RH, 240 hrs (No Condensation) Thermal Cycling Test (non-operating) 0℃Æ+60℃, 50 Cycles 1Hr 1Hr Vibration Test (non-operating) Frequency:10 ~ 55 H Z , Amplitude:1.5 mm 58~500Hz, 1G Sweep time: 11 min Test Period:

6 Cycles for each direction of X,

Y, Z Shock Test (non-operating) 100G, 6ms, X,Y, Z 3 times for each direction Electrostatic Discharge Test (non-operating) 200pF, 0Ω ±200V 1 time / each terminal Ta: ambient temperature [Judgement Criteria] Under the display quality test conditions with normal operation state, there should be no change which may affect practical display function. 16. Indication of Lot Number Label Indicated contents of the label Lot number Module number Contents of lot number : 1st~3rd—The OEM product 5th—Production year : 1999 ⇒9, 2000⇒A, 2001⇒B…….. 6th—Production month : 1, 2, 3,….9, A, B, C 7th~8th—Production size : 4.2” ⇒42 9th~10th— Serial numbers : 01~99 OOO-OOOOOO PM042OX1XX

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:27 17. Packing Diagram TBD

The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or discl osed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:28

Revision History

Rev. Issued Date Revised Contents 0.1 Oct. 08,2004 New