Features

• For installation in housing • PL3... with valve and screen connection • Valve LEDs disconnectable (wire jumper) • ATEX & IECEX certifications Accessories BT32 Activator for F25 series BT32XS Activator for F25 series BT32XAS Activator for F25 series BT33 Activator for F25 series BT34 Activator for F25 series Technical Data General specifications Switching function 2 x normally closed (NC) Output type NAMUR Rated operating distance s n 3 mm Installation flush mountable Assured operating distance s a 0 ... 2.43 mm Reduction factor rAl 0.52 Reduction factor rCu 0.43 Reduction factor r304 0.86 Reduction factor rSt37 1 Reduction factor rBrass 0.54 Output type 2-wire Nominal ratings Nominal voltage U o 8.2 V (Ri approx. 1 kΩ) Operating voltage U B 5 ... 25 V Switching frequency f 0 ... 100 Hz Hysteresis H typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection yes Suitable for 2:1 technology yes , Revers e polarity protection diode not required Design data Current consumption Measuring plate not detected ≥ 3 mA at nominal voltage Measuring plate detected ≤ 1 mA at nominal voltage Time delay before availability t v ≤ 1 ms Switching state indicator LED, yellow Valve status indicator LED, yellow can be switched off by of DB1 Functional safety related parameters MTTFd 834 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Mechanical specifications Connection (system side) Cage tension spring terminals Core cross-section (system side) up to 2.5 mm2 Connection (valve side) Cage tension spring terminals Core cross-section (valve side) up to 2.5 mm2 Housing material PBT Sensing face PBT Mass 91 g Tightening torque, fastening screws 0.3 Nm General information Use in the hazardous area see instruction manuals Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibility NE 21:2007 Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Dimensions Sensor 1 Sensor 2 LED Sensor 1Sensor 2 11.5 4.8 21.5 45° 45° LED V S 123

123 DB1

R20.8

Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Inductive sensor PL3-F25-N4-K Release date: 2019-05-15 16:53 Date of issue: 2019-05-15 291801_eng.xml Electrical Connection PL3-...-N4 I I II 7 3 S S V V+5 V-2 I II 2

Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Inductive sensor PL3-F25-N4-K Release date: 2019-05-15 16:53 Date of issue: 2019-05-15 291801_eng.xml Data for application in connection with hazardous areas Equipment protection level Ga , Gb , Gc (ic) , Mb Equipment protection level Ga Type of protection intrinsic safety CE marking 0102 Certificates ATEX certificate TÜV 99 ATEX 1479 X ATEX marking ¬ II 1G Ex ia IIC T6...T1 Ga Standards EN 60079-0:2012+A11:2013 , EN 60079-11:2012 IECEx certificate IECEx TUN 17.0021X IECEx marking Ex ia IIC T6...T1 Ga Standards IEC 60079-0:2011 , IEC 60079-11:2011 Effective internal capacitance C i ≤ 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. Effective internal inductance L i ≤ 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. Maximum permissible ambient temperature Tamb Also observe the maximum permissible ambient temp erature stated in the general technical data. Keep to the lower of the two values. for ATEX at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , at U i = 15 V , Ii = 25 mA , Pi = 64 mW , at U i = 15 V , Ii = 52 mA , Pi = 169 mW , for IECEx at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 15 V , Ii = 25 mA , Pi = 64 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 15 V , Ii = 52 mA , Pi = 169 mW , Maximum values of the valve circuit The value applies to each valve circuit. A cable length of 10 m is considered. Voltage U i ≤ 32 V Current I i ≤ 240 mA Internal capacitance C i ≤ 10 nF Internal inductance L i ≤ 20 µH

Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Inductive sensor PL3-F25-N4-K Release date: 2019-05-15 16:53 Date of issue: 2019-05-15 291801_eng.xml Equipment protection level Gb Type of protection intrinsic safety CE marking 0102 Certificates ATEX certificate TÜV 99 ATEX 1479 X ATEX marking ¬ II 1G Ex ia IIC T6…T1 Ga Standards EN 60079-0:2012+A11:2013 , EN 60079-11:2012 IECEx certificate IECEx TUN 17.0021X IECEx marking Ex ia IIC T6...T1 Ga Standards IEC 60079-0:2011 , IEC 60079-11:2011 Effective internal capacitance C i ≤ 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. Effective internal inductance L i ≤ 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. Maximum permissible ambient temperature Tamb Also observe the maximum permissible ambient temp erature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 15 V , Ii = 25 mA , Pi = 64 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 15 V , Ii = 52 mA , Pi = 169 mW , Maximum values of the valve circuit The value applies to each valve circuit. A cable length of 10 m is considered. Voltage U i ≤ 32 V Current I i ≤ 240 mA Internal capacitance C i ≤ 10 nF Internal inductance L i ≤ 20 µH

Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Inductive sensor PL3-F25-N4-K Release date: 2019-05-15 16:53 Date of issue: 2019-05-15 291801_eng.xml Equipment protection level Gc (ic) Type of protection intrinsic safety CE marking 0102 Certificates ATEX certificate PF 13 CERT 2895 X ATEX marking ¬ II 3G Ex ic IIC T6…T1 Gc Standards EN 60079-0:2012+A11:2013 , EN 60079-11:2012 Effective internal capacitance C i ≤ 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. Effective internal inductance L i ≤ 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. Maximum permissible ambient temperature Tamb Also observe the maximum permissible ambient temp erature stated in the general technical data. Keep to the lower of the two values. at U i = 20 V , Ii = 25 mA , Pi = 34 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 20 V , Ii = 25 mA , Pi = 64 mW , T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U i = 20 V , Ii = 52 mA , Pi = 169 mW , Maximum values of the valve circuit The value applies to each valve circuit. A cable length of 10 m is considered. Voltage U i ≤ 32 V Current I i ≤ 240 mA Internal capacitance C i ≤ 10 nF Internal inductance L i ≤ 20 µH Equipment protection level Mb Type of protection intrinsic safety CE marking 0102 Certificates IECEx certificate IECEx TUN 17.0021X IECEx marking Ex ia I Mb Standards IEC 60079-0:2011 , IEC 60079-11:2011 Effective internal capacitance C i ≤ 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. Effective internal inductance L i ≤ 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. Maximum permissible ambient temperature Tamb Also observe the maximum permissible ambient temp erature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 95 °C (203 °F) Maximum values of the valve circuit The value applies to each valve circuit. A cable length of 10 m is considered. Voltage U i ≤ 32 V Current I i ≤ 240 mA Internal capacitance C i ≤ 10 nF Internal inductance L i ≤ 20 µH