PFCU390HPX07 SYNQOR | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 17

Technical content

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 1 Power Factor Correction Half-brick PFCU390HPx07 Power Factor Correction Module PFCU390HPC07SRS-G POWER FACTOR CORRECTION 100-240Vrms 390Vdc 700W 47 - 63Hz / 360 - 800Hz The PFCQor® Power Factor Correction module is an essential building block of an AC-DC power supply. Used in conjunction with a hold-up capacitor, SynQor’s high efficiency DC- DC converters and SynQor’s AC line filter, the PFCQor will draw a nearly perfect sinusoidal current (PF>0.99) from a single phase AC input. The PFCQor is capable of being paralleled for higher power levels. The module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation environments. * The label shows a narrower input voltage range to be consisitent with labeling requirements of IEC60950-1, Section 1.7 Operational Features

  • Universal input voltage range: 85-264Vrms
  • Universal input frequency range: 45 - 65Hz / 360 - 800Hz
  • Up to 700W output power
  • ≥0.99 Power Factor
  • High efficiency: >96% (230Vrms) >94% (115Vrms)
  • Internal inrush current limit
  • Auxiliary 10V bias supply
  • Can be paralleled with current sharing
  • Compatible with SynQor DC-DC converters & AC line filters Control Features
  • PFC Enable
  • Load Enable (also: Power Out Good signal)
  • AC Power Good Signal
  • Clock synchronization
  • Output current monitor / Active current sharing Protection Features
  • Input current limit and auto-recovery short circuit protection
  • Auto-recovery input under/over-voltage protection
  • Auto-recovery output over-voltage protection
  • Auto-recovery thermal shutdown Safety Features
  • Input/Output to baseplate isolation 2150Vdc
  • UL 60950-1:2007
  • CAN/CSA-C22.2 No. 60950-1:2007
  • EN60950-1/A12:2011
  • CE Marked 85-264Vrms* 47 - 63Hz / 360 - 800Hz 390Vdc 700W ≥0.99 Up to 96% Input Voltage Input Frequency Output Voltage Output Power Power Factor Full Load Efficiency Mechanical Features
  • Industry standard half-brick pin-out
  • Total weight: 4.9 oz (139 g)
  • Flanged baseplate version available Compliance Features (With SynQor AC Line Filter)
  • EN55011 and EN55022, FCC
  • EN61000-3-2
  • EN61000-3-3

Contents

Page No.

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 2 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 Technical Specification L1IN L1 +VIN +VIN +Vout +Vout GND ENABLE ON/ OFF ON/ OFF CHold-Up CLK Sync Load ENA Trim PFC ENA AC Good +Sense IMON AUX -Sense L1OUT L2/NIN L2/N -VIN -VIN -Vout -VoutL2/NOUT SynQor AC Line Filter SynQor DC-DC Converter SynQor DC-DC Converter Isolated AC Good SynQor PFC Module +Vout Trim +Sense -Sense -Vout MOV1 TVS1 CY1 CY2 CY3 CY4 Typical Application of the PFC Module Typical Application of the PFCQor module to create a multiple-ouput AC-DC Power Supply F1: 10A / 250V Fuse MOV1, TVS1: Must prevent peak voltage from exceeding 575V during all transients. F2, F3 : Use fuse recommended in converter specification CHold-Up: 100 - 1,000 μF (Dependent on Power Level and Line Frequency) CY1-Y4: See “EMI Considerations” in application notes Suggested Parts: F1: 250VAC, 10A; Littelfuse 0216010.MXEP MOV1: 300VAC, 60J; EPCOS S10K300E2 TVS1: 400V, 3J; Use two VISHAY 1.5KE200CA devices connected in series CHold-Up: 450V, 390uF; United Chemi-Con ELXS451VSN391MR50S CY1, CY3: 3.3nF, 500VAC; Vishay VY1332M59Y5UQ6TV0 CY2, CY4: 10nF, 300VAC; Vishay VY2103M63Y5US63V7

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 3 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 PFCU390HPx07 Electrical Characteristics Operating conditions of 115Vrms, 60Hz input, 700W output, 390uF bulk capacitance, and baseplate temperature = 25°C unless otherwise noted; full operating baseplate temperature range is -40 °C to +100 °C with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions ABSOLUTE MAXIMUM RATINGS Input Voltage (L1 to L2/N) Operating Continuous 264 Vrms

