Northwest Power, Inc. (503)-652-6161 www.npi-inc.com Document No. 6997 Rev H Print Date: 2014-05-19 Page 1 of 4 PB1005AC(-F)(-G)(-H)(-HE) Data Sheet Power Bank PB1005AC(-F)(-G)(-H)(-HE) AC/DC Power Supply Up to 5 Outputs 1000W Low-Profile 1.68" All specifications are at nominal input, full load, 25 °C, all models, unless otherwise noted. Input Model -F - G - H - HE Nominal Input Voltage 115VAC 1 115/230 VAC 230VAC/300VDC 230VAC Input Voltage Range 95-132VAC 95-132VAC or 180-264VAC 180-264VAC or 250-375VDC 180-264VAC AC Input Frequency 47-440Hz 47-440Hz 47-440Hz 47-44 0Hz Voltage Sag Immunity to SEMI F47-0200 No No No Yes Hold-Up Time (Max Load, Nominal Line, Typical) 20 ms 20 ms 20ms 30ms Input Fuse (Internal) 20 A 15 A 20A 20A Inrush Current (264 VAC peak line, cold start.) 30Apk,max 30Apk,max 200Apk,typical 200Apk,typical Power Factor (typical) 0.60 Output 2 Output # A B C D E Maximum Output Current (Connector Limit) 80A 18A 40 A Output Voltage (Factory configurable) 1.8 to 52V 1. 8 to 52V Output Voltage Setpoint (50% load) ±1.2% ±1.2% Load Regulation, No load to full load (max.) ±0.2% ±0.5% Line Regulation, Low Line to High Line (max.) ±0.2% ±0.5% Maximum Output Power 500W 150W Remote Sense Yes No Output Ripple and Noise See individual Vicor modules specifications. Enable/inhibit function will affect this output Yes or No (Configurable for each output individually at the factory.) Trim range 10% to 110% of module nominal Vo 3 N/A Environmental Operating Temperature Range -20 °C to 70 °C Storage Temperature Range -40 °C to 70 °C Relative Humidity 5% -95% non-condensing Safety Important (!): Does not apply to (-F) operating at 230VAC Agency Approvals cTUVus, CE Safety Standard Compliance EN60950 Primary-to-Secondary Primary-Earth Secondary-Earth Isolation 3,000Vrms 1,500Vrms 250Vrms 1 Model -F will operate at 230VAC, but operation at 230VAC has not been evaluated for safety purposes. 2 Output voltage, current and power are limited to Vicor modules available. 3 Minimum load may be required to trim below 90%. Co ntact factory for details.
Northwest Power, Inc. (503)-652-6161 www.npi-inc.com Document No. 6997 Rev H Print Date: 2014-05-19 Page 2 of 4 PB1005AC(-F)(-G)(-H)(-HE) EMI and EMC Conducted Noise EN55022 Class A (150kHz-30MHz) Mechanical Dimensions 10.5" x 7" x 1.68" Cooling Internal Fans Weight (Typical, depends on configuration) 6.6 lb. (3 kg) Maximum Output Power vs. Ambient Air Temperature Model Input Voltage -20 to 60 °° °°C 60 to 70 °° °°C 70 °° °°C -F 115 VAC 800 W 800W 800W -G 115 VAC 600 W 600W 600W -G 230 VAC 1,000 W Derate 20W/ °° °°C 800W -H 230 VAC or 300 VDC 1,000 W Derate 20W/ °° °°C 800W -HE 230 VAC 1,000 W Derate 20W/ °° °°C 800W Mechanical Outline Drawing
Northwest Power, Inc. (503)-652-6161 www.npi-inc.com Document No. 6997 Rev H Print Date: 2014-05-19 Page 3 of 4 PB1005AC(-F)(-G)(-H)(-HE) Connections Input Pin Signal Description or Symbol Details
1 L1 AC Line 1
2 Safety Ground
3 L2 / N AC Line 2 or Neutral
Details Pin Signal Description Option -M Option -B Option -R 1 + Positive Terminal, 49A max 2 + Positive Terminal, 49A max Positive Terminal 1/4" hole, 100A max Positive Terminal #8 tapped hole 5/16" deep, 100A max 3 - Negative Terminal, 49A max 4 - Negative Terminal, 49A max Negative Terminal 1/4" hole, 100A max Negative Terminal #8 tapped hole 5/16" deep, 100A max Outputs A and B - Remote Sense/Trim Connector Pin Signal Description Details 1 + Positive Sense Connection
2 Trim Trim input
3 - Negative Sense Connection Output C Pin Signal Description Details 1 - Negative Terminal, 18A max 2 + Positive Terminal, 18A max Outputs D and E Pin Signal Description Details 1 + Positive Terminal, 20A max 2 - Negative Terminal, 20A max I/O Connections Note: All control signals are isolated; Input - 3,000 Vrms; Output - 250 Vrms; Chassis - 250 Vrms Pin Signal Description Details Option -N Option -E
1 Output Inhibit or Enable
Application of 5V to 24V signal inhibits all controlled outputs. Optoisolator input with 4.5k Ω series resistor. Application of 5V to 24V signal enables all controlled outputs. Optoisolator input with 4.5k Ω series resistor. 2 Not Connected Reserved for future use.
3 Output A Power Good Open Collector, 60V/1mA, Act ive Low = Power Good
4 Output B Power Good Open Collector, 60V/1mA, Act ive Low = Power Good
5 Output C Power Good Open Collector, 60V/1mA, Act ive Low = Power Good
6 Output D Power Good Open Collector, 60V/1mA, Act ive Low = Power Good
7 Output E Power Good Open Collector, 60V/1mA, Act ive Low = Power Good
8 I/O Control Signal Return All I/O control signals on pins 1-7 are referenced to this pin.
Northwest Power, Inc. (503)-652-6161 www.npi-inc.com Document No. 6997 Rev H Print Date: 2014-05-19 Page 4 of 4 PB1005AC(-F)(-G)(-H)(-HE) Vicor Custom Northwest Power designs and manufactures custom and standard power supplies using Vicor modules as core components. Information furnished by NORTHWEST POWER is believe d to be accurate and reliable. However, no responsi bility is assumed by NORTHWEST POWER or Vicor for its use. No license is granted by implication or otherwise und er any patent or patent rights of NORTHWEST POWER or Vicor . NORTHWEST POWER products are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to NORTHWEST POWER 's Terms and C onditions of Sale, which are available upon request . Specifications are subject to change without notice. Northwest Power, Inc.
4211 SE International Way, Suite F
Milwaukie, OR, USA Tel: 503-652-6161 Fax: 503-652-6868 www.npi-inc.com