PHA25DW2RP PHA25DW2RPS SSR 240V 15 / 25A (RMS) Characteristics and Ratings Function * Single Pole, Single Throw Normally Open * With Zero Crossing Voltage Switching Circuit * Equipped Heat Sink Standard Futures * Easy Installation with DIN Rail Mounting * Low Noise Switching and Rush Current * Space Save Mounting * High Voltage Isolation Characteristics / Ratings Parameter Symbol PHA15DW2RPPHA15DW2RPS PHA25DW2RP PHA25DW2RPS Unit Output Rated Voltage V(RMS) 240 V A.C. Line Voltage Range V(RMS) 60 to 280 V Operating Frequency f 47 to 63 HZ Maximum Load Current IT(RMS) 15 25 A Non-repetitive One Cycle Surge Current ITSM 150 250 A Minimum Operating Current Iop(RMS) 100 mA Maximum off-state Leakage Current Ileak(RMS) 9.0 mA Maximum on-sate Voltage Drop VT(RMS) 1.6 V Response Time T(rps) 1/2 Cycle + 1mS - Input Control Signal Voltage Range IIN(DC) 4.5 to 30 V Input Current IF(DC) 10 mA Pick-up Voltage PUV 4.5 V Drop-out Voltage DOV 1.0 V Input/Output AC Isolation Voltage (Between Input , Output Terminals and Base) Viso(RMS) 2500 4000 *1 2500 4000 *1 V Capacitance (Between input and output C( i-o) 100 pF Operating Temperature Range Top -30 to +80 °C Storage Temperature Range Tstg -35 to +100 °C *1: When the maximum insulation characteristic is necessary , we recommended the use of the insulation sheet.

(Typical) (Typical) PHA15DW2RP / P HA15DW2RPS (Maximum) (Maximum) PHA25DW2RP / PHA25DW2RPS (Maximum) (Maximum)

PHA15DW2RP OUT LINE DRAWING PHA15DW2RPS OUT LINE DRAWING PHA25DW2RP OUTLINE DRAWING PHA25DW2RP S OUTLINE DRAWING