375 Vpk

Transient (≤100ms ) 290 Vrms

410 Vpk

575 Vpk

Isolation Voltage (Input / Output to Baseplate) 2150 Vdc Operating Temperature -40 100 °C Baseplate temperature Storage Temperature -45 125 °C Voltage at AC GOOD and LOAD ENA pins -0.3 16 V Relative to Vout- pin Current drawn from AUX pin 0 10 mADC Voltage at PFC enable pin -2 575 V Relative to Vout- pin Voltage at CLK SYNC In -2 5.5 V Relative to Vout- pin INPUT CHARACTERISTICS (L1 to L2/N) Operating Input Voltage Range AC Input Continuous 85 264 Vrms AC Input 100ms Transient 40 290 Vrms Available output power reduced when <85 Vrms Input Under-Voltage Lockout 30 Vrms >1s Duration Operating Input Frequency 50/60Hz 45 65 Hz 400Hz 360 800 Hz Power Factor of AC Input Current 0.99 50/60Hz 0.97 400Hz, min 400W output Total Harmonic Distortion of AC Input Current 3 % Inrush of AC Input Current 10 A

25 A 230V, 400Hz

Enabled AC Input Current (no load) 50 80 mArms Disabled AC Input Current 30 50 mArms Maximum Input Power 775 W Vin >85Vrms Maximum Input Current 9.5 Arms 85 VAC in OUTPUT CHARACTERISTICS Output Voltage Set Point 385 390 395 Vdc Vin <240 Vrms, see figure 10 Output Voltage Regulation Over Line ±0.3 % Vin <240 Vrms, see figure 10 Over Load ±2 % Over Temperature ±1.5 % Total Output Voltage Range: Input Voltage within Continuous Range 380 395 Vdc Vin <240 Vrms, see figure 10 Input Voltage within Transient Range 365 430 V Input Voltage Brownout/Dropout 200 395 V See application section Output Voltage Ripple and Noise 60Hz, see Note 1 Peak-to-Peak 10 V Dependent on Hold-up capacitor RMS 4 V Operating Output Current Range 0 1.8 A Output Over-Voltage Shutdown Threshold 420 460 V Output (Hold-up) Capacitance 100 1,000 µF See Note 2 Output Common-Mode Capacitance 20 nF See “EMI Considerations” in application notes Efficiency 50% Load 94 % See Figure 1 for efficiency curve 100% Load 95 % See Figure 1 for efficiency curve Note 1: 300 µF electrolytic hold-up capacitor having a typical ESR of 0.5Ω. More capacitance/Lower ESR will reduce the line frequency ripple. Note 2: The PFCQor is able to operate with a minimum of 100uF of hold-up capacitance but SynQor recommends at least 330uF if the power system will be required to conform to lightning surge standards. This is because the PFCQor relies on the hold-up capacitor to absorb the energy from a lightning surge. Technical Specification

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 4 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 PFCU390HPx07 Electrical Characteristics (continued) Operating conditions of 115Vrms, 60Hz input, 700W output, 390uF bulk capacitance, and baseplate temperature = 25°C unless otherwise noted; full operating baseplate temperature range is -40 °C to +100 °C with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions DYNAMIC CHARACTERISTICS Turn-On Transient Start-up Inhibit Time 10 ms Turn-On Time 2 s Output Voltage Overshoot 0 % ISOLATION CHARACTERISTICS (Input/output to baseplate) Isolation Voltage 2150 V Isolation Resistance 100 MΩ Isolation Capacitance 100 pF TEMPERATURE LIMITS FOR POWER DERATING CURVES Semiconductor Junction Temperature 125 °C Board Temperature 125 °C Transformer Temperature 125 °C Maximum Baseplate Temperature, Tb 100 °C FEATURE CHARACTERISTICS Output Precharge Output Current 100 mA Output Short-Circuit Withstand indefinite s Free Running Switching Frequency 200 kHz Each of 4 interleaved phases Clock Synchronization Input (CLK SYNC) Frequency Range 150 250 kHz Logic Level High 2 V Logic Level Low 0.8 V Duty Cycle 20 80 % PFC Enable (PFC ENA) V Off-State Voltage 2 On-State Voltage 0.8 Internal Pull-Up Voltage 5 Vpk Internal Pull-Up Resistance 10 kΩ AC Good (AC GOOD) AC Input Voltage for AC Good 119 375 Vpk AC Good State 0 0.4 V AC Not Good State 15 V Open Collector Maximum Sink Current 300 mA Load Enable (also: Output Power Good) (LOAD ENA) Enable (Good) State 0 0.4 V Disable (Not Good) State 15 V Open Collector Maximum Sink Current 300 mA Output Voltage for Load Enable (Good) State Rising / Startup 360 V Falling / Shutdown 200 V Over-Temperature Trip Point 130 °C At internal PCB Auxiliary Bias Supply Voltage Range (≤3 mA Load) 7 11 V Maximum Source Current 10 mA DC Equivalent Series Resistance 1 kΩ RELIABILITY CHARACTERISTICS Calculated MTBF (Telcordia) TR-NWT-000332 2.5 106 Hrs. Tb = 70°C Calculated MTBF (MIL-217) MIL-HDBK-217F 2 106 Hrs. Tb = 70°C Field Demonstrated MTBF 106 Hrs. See our website for details Technical Specification

