PLA15F Cosel

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 14

Technical content

AC-DC Power Supplies Enclosed Type PL A 15 F -O -O

Ordering information

1 Series name

2 Single output

3 Output wattage

4 Universal input

5 Output voltage

6 Optional *7

C : with Coating J : Connector interface T : Vertical terminal block -NO : with DIN rail R 1 2 3 4 5 6 SPECIFICATIONS MODEL PLA15F-5 PLA15F-12 PLA15F-15 PLA15F-24 INPUT VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 CURRENT[A] ACIN 100V 0.4typ (Io=90%) ACIN 115V 0.4typ (Io=100%) ACIN 230V 0.25typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 72.5typ (Io=90%) 75.5typ (Io=90%) 77.0typ (Io=90%) 78.0typ (Io=90%) ACIN 115V 73.5typ (Io=100%) 77.0typ (Io=100%) 78.5typ (Io=100%) 79.0typ (Io=100%) ACIN 230V 75.5typ (Io=100%) 78.5typ (Io=100%) 79.5typ (Io=100%) 80.0typ (Io=100%) INRUSH CURRENT[A] ACIN 100V 16typ (Io=90%) Ta=25C at cold start ACIN 115V 16typ (Io=100%) Ta=25C at cold start ACIN 230V 32typ (Io=100%) Ta=25C at cold start LEAKAGE CURRENT[mA] 0.30max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 5 12 15 24 CURRENT[A] 3 1.3 1 0.7 WATTAGE[W] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) ACIN 115V-264V 15.0 15.6 15.0 16.8 LINE REGULATION[mV] *4 20max 48max 60max 96max LOAD REGULATION[mV] *4 40max 100max 120max 150max RIPPLE[mVp-p] 0 to +50C 80max 120max 120max 120max -10 to 0C 140max 160max 160max 160max Io=0 to 35% 160max 240max 240max 280max RIPPLE NOISE[mVp-p] *1 0 to +50C 120max 150max 150max 150max -10 to 0C 160max 180max 180max 180max Io=0 to 35% 240max 300max 300max 320max TEMPERATURE REGULATION[mV] 0 to +50C 50max 120max 150max 240max -10 to +50C 60max 150max 180max 290max DRIFT[mV] *2 20max 48max 60max 96max START-UP TIME[ms] 200typ (ACIN 115V, Io=100%) *Start-up time is 700 ms typ for less than 1 minute of applying input again from turning off the input voltage. HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Not provided REMOTE ON/OFF Not provided ISOLATION INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE *5 -20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR *8 Complies with IEC61000-3-2 class A Example recommended EMI/EMC filter NAC-04-472 *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. High voltage pulse noise type : NAP series Low leakage current type : NAM series See 5.1 in Instruction Manual. April 17, 2018

Features

*1 This is the result of measurement of the testing board with capacitors of 22 mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku- Giken RM103. See 1.6 of Instr uction Manual for more details. When the load f actor is 0 - 35%, the switching power loss is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. Dr ift is the change in DC output for an eight hour period after a half-hour warm-up at 25C . As f or DC input, consult us for advice. Consult us about dynamic load and input response . Measure the output voltage by using the average mode of the tester to deal with the burst operation at 35% load or less. *5 Output po wer derating is required. See 3.2 in Instruction Manual. See 3.3 in Instr uction Manual for more details. Consult us about saf ety agency approvals for the models with optional functions. Consult us about other classes Do not use the po wer supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. P arallel operation is not possible with this mode. Sound noise ma y be heard from the power supply when used for pulse load. Block diagram OTHERS CASE SIZE/WEIGHT 38X80X73mm [1.50X3.15X2.87 inches] (Excluding terminal block and screw) (WXHXD) / 250g max COOLING METHOD Convection WARRANTY WARRANTY *6 5 years (subject to the operating conditions) FG OVER VOLTAGE PROTECTION RECTIFIER AND FILTER DC OUT FUSE AC250V2.5A CONTROL TRANSFORMER Photocoupler Photocoupler CONTROL INVERTER OVER CURRENT SENSING AC IN 85 - 264V NOISE FILTER INRUSH CURRENT LIMIT RECTIFIER AND FILTER - Compact design (Depth: 73mm 2.87inches) - Low power consumption (1.0W typ AC240Vin, no load at standard model) - UL508 approved (Except option -J), and complies with SEMI F47 - Various connection interface options (vertical terminal [-T], AMP connector [-J]) SPECIFICATIONS Output voltage adjustable potentiometer Output terminal(+) Output terminal(-) FG( ) AC(N) AC(L) M3.5 TB1 [0.49] [0.32] [0.37][0.24] [0.67] [0.5] [0.26] Name plate Terminal cover 8.2 9.56.2 17±1.5 12.7±1.5 6.5 ±1.5 12.5max [1.5] [0.79] [1.81][0.71] [0.79] Mounting hole 2-M3 18 46 ±0.5 [2.87] [1.83] [3.15] [1.4][0.71] 46.5 18 35.5 ±0.5 Point A Mounting hole (Bottom side) 2-M3 ¶ Tolerance : ±1 [±0.04] ¶ Weight : 250g max ¶ PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] ¶ Chassis material : Electric galvanizing steel board ¶ Case material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque : 0.6N-m max ¶ Screw tightening torque : 1.0N-m max V.ADJ [0.55] 14 ±1.5 [0.6] (LED)15.3 ±1.5 [0.46] (Potentiometer)11.6 ±1.5 LED April 17, 2018

