NPS ON/OFF Input Sensor Controller NPS SERIES Multi-functional DIN rail mounting slim sensor controller panasonic.net/id/pidsx/global DIN rail mounting Mountable on 35 mm 1.378 in DIN rail by one-push. It reduces mounting space and mounting operations. 35 mm 1.378 in width DIN rail Edge trigger Synchronized input is possible at either the rising or the falling edge of the external synchronization signal. With this, now only one controller suffices where earlier two were required in applications, such as, detecting presence of bottle caps. NPS-CT7 Example: Detecting presence of cap on bottle
- Conventional method • Using NPS-CT7 External synchronization input Output Sensor for sensing Sensor signal input Controller Controller with timer Synchronizing sensor External synchronization input OutputNPS-CT7 Sensor signal input Effective (condition for making output ON) Ineffective Effective Ineffective (condition for disabling output) External synchronization input Output 5 μs approx. No cap Cap present ON OFF Two outputs: contact and non-contact Useful for various applications because the controller has two outputs, relay contact and NPN open-collector transistor output. NPS-C7, NPS-CT7 Connects two sensors Two sensors can be connected, and two independent outputs are generated. NPS-C7W
ON/OFF Input Sensor Controller NPS SERIES 962 FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONSSIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORSSTATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Sensor Mounting Stand Sensor Checker Sensor Controller Other Products NPS SPECIFICATIONS Type DIN rail mounting General use High-performance Two sensor connection Item Model No. NPS-C7 NPS-CT7 NPS-C7W Applicable sensors Photoelectric sensor, inductive proximity sensor, etc., with NPN transistor output or relay output Supply voltage 100-240 V AC ±10 % Power consumption 6 VA or less Power supply for sensor Voltage 12 V DC ±10 % (incorporated with short-circuit protection) Current 150 mA max. 130 mA max. 120 mA max. Output Relay contact 1c
- Switching capacity:
250 V 3 A AC (resistive load)
- Electrical life: 100,000 switching operations or more (rated load)(at 1,800 operations/hour)
- Mechanical life: 10 million switching operations or more (at 36,000 operations/hour) NPN open-collector transistor
- Maximum sink current: 100 mA or less
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage:
1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
Relay contact 1c ×2
- Switching capacity:
- Electrical life: 100,000 switching operations or more (rated load)(at 1,800 operations/hour)
- Mechanical life: 10 million switching operations or more (at 36,000 operations/hour) Output operation Switchable normal operation or inverse operation Response time Relay contact: 10 ms approx., NPN open-collector transistor: 5 µs or less 10 ms approx. Indicators Power Red LED (lights up when the power is ON) Output (Note 2) Red LED (lights up when the output is ON) Sensor signal input – Red LED lights up when the sensor signal input is effective External synchronization input Red LED lights up when the external synchronization input is effective External synchronization function Gate trigger Gate trigger and edge trigger – Timer function – Three function selectable timer Timer period: switchable either 40 ms to 1 sec. or 0.4 sec. to 10 sec. Environmental resistance Ambient temperature -10 to +50 °C +14 to +122 °F (No dew condensation or icing allowed), Storage:-30 to +70 °C -22 to +158 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Voltage withstandability 1,500 V AC for one min. between the power and the output terminals Insulation resistance 10 MΩ, or more, with 500 V DC megger between the power and the output terminals Vibration resistance 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions two times each Material Enclosure: ABS, Terminal block: PBT (Glass fiber reinforced) Connecting method Terminal block Weight Net weight: 160 g approx. Accessories Short bar: 1 pc., NPS-CV (Protection cover): 1 pc., Short-circuit protection plate: 1 pc., Adjusting screwdriver: 1 pc. (NPS-CT7 only) Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) In NPS-C7W, two output indicators, Sensor 1 output indicator and Sensor 2 output indicator, have been incorporated. ORDER GUIDE Type Appearance Model No. Supply voltage Power supply for sensor Output External synchronization function Timer function General use NPS-C7 100-240 V AC ±10 %
12 V DC ±10 %
150 mA max. • Relay contact 1c
- NPN open-collector transistor Gate trigger – High- performance NPS-CT7 12 V DC ±10 % 130 mA max. Gate trigger and edge trigger Three function selectable timer Two sensor connection NPS-C7W 12 V DC ±10 % 120 mA max. Relay contact 1c ×2 – – Accessory ・ NPS-CV (Protection cover)
ON/OFF Input Sensor Controller NPS SERIES FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Sensor Mounting Stand Sensor Checker Sensor Controller Other Products NPS I/O CIRCUIT AND WIRING DIAGRAMS NPS-C7 NPS-CT7 I/O circuit diagram Terminal arrangement diagram COM. NO NC 0 V 12 V ES 12 V IN 0 V 100 Ω 100 Ω 5.1 kΩ 5.1 kΩ *1 Relay contact 1c Terminal No. 100-240 V AC ±10 % Not connected OC (open-collector) output Not connected Control circuit Power supply circuit Internal circuit Users’ circuit Output relay 13 14 15 16 OC OUTIN0 9 10 11 12 ES+12 +12 5 6 7 8 1 2 3 4 AC NOCOM.AC NC NPS- 100-240 V AC ±10 % Relay contact output Note: Response time of the NPN open-collector transistor output of NPS-C7 and NPS-CT7 is 5 μs. If a relay or a micro-switch (mechanical contact) is connected, its bounce may result in output chattering. Take care of this aspect, especially when the timer function is used. NPS-C7W I/O circuit diagram 100 Ω 5.1 kΩ COM. 1 NO 1 NC 1 0 V 12 V IN 1 12 V IN 2 100 Ω 5.1 kΩ *1 0 V COM. 2 NO 2 NC 2 ⑯ Not connected Not connected Relay contact 1c Relay contact 1c Terminal No. Control circuit Power supply circuit Internal circuit Users’ circuit Output relay 1Output relay 2 100-240 V AC ±10 % Terminal arrangement diagram Non-voltage contact or NPN transistor output High: 4 to 12 V, or open Low: 0 to 1.5 V or +12 V * 1 13 14 15 16 IN 1+120 9 10 11 12 IN 2+120 5 6 7 8 1 2 3 4 AC NO 1COM. 1AC NC 1 NPS-C7W NO 2COM. 2 NC 2 100-240 V AC ±10 % Relay contact output Non-voltage contact or NPN transistor output High: 4 to 12 V, or open Low: 0 to 1.5 V or +12 V * 1
ON/OFF Input Sensor Controller NPS SERIES 964 FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONSSIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORSSTATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Sensor Mounting Stand Sensor Checker Sensor Controller Other Products NPS PRECAUTIONS FOR PROPER USE Refer to p.1595 for general precautions.
- Never use this product in a device for personnel protection.