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 5 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 100 0 100 200 300 400 500 600 700 Efficiency (%) Output Power (W)

115 Vin

230 Vin

90 Vin

0 100 200 300 400 500 600 700 Power Dissipation (W) Output Power (W) 0.5 1.5 2.5 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 Amplitude (% of fundamental current) Overtone # PFCQor EN 61000-3-2* MIL-1399 MIL-461 CE101 0.5 1.5 2.5 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 Amplitude (% of fundamental current) Overtone # PFCQor EN 61000-3-2* MIL-1399 MIL-461 CE101 Technical Specification Figure 1: Efficiency at nominal output voltage vs. load power for 90Vrms, 115Vrms and 230Vrms (60Hz) input voltage at Tb = 25°C. Figure 2: Power dissipation at nominal output voltage vs. load power for 90Vrms, 115Vrms and 230Vrms (60Hz) input voltage at Tb = 25°C. Figure 3: Typical Input Voltage and Current waveforms at fullrated power (115Vrms, 60Hz) Yellow: Vin (100V/div), Green: Iin (5A/div), Timebase: (5ms/ div). Figure 4: Typical Input Voltage and Current waveforms at full rated power (115Vrms, 400Hz). Yellow: Vin (100V/div), Green: Iin (5A/div), Timebase: (1ms/div). Figure 5: Frequency spectrum of input current at full rated power (115Vrms, 60Hz). Figure 6: Frequency spectrum of input current at full rated power (230Vrms, 60Hz).

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 6 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 100 200 300 400 500 600 700 800 0 20 40 60 80 100 120 Power Output (W) Base Plate Temperature ( ºC)

85 Vac

100 Vac

115 Vac

180 Vac 375 380 385 390 395 400 405 410 415 420 425 430 435 85 110 135 160 185 210 235 260 285 Output Voltage (V) Input Voltage (Vrms) Max Typical Min Technical Specification Figure 7: Output voltage with 500μF Hold-up capacitor at full rated power (115V AC, 60Hz) Red: Vout (10V/div), Timebase: (5ms/div) Figure 8: Output voltage startup waveform (115V AC, 60Hz) Red: (100V/div), Timebase: (500ms/div) Figure 9: Output power vs. baseplate temperature derating curve Figure 10: DC output voltage range vs. input voltage

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 7 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 Standards & Qualification Testing Parameter Notes & Conditions STANDARDS COMPLIANCE UL 60950-1:2007 Basic Insulation to Baseplate CAN/CSA-C22.2 No. 60950-1:2007 EN60950-1/A12:2011 CE Marked Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website. Parameter # Units Test Conditions QUALIFICATION TESTING Life Test 32 95% rated Vin and load, units at derating point, 1000 hours Vibration 5 10-55 Hz sweep, 0.060” total excursion, 1 min./sweep, 120 sweeps for 3 axis Mechanical Shock 5 100g minimum, 2 drops in x,y and z axis Temperature Cycling 10 -40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles Power/Thermal Cycling 5 Toperating = min to max, Vin = min to max, full load, 100 cycles Design Marginality 5 Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load Humidity 5 85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day Solderability 15 pins MIL-STD-883, method 2003 EMC CHARACTERISTICS (With SynQor AC Line Filter) Conducted emissions EN55011 and EN55022, FCC PART 15 Line frequency harmonics EN61000-3-2 Voltage fluctuations EN61000-3-3 ESD air EN61000-4-2 Radiated immunity EN61000-4-3 Fast transients EN61000-4-4 Line surge immunity EN61000-4-5 Conducted immunity EN61000-4-6 Power freq. mag. field EN61000-4-8 Voltage dip immunity EN61000-4-11 Standards Compliance, Qualification Testing & EMC Characteristic