AC-DC Power Supplies Enclosed Type PL A 30 F -O -O C : with Coating J : Connector interface T : Vertical terminal block -NO : with DIN rail R 1 2 3 4 5 6 Example recommended EMI/EMC filter NAC-04-472 SPECIFICATIONS MODEL PLA30F-5 PLA30F-12 PLA30F-15 PLA30F-24 INPUT VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 CURRENT[A] ACIN 100V 0.7typ (Io=90%) ACIN 115V 0.7typ (Io=100%) ACIN 230V 0.4typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 73.0typ (Io=90%) 80.0typ (Io=90%) 81.0typ (Io=90%) 82.5typ (Io=90%) ACIN 115V 74.0typ (Io=100%) 80.5typ (Io=100%) 81.5typ (Io=100%) 83.0typ (Io=100%) ACIN 230V 77.0typ (Io=100%) 81.0typ (Io=100%) 82.0typ (Io=100%) 83.5typ (Io=100%) INRUSH CURRENT[A] ACIN 100V 16typ (Io=90%) Ta=25C at cold start ACIN 115V 16typ (Io=100%) Ta=25C at cold start ACIN 230V 32typ (Io=100%) Ta=25C at cold start LEAKAGE CURRENT[mA] 0.65max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 5 12 15 24 CURRENT[A] 6 2.5 2 1.3 WATTAGE[W] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) ACIN 115V-264V 30.0 30.0 30.0 31.2 LINE REGULATION[mV] *4 20max 48max 60max 96max LOAD REGULATION[mV] *4 40max 100max 120max 150max RIPPLE[mVp-p] 0 to +50C 80max 120max 120max 120max -10 to 0C 140max 160max 160max 160max RIPPLE NOISE[mVp-p] *1 0 to +50C 120max 150max 150max 150max -10 to 0C 160max 180max 180max 180max TEMPERATURE REGULATION[mV] 0 to +50C 50max 120max 150max 240max -10 to +50C 60max 150max 180max 290max DRIFT[mV] *2 20max 48max 60max 96max START-UP TIME[ms] 150typ (ACIN 115V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Not provided REMOTE ON/OFF Not provided ISOLATION INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE *5 -20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR *8 Complies with IEC61000-3-2 class A *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. High voltage pulse noise type : NAP series Low leakage current type : NAM series See 5.1 in Instruction Manual. April 17, 2018

AC250V3.15A CONTROL CONTROL INVERTER AC IN 85 - 264V TRANSFORMER Photocoupler Photocoupler OVER CURRENT SENSING NOISE FILTER INRUSH CURRENT LIMIT RECTIFIER AND FILTER - Compact design (Depth: 88mm 3.46inches) - UL508 approved (Except option -J), and complies with SEMI F47 - Various connection interface options (vertical terminal [-T], AMP connector [-J]) *1 This is the result of measurement of the testing board with capacitors of 22 mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku- Giken RM103. See 1.6 of Instr uction Manual for more details. Dr ift is the change in DC output for an eight hour period after a half-hour warm-up at 25C . As f or DC input, consult us for advice. Consult us about dynamic load and input response Output po wer derating is required. See 3.2 in Instruction Manual. See 3.3 in Instr uction Manual for more details. *7 Consult us about saf ety agency approvals for the models with optional functions. Consult us about other classes Do not use the po wer supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. P arallel operation is not possible with this mode. Sound noise ma y be heard from the power supply when used for pulse load. OTHERS CASE SIZE/WEIGHT 38X80X88mm [1.50X3.15X3.46 inches] (Excluding terminal block and screw) (WXHXD) / 330g max COOLING METHOD Convection WARRANTY WARRANTY *6 5 years (subject to the operating conditions) SPECIFICATIONS V.ADJ TB1 M3.5 AC(L) AC(N) FG( ) Output terminal(-) Output terminal(+) Output voltage adjustable potentiometer Name plate [0.5] [0.24] [0.37] [0.32] 6.5 ±1.5 12.7±1.5 17 ±1.5 6.2 9.5 8.2 Mounting hole 2-M3 Terminal cover [0.49] [0.79] [1.5] [1.61] 12.5max 38 41 ±0.5 [1.5] [0.79] Mounting hole (Bottom side) 2-M3 [1.71] [3.15] 43.5 Point A [3.46] [2.46][0.75] 62.5 ±0.5 ¶ Tolerance : ±1 [±0.04] ¶ Weight : 330g max ¶ PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] ¶ Chassis material : Electric galvanizing steel board ¶ Case material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque : 0.6N-m max ¶ Screw tightening torque : 1.0N-m max [0.67] [0.26] [0.46] (Potentiometer)11.6±1.5 [0.6] (LED)15.3 ±1.5 [0.55] 14 ±1.5 LED April 17, 2018

