› Plug-In Timer 11 pins › Multifunction or monofunction › Compact body for space saving › Wide time range (from 0.5 seconds to 10 days delay) › Universal power supply (12-240 Vz) › 1 or 2 relay outputs (SPDT / Changeover) › Protective cover › LED status indicator › 3-wire PNP sensor compatible › 11-pins connections PU2R10MV1 Multifunctions U - Monofunction Ad - Instantaneous PA2R10MV1 Monofunction A, At PC2R10MV1 Monofunction C PL2R10MV1 Monofunction L, LiProduct selection Function Output Supply Voltage Part Number Multifunction U: (A, At, B, C, H, Ht, D, Di, Ac, Bw) Ad - Instantaneous 2 relays 12 to 240 Vz PU2R10MV1 A, At 2 relays 12 to 240 Vz PA2R10MV1 C 2 relays 12 to 240 Vz PC2R10MV1 L, Li 2 relays 12 to 240 Vz PL2R10MV1 Description: Syr-line, the new specialized range at Crouzet, aimed to satisfy the most unique requirements of your applications by innovating in design, engineering and development. The Plug in Analog Timers, a new family of 11 timers with multifuction or monofunction, universal power supply, wide time range, with all the classic functions. For more information about Crouzet’s Syr-line range, please visit www.crouzet.com. You have a project? Contact us on www.crouzet.com P U 2 R 10 MV1 Function A: ON-Delay C: OFF-Delay L: Repeat Cycle U: Multifuction U Output Type R: Relay Power Supply MV1: 12-240V AC/DC Output Qua ntity 1: 1 Output 2: 2 Outputs Output Power 10: 10 A Type O: Plug-in 8-Pins P: Plug-in 11-Pins PART NUMBERING SYS TEM
| 2 | 10/2018 | Plug-In Timer PU2R10MV1 PA2R10MV1 PC2R10MV1 PL2R10MV1 Power Supply Rated supply voltage Un 12 to 240 Vz Voltage supply tolerance -15 %, +10 % AC supply voltage frequency 50 / 60 Hz ± 5% Galvanic isolation of supply / inputs No Power consumption @ Un Approx. 3 VA (Va) 1.5 W (Vc) Immunity to power micro cuts 10 ms Timing Control Minimum control pulse duration (IEC 1812-1) 40 ms 100 ms with load Recovery time (after by de-energisation) (IEC 1812-1) 120 ms Repeatability (IEC 1812-1) ≤ ± 0.5 % Setting Accuracy (IEC 1812-1) ≤ ± 10 % Temperature drift ≤ ± 0.05 % / °C Voltage drift ≤ ± 0.2 % / V Relay output Contact arrangement 2 CO (SPDT) (ChangeOver -Single Pole Double Throw-) R1: Follow timing function R2: Follow timing function / Instantenous
2 CO (SPDT) (ChangeOver -Single Pole Double Throw-)
Maximum switching voltage 250 Va / 10 A resistive / 125 Vc / 0.3 A resistive Switching current rate (resistive) NO / NC: 10 A 250 Va / 10 A 30 Vc @ 25 °C NO / NC: 5 A 250 Va / 5 A 30 Vc @ 60 °C Minimum switching contact 10 mA / 5 Vc Maximum switching power (resistive) 2500 VA / 300 W Electrical life 105 cycles min at 250 Va/ 10 A resistive (NO only) Maximum rate (at max switching power) 360 cycles /hour Mechanical life 10 x 106 cycles Rated impulse voltage 4 kV (1.2/50 µs) Dielectric strength between coil / contacts (IEC 60664-1) 2.5 kV / 1 min / 1 mA / 50 Hz Dielectric strength between open contacts 1 kV / 1 min / 1 mA / 50 Hz Insulation Rated Insulation voltage (IEC 60664-1) 250 V Insulation coordination (IEC 60664-1) Overvoltage category III; pollution degree 2; up to 2000 m above sea level Rated impulse voltage (IEC 60664-1) 4 kV (1.2/50 µs) Clearance / Creepage distances (IEC 60664-1) 3 mm / 3.2 mm Dielectric strength (EN-61812-1) 2.5 kV / 1 min / 1 mA / 50 Hz Insulation Resistance (NFC 93 050) > 500 MOhms / 250 Vc / 1 min General specifications Status indication (LED) Un: green LED blinks when count, flash when waiting Y1, continuous ON when supplied R: yellow LED blink when only R2 is ON (instantaneous), continuous ON when the 2 relays are ON. Casing 35 mm Mounting Mounting base-mounted on socket Housing material (UL94) Enclosure plastic type V0 Degree of protection (IEC 60529) IP40 Operating temperature (IEC 60068-2) -20 °C to +60 °C