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 8 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 BA SI C OPE RA T I ON A N D FE A TU RE S The PFCQor power factor correction module is an essential building block of an overall high power AC -DC power supply. As shown in Fig. A, a typical power supply would be comprised of a SynQor AC Line Filter, a SynQor PFCQor module, an energy storage hold -up capacitor and one or more SynQor DC -DC converters, depending on how many output voltages are required. Fuses are needed in various places to meet safety requirements. The primary purpose of the PFCQor is to shape the input current that is drawn from a single -phase sinusoidal AC source into a nearly perfect sinusoidal waveform so that the AC-DC power supply will present a very high power factor load (PF > 0.99) to this source. In doing this wave-shaping, the PFCQor ensures that the harmonic components of the AC current waveform are well below the levels called for in EN61000-3-2. The total harmonic distortion of the AC current waveform is less than 8%. The PFCQor accomplishes its wave -shaping task by first rectifying the filtered AC source voltage, and then processing the input power through a non -isolated, high -efficiency, high-frequency “boost converter” that both gives the input AC current its sinusoidal shape and provides a regulated DC voltage across the hold-up capacitor. The hold -up capacitor handles the cyclic imbalance between the flow of energy drawn from the AC source and the flow of energy delivered to the DC-DC converters. This energy imbalance has a cyclic frequency twice that of the AC source voltage (e.g. 120Hz for a 60Hz input). This relatively low frequency makes the hold -up capacitor relatively large. Another purpose of the hold-up capacitor is to be a source of energy so that the DC-DC converters can continue to deliver load power during a temporary brownout or dropout of the AC source. A typical power supply will have sufficient hold- up capacitor to give a “hold-up time” in the 20ms range, but longer times can b e achieved with yet more hold -up capacitance. Besides shaping the AC current waveform, the PFCQor performs several other important functions. At start -up it controls the level of inrush current drawn from the AC source to charge the hold-up capacitor. It limits the DC current that can be drawn from its output and it will shut-down if a short circuit appears across the output. It will also shut-down if the AC input voltage is out of its range (either too high or too low) for too long, or if the temperature of the module is too high. In addition, the PFCQor has several input and output control signals that include PFC_ENABLE, LOAD_ENABLE , (which doubles as a POWER_OUT_GOOD signal), AC_GOOD, CLOCK SYNCHRONIZATION, and OUTPUT CURRENT MONITOR. All of these signals are described in more detail below. There is also an auxiliary bias supply that can be used to power a low power control circuit at the output of the PFCQor. STARTUP SEQUENCE When the AC source voltage is first applied, regardless of whether the PFC Qor is enabled or disabled through its PFC_ENABLE pin, the PFCQor will pre -charge the output hold-up capacitor with a current limited to approximately 100mA. This pre -charging continues until the output voltage is within approximately 10V of the peak volta ge of the AC source. If, at this time, the PFC_ENABLE input is logically high, and the PFCQor is therefore disabled, the PFCQor will remain in this pre -charged state indefinitely. NOTE: During both this pre-charging time and for whatever time afterwards that the PFCQor remains disabled it is essential that all the load converters connected to the output of the PFCQor be disabled so that the total load current seen by the PFCQor is only a small fraction of the 100mA charging current. To help facilitate this requirement, the PFCQor’s LOAD_ENABLE output can be used to disable the load converters. When the PFC_ENABLE input pin is pulled low, and after the pre-charging is completed if it is not already, the boost converter within the PFCQor will start operating and the PFCQor’s output voltage will be increased to its nominal regulated value. After this regulated voltage level is achieved, the PFCQor will provide a logical low signal on its LOAD_ENABLE output pin. This signal should be used to enable the load converters so that they can begin to draw power from the PFCQor. If the PFC_ENABLE input is de -asserted (pulled high or allowed to float), the boost converter in the PFCQor will shut down and the LOAD_ENABLE output pin will return to a logic high. This will then disable the load converters. NOTE: The voltage across the hold-up capacitor will remain in a charged state after the PFCQor is disabled as long as the AC source voltage is present. Application Section

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 9 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 BR OW N O UT/D R OPO UT SE QU EN C E If the AC source voltage falls below the PFCQor’s specified continuous minimum input voltage, the AC_Good output will de -assert (it will become a logic high), although the PFCQor will continue to operate as described below. This AC_Good output signal can b e used as a warning signal to permit a graceful shutdown of the load after some period of time that depends on the size of the hold-up capacitor. If the AC source voltage is present but it is below its continuous minimum input voltage limit, the PFCQor wil l still draw whatever power it can (within its current limits) from the AC source. This power may not be enough for the total load power, in which case the hold -up capacitor will provide the balance of the power. The voltage across the hold- up capacitor will therefore drop as it discharges. If the AC source voltage drops below its specified transient minimum input voltage limit, the PFCQor’s boost converter will shut down and no longer deliver power to the output. Under this condition, all of the load power will be drawn from the hold-up capacitor. If and when the voltage across the hold-up capacitor drops below its specified minimum limit, the LOAD_ENABLE output will be de -asserted to a logic high. Besides disabling the load converters, this condition will cause the PFCQor to return to the beginning of the STARTUP SEQUENCE described above. NOTE: Regardless of what happens to the PFCQor’s output voltage under a brownout or dropout condition, if the AC source voltage drops below its rated under-voltage value for 1 second or more, the PFCQor will shut down. N OT E : During the first phase where the hold -up capacitor is recharged (if it this phase exists) there will be an inrush current drawn from the AC source that depends on the details of how quickly the AC source vol tage returns to its normal operating condition. AC_Good CONTROL FEATURES Auxiliary Bias Power Supply (Pin 6): The circuit shown below is an effective model for the AUX bias power supply: The purpose of the AUX power supply is to provide a low level of power to control circuitry at the output of the PFCQor, such as the circuits shown earlier in this section. The AUX power supply is present and regulated whenever the PFCQor’s output voltage is greater than approximately 75V. The AUX bias power supply is unspecified when PFCQor’s output voltage is less than about 75V (it may, for instance, come and go as the output voltage rises on its way to 75V). PFC_ENABLE (Pin 3):

