PLEY-HSZ ETA-USA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com

240 WATT

Specifications<AC/DC> PLEY**HSZ-U 240WATTS(Peak 300- 360W)/SINGLE Input Voltage Input Current Input Range Input Frequency Input Frequency Range Phase Inrush Current *1 Efficiency [%] (typical) *2 83/85 86/88 87/88 Model PLEY12HSZ-U PLEY24HSZ-U PLEY36HSZ-U Input Characteristic AC115/230V(by selector) 5.5A at AC115V/2.8A at AC230V AC85-132V/170-264V 50/60Hz 47-440Hz Single 17.5A(maximum)at AC115V/35A(maximum) at AC230V Dimension (mm) PLEY-HSZ SERIES

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com PLEHSZ Specification Specifications<AC/DC> PLEYHSZ-U 240WATTS(Peak 300-360W)/SINGLE Output Voltage [V] 12 24 36 Voltage Adjust Range Ripple and Noise mVp-p *3 220 340 460 Regulation Statistic Line Regulation mV 96 192 288 Statistic Load Regulation mV 108 216 324 Temperature Coefficient *4 DriftmV *5 75 135 195 Dynamic Load Regulation mV *6 360 720 1080 Recovery Time *6 Rise up time Hold up time 25.15 16.2 10.5 13.2 26.4 39.6 Remote Sense Remote On/Off Operating Temperature *7 Operating Humidity Storage Temperature Storage Humidity Isolation Resistance Vibration Shock Cooling Leakage Current Line Conducted Noise Safety Weight (typical) MTBF [H] Switching FrequencykHz VDE: EN60950,IEC950,VDE0805 1,130g/enclosed type:1,260g Overvoltage Protection 110% of Rated Output Voltage[V] 0 to +50 /enclosed type: -5 to +40 *4 at 0 to +50 Celsius Built to meet VDE0871 Class A Built to meet FCC Part15-B Class A UL: UL1950 CUL: CSA C22.2 No950 *1 at cold start *2 at AC115/20V and at 25 Celsius Conditions: Output shutdown(to reset,leave 1minute after shut-off) Output Characteristic +/- 10% of Rated Output Voltage(at no load within the input range) 294m/s2 Convection 1mA(maximum) at 25 ,rated input/output and rated input frequency 500mS(maximum) at 25 and rated input/output Primary-Secondary-Frame Ground 50MΩ(minimum) by DC500V insulation tester Overcurrent Protection A Primary-Secondary AC3,000V for 1minute Primary-Frame Ground AC3,000V for 1minute Withstanding Voltage Secondary-Frame Ground AC500V for 1minute -20 to +85 Celsius 10 to 85%RH(non-condensing) 30 to 85%RH(non-condensing) option 0.5mS(typical) Model PLEY12HSZ-U PLEY24HSZ-U PLEY36HSZ-U not available 0.03%/? 20mS(minimum) at 25? and rated input/output Functions *7 safety approved at 25 Celsius *3 measured by a bayonet probe at output connector at 0 to 100MHz bandwidth Environmental Current Limiting with automatic recovery 480,000 *5 for 7hour period after 1hour warm-up at 25 Celsius and rated input/output *6 when output current changed from 25% and 75% of rated output current rapidly at AC115/230V input 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s2,20minutes' period for 60minutes each along X,Y,Z axes(non-operating)

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Efficiency Curve OCP Curve Derating Curve Block Diagram