Features
Small double-end package High reliability Spectral range of sensitivity: 760-1100nm Fast Response time RoHS compliance
Applications
Infrared sensor
Description
The PDP91608BT11 is a silicon photo diode housed in a miniature SMD package. The device comes with a superior filtering for visible light by utilizing special black molding compound. Cathode Anode
CT Micro Rev 0.2(Preliminary) Only for Canon Page 2 Jun, 2018 PDP91608BT11 SMD Type Photo Diode with Daylight Filter Absolute Maximum Rating at 250C Symbol Parameters Ratings Units Notes VR Reverse Voltage 33 V Topr Operating Temperature -40 ~ +85 0C Tstg Storage Temperature -40 ~ +100 0C Tsol Soldering Temperature 260 0C 1 Pto Total Power Dissipation 150 mW Electro-Optical Characteristics TA = 25°C (unless otherwise specified) Optical Characteristics Symbol Parameters Test Conditions Min Typ Max Units Notes Spectral Bandwidth - 760 - 1100 nm P Peak Sensitivity - - 900 - nm θ1/2 View Angle at X axis VR=5V - 52.5 - deg View Angle at Y axis - 47.5 - deg
Electrical Characteristics
Symbol Parameters Test Conditions Min Typ Max Units Notes ID Dark Current Ee=0mW /cm2 VR=10V - - 10 nA VBR Reverse Breakdown Voltage Ee=0mW /cm2 IR=100uA 33 - - V VOC Open-Circuit Voltage Ee=1mW /cm2 P=940nm - 0.30 - V ISC Short-Circuit Current - 1.50 - µA IR Reverse Light Current Ee=1mW /cm2 P=940nm, VR=5V 1.0 1.83 - µA CT Transition Capacitance Ee=0mW /cm2 f=1MHz ,VR=5V - 0.85 - pF
CT Micro Rev 0.2(Preliminary) Only for Canon Page 3 Jun, 2018 PDP91608BT11 SMD Type Photo Diode with Daylight Filter Switching Characteristics Symbol Parameters Test Conditions Min Typ Max Units Notes tr Rise Time VR = 10V, RL = 10kΩ - 400 - ns 2 tf Fall Time - 400 - Notes: 1 : Soldering time≦5 seconds. 2 : Test circuit :
CT Micro Rev 0.2(Preliminary) Only for Canon Page 4 Jun, 2018 PDP91608BT11 SMD Type Photo Diode with Daylight Filter Typical Characteristic Curves
CT Micro Rev 0.2(Preliminary) Only for Canon Page 5 Jun, 2018 PDP91608BT11 SMD Type Photo Diode with Daylight Filter Typical Characteristic Curves
CT Micro Rev 0.2(Preliminary) Only for Canon Page 6 Jun, 2018 PDP91608BT11 SMD Type Photo Diode with Daylight Filter Package Dimension All dimensions are in mm, unless otherwise stated Recommended Soldering Mask All dimensions are in mm, unless otherwise stated
Ordering Information
Part Number Description Quantity PDP91608BT11 Tape & Reel 3000 pcs
CT Micro Rev 0.2(Preliminary) Only for Canon Page 7 Jun, 2018 PDP91608BT11 SMD Type Photo Diode with Daylight Filter Reel Dimension All dimensions are in mm, unless otherwise stated Tape Dimension All dimensions are in mm, unless otherwise stated
CT Micro Rev 0.2(Preliminary) Only for Canon Page 8 Jun, 2018 PDP91608BT11 SMD Type Photo Diode with Daylight Filter Reflow Profile Profile Feature Pb-Free Assembly Profile Temperature Min. (Tsmin) 150°C Temperature Max. (Tsmax) 200°C Time (ts) from (Tsmin to Tsmax) 60-120 seconds Ramp-up Rate (tL to tP) 3°C/second max. Liquidous Temperature (TL) 217°C Time (tL) Maintained Above (TL) 60 – 150 seconds Peak Body Package Temperature 260°C +0°C / -5°C Time (tP) within 5°C of 260°C 30 seconds Ramp-down Rate (TP to TL) 6°C/second max Time 25°C to Peak Temperature 8 minutes max.
CT Micro Rev 0.2(Preliminary) Only for Canon Page 9 Jun, 2018 PDP91608BT11 SMD Type Photo Diode with Daylight Filter DISCLAIMER CT MICRO RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. CT MICRO DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS. CT MICRO ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT EXPRESS WRITTEN APPROVAL OF CT MICRO INTERNATIONAL CORPORATION. 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with instruction for use provided in the labelling, can be reasonably expected to result in significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.