PE175B-10F PERKINELMER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

www.perkinelmer.com/opto PE175B-10F and PE175B-10UV CERMAX® FOCUSED XENON ARC LAMPS Lighting Imaging Telecom Cermax® Xenon Arc Lamps

Applications

  • Medical and industrial fiber optic illu- minators
  • Machine vision
  • Infrared and visible spotlights/beacons
  • Spectroscopy
  • Microscopy
  • UV Curing
  • Video projection

Description

The Cermax® xenon arc lamp is an innova- tive lamp design in the specialty lighting industry. These lamps were introduced in the early 1980’s and are now used in endo- scopes in most major hospitals worldwide, in high brightness projection display sys- tems, and for a wide variety of other high performance applications. The PE175B-10F and PE175B-10UV Cermax® lamps have an integrated elliptical reflector, enabling high intensity, focused output of ultraviolet, visible, and infrared radiation. With their internal reflector and rugged ceramic body construction, Cermax® lamps are the safest and most compact alter- native to conventional quartz xenon lamps. This makes them ideal for applications that require a high degree of illumination control. Current-regulated or power-regulated power supplies with output ripples of less than 5% are recommended. Single shot ignition pulses are advised because radio frequency starters may damage the lamps internal reflector. In addition to lamps, PerkinElmer Optoelectronics manufactures Cermax® arc lamp power supplies, lamp holders, OEM lighting systems, and fiber optic light sources.

PerkinElmer welcomes inquiries about special lamps. We would be pleased to discuss the requirements of your application and th e feasibility of designing a lamp specifically suited to your needs. For more information e-mail us at opto@perkinelmer.com or visit our web site at www.perkinelmer.com/opto. All values are nominal; specifications subject to change without notice. © 2000 PerkinElmer inc. All rights reserved. www.perkinelmer.com/opto USA: PerkinElmer Optoelectronics 44370 Christy St. Fremont, CA 94538 Phone: (510) 979-6500 Fax: (510) 687-1140 Toll Free: (800) 775-6786 Europe: PerkinElmer Optoelectronics GmbH Wenzel-Jaksch-Str. 31

65199 Wiesbaden

Phone: +49 611 492 0 Fax: +49 611 492 369 Asia: PerkinElmer Optoelectronics

47 Ayer Rajah Crescent #06-12

Phone: +65 775 2022 Fax: +65 775 1008 Description Nominal Range Power 175 watts 150-200 watts Current 14 amps (DC) 12-16 amps (DC) Operating Voltage 12.5 volts (DC) 10.5-13.5 volts (DC) Ignition Voltage 23 kilovolts (recommended minimum) Temperature 150º C (maximum) Lifetime* 1000 hours (500 hour warranty) * End of lamp life is defined as 50% of initial output. Operational Specifications Output at Nominal Power PE175B-10F and PE175B-10UV Physical Specifications Description Specification Arc Gap .038 inch (0.96mm) Reflector Geometry Ellipsoidal 1= X 2/M2 +Y2/N2 Weight 150 grams Window Diameter 1 inch (25.4 mm) Focused Output F= UV Filtered Output/ UV = UV Enhanced Output Description PE175B-10F Radiant Output* 34 watts UV Output* 1.5 watts IR Output* 18.8 watts Visible Output* 2740 Lumens Color Temperature 5900 Kelvin Peak Instabilities 4% Spot Size at Crossover .09” at 50% pts Spot Size at Crossover .23” at 10% pts *These values indicate total output in all directions. Wavelengths = UV<390nm, IR>770nm, Visible 390nm to 770nm. ** Beam Geometry defined as half angle at 10% PTS after 01/100/1000 hours. Notes 1. Lamp must not be operated with window facing upwards within 45º of vertical. 2. Seal temperature must not exceed 150º C. 3. Current/power regulated power supplies and PerkinElmer lamp housing units are recommended. 4. Lamp must be operated within recommended current and power range. Over powering may lead to arc instability, hard starting and premature aging. 5. Hot mirror assembly is available for IR filtering. 6. CERMAX lamps are much safer lamps to use than their quartz xenon arc lamp equivalents. However, caution must be practiced when operating lamps because they are under high pressure, require high voltage, reach temperatures up to 200º C, and their IR and UV radiation can cause skin burns and eye damage. Read hazard sheet included with each lamp shipment. Dimensions Focal Point Cathode CL Ellipse Dimensions in parentheses are in millimeters. Reflector Edge 1.298 (32.97) M=1.059 N=0.50 .866 (21.99) .008 (.203) .126 (3.2) 6-32 UNC 2B x .156 DP

3 Holes EQ SP on A

.750 (19.05) BC 2 x .40 (10.2) .035 (.899) 2.167 (55.04) 1.00 (25.4) 1.00 (25.4) .165 (4.19) .250 (6.35) .55 (13.97) .250 (6.35) PE175B-10UV 34 watts 4.9 watts 18 watts

2460 Lumens

5050 Kelvin

0.9” at 50% pts .23” at 10% pts Description Visible Output* Total Output 6mm aperture 1930 Lumens 18.5 watts 3mm aperture 1170 Lumens 9 watts * Nominal values at 175 watts after 2 hour burn-in Spectral Output RELATIVE OUTPUT F UV F + HOT MIRROR WAVELENGTH (NM) 200 300 400 500 600 700 800 900 1000 1100 100 DS-165 Rev C 1101