AC-DC Power Supplies Enclosed Type PL A 50 F -O -O C : with Coating J : Connector interface T : Vertical terminal block -NO : with DIN rail R 1 2 3 4 5 6 Example recommended EMI/EMC filter NAC-04-472 SPECIFICATIONS MODEL PLA50F-5 PLA50F-12 PLA50F-15 PLA50F-24 INPUT VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 CURRENT[A] ACIN 100V 0.6typ (Io=90%) 0.7typ (Io=90%) ACIN 115V 0.6typ (Io=100%) 0.7typ (Io=100%) ACIN 230V 0.3typ (Io=100%) 0.4typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 74.5typ (Io=90%) 80.0typ (Io=90%) 80.0typ (Io=90%) 81.5typ (Io=90%) ACIN 115V 75.0typ (Io=100%) 80.5typ (Io=100%) 80.5typ (Io=100%) 82.0typ (Io=100%) ACIN 230V 76.5typ (Io=100%) 82.0typ (Io=100%) 82.0typ (Io=100%) 84.0typ (Io=100%) POWER FACTOR ACIN 100V 0.97typ (Io=90%) 0.98typ (Io=90%) ACIN 115V 0.97typ (Io=100%) 0.98typ (Io=100%) ACIN 230V 0.85typ (Io=100%) 0.87typ (Io=100%) INRUSH CURRENT[A] ACIN 100V 16typ (Io=90%) Ta=25C at cold start ACIN 115V 16typ (Io=100%) Ta=25C at cold start ACIN 230V 32typ (Io=100%) Ta=25C at cold start LEAKAGE CURRENT[mA] 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 5 12 15 24 CURRENT[A] 8 4.3 3.5 2.2 WATTAGE[W] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) ACIN 115V-264V 40.0 51.6 52.5 52.8 LINE REGULATION[mV] *4 20max 48max 60max 96max LOAD REGULATION[mV] *4 40max 100max 120max 150max RIPPLE[mVp-p] 0 to +45C 80max 120max 120max 120max -10 to 0C 140max 160max 160max 160max RIPPLE NOISE[mVp-p] *1 0 to +45C 120max 150max 150max 150max -10 to 0C 160max 180max 180max 180max TEMPERATURE REGULATION[mV] 0 to +45C 50max 120max 150max 240max -10 to +45C 60max 150max 180max 290max DRIFT[mV] *2 20max 48max 60max 96max START-UP TIME[ms] 350typ (ACIN 115V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Not provided REMOTE ON/OFF Not provided ISOLATION INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE *5 -20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR *8 Complies with IEC61000-3-2 class A *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. High voltage pulse noise type : NAP series Low leakage current type : NAM series See 5.1 in Instruction Manual. April 17, 2018

AC250V 2.5A CONTROL CONTROL CONTROL INVERTERRECTIFIER AND FILTER INVERTER BOOSTER INDUCTOR CURRENT SENSING AC IN 85 - 264V TRANSFORMER Photocoupler Photocoupler OVER CURRENT SENSING - Compact design (Depth: 99mm 3.90inches) - UL508 approved (Except option -J), and complies with SEMI F47 - Various connection interface options (vertical terminal [-T], AMP connector [-J]) *1 This is the result of measurement of the testing board with capacitors of 22 mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku- Giken RM103. See 1.6 of Instr uction Manual for more details. Dr ift is the change in DC output for an eight hour period after a half-hour warm-up at 25C . As f or DC input, consult us for advice. Consult us about dynamic load and input response Output po wer derating is required. See 3.2 in Instruction Manual. See 3.3 in Instr uction Manual for more details. *7 Consult us about saf ety agency approvals for the models with optional functions. Consult us about other classes Do not use the po wer supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. P arallel operation is not possible with this mode. Sound noise ma y be heard from the power supply when used for pulse load. OTHERS CASE SIZE/WEIGHT 38X80X99mm [1.50X3.15X3.90 inches] (Excluding terminal block and screw) (WXHXD) / 400g max COOLING METHOD Convection WARRANTY WARRANTY *6 5 years (subject to the operating conditions) SPECIFICATIONS V.ADJ Output voltage adjustable potentiometer Output terminal(+) Output terminal(-) FG( ) AC(N) AC(L) M3.5 TB1 [0.49] [0.32] [0.37][0.24] [0.67] [0.5] [0.26] Name plate Terminal cover 8.2 9.56.2 17 ±1.5 12.7 ±1.5 6.5 ±1.5 12.5max [1.5] [0.79] [2.05][1.5] [0.79] Mounting hole 2-M3 38 52 ±0.5 [3.15] [1.75] [2.99][0.75] [3.9] Mounting hole (Bottom side) 2-M3 44.5 19 76 ±0.5 Point A ¶ Tolerance : ±1 [±0.04] ¶ Weight : 400g max ¶ PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] ¶ Chassis material : Electric galvanizing steel board ¶ Case material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque : 0.6N-m max ¶ Screw tightening torque : 1.0N-m max [0.6] (LED)15.3 ±1.5 [0.46] (Potentiometer)11.6±1.5 [0.55] 14 ±1.5 LED April 17, 2018

