OPC120P-F201-B17 PF | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

< Reading on highly reflective surfaces with new polarization filter < PROFINET interface with integrated switch < Reads Data Matrix codes at high speeds of up to 10 m/s at 50 readings/s Optical Print Inspector, reading of Data Matrix codes, PROFINET, speeds up to 10 m/sec, polarization filter Function With the Optical Print Inspector, Pepperl+Fuchs provides the solution to code reading and detection tasks in the field of printing, paper, and packaging. Whether reading 1-D and 2-D codes at high speeds, reading reliably on reflective surfaces and at varying intervals, or performing various detection tasks — with the Optical Print Inspector, you always have the right Vision Sensor close at hand. Release date: 2020-06--

05 Date of

Release date: 2020-06-05 Date of issue: 2020-06-05 Filename: 261656_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

21.75 12.5 83.8 M12 M12 M6 x 9 (4x) Technical Data General specifications Light type Integrated LED lightning (white) Polarization filter yes Symbologies Data Matrix Read distance 70 ... 180 mm Nominal distance: 120 mm Reading field Minimum read field: 28 mm x 45 mm Read field at nominal distance: 45 mm x 70 mm Maximum read field: 65 mm x 105 mm Modul size Minimum module size: 0.2 mm Evaluation frequency up to 50 Hz Target velocity triggered max. 10 m/s Data Matrix Symbol size rectangular up to 144 x 144 modules rectangular up to 16 x 48 modules Data format ASCII, C40, Text, X12, Edifact, Base 256 , all according to ISO 646 Orientation omnidirectional Nominal ratings Camera Type CMOS , Global shutter Number of pixels 752 x 480 pixels Gray scale 256 Image recording real-time , Program-controlled or triggered externally Functional safety related parameters Stationary read device OPC120P-F201-B17 Release date: 2020-06-05 Date of issue: 2020-06-05 Filename: 261656_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

MTTFd 40.5 a Mission Time (TM) 8 a Diagnostic Coverage (DC) 0 % Indicators/operating means LED indicator 7 LEDs (communication, alignment aid, status information) Electrical specifications Operating voltage UB 24 V DC ± 15% , PELV No-load supply current I0 max. 300 mA Power consumption P0 6 W Interface Interface type 100 BASE-TX Protocol PROFINET IO Real-Time (RT) Conformance class A Transfer rate 100 MBit/s Interface 2 Interface type USB Service Input Input voltage to be applied externally 24 V ± 15% PELV Number/Type Trigger Input current approx. 10 mA at 24 V DC Switching threshold low: < 10 V, high: > 15 V Cable length max. 30 m Output Switching type PNP Switching voltage to be applied externally 24 V ± 15 % PELV Switching current 100 mA each output Cable length max. 30 m Compliance with standards and directives Standard conformity Noise immunity EN 61326-1:2006 Emitted interference EN 61000-6-4:2007/A1:2011 Degree of protection EN 60529 Laser class IEC 60825-1:2007 Approvals and certificates UL approval cULus Listed, General Purpose, Class 2 Power Source, Type 1 enclosure CCC approval CCC approval / marking not required for products rated ≤36 V Approvals CE Ambient conditions Relative humidity 90 % , noncondensing Mechanical specifications Degree of protection IP65 Connection 8-pin, M12x1 connector, standard (supply+IO) , 4-pin, M12x1 socket, D-coded (LAN) , 4-pin, M12x1 socket, D-coded (LAN) Material Housing PC/ABS Optical face Plastic pane Installation 4 x M6 threading Mass approx. 200 g Stationary read device OPC120P-F201-B17 Release date: 2020-06-05 Date of issue: 2020-06-05 Filename: 261656_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

+ UB USB_DM USB_DP NC NC GND NC TX + RX + TX - RX - Bus Main Connection Assignment Profinet 1 & 2 Main 4 2 Characteristic Curve (Nominal distance)Operating distance [mm] Image field dimensions Image field Width Y Width X 0 20 40 60 80 100 120 140 160 180 200 Stationary read device OPC120P-F201-B17 Release date: 2020-06-05 Date of issue: 2020-06-05 Filename: 261656_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

(Nominal distance)Operating distance 0.3 mm 0.4 mm 0.5 mm Read ranges DataMatrix 0 40 60 80 100 120 140 160 180 200 [mm] Accessories V19-G-2M-PUR-ABG Female cordset, M12, 8-pin, shielded, PUR cable V1SD-G-2M-PUR-ABG- V45-G Connection cable, M12 to RJ-45, PUR cable 4-pin, CAT5e V1SD-G-2M-PUR-ABG- V45X-G Connection cable, M12 to RJ-45, PUR cable 4-pin, CAT5e V19-G-ABG-PG9 Female connector, M12, 8-pin, shielded, field attachable V19-G-0,2M-YOPC-0,2M- V1S/V31-G Y connection cable Stationary read device OPC120P-F201-B17 Release date: 2020-06-05 Date of issue: 2020-06-05 Filename: 261656_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Release date: 2020-06-05 Date of issue: 2020-06-05 Filename: 261656_eng.pdf OPC120P-F201-B17 Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Stationary read device The Optical Print Inspector is equipped with seven indicator LEDs for carrying out visual function checks and rapid diagnostics. In addition, the device is fitted with two buttons on the back of the unit. Other suitable accessories can be found at www.pepperl-fuchs.com Indication Indicators/Controls LED Color Label Description

1 Green BUS Link PROFINET connection activated

2 Yellow BUS TX / RX PROFINET data transfer

3 Red BUS / ERR PROFINET communication error

4 Green/red GOOD / BAD Reading successful/failed

5 Yellow TRIGGER Trigger sensor triggered

6 Yellow RUN Device ready for operation

7 Red/yellow/gr

2 GOOD / BADBUS LIN

K BUS TX / RX TRIG GER RUNIN TERNAL DIAGNOSTICBUS / ERR