  • If this input is floating or tied high the PFCQor’s boost converter is disabled and the LOAD_ENABLE output signal is de-asserted high.
  • If this input is pulled low the PFCQor’s boost is enabled after the pre -charger has charged the voltage across the hold-up capacitor to within approximately 10 volts of the peak of the AC source voltage. Application Section

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 10 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 LOAD_ENABLE (also: POWER OUT GOOD signal) (Pin 7):

  • When the LOAD_ENABLE pin is internally pulled LOW the load converters are permitted to draw power from the PFCQor’s output.
  • When the LOAD_ENABLE floats all load converters should disabled.
  • The LOAD_ENABLE can be tied directly to the ON/OFF control pins of SynQor’s DC -DC converters as shown in Figure A.
  • For loads that are not SynQor DC-DC converters and that do not otherwise have a way to be enabled/disabled, an external power MOSFET can be used to connect and disconnect these loads from the PFCQor’s output based on the status of the LOAD_ENABLE signal, as shown below.
  • For high-side or remotely switched loads, an optoisolator can be employed as shown below. AC_GOOD (Pin 8): PFCQor
  • The AC_GOOD signal is internally pulled low whenever th e AC sourc e voltage is within the PFCQor’s continuou s operating range for at least one cycle of the source waveform, regardless of whether the PFCQor is enabled or disabled.
  • When the peak of the AC source voltage is outside thiscontinuous operating range (either too high or too low), the AC_GOOD pin will float.
  • The AC GOOD signal is typically used with a pullup resistor and an opto-coupler (as shown in Fig. A) to provide an isolated signal to the load that the AC source voltage is no longer within the specified continuous operating range. If this condition persists, the load power can only be delivered for the “hold-up time”, and it may therefore be desirable to have the load gracefully shut down. The AC GOOD signal provides a warning for this action to be taken . When the AC source voltage returns to the specified continuous operating range, the AC GOOD signal will re-assert after a 100 ms delay.
  • The AC_GOOD pin is valid whenever the AUX bias supply power is valid (see above). Output Current M o nitor (Pin B):
  • The IMON signal monitors the DC average output current, line-frequency components are removed from IMON.
  • The IMON output voltage is 0V at no -load and increases linearly to 2V at full-load.
  • Any monitoring of thi s output should be accomplished with a high input impedance sensor as this pin is also used for current sharing, see below. Application Section

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 11 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 Clock Synchronization (Pin 2):

  • The PFCQor performs optimally with a 200kHz switching frequency. Deviation from this frequency will result in a reduction of maximum output power. Consult factory for details. PRO TEC T ION FEATU RES Input O ver - & U nd er-Voltage: If a brownout or dropout of the AC source voltage occurs, and if it lasts long enough for the PFCQor’s output voltage to drop below its specified minimum limit, the PFCQor will shut down. Furthermore, regardless of what happens to the PFCQor’s output voltage, if the AC source voltage drops below its rated under - voltage value for 1 second or more, the PFCQor will shut down. After any shutdown the PFCQor will automatically return to the beginning of the STARTUP SEQUENCE described above. Output O ver -Voltage: If the output voltage exceeds its specified maximum limit, the PFCQor’s boost converter will shutdown. However, under this condition the PFCQor’s pre-charge circuit will continue to deliver 100mA of current to the output whenever the AC source voltage is higher than the dc output voltage. Care must be taken to insure this condition does not allow the output voltage to rise high enough to damage the PFCQor or the load converters . Output Current Limit & Short -Circuit Shutdown: If the PFCQor’s output is overloaded such that its output current limit becomes activated, the output voltage will fall as the excess load current discharges the hold-up capacitor. The PFCQor will continue to deliver power into this overload condition for 100 ms, after which the unit will shut down and automatically return to the beginning of the STARTUP SEQUENCE described above. If at any point the output voltage falls below the peak of the AC source voltage, the PFCQor will immediately shut down and return to the STARTUP SEQUENCE. Ov er Tempera tur e: If the internal temperature of the PFCQor reaches 130 °C the PFCQor will turn off its boost converter. The LOAD_ENABLE output will simultaneously be de -asserted high. When the internal temperature falls below 110°C, the PFCQor will return t o the beginning of the STARTUP SEQUENCE described above. ENER GY STORAGE HOLD -UP CAPACI TOR The hold-up capacitor performs two fu nctions:
  • It handles the cyclic imbalance between the flow of energy drawn from the AC source and the flow of energy delivered to the DC-DC converters. In doing so, the voltage across the hold-up capacitor has a ripple at a frequency twice that of the AC source voltage (e.g. 120Hz for a 60Hz input). The larger the hold-up capacitor, or the higher the frequency of the AC source, the smaller this ripple will be.
  • It provides a source of energy so that the DC-DC converters can continue to deliver load power during a te mporary brownout or dropout of the AC source. The larger the hold-up capacitor the longer it can provide this energy. Often it will be made large enough to allow the load to be gracefully shutdown after the AC source has been outside of its normal range for a set amount of time. A typical “hold -up time” would be in the 20 ms range for a 50/60 Hz system. The total energy stored in a hold -up capacitor having capacitance C at any given voltage V is: E = ½CV2 The amount of energy, ∆E, which can be drawn fr om this capacitor depends on the capacitor’s starting voltage, Vs, and its final voltage, Vf, where V s is the PFCQor’s nominal regulated output voltage and Vf is the PFCQor’s minimum output voltage limit. This energy equals the amount of power, P, which th e DC-DC converters draw from the hold-up capacitor times the length of time, ∆t, which it takes for the hold -up capacitor’s voltage to drop from Vs to Vf. This energy can be equated to the hold-up capacitance according to the following formula: Δ∆E = P Δ∆t = ½C( Vs2- Vf2) Application Section