AC-DC Power Supplies Enclosed Type PL A 100 F -O -O C : with Coating R : Remote on/off (Required external power source) J : Connector interface T : Vertical terminal block -NO : with DIN rail See 5.1 in Instruction Manual. R 1 2 3 4 5 6 SPECIFICATIONS MODEL PLA100F-12 PLA100F-15 PLA100F-24 PLA100F-36 PLA100F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 CURRENT[A] ACIN 100V 1.2typ (Io=90%) ACIN 115V 1.1typ (Io=100%) ACIN 230V 0.6typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 82typ (Io=90%) 83typ (Io=90%) 85typ (Io=90%) 86typ (Io=90%) 86typ (Io=90%) ACIN 115V 82typ (Io=100%) 83typ (Io=100%) 85typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) ACIN 230V 85typ (Io=100%) 86typ (Io=100%) 88typ (Io=100%) 89typ (Io=100%) 89typ (Io=100%) POWER FACTOR ACIN 100V 0.98typ (Io=90%) ACIN 115V 0.98typ (Io=100%) ACIN 230V 0.95typ (Io=100%) * Power factor correction is stopped at AC250V or more. INRUSH CURRENT[A] ACIN 100V 16typ (Io=90%) Ta=25C at cold start ACIN 115V 16typ (Io=100%) Ta=25C at cold start ACIN 230V 32typ (Io=100%) Ta=25C at cold start LEAKAGE CURRENT[mA] 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 12 15 24 36 48 CURRENT[A] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) WATTAGE[W] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) LINE REGULATION[mV] *4 48max 60max 96max 144max 192max LOAD REGULATION [mV] Io=30 to 100% 100max 120max 150max 150max 300max Io=0 to 30% Burst operation (Please contact us about detail) RIPPLE[mVp-p] Io: load factor 0 to +40C 120max 120max 120max 150max 150max -10 to 0C 160max 160max 160max 200max 400max Io=0 to 30% 500max 500max 500max 500max 500max RIPPLE NOISE[mVp-p] Io: load factor 0 to +40C 150max 150max 150max 200max 200max -10 to 0C 180max 180max 180max 240max 500max Io=0 to 30% 600max 600max 600max 600max 600max TEMPERATURE REGULATION[mV] 0 to +40C 120max 150max 240max 360max 480max -10 to +40C 180max 180max 290max 440max 600max DRIFT[mV] *2 48max 60max 96max 144max 192max START-UP TIME[ms] 500typ (ACIN 115V, Io=100%) Ta=25C HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Not provided REMOTE ON/OFF Optional (Required external power source. Option -R) ISOLATION INPUT-OUTPUT RC *9 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) OUTPUT RC-FG *9 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) OUTPUT-RC *9 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE *5 -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR *8 Complies with IEC61000-3-2 class A *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. Example recommended EMI/EMC filter NAC-04-472 * Please consider "PBA100F-5-N" about 5V output with case cover. * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. High voltage pulse noise type : NAP series Low leakage current type : NAM series April 17, 2018