| 3 | 10 /2018 | P lug-In Timer PU2R10MV1 PA2R10MV1 PC2R10MV1 PL2R10MV1 Storage temperature (IEC 60068-2) -40 °C to +70 Humidity (IEC 60068-2-30) 93 % without condensation Vibration resistance (IEC 60068-2-6) ±0.15mm from 10 Hz…60 Hz 2 g from 60 Hz..150 Hz Shock resistance (IEC60068-2-27) 10 gn - 11 ms; 3 X 6 axis (Output non-energized) 5 gn - 11 ms; 3 X 6 axis (Output energized) Drop to concrete floor (IEC 60068-2-32) High: 0.75 m Weight 90 g 110 g with packaging Standards CEE Directive: 2014/30/EU 2014/35/EU EMC Low voltage Approvals / Marking CE cULus Listed Industrial Control Equipment Security standard (IEC 60664-1) Insulation coordination for equipment within low-voltage systems Conformity with environmental directives: 2015/863/UE 2012/19/UE RoHS Reach WEEE Product standard (IEC 61812-1 / UL 60947-4-1) Specified time relays for industrial use Industrial Control Equipment (NRNT- Industrial Control Switches) Refer to UL840 Insulation Coordination for Electrical Equipment Electromagnetic compatibility: IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 Generic standards Immunity for industrial environment Emission residential environment Emission industrial environment Immunity to electrostatic discharges (IEC61000-4-2) Level III Air ±8 KV / Contact ±6 KV Immunity to radiated, radio-frequency, electromagnetic field (IEC61000-4-3) Level III V/m (80 MHz to 1 GHz) 80 % AM (1 kHz) V/m (1.4 to 2 GHz) 80 % AM (1 KHz) V/m (2 to 2.7 GHz) 80 % AM (1 KHz) Immunity to rapid transient bursts (IEC 61000-4-4) direct ±4 kV 5/50 T r/Th ns 5 KKz & 100 KHz Capacitive coupling clamp ± 2 KV 5/50 T r/Th ns 5 KHz & 100 KHz Immunity to shock waves on power supply (IEC 61000-4-5) Level III: line-to-earth ±2 kV / line-to-line ±1 kV Immunity to radiofrequency in common mode (IEC 61000-4-6) Level III: 10 Vrms (0.15 to 80 MHz) 80 % AM (1 kHz) Immunity to voltage dips and breaks (IEC 61000-4-11) % residual voltage during 1 cycle (Crit. B) % residual voltage / 10 cycles 50 Hz / 12 cycles 60 Hz (Crit. C) % residual voltage / 25 cycles 50 Hz / 30 cycles 60 Hz (Crit. C) Short interruptions: % residual voltage / 250 cycles 50 Hz / 300 cycles 60 Hz (Crit. C) AC/DC main port emissions (IEC 61000-6-3 IEC 61000-6-4) CISPR 16-2-1 (4.3) 0.15 MHz – 0.5 MHz, 66 dB(μV) – 56 dB(μV) quasi-peak, 56 dB(μV) – 46 dB(μV) average 0.5 MHz – 5 MHz, 56 dB(μV) quasi-peak, 46 dB(μV) average MHz – 30 MHz, 60 dB(μV) quasi-peak, 50 dB(μV) average CISPR 14-1 0.15 MHz – 30 MHz CISPR 16-2-1 (4.3) 0.15 MHz – 0.5 MHz, 79 dB(μV) quasi-peak, 66 dB(μV) average 0.5 MHz – 30 MHz, 73 dB(μV) quasi-peak, 60 dB(μV) average Radiated emissions (IEC 61000-6-3 IEC 61000-6-4) CISPR 16-2-3 MHz – 230 MHz, 30 dB(μV/m) Quasi-peak at 10 m 230 MHz – 1 000 MHz, 37 dB(μV/m) Quasi-peak at 10 m Or: 30 MHz – 230 MHz, 40 dB(μV/m) Quasi-peak at 3 m in a semi-anechoic chamber 230 MHz – 1 000 MHz, 47 dB(μV/m) Quasi-peak at 3 m in a semi-anechoic chamber
| 4 | 10/2018 | Plug- In Timer PU2R10MV1 PA2R10MV1 PC2R10MV1 PL2R10MV1 Function Diagrams Basic Time ChartBasic Time Chart Basic Time ChartBasic Time Chart Function A - On-Delay (Delay on make) R2 TIMED A2 function R2 INST A1 function U R1/R2 T T Function Ac - On/Off Delay (Delay on make/break) Function Ad - Delay on Start Function At - Summation time relay Function B - One-Shot Function Bw Function C - Off-Delay (Delay on break) Function D - Symmetrical flashing (OFF Start) Function Di - Symmetrical flashing (ON Start) Function H - Interval Function Ht - Interval summation time relay Function L - Recycler (OFF Start) Function Li - Recycler (ON Start)
| 5 | 10/2018 | Plu g-In Timer Warning: The product information contained in this catalogue is given purely as information and does not constitute a representation, warrantly or any form of contractual commitment. Crouzet Automatismes SAS and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsability of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products. Connections PU2R10MV1, PA2R10MV1, PC2R10MV1 U 5 6 7 111 PL2R10MV1 U R1 R2 5 6 7 111 2 5 PU2R10MV1 PA2R10MV1 PC2R10MV1 PL2R10MV1 Outline dimensions (mm) 35±0.2 13.3±0.2 45.01 ±0.2 ±0.2 PU2R10MV1 PA2R10MV1 PC2R10MV1 PL2R10MV1 Socket RECOMENDED SOCKET