16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com General Description “PF”-Series AC/DC Switching power supplies has been designed to meet harmonic current distortion. PF series has the 75 W PFC with the peak of 150 W, the 120W PFD with peak of 240W and 240 W PFE with peak of 480 W. They are suitable for motor drive. Application Features Motor drive Input Input Voltage: Input Voltage Range: Input Current: Frequency: Input Frequency Range: Phase: Inrush Current: *1 Leakage Current: AC100-230V AC85-264V 0.9-2.0 A 50/60Hz 47-63Hz Single 18A(max.) at AC100V 40A(max.) at AC230V 1mA(maximum)at 25 0.75mA(maximum) at 25℃,(rated input/output and rated input frequency) 1. Chassis Mount 2. Frameless, Connector Type 3. Low Line Distortion 4. Pulse Load response 5. Designed for peak loads(Doubled for rate output) 6. Power factor correction 7. Cost Effective 8. Harmonic current complies to: IEC 1000-3-2, EN6 1000-3-2 9. Universal input 85-264V 10. EMI designed to meet : FCC part 15-B Class B, EN 5502 Class B, VCCI Class B 11. CE-marked acc. To LVD Options 1. Remote Control(add suffix “–R” or “–RR”) 2. Cover(add suffix “–P”) : * ”-P” model dimension of chassis mount model is the same as “Open Frame “ model 3. 40 cm long wire harness Output Models Characteristic Unit PFD12SX-U1 PFD24SX-U1 PFD36SX-U1 PFD48SX-U1 Output Voltage Vdc 12 24 36 48 Output Current A 10 / 20 5 / 10 3.4 / 6.7 2.5 / Voltage Adjust Range V ± 10% of Rated Output Voltage(at no load within the input range) Ripple & Noise(max)*3 mVpp 300 300 300 300 Rise up time mS 500mS(maximum) at 25℃ and rated input/output Hold up time mS 50mS(minimum) at 25℃ and rated input/output Regulation a. Line Regulation mV 60 120 180 240 b. Load Regulation *3 mV 120 240 360 480 c. Temperature Coefficient *4 °C 0.03%/℃ d. Drift(maximum) *5 mV 75 135 195 255 e. Dynamic Load Regulation (typ.) *6 mV 360 720 1080 1440 f. Recovery Time *6 mS 0.5mS(typical) Efficiency *2 % 76 / 80 79 / 82 80 / 83 80 / 83 Power Factor 0.99 Typ. AC100 [V] / 0.95 Typ. AC230 [V] AACC//DDCC SSWWIITTCCHHIINNGG PPOOWWEERR SSUUPPPPLLYY AACC IINNPPUUTT 8855~~226644 SSIINNGGLLEE CCHHAANNNNEELL OOUUTTPPUUTT

112200 WWAATTTTSS

16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com Conditions: *1 cold start *2 at AC100/230V input, rated output and 25℃ *3 measured by a bayonet probe at the output connector at a 0 to 100MHz bandwidth *4 at -10 to +50°C *5 for 7hour period after 1hour warm-up at 25℃ and rated input/output *6 when output current changed from 50% to 150% of rated output current rapidly at rated input *7 safety approved at 25℃ Environmental Specification Operating Temperature -10 to +50 °C Operating Humidity 20 to 85%/RH(non-condensing) Storage Temperature -20 to +85 °C Storage Humidity 10 to 85%/RH(non-condensing) Withstanding Voltage Primary-Secondary AC3,000V for 1minute Primary-Frame Ground AC2,500V for 1minute Secondary-Frame Ground AC500V for 1minute Isolation Resistance Primary-Secondary-Frame Ground 50M Ω (minimum) by DC500V insulation tester Vibration 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s 2,20minutes' period for 60minutes each along X,Y,Z axes(non- operating) Shock 294m/s 2 Cooling Convection Environmental Agencies Line Conducted Noise Built to meet FCC Part15-B Class B Built to meet VCCI Class B Built to meet EN55022 Class B Line Harmonic Distortion Built to meet IEC61000-3-2 Safety UL: UL60950-1 2 nd edition , IEC950 C-UL: CSA C22.2 No.950 VDE EN60950-1 2006, IEC950, VDE0805 MTBF [H] 258,000 Switching Frequency[kHz] 140(typ.) Function/Protection Over current Protection Current Limiting with automatic recovery Over voltage Protection (≥110% of Rated Output Voltage[V]) output shutdown(to reset, leave 3 minutes after shut- off) Remote Sense not available Remote On/Off option Power Fail Detection not available Series Operation not available Parallel Operation not available Mechanical Dimension [mm] 95W × 220L × 55H Weight g 680g, enclosed type:820g

16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com DDIIMMEENNSSIIOONN DDIIAAGGRRAAMM ((mmmm)) BBLLOOCCKK DDIIAAGGRRAAMM

16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com DERATING CURVE EFFICIENCY CURVE OCP CURVE