(Bottom side) 3-M3 Mounting hole Terminal cover 2-M3 CN4 Connector for Remote ON/OFF (option) M3.5 Name plate AC(L) AC(N) FG( ) Output terminal(–) Output terminal(+) Output voltage adjustable potentiometer LED 3.5 3.5 28.5 101 12 18±0.5 66.5±0.533.5 12.5max 109 19.5 76±0.5 14.6±1.5 22±1.5 6.2 9.5 8.2 32.8±1.5 [0.77] [0.49] [4.29] [2.99] [0.16] [3.98] [1.32] [2.62] [0.32] [0.86] [0.24] [0.83] [0.83] [0.47] [0.71] [1.61] [2.01] [3.82] [0.14] [0.14] [1.12] [1.29] [0.37] [0.57] 14±1.5 [0.55] 15.3±1.5 (LED) [0.6] 11.6±1.5 (potentiometer) [0.46] ¶ Tolerance : ±1 [±0.04] ¶ Weight : 500g max ¶ PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] ¶ Chassis material : Aluminum ¶ Cover material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque : 0.49N-m max ¶ Screw tightening torque : M3.5 1.0N-m max ¶ Connect the input FG to safety earth ground. PLA100F External view *1 This is the result of measurement of the testing board with capacitors of 22 mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instr uction Manual for more details. When the load f actor is 0 - 30%, the switching power loss is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. D rift is the change in DC output for an eight hour period after a half- hour warm-up at 25C. As for DC input, consult us for advice. *4 Consult us about dynamic load and input response . Measure the output voltage by using the average mode of the tester to deal with the burst operation at 30% load or less. Output po wer derating is required. See 3.2 in Instruction Manual. See 3.3 in Instr uction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *8 Consult us about other classes . Block diagram The external size of –R option, –J option, –N1 option and –T option models is different from the standard model. See “5. Options and Others” in Instruction Manual for more details. *9 The RC ter minal is added to option –R models. The RC terminal is isolated from input, output, and FG. Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. * P arallel operation is not possible with this mode. Sound noise ma y be heard from the power supply when used for pulse load. OTHERS CASE SIZE/WEIGHT 41X97X109mm [1.61X3.82X4.29 inches] (Excluding terminal block and screw) (WXHXD) / 500g max COOLING METHOD Convection WARRANTY WARRANTY *6 5 years (subject to the operating conditions) AC IN 85 - 264V FG DC OUT RC(-R) RECTIFIER OVER VOLTAGE PROTECTION CURRENT SENSING NOISE FILTER INRUSH CURRENT LIMIT RECTIFIER AND FILTER FUSE 250V 3.15A INVERTER CONTROL EXTERNAL SOURCECONTROL INVERTER CURRENT SENSING RECTIFIER AND FILTER BOOSTER INDUCTOR - Compact design (Depth: 109mm 4.29inches) - High efficiency (88%typ PLA100F-24, AC230Vin, 100% load) - Low power consumption (1.5W typ AC240Vin, no load at standard model) - UL508 approved (Except option -J), and complies with SEMI F47 (see instruction manual 1.1) - Various connection interface options (vertical terminal [-T], AMP connector [-J]) SPECIFICATIONS April 17, 2018

AC-DC Power Supplies Enclosed Type PL A 150 F -O -O C : with Coating R : Remote on/off (Required external power source) J : Connector interface T : Vertical terminal block -NO : with DIN rail See 5.1 in Instruction Manual. R 1 2 3 4 5 6 SPECIFICATIONS MODEL PLA150F-12 PLA150F-15 PLA150F-24 PLA150F-36 PLA150F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 CURRENT[A] ACIN 100V 1.7typ (Io=90%) ACIN 115V 1.6typ (Io=100%) ACIN 230V 0.8typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 84typ (Io=90%) 84typ (Io=90%) 87typ (Io=90%) 87typ (Io=90%) 87typ (Io=90%) ACIN 115V 84typ (Io=100%) 84typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) ACIN 230V 87typ (Io=100%) 87typ (Io=100%) 90typ (Io=100%) 90typ (Io=100%) 90typ (Io=100%) POWER FACTOR ACIN 100V 0.98typ (Io=90%) ACIN 115V 0.98typ (Io=100%) ACIN 230V 0.95typ (Io=100%) * Power factor correction is stopped at AC250V or more. INRUSH CURRENT[A] ACIN 100V 16typ (Io=90%) Ta=25C at cold start ACIN 115V 16typ (Io=100%) Ta=25C at cold start ACIN 230V 32typ (Io=100%) Ta=25C at cold start LEAKAGE CURRENT[mA] 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 12 15 24 36 48 CURRENT[A] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) ACIN 115V-264V 12.5 10 6.4 4.2 3.2 WATTAGE[W] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) LINE REGULATION[mV] *4 48max 60max 96max 144max 192max LOAD REGULATION [mV] Io=30 to 100% 100max 120max 150max 150max 300max Io=0 to 30% Burst operation (Please contact us about detail) RIPPLE[mVp-p] Io: load factor 0 to +40C 120max 120max 120max 150max 150max -10 to 0C 160max 160max 160max 200max 400max Io=0 to 30% 500max 500max 500max 500max 500max RIPPLE NOISE[mVp-p] Io: load factor 0 to +40C 150max 150max 150max 200max 200max -10 to 0C 180max 180max 180max 240max 500max Io=0 to 30% 600max 600max 600max 600max 600max TEMPERATURE REGULATION[mV] 0 to +40C 120max 150max 240max 360max 480max -10 to +40C 180max 180max 290max 440max 600max DRIFT[mV] *2 48max 60max 96max 144max 192max START-UP TIME[ms] 500typ (ACIN 115V, Io=100%) Ta=25C HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Not provided REMOTE ON/OFF Optional (Required external power source. Option -R) ISOLATION INPUT-OUTPUT RC *9 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) OUTPUT RC-FG *9 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) OUTPUT-RC *9 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE *5 -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR *8 Complies with IEC61000-3-2 class A Example recommended EMI/EMC filter NAC-04-472 * Please consider "PBA150F-5-N" about 5V output with case cover. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. High voltage pulse noise type : NAP series Low leakage current type : NAM series April 17, 2018