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 12 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 This formula can be rearranged to find the minimum required value for C to provide the hold-up time desired for a given power level (note: this power level P is not the load power, but rather the load power divided by efficiency of the DC-DC converters): Cmin = 2P Δ∆t ⁄ ( Vs2- V f2) For example, i f we assume P = 600W, ∆t = 20ms, V s = 390V and Vf = 200V, then we would want a hold -up capacitance of at least 2 15µF. During the start-up sequence the PFCQor will pre-charge the hold-up capacitor with approximately 100mA of current until it has reached a voltage about 10V below the peak of the AC source voltage. The time it takes for this to occur can be calculated using the following formula: t = CV/10 0mA For example, if the AC source voltage is 230Vrms (Vpk = 325V) and the hold -up capacitor is 200µF, this length of time will be approximately 0.6 seconds. The larger the hold -up capacitor, the longer it will take . After the hold-up capacitor’s voltage has reached this level, and assuming the PFCQor has been enabled, the boost converter in the PFCQor will quickly charge the hold -up capacitor to the nominal regulated output voltage level. N OT E : The PFCQor is able to operate with a minimum of 100uF of hold-up capacitance, but Synqor recommends at least 330uF if the power system will be required to conform to lightning surge standards. This is because the PFCQor relies on the hold -up capacitor to absorb most of the energy from a lightning surge. N OT E : Even though the PFCQor limits the inrush current drawn from the AC source during its STARTUP SEQUENCE, it will not necessarily limit this current at the end of a temporary brownout or dropout of the AC source when the hold -up capacitor’s voltage has not dropped below its minimum output voltage limit. In such a condition the PFCQor will not reinitiate a STARTUP SEQUENCE and it will therefore not limit the current flowing through it. If the peak of the AC source voltage is greater than the hold-up capacitor’s voltage at the end of the brownout/dropout period, there will be a large inrush current for one half-cycle as the hold-up capacitor’s voltage is charged up to the peak of the AC source voltage. The larger the hold-up capacitor the larger this inrush current will be. To keep this inrush current within a reasonable limit, the maximum capacitance of the hold-up capacitor is limited as specified in the Technical Specifications table. If it is desired to have a ho ld-up time longer than can be achieved with this maximum specified hold-up capacitance, then the circuit shown below can be used. In this circuit the total hold-up capacitance is (C1 + C2), and it can be made as large as desired as long as C1 does not exceed the maximum capacitance specified in the Technical Specifications table. The resistor, Rc, in series with C2 is present to limit the current that will charge this capacitor after a temporary brownout/dropout event. Its resistance should be large enough to limit the charging current to a fraction of the PFCQor’s rated output current. The diode in parallel with the resistor permits the load converters to draw whatever energy they need from C2 without being hindered by the resistor.: Output Ripple Cons idera tio ns: The hold-up capacitor must have a ripple current rating high enough to withstand the ripple current generated on the output of the PFCQor. Ripple current amplitude is dependent only upon the total PFCQor output power, P DC, and the operating out put voltage V O. It can be calculated using the following formula: The AC line frequency, fac, bulk capacitance, C, operating output voltage, and output power will determine the amplitude of the voltage ripple present on the output of the PFCQor. It can be calculated with: For example, to calculate voltage and current ripple for a PFCQor with a 700W output, 500uF hold -up capacitor, and a 60Hz fundamental AC line frequency: In this case, the hold-up capacitor would require a minimum ripple current rating of 1.3Arms, and the output voltage would have a pk-pk ripple voltage of 9.6V. Application Section

