Vicor Custom Power - Northwest (503)-652-6161 www.npi-inc.com Document No. 7663 Rev. E Print Date: 2014-05-19 Page 1 of 3 PB1004PFC Data Sheet Power Bank PB1004PFC AC/DC Power Supply
4 Outputs, 1000W
Low-Profile 1.75" (1U) SEMI F47 Compliant All specifications are at nominal input, full load, 25 °C, unless otherwise noted. Input Input Voltage (nominal) 115/230Vac Input Voltage Range 90-264Vac Input Frequency 47-63 Hz Inrush Current (cold start.) <20 A at 115Vac, <40A at 230Vac Input Fuse (internal) 20A Power Factor (minimum) 0.95 Input Harmonics EN 61000-3-2 Compliant Line dropout SEMI F47 Compliant when operated at 180-264Vac Output Output A B C D Maximum Output Current (Connector Limit) 80A 80A 40 A Output Voltage (Factory configurable) 1.8 to 52 V 1 .8 to 52 V 1.8 to 52 V Module Size Maxi Mini Micro Micro Output Voltage Setpoint (50% load) ±1.2% ±1.2% ±1.2% ±1.2% Load Regulation, No load to full load (max) ±0.2% ±0.2 % ±0.5% ±0.5% Line Regulation, Low Line to High Line (max) ±0.2% ±0.2 % ±0.5% ±0.5% Remote Sense Yes Yes No No Output Trim Yes Yes Yes Yes Output Ripple and Noise See individual Vicor module specifications. Maximum Output Power (Individual output) 600W 300W 150W 150 W Maximum Output Power (Total all outputs) 1000W, See output power derating chart on page 2. Environmental Operating Temperature Range (see output power derating on page 2) -20 °C to 50 °C Thermal Shutdown 100 °C internal module shutdown, non-latching Storage Temperature Range -40 °C to 70 °C Relative Humidity 5% -95% non-condensing Safety Agency Approvals cTUVus, CE Safety Standard Compliance EN 60950 Isolation, Primary-to-Secondary 3000Vrms Isolation, Primary-Earth 1500Vrms Isolation, Secondary-Earth 250Vrms
Vicor Custom Power - Northwest (503)-652-6161 www.npi-inc.com Document No. 7663 Rev. E Print Date: 2014-05-19 Page 2 of 3 PB1004PFC Output Power Derating 100 200 300 400 500 600 700 800 900 1000 1100 80 130 180 230 280 AC Input Voltage ( Vac ) Output Power ( W ) At 25 °C. Output power may be further limited at higher ambient temperature. Contact factory for details. EMI and EMC Conducted Noise EN55022 Class A (150kHz-30MHz) Mechanical Dimensions Mounting Options (contact factory for details) Universal Mounting Brackets Short Front Panel or Full 19" Front Panel Cooling Internal Fans Weight (Typical, depends on configuration) 5.5 lb. (2.5 kg) Input Power Connections Connector Details IEC320 Standard pin configuration Optional Cord Retainer Long Wire Bail NPI P/N 4340, Qualtek #730B-00/05 Short Wire Bail NPI P/N 4013, Qualtek #730B-00/00 Front Panel LEDs One Red/Green LED for each main output Color Signal Description Details Green Output OK Corresponding output voltage is correct, i.e. suffi ciently high if output is populated or zero if output is not populated. Red Output Not OK Corresponding output voltage is t oo low.
Vicor Custom Power - Northwest (503)-652-6161 www.npi-inc.com Document No. 7663 Rev. E Print Date: 2014-05-19 Page 3 of 3 PB1004PFC Output Power Connections for Channels A and B Details Pin Signal Description Molex Minifit Sr. Connector (Option -M) (Molex 42820-4212) Straight Bus Bar (Option -B) Right-Angle Bus Bar (Option -R) 1 + Positive Terminal, 49A max 2 + Positive Terminal, 49A max Positive Terminal, 1/4" hole, 100A max Positive Terminal, Tapped 1/4-20 hole, 100A max 3 - Negative Terminal, 49A max 4 - Negative Terminal, 49A max Negative Terminal, 1/4" hole, 100A max Negative Terminal, Tapped 1/4-20 hole, 100A max Output Power Connections for Channels C and D (Molex 42820-4212) Pin Signal Description Details 1 + Output D, Positive Terminal, 49A max 2 - Output D, Negative Terminal, 49A max 3 + Output C, Positive Terminal, 49A max 4 - Output C, Negative Terminal, 49A max Trim/Remote Sense Connections for Channels A and B (AMP 102617-1) (Remote sense is active only if Maxi or Mini size module is installed.) Pin Signal Description Details 1 +Sense B Positive Sense Connection (Internally connected to positive output through 50 Ω resistor fused by 0.17A Polyfuse) 2 Trim B Connect this pin with a resistor to Pin 1 for trim up, or to Pin 3 for trim down. 3 - Sense B Negative Sense Connection (Internally connected to negative output through 50 Ω resistor) 4 +Sense A Positive Sense Connection (Internally connected to positive output through 50 Ω resistor fused by 0.17A Polyfuse) 5 Trim A Connect this pin with a resistor to Pin 1 for trim up, or to Pin 3 for trim down. 6 - Sense A Negative Sense Connection (Internally connected to negative output through 50 Ω resistor) I/O Connections (Molex 70555-0038) Note: All control signals are isolated; Input - 3,000 Vrms; Output - 250 Vrms; Chassis - 250 Vrms Pin Signal Description Details 1 12V Aux 12V/100mA Auxiliary Stand-By Output
2 Pgood Open Collector, 40V/5mA, Active Low = Power Good
3 Inhibit Connect to Pin 4 (Control Return) to inhi bit all outputs, except 12V Aux. 4 Control Return Reference for all signals on I/O c onnector. Return for 12V Aux. Information furnished by NORTHWEST POWER is believed to be accurate and reliable. However, no responsibility is assumed by NORTHWEST POWER or Vicor for its use. No license is granted by implication or otherwise under any patent or patent rights of NORTHWEST POWER or Vicor. NORTHWEST POWER products are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to NORTHWEST POWER 's Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice. Vicor Custom Power - Northwest ♦ 4211 SE International Way, Suite F ♦ Milwaukie, OR, USA Tel: 503-652-6161 ♦ Fax: 503-652-6868 ♦ www.npi-inc.com