*1 This is the result of measurement of the testing board with capacitors of mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instr uction Manual for more details. When the load f actor is 0 - 30%, the switching power loss is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. Dr ift is the change in DC output for an eight hour period after a half- hour warm-up at 25C. As f or DC input, consult us for advice. Consult us about dynamic load and input response . Measure the output voltage by using the average mode of the tester to deal with the burst operation at 30% load or less. Output po wer derating is required. See 3.2 in Instruction Manual. See 3.3 in Instr uction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *8 Consult us about other classes . Block diagram The external size of –R option, –J option, –N1 option and –T option models is different from the standard model. See “5. Options and Others” in Instruction Manual for more details. *9 The RC ter minal is added to option –R models. The RC terminal is isolated from input, output, and FG. Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. * P arallel operation is not possible with this mode. Sound noise ma y be heard from the power supply when used for pulse load. OTHERS CASE SIZE/WEIGHT 41X97X129mm [1.61X3.82X5.08 inches] (Excluding terminal block and screw) (WXHXD) / 600g max COOLING METHOD Convection WARRANTY WARRANTY *6 5 years (subject to the operating conditions) AC IN 85 - 264V FG DC OUT RC(-R) RECTIFIER OVER VOLTAGE PROTECTION CURRENT SENSING NOISE FILTER INRUSH CURRENT LIMIT RECTIFIER AND FILTER FUSE 250V 4A INVERTER CONTROL EXTERNAL SOURCECONTROL INVERTER CURRENT SENSING RECTIFIER AND FILTER BOOSTER INDUCTOR - Compact design (Depth: 129mm 5.08inches) - High efficiency (90%typ PLA150F-24, AC230Vin, 100% load) - Low power consumption (1.5W typ AC240Vin, no load at standard model) - UL508 approved (Except option -J), and complies with SEMI F47 (see instruction manual 1.1) - Various connection interface options (vertical terminal [-T], AMP connector [-J]) SPECIFICATIONS LED Output voltage adjustable potentiometer Output terminal(+) Output terminal(–) FG( ) AC(N) AC(L) Name plate M3.5 2-M3 Mounting hole 3-M3 Mounting hole (Bottom side) Point A B Point B CN4 Connector for Remote ON/OFF (option) Terminal cover 8.2 9.56.2 22±1.5 14.6±1.5 96±0.519 49.5 129 12.5max 48 70±0.5 18±0.512 121 28.5 3.5 3.5 32.8±1.5 [0.32] [0.86] [0.57] [0.24] [1.29] [0.37] [0.75] [0.49] [5.08] [3.78] [1.95] [3.82] [0.16] [4.76] [1.89] [2.76] [0.83] [0.83] [0.47] [0.71] [1.61] [0.14] [0.14] [1.12] 14±1.5 [0.55] 15.3±1.5(LED) [0.6] 11.6±1.5(potentiometer) [0.46] ¶ Tolerance : ±1 [±0.04] ¶ Weight : 600g max ¶ PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] ¶ Chassis material : Aluminum ¶ Cover material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque : 0.49N-m max ¶ Screw tightening torque : M3.5 1.0N-m max ¶ Connect the input FG to safety earth ground. April 17, 2018

AC-DC Power Supplies Enclosed Type PL A 300 F -O -O C : with Coating G : Low leakage current V : External potentiometer for output voltage adjustment U : Low input voltage stop (Complies with SEMI F-47) R : Remote on/off (Required external power source) F4: Low speed fan T2: Horizontal terminal block (non-screw-hold type) See 5.1 in Instruction Manual. R 1 2 3 4 5 6 SPECIFICATIONS MODEL PLA300F-5 PLA300F-12 PLA300F-15 PLA300F-24 PLA300F-36 PLA300F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 CURRENT[A] ACIN 100V 3.1typ (Io=90%) 3.4typ (Io=90%) ACIN 115V 3.0typ (Io=100%) 3.3typ (Io=100%) ACIN 230V 1.5typ (Io=100%) 1.7typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 73typ (Io=90%) 78typ (Io=90%) 79typ (Io=90%) 81typ (Io=90%) 81typ (Io=90%) 82typ (Io=90%) ACIN 115V 74typ (Io=100%) 78typ (Io=100%) 80typ (Io=100%) 82typ (Io=100%) 82typ (Io=100%) 83typ (Io=100%) ACIN 230V 77typ (Io=100%) 81typ (Io=100%) 83typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) POWER FACTOR ACIN 100V 0.98typ (Io=90%) ACIN 115V 0.98typ (Io=100%) ACIN 230V 0.95typ (Io=100%) INRUSH CURRENT[A] ACIN 100V 20typ (Io=90%) Ta=25C at cold start ACIN 115V 20typ (Io=100%) Ta=25C at cold start ACIN 230V 40typ (Io=100%) Ta=25C at cold start LEAKAGE CURRENT[mA] 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 5 12 15 24 36 48 CURRENT[A] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) ACIN 115V-264V 50 25 20 12.5 8.4 6.3 WATTAGE[W] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) ACIN 115V-264V 250 300 300 300 302.4 302.4 LINE REGULATION[mV] *4 20max 48max 60max 96max 144max 192max LOAD REGULATION[mV] *4 40max 100max 120max 150max 150max 300max RIPPLE[mVp-p] 0 to +50C 80max 120max 120max 120max 150max 150max -10 to 0C 140max 160max 160max 160max 160max 400max RIPPLE NOISE[mVp-p] 0 to +50C 120max 150max 150max 150max 200max 200max -10 to 0C 160max 180max 180max 180max 240max 500max TEMPERATURE REGULATION[mV] 0 to +50C 50max 120max 150max 240max 360max 480max -10 to +50C 75max 180max 180max 290max 440max 600max DRIFT[mV] *2 20max 48max 60max 96max 144max 192max START-UP TIME[ms] 300typ (ACIN 115V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Not provided REMOTE ON/OFF Optional (Required external power source. Option -R) ISOLATION INPUT-OUTPUT RC *10 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) OUTPUT RC-FG *10 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) OUTPUT-RC *10 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE *5 -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR *9 Complies with IEC61000-3-2 class A Example recommended EMI/EMC filter NAC-06-472 *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. High voltage pulse noise type : NAP series Low leakage current type : NAM series April 17, 2018