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 13 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 SAFET Y NOT ES The output of the PFCQor is not isolated from the AC source, and it is therefore a hazardous voltage. Care must be taken to avoid contact with this vo ltage, as well as with the AC source voltage. The PFCQor must have a fuse in series with its AC source. The rating for this fuse is given in the Technical Specification table. If multiple PFCQors are paralleled, there should be a fuse for each PFCQor. THERMAL CONSIDER AT IO N The maximum operating base -plate temperature, T B, is 100 ºC. Refer to the thermal derating curves to see the allowable power output for a given baseplate temperature and input voltage. A power derating curve can be calculated for any heatsink that is attached to the base -plate of the converter. It is only necessary to determine the thermal resistance, R THBA, of the chosen heatsink between the base -plate and the ambient air for a given airflow rate. The following formula can then be used to determine the maximum power the converter can dissipate for a given thermal condition: This value of power dissipation can then be used in conjunction with the data shown in the figures to determine the maximum load power that the converter can deliver in the given thermal condition. AC LINE FILT ER An AC line filter is needed to attenuate the differential - and common-mode voltage and current ri pples created by the PFCQor, the DC -DC converters and the load such that the system will comply with EMI requirements. The filter also provides protection for the PFCQor from high frequency transients in the AC source voltage. SynQor has a family of AC line filters that will provide these functions. It is recommended that a metal-oxide varistor (MOV) be placed from line-to-line on the input of the filter, and a TVS diode be placed from line-to- line on the output of the filter in order to keep the PFCQor input voltage from exceeding 575V during all transients. See Figure A for suggested parts. If a non-SynQor AC line filter is used, the use of an MOV on the input and a TVS diode on the output of the filter is still recommended. EMI CONSIDERATIONS To meet va rious conducted line emission standards, additional Y -capacitors may be needed to attenuate common - mode noise. Syn Qor recommends that saftey -rated ceramic capacitors be placed across any isolated DC -DC converters on the output of the PFC from Vin - to Vout - and Vout - to ground. However, the total capacitance from the PFC output leads to earth ground should not be more than 20n F if one of the PFC input leads is connected to earth ground. See “Typical Application of the PFC Module” (Figure A) for a diagram and suggested parts. In higher power applications, multiple units can be used in parallel as shown below.

  • To balance load currents evenly between PFCQor modules, a 0.1 ohm resistor must be placed in series with Vout - on each module. The parallel diagram below shows correct placement of the resistors in relation to other circuitry. Resistors must be rated to handle RMS load return current.
  • PFC_ENABLE may be driven with a common signal, but a 100 ohm resistor should be placed in series with each input before being connected to the common node.
  • AUX Bias outputs can be directly connected together as shown.
  • AC_GOOD can drive a common signal, but a 100 ohm resistor should be placed in series with each output before being connected to the common node.
  • The loads should only be enabled when all the individual LOAD_ENABLE outputs have been asserted low. The circuit shown below combines the individual LOAD_ENABLE outputs into a single master LOAD_ENABLE to achieve this requirement.
  • Active current sharing is accomplished by connecting all IMON pins directly together. The voltage at the IMON pins is then indicative of the average output cur rent. Again, any circuit used to monitor the IMON voltage should have high input impedance. Application Section

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 14 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 PARALLEL DIAGRAM Application Section

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 15 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 Standard Mechanical Diagram Mechanical Diagrams 1.900 [48.26] 0.400 [10.16] 0.800 [20.32] 1.000 [25.40] 1.400 [35.56] 0.700 [17.78] SEATING PLANE HEIGHT 0.512 0.005 13.00 0.12[ ] PIN EXTENSION 0.163 [4.14] BOTTOMSIDE CLEARANCE 0.027 0.010 0.69 ][ 52.0 2.486 [63.14] 2.000 [50.80] 2.386 [60.60] 1.900 [48.26] 0.01 [0.3] 0.30 [7.6] TOP VIEW 12B34 5 6 7 8 9 0.004 [0.10] THRU HOLE STANDOFFS SEE NOTE 1 (4 PLCS) NOTES 1)Applied torque per screw should not exceed 6in-lb. (0.7 Nm). 2)Baseplate flatness tolerance is 0.004” (.10 mm) TIR for surface. 3)Pins 1-4, 6-8, and B are 0.040” (1.02mm) diameter, with 0.080” (2.03mm) diameter standoff shoulders. 4)Pins 5 and 9 are 0.080” (2.03 mm) diameter with 0.125” (3.18 mm) diameter standoff shoulders. 5)All Pins: Material - Copper Alloy; Finish - Matte Tin over Nickel plate 6)Undimensioned components are shown for visual reference only. 7)Weight: 4.9 oz (139 g) 8)Threaded and Non-Threaded options available 9)All dimensions in inches (mm). Tolerances: unless otherwise noted. 10)Workmanship: Meets or exceeds IPC-A-610C Class II PIN DESIGNATIONS Pin Name Function