- In case of using devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Functional description NPS-C7 ᶑ ᶑ ᶇ ᶄ ᶃ ᶊ ᶋ ᶃ ᶎᶐ ᶏ ᶑ ᶑ ᶌᶇ ᶍᶄ ᶆ ᶃ ᶑ ᶑ ᶉᶈᶅ NPS-CT7 NPS-C7W Description Function ① Power indicator (Red LED) Lights up when the power is ON. ② Output indicator (Red LED) Lights up when the output is ON.③ Sensor 1 output indicator (Red LED) ④ Sensor 2 output indicator (Red LED) Sensor signal input selection switch Selects the output operation. */7 /03. INV.: The output is ON when the sensor signal input is High. NORM.: The output is ON when the sensor signal input is Low. ⑥ Sensor 1 output operation mode switch Selects the output operation. */7 /03. INV.: The output is ON when the sensor signal input is High. NORM.: The output is ON when the sensor signal input is Low. ⑦ Sensor 2 output operation mode switch⑧ Sensor signal input indicator (Red LED) Indicates the state of the sensor signal input. The operation differs according to the mode set with ⑤ Sensor signal input selection switch. INV.: Lights up when the sensor signal input is High. NORM.: Lights up when the sensor signal input is Low. External synchronization input indicator (Red LED) Indicates the state of the external synchronization input. Lights up when the external synchronization input does not disable the output. Block diagrams (The diagrams below explain NPS’s operation in a simple manner. The actual circuits may differ slightly.) NPS-C7 Relay output Open-collector output AND 12 V IN ES 12 V INV. INV. Sensor signal input selection switch Output indicator NPS-C7W 12 V IN 1 INV. INV. Sensor 1 output operation mode switch Sensor 2 output operation mode switch 12 V IN 2 Relay output 1 Sensor 1 output indicator Sensor 2 output indicator Relay output 2 INV. INV. NPS-CT7 12 V IN Sensor signal input selection switch External synchronization operation mode switch Timer operation mode switch 12 V ES Relay output External synchronization input indicator Open-collector output Edge AND OND OFD OSD Without timer Timer circuit 10 sec. Gate/Edge trigger operation mode switch Output indicator Delay time selection switch Timer adjuster INV. Sensor signal input indicator 1 sec. INV. INV. Description Function External synchronization operation mode switch Selects the operation of external synchronization. */7 /03. INV.: The output is neglected when the external synchronization input is High. NORM.: The output is neglected when the external synchronization input is Low. Gate/Edge trigger operation mode switch Selects Gate trigger or Edge trigger. : Effective at the instant the external synchronization input is applied. : Effective over the period for which the external synchronization input is applied. ⑫ Timer period selection switch Selects the timer period. TFD TFD 1 sec.: Variable from 40 ms approx. to 1 sec. approx. ⑬ Timer operation mode switch Selects the timer operation. A Ineffective B ON-delay C OFF-delay D ONE SHOT ⑭ Timer adjuster Set the timer period. ⑮ Terminal block –
ON/OFF Input Sensor Controller NPS SERIES FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Sensor Mounting Stand Sensor Checker Sensor Controller Other Products NPS
- ON-delay (OND) <Function>: Neglects short output signals. <Application>: As only long signals are extracted, this function is useful for detecting if a line is choked or for sensing only objects taking a long time to travel.
- OFF-delay (OFD) <Function>: Extends the output signal for a fixed period of time. <Application>: This function is useful if the output signal is so short that the connected device cannot respond.
- ONE SHOT (OSD) <Function>: Outputs a fixed width signal upon sensing. <Application>: This function is useful when the input specifications of the connected device require a signal of fixed width. Of course, it is also useful for extending a short width signal to a desired width. Various other applications are possible. Timer functions (NPS-CT7 only)
- NPS-CT7 has three types of convenient built-in timer functions. Selection switch and timer operation Switch setting Sensor signal input Sensor signal input selection Timer operation selection Output operation /03.*/7 Input not inverted normal operation Input not inverted ON-delay Input not inverted OFF-delay Input not inverted ONE SHOT /03.*/7 Input inverted normal operation Input inverted ON-delay Input inverted OFF-delay Input inverted ONE SHOT 0/% 0'% 0/% 0'% 0/% 0'% 0/% 0'% 0/% 0'% 0/% 0'% 0/% 0'% 0/% 0'% 5 5 5 5 5 5 5 5 5 5 5 5 0'' 0'' 0'' 0'' 0'' 0'' 0'' 0'' )JHI -PX PRECAUTIONS FOR PROPER USE Refer to p.1595 for general precautions. External synchronization function (NPS-C7, NPS-CT7 only)
- Gate trigger The output is disabled when the external synchronization input is Low [mode selection switch on NORM. (Note)] or is High [mode selection switch on INV. (Note)]. Effective condition for making output ON( ) ( ) Ineffective Effective Ineffective condition for disabling output ON OFF Output Sensor signal input External synchronization input Note: Since NPS-C7 is not incorporated with the selection switch, the output is disabled only when the external synchronization input is Low.