*1 This is the result of measurement of the testing board with capacitors of mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instr uction Manual for more details. Dr ift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. Output po wer derating is required. As for DC input, consult us for advice. *4 Consult us about dynamic load and input response . See 3.2 in Instr uction Manual. See 3.3 in Instr uction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *8 The f an speed slows down at no load. Consult us about other classes *10 The RC ter minal is added to option –R models. The RC terminal is isolated from input, output, and FG. Block diagram The external size of –V option, –R option, and –T2 option models is different from the standard model. See “5. Options and Others” in Instruction Manual for more details. * Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. * P arallel operation is not possible with this mode. Sound noise ma y be heard from the power supply when used for pulse load. - Cost-effective - Longer life (see Instruction Manual) - Low profile (meets 1U height = 41 mm or 1.61 inches) - Wide operating temperature range (-20 to +70 see instruction manual) - Screw hold type terminal block - Slow fan speed at no load - Many optional functions - Complies with SEMI F-47 (-U option, see Instruction Manual for details) OTHERS CASE SIZE/WEIGHT 102X41X190mm [4.02X1.61X7.48 inches] (Excluding terminal block and screw) (WXHXD) / 1.0kg max COOLING METHOD *8 Forced cooling (internal fan) WARRANTY WARRANTY *6 5 years (subject to the operating conditions) SPECIFICATIONS FG(N) AC V.ADJ(L) AC -V -V +V +V FG( ) AC(L) AC(N) Output terminal (+) Output terminal (–) Output voltage adjustable potentiometer LED 12.5 5.75 [0.23] [0.49] ±1.5 ±1.5 [0.34] 5.7 19.8 [0.78] ±1.5 8.6 [0.22][0.39] 4-M4 Mounting Hole10.519.5 150 ±0.5 AIR FLOW [0.98] [1.61] ±0.5 12.5 150 190 5max [0.2max] [0.49] [5.91] [7.48] ±0.5 Name plate20max [0.79max] 4-M4 Mounting Hole (Bottom side) 102 19.5 [0.77] [2.36] [4.02] ±0.5 ¶ Tolerance : ±1 [±0.04] ¶ Weight : 1.0kg max ¶ PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] ¶ Chassis material : Aluminum ¶ Case material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque : 1.2N m max ¶ Screw tightening torque : 1.6N m max ¶ Connect the input FG to safety earth ground. 16.8 (LED) [0.66] ±1.5 16.6 [0.65] ±1.5 13.1 (potentiometer) [0.52] ±1.5 April 17, 2018

AC-DC Power Supplies Enclosed Type PL A 600 F -O -O R 1 2 3 4 5 6 SPECIFICATIONS MODEL PLA600F-12 PLA600F-15 PLA600F-24 PLA600F-36 PLA600F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *4 CURRENT[A] ACIN 100V 6.7typ (Io=90%) ACIN 115V 6.5typ (Io=100%) ACIN 230V 3.2typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 81typ (Io=90%) 81typ (Io=90%) 84typ (Io=90%) 85typ (Io=90%) 85typ (Io=90%) ACIN 115V 81typ (Io=100%) 81typ (Io=100%) 84typ (Io=100%) 85typ (Io=100%) 85typ (Io=100%) ACIN 230V 84typ (Io=100%) 84typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) POWER FACTOR ACIN 100V 0.98typ (Io=90%) ACIN 115V 0.98typ (Io=100%) ACIN 230V 0.95typ (Io=100%) INRUSH CURRENT[A] ACIN 100V 20/40typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) ACIN 115V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) ACIN 230V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) LEAKAGE CURRENT[mA] 1.5max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 12 15 24 36 48 CURRENT[A] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) ACIN 115V-264V 50 40 25 16.7 12.5 WATTAGE[W] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) ACIN 115V-264V 600 600 600 601.2 600 LINE REGULATION[mV] *8 48max 60max 96max 144max 192max LOAD REGULATION[mV] *8 100max 120max 150max 150max 300max RIPPLE[mVp-p] 0 to +50C 120max 120max 120max 150max 150max -20 to 0C 160max 160max 160max 160max 400max RIPPLE NOISE[mVp-p] 0 to +50C 150max 150max 150max 200max 200max -20 to 0C 180max 180max 180max 240max 500max TEMPERATURE REGULATION[mV] 0 to +50C 120max 150max 240max 360max 480max -20 to +50C 180max 180max 290max 440max 600max DRIFT[mV] *2 48max 60max 96max 144max 192max START-UP TIME[ms] 300typ (ACIN 115V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Optional (Option -W) REMOTE ON/OFF Optional (Required external power source. Option -R) ISOLATION INPUT-OUTPUT RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) OUTPUT RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) OUTPUT-RC *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE *5 -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR *10 Complies with IEC61000-3-2 class A

