PFC-SX ETA-USA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Features

  1. Designed for peak load (twice rated output) 2. Power Factor Correction 3. Harmonic Current Harmonic current complies to: IEC61000-3-2, EN61000- 3-2 4. Universal Input 85-264Vac 5. EMI designed to meet FCC Part 15-B Class B, EN55022 Class B, VCCI Class B 6. Safety: UL1950, CSA950(C-UL), EN60950 7. Cost effective 8. CE-marked according to LVD 9. Optional Cover Input Input Voltage: Input Voltage Range: Input Current: Frequency: Input Frequency Range: Phase: Inrush Current: *1 Leakage Current: Power Factor Correction: AC100-230V AC85-264V 0.7-1.2 A 50/60Hz 47-63Hz Single 20A(max.) at AC100V 40A(max.) at AC230V 1mA(maximum)at 25 0.75mA(maximum) at 25℃,(rated input/output and rated input frequency) 0.99 at 100Vac 0.95 at 230Vac

75 WATT

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Block Diagram Efficiency Curve

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com PFC**SX Specification OCP Curve Output Models Characteristic Unit PFC12SX-U PFC24SX-U PFC36SX-U PFC48SX-U Output Voltage Vdc 12 24 36 48 Output Current A 6.3 / 12.6 3.2 / 6.4 2.1 / 6.7 1.6 / 3.2 Voltage Adjust Range V ± 10% of Rated Output Voltage(at no load within the input range) Ripple & Noise(max)*3 mVpp 300 300 300 300 Rise up time mS 600mS(maximum) at 25℃ and rated input/output Hold up time mS 50mS(minimum) at 25℃ and rated input/output Regulation a. Line Regulation mV 60 120 180 240 b. Load Regulation *3 mV 120 240 360 480 c. Temperature Coefficient *4 °C 0.03%/℃ d. Drift(maximum) *5 mV 75 135 195 255 e. Dynamic Load Regulation (typ.) *6 mV 360 720 1080 1440 f. Recovery Time *6 mS 0.5mS(typical) Efficiency *2 % 76 / 80 79 / 82 80 / 83 80 / 83 Power Factor 0.99 Typ. AC100 [V] / 0.95 Typ. AC230 [V]

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Conditions: *1 cold start *2 at AC100/230V input, rated output and 25℃ *3 measured by a bayonet probe at the output connector at a 0 to 100MHz bandwidth *4 at -10 to +50°C *5 for 7hour period after 1hour warm-up at 25℃ and rated input/output *6 when output current changed from 50% to 150% of rated output current rapidly at rated input *7 safety approved at 25℃ Environmental Specification Operating Temperature -10 to +50 °C Operating Humidity 20 to 85%/RH(non-condensing) Storage Temperature -20 to +85 °C Storage Humidity 10 to 85%/RH(non-condensing) Withstanding Voltage Primary-Secondary AC3,000V for 1minute Primary-Frame Ground AC2,500V for 1minute Secondary-Frame Ground AC500V for 1minute Isolation Resistance Primary-Secondary-Frame Ground 50M Ω (minimum) by DC500V insulation tester Vibration 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s 2,20minutes' period for 60minutes each along X,Y,Z axes(non- operating) Shock 296m/s 2 Cooling Convection Environmental Agencies Line Conducted Noise Built to meet FCC Part15-B Class B Built to meet VCCI Class B Built to meet EN55022 Class B Line Harmonic Distortion Built to meet IEC61000-3-2 Safety UL: UL1950, IEC950 C-UL: CSA C22.2 No.950 VDE EN60950, IEC950, VDE0805 MTBF [H] 313,000 Switching Frequency[kHz] 100(typ.) Function/Protection Over current Protection Current Limiting with automatic recovery Over voltage Protection (≥110% of Rated Output Voltage[V]) output shutdown(to reset, leave 1minute after shut-off) Remote Sense not available Remote On/Off option Power Fail Detection not available Series Operation not available Parallel Operation not available Mechanical Dimension [mm] 95W × 220L × 55H Weight g 480g enclosed type:600g

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Derating Curve Dimension (mm)