- Edge trigger (NPS-CT7 only) The sensor signal is judged at the instant the external synchronization input rises up or falls down. This sensor is ideal for cap presence detection that would have required two controllers in the past. Conventional NPS-CT7 OutputController Controller with timer Synchronizing sensor External synchronization input Sensor for sensing Sensor signal input OutputNPS-CT7 External synchronization input Sensor signal input t: 5 μs approx. No cap Cap present Output Sensor signal input External synchronization input Effective condition for making output ON( ) ( ) Ineffective Effective Ineffective condition for disabling output ON OFF Note: As the output time ‘t’ is only 5 μs approx., extend it by using the OFF- delay timer or the ONE SHOT timer. Mounting
- To mount NPS with screws, use M4 screws. The tightening torque should be 0.78 N•m or less. Example: Detecting presence of cap on bottle
ON/OFF Input Sensor Controller NPS SERIES 966 FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONSSIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORSSTATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Sensor Mounting Stand Sensor Checker Sensor Controller Other Products NPS PRECAUTIONS FOR PROPER USE Refer to p.1595 for general precautions.
- Dimensions of suitable crimp terminals (Unit: mm in) Y-shaped type Round type 3.2 0.126 or more 6 0.236 or less 6 0.236 or less 19 0.748 or less 10 0.394 or less (When crimped) Ø3.2 Ø0.126 or more 6 0.236 or less 6 0.236 or less 19 0.748 or less 10 0.394 or less (When crimped) Note: Use crimp terminals having insulation sleeves. Recommended crimp terminal: Nominal size 1.25-3.0
- NPS-C7 and NPS-CT7 do not incorporate a short-circuit protection at the NPN open-collector transistor output. Do not connect them directly to a power supply or a capacitive load.
- The response time of the NPN open-collector transistor output of NPS-C7 or NPS-CT7 is 5 μs. If a relay or a micro-switch (mechanical contact) is connected, take care since its bounce may result in output chattering.
- Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Others
- Do not use during the initial transient time (0.5 sec.) after the power supply is switched on.
- Avoid dust, dirt, and steam.
- Take care that the controller does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. Wiring
- Make sure that the power supply is off while wiring.
- Verify that the supply voltage variation is within the rating.
- Short-circuit protection plate Short-circuit protection plate The short-circuit protection plate is attached to terminal No. 1 to prevent AC short-circuit. Flip the plate up, connect the wire to terminal No. 1, and then flip it down. The short-circuit protection plate is attached at the time of shipment from our factory.
- Short bar The short bar saves wiring when a common power supply is used for the AC supply terminal and the load supply of the relay contact output. The short bar is attached between the terminal Nos. 1 and 2 at the time of shipment from our factory. To use a separate power supply for the output relay, make sure to remove it. Power supply circuitOutput relay Terminal No. Short-circuited with the short bar Control circuit Load Power supply Short bar Typical wiring diagram NPS-□ Power indicator (Red) Output indicator (Red) Mode selection switchesTimer adjuster Short-circuit protection plate 3.150 1.260 80 3.150 7.5 0.295 22 0.866 2.756 2-4.5 × 5.5 0.177 × 0.217 oblong holes Suitable for 35 mm 1.378 in width DIN rail Sensor signal input indicator (Red) External synchronization input indicator (Red) Short bar Notes: 1) The above drawing illustrates the dimensions of NPS-CT7. The dimensions of NPS-C7 and NPS-C7W are identical to those given above. 2) The front panel of each model is different. Refer to p.964 for more details of the front panels. Assembly dimensions with attached protection cover 3.150 1.260 (83.5) (3.287) DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website.