1 Ser ies name

C : with Coating G : Low leakage current V : External potentiometer for output voltage adjustment U : Low input voltage stop (Complies with SEMI F-47) W: Parallel operation, LV alarm Remote sensing R : Remote on/off (Required external power source) F4 : Low speed fan T2: Horizontal terminal block (non-screw-hold type) See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. Please consider “PJA600F-5” about 5V output. Example recommended EMI/EMC filter NAC-16-472 * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. High voltage pulse noise type : NAP series Low leakage current type : NAM series April 17, 2018

*1 This is the result of measurement of the testing board with capacitors of mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instr uction Manual for more details. Dr ift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 The RC ter minal is added to option –R models. The RC terminal is isolated from input, output, and FG. As for DC input, consult us for advice. *5 Output po wer derating is required. See 3.2 in Instruction Manual. See 3.3 in Instr uction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *8 Consult us about dynamic load and input response . External view Block diagram FAN External source AC IN 85 - 264V FG RECTIFIER OVER VOLTAGE PROTECTION THERMAL PROTECTION DETECTING OUTPUT VOLTAGE PARALLEL-OPERATION CIRCUIT CURRENT SENSING NOISE FILTER INRUSH CURRENT LIMIT RECTIFIER AND FILTER DC OUT LV alarm (-W) Current balance (-W) RC (-R) FUSE 250V 16A INVERTER CONTROL CONTROL CONTROL CONTROL INVERTER CURRENT SENSING RECTIFIER AND FILTER BOOSTER INDUCTOR The external size of –V option, –W option, –R option, and –T2 option is different from the standard model. See “5. Options and Others” in Instruction Manual for more details. *9 The f an speed slows down at no load. *10 Consult us about other classes Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is allowed for PLA600F models with the –W option only. * Sound noise may be heard from the power supply when used for pulse load. OTHERS CASE SIZE/WEIGHT 120X61X215mm [4.72X2.40X8.46 inches] (Excluding terminal block and screw) (WXHXD) / 2.0kg max COOLING METHOD *9 Forced cooling (internal fan) WARRANTY WARRANTY *6 5 years (subject to the operating conditions) SPECIFICATIONS FG AC (N) (L) AC (+V,-V) Mounting Hole LED AIR FLOW 4-M4 Name plate V.ADJ -V -V +V +V 4-M4 FG( ) (AC,FG) M3.5 AC(L) AC(N) 10.5±1.5 18.5±1.5 15.5 38±0.5 150±0.535 150±0.5 21max 3max215 10 100±0.5 120 24.8±1.5 79.25±1.510 108.1 7.412 15.5±1.5 [0.41] [0.73] [0.98] [0.29][0.47] [0.39] [0.39] [3.12] [0.32] [0.61] [0.83max] [1.38] [5.91] [8.46] [0.12max] [0.39] [3.94] [4.72] [1.38] [5.91] [1.5] [2.4] [0.61] ¶ Tolerance : ±1 [±0.04] ¶ Weight : 2.0kg max ¶ PCB Material/thickness : FR-4 / 1.6mm [0.06inches] ¶ Chassis material : Electric galvanizing steel board ¶ Case material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque : 1.5N-m max ¶ Screw tightening torque : M3.5 0.8N-m max M4 1.6N-m max ¶ Connect the input FG to safety earth ground. Mounting Hole (Bottom sides) Output terminal cover Output terminal (-) Output terminal (+) Output voltage adjustable potentiometer 15.8±1.5 (LED) 12.1±1.5 (potentiometer) 16.6±1.5 26.6±1.5 [0.62] [1.05] [0.65] [0.48] - Cost-effective - Longer life (see Instruction Manual) - Low profile (meets 2U height = 61 mm or 2.40 inches) - Wide operating temperature rang e (-20 to +70 see instruction manual) - Screw hold type terminal block - Slow fan speed at no load - Many optional functions - Complies with SEMI F-47 (-U option, see Instruction Manual for details) April 17, 2018 Powered by TCPDF (www.tcpdf.org)