1 L1 AC Line 1

2 CLK SYNC Clock Synchronization Input

B IMON Output Current Monitor / Current Share

3 PFC ENA Negative Logic PFC Enable

4 L2/N AC Line 2 / Neutral

5 -VOUT Negative Output Voltage

6 AUX Auxiliary Bias power supply

7 LOAD ENA Negative Logic load enable and power out good signal

8 AC GOOD Negative Logic AC Good signal

9 +VOUT Positive Output voltage

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 16 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 Flanged Mechanical Diagram PIN EXTENSION 0.180 [4.57] SEATING PLANE HEIGHT 0.495 0.025 12.57 0.63[ ] FLANGE THICKNESS 0.125 [3.18] 0.400 [10.16] 1.400 [35.56] 0.700 [17.78] 1.000 [25.40] 1.900 [48.26] 0.800 [20.32] BOTTOMSIDE CLEARANCE 0.005 0.010 0.13 ][ 52.0 2.386 [60.60] 1.866 [47.40] 1.300 [33.02] 3.150 [80.01] 2.950 [74.93] 2.486 [63.14] 0.31 [7.9] 0.775 0.020 [19.69 0.50] TOP VIEW 124 5 6 7 8 9 3 B .130 [3.30] SEE NOTE 1 (6 PLCS) 0.010 [0.25] NOTES 1)Applied torque per M3 or 4-40 screw should not exceed 6in-lb. (0.7 Nm). 2)Baseplate flatness tolerance is 0.010” (.2mm) TIR for surface. 3)Pins 1-4, 6-8, and B are 0.040” (1.02mm) diameter, with 0.080” (2.03mm) diameter standoff shoulders. 4)Pins 5 and 9 are 0.080” (2.03 mm) diameter with 0.125” (3.18 mm) diameter standoff shoulders. 5)Other Pin extensions lengths available 6)All Pins: Material - Copper Alloy; Finish - Matte Tin over Nickel plate 7)Undimensioned components are shown for visual reference only. 8)Weight: 5.1 oz (145 g) 9)All dimensions in inches (mm). Tolerances: unless otherwise noted. 10)Workmanship: Meets or exceeds IPC-A-610C Class II PIN DESIGNATIONS Pin Name Function B IMON Output Current Monitor / Current Share 5 -VOUT Negative Output Voltage 9 +VOUT Positive Output voltage

Product # PFCU390HPx07 Phone 1-888-567-9596 www.SynQor.com Doc.# 005-0006254 Rev. E 04/07/2016 Page 17 Input: 100-240Vrms Output: 390Vdc Power: Up to 700W PFCU390HPx07 PART NUMBERING SYSTEM The part numbering system for SynQor’s dc-dc converters follows the format shown in the example below. The first 12 characters comprise the base part number and the last 3 characters indicate available options. The “-G” suffix indicates 6/6 RoHS compliance.

ORDERING INFORMATION

The tables below show the valid model numbers and ordering options for converters in this product family. When ordering SynQor converters, please ensure that you use the complete 15 character part number consisting of the 12 character base part number and the additional characters for options. InQor units are only available with 6/6 RoHS compliance indicated by "-G". The following options must be included in place of the w x y z spaces in the model numbers listed above. Not all combinations make valid part numbers, please contact SynQor for availability. Application Notes A variety of application notes and technical white papers can be downloaded in pdf format from our website. RoHS Compliance: The EU led RoHS (Restriction of Hazardous Substances) Directive bans the use of Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor product is 6/6 RoHS compliant. For more information please refer to SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free Initiative web page or e-mail us at rohs@synqor.com. Product Family Package Size Performance Level Thermal Design Output Power 6/6 RoHS Options (see Ordering Information) Input Voltage Output Voltage PFC U 390 H P C 07 N R S - G Level Thermal Design Output Power Input Phases Pin Style Parallel Capability PFC U: 85-264 Vrms 390: 390V H: Half-brick P: Peta C: Encased 07: 700W S: Single-Phase R: 0.180” D: Encased with Non-threaded S: Supports Baseplate Parallel V: Encased with Capability Flanged Baseplate WARRANTY SynQor offers a two (2) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. Contact SynQor for further information and to order: Phone: 978-849-0600 Toll Free: 888-567-9596 Fax: 978-849-0602 E-mail: power@synqor.com Web: www.synqor.com Address: 155 Swanson Road Boxborough, MA 01719 USA PATENTS SynQor holds numerous U.S. patents, one or more of which apply to most of its power converter products. Any that apply to the product(s) listed in this document are identified by markings on the product(s) or on internal components of the product(s) in accordance with U.S. patent laws. SynQor’s patents include the following: 5,999,417 6,222,742 6,545,890 6,594,159 6,731,520 6,894,468 6,896,526 6,927,987 7,050,309 7,072,190 7,085,146 7,119,524 7,269,034 7,272,021 7,272,023 7,558,083 7,564,702 7,765,687 7,787,261 8,023,290 8,149,597 8,493,751 8,644,027 9,143,042