Wilcoxon Sensing Technologies 8435 Progress Drive Frederick, MD 21701 USA An Amphenol Company Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com buy.wilcoxon.com www.wilcoxon.com 99010 Rev.B.2 09/18 PC420A series RMS and peak acceleration loop powered sensors Key features

  • True RMS or calculated peak output
  • Easily integrated into existing process control systems
  • Intrinsically safe certified and explosion-proof models available
  • True peak output available
  • Manufactured in an approved ISO 9001 facility Certifications Wilcoxon’s PC420A series sensors provide a 4-20 mA output proportional to vibration, allowing for continuous trending of overall machine vibration. This trend data alerts users to changing machine conditions and helps guide maintenance in prioritizing the need for service. The choice of RMS or peak output allows you to choose the sensor that best fits your requirements. x (4-20 mA output type) yy (4-20 mA full scale) R = RMS output, acceleration P = calculated peak output, acceleration 05 = 5 g 10 = 10 g 20 = 20 g 50 = 50 g Table 1: PC420Ax-yy model selection guide Note: True peak output is available on PC420ATP series models.

Wilcoxon Sensing Technologies 8435 Progress Drive Frederick, MD 21701 USA An Amphenol Company Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. 99010 Rev.B.2 09/18 PC420A series RMS and peak acceleration loop powered sensors SPECIFICATIONS Accessories supplied: SF6 mounting stud (metric mounting available); calibration data (level 2) Full scale, 20 mA, ± 5% see Table 1 on page 1 Frequency response: ± 10% ± 3 dB 10 Hz - 1.0 kHz 1.0 Hz - 2.0 kHz Repeatability ± 2% Transverse sensitivity, max 5% Power requirements, 2-wire loop power: Voltage at sensor terminals 12 - 30 VDC Loop resistance1 at 24 VDC, max 700 Ω Turn on time, 4-20 mA loop < 30 seconds Grounding case isolated, internally shielded Operating temperature range –40° to +105° C Vibration limit 250 g peak Shock limit 2,500 g peak Sealing hermetic Sensing element design PZT, shear Weight 160 grams Case material stainless steel Mounting 1/4-28 tapped hole Output connector 2 pin, MIL-C-5015 style Mating connector R6 type Recommended cabling J9T2A Connections Function Connector pin loop positive (+) A loop negative (–) B ground shell Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com buy.wilcoxon.com www.wilcoxon.com Notes: 1 Maximum loop resistance (RL) can be calculated by: RL =

2 Lower resistance is allowed, greater

than 10 Ω recommended.

3 Minimum RL wattage determined by:

(0.0004 x RL). DC supply voltage RL (max resistance)2 RL (minimum wattage capability)3

12 VDC 100 Ω 1/8 watt

20 VDC 500 Ω 1/4 watt

24 VDC 700 Ω 1/2 watt

26 VDC 800 Ω 1/2 watt

30 VDC 1,000 Ω 1/2 watt

VDC power – 10 V 20 mAT ypic al cir cuit Model PC420V DC powe r suppl yR L Signal measuring equipment Pin A, 4-20 plus Pin B, 4-20 minus PL C / DCS Model PC420A