High Accuracy, Low Noise Mid -to-High Voltage DC -DC Converter 10,000V, 15,000V NHV Series DC-DC Converter BHV20170526_B01 The NHV series is our mid -to-high voltage DC -DC converter featuring high accuracy and low nois e. It s design for minimizing line regulation, load regulation, temperature drift and time-course drift enables highly accurate and stable voltage to be provided. A hexahedron metal shield case ensures low noise along with a selection of a circuit suitable for noise suppression. Output voltage is adjustable by external voltage or an external variable resistor. A built-in short-circuit and over current protection ensure high reliability and a long life. ■ Features ・Temperature drift 50ppm/°C ・Output voltage monitor ・Time-course drift 10ppm/1min. ・Output current monitor ・Low ripple noise 100mVp-p ・Built-in short-circuit, over current protection ・Output capacity 7W ・ON/OFF control ・Adjustable output voltage range 0 - 100% ・Reference voltage output with high stability ・Hexahedron metal shield case ・High reliability / Long life ・Non-isolated type ■ Model/Rating Table 1 Models NHV Series Input Voltage Vdc Output Voltage Vdc Output Current μA Input Current mA typ. Ripple & Noise mVp-p typ. NHV24-10K700P 22.8 - 25.2 0 - +10,000 0 - 700 650 100 NHV24-10K700N 22.8 - 25.2 0 - -10,000 0 - 700 650 100 NHV24-15K450P 22.8 - 25.2 0 - +15,000 0 - 450 650 100 NHV24-15K450N 22.8 - 25.2 0 - -15,000 0 - 450 650 100 ■ Specifications Table 2 Input voltage range Refer to Table 1 Rated input voltage 24V Rated output voltage Refer to Table 1 (with 100% preset output voltage, Vcont voltage 10V) Adjustable output voltage range Refer to Table 1 Rated output current Refer to Table 1 Ripple noise Refer to Table 1 Line regulation 10ppm typ. (for input voltage varying from 22.8V to 25.2V) Load regulation 10ppm typ. (for output current varying from 50% to 100%) Temperature regulation 50ppm/°C (for the ambient temperature varying from 0°C to +50°C) Short-term drift 10ppm/1minute (excluding the 1H initial drift) Long-term drift 100ppm/1hour (excluding the 1H initial drift) Output voltage monitor terminal 10V ±1% typ. at rated output voltage. (Output current 2mA max.) Output current monitor terminal 10V ±1% typ. at rated output current (Output current 2mA max.) Reference voltage terminal 10V ±0.1% max. (Output current 2mA max.) Over current protection Yes (Operates at 105% or above of rated load current. Auto restart type.) Short-circuit protection Yes Thermal shutdown Yes (Restart by reclosing after eliminating the factor) Remote ON/OFF Between 6pin (ON/OFF) and 3pin (S.GND): Output is ON when short, output is OFF when open Operating temperature range 0°C - +50°C Storage temperature range -20°C - +60°C Humidity range 20% - 95% RH (No condensation) Outer dimensions W=104 L=180 H=38 mm * The above specifications are provided with rated value, unless otherwise specified. * The contents provided in this datasheet may be changed at any time without prior notice.
High Accuracy, Low Noise Mid -to-High Voltage DC -DC Converter 10,000V, 15,000V NHV Series DC-DC Converter BHV20170526_B01 1. Scope Specifications shall apply to NHV series. 2. Model/Rating Model name Rated input voltage Rated output Remarks NHV24-10K700P DC24V +10kV, 700μA NHV24-10K700N DC24V −10kV, 700μA NHV24-15K450P DC24V +15kV, 450μA NHV24-15K450N DC24V −15kV, 450μA 3. Environmental conditions Operating temperature range: 0°C - +50°C Storage temperature range: -20˚C - +60˚C Humidity range: 20% - 95% RH (No condensation) 4. Specifications & Standards Unless otherwise described in the following table, input shall be rate d input voltage, output shall be rated output, and ambient temperature shall be +25°C. Item Specifications Condition NHV24- 10K700P NHV24- 10K700N NHV24- 15K450P NHV24- 15K450N Input voltage range 24V ±5% (22.8V - 25.2V) Rated input current 650mA typ. Rated output voltage +10kV −10kV +15kV −15kV Output voltage adjustable range 0V - +10kV 0V - −10kV 0V - +15kV 0V - −15kV Output voltage linearity 1% Vout=1% - 100% Rated output current 700μA 700μA 450μA 450μA Rated output power 7W Output ripple noise 100mVp-p typ. Static line regulation 10ppm typ. Vin=24V ±5% Static load regulation 10ppm typ. Iout=50 - 100% Temperature stability 50ppm/°C 0°C - +50°C Short-term stability 10ppm/1minute Excluding 1H initial drift Long-term stability 100ppm/1hour Excluding 1H initial drift Output voltage control 0V - 10V Output voltage preset accuracy Within ±1% of theoretical output voltage value Terminal for output voltage monitoring Output voltage 10V ± 1% typ. (Output current 2mA max.) At rated output voltage Terminal for output current monitoring Output voltage 10V ± 1% typ. (Output current 2mA max.) At rated output current Reference voltage terminal Output voltage 10V ± 0.1% max. (Output current 2mA max.) Over current protection Yes (Operates at 105% or above . Auto restart type) Output short-circuit protection Yes Thermal shutdown Yes (Restart by reclosing after eliminating the factor) ON/OFF control Yes
High Accuracy, Low Noise Mid -to-High Voltage DC -DC Converter 10,000V, 15,000V NHV Series DC-DC Converter BHV20170526_B01 5. Outer dimensions 3.2 min. 5.7 HV OUT (Tinned annealed copper wire) UL STYLE 3239 HF(Rated 20kV) HV GND(Braided shield) Vinyl sheath Cable length: 500mm 180 170 160 100 4-φ 4.5×6 1Pin 8Pin Output cable Input connector Input connector on power supply side: B8PS-VH(JST) Recommended connector on wiring side: VHR-8N (JST) NHV24-10K700P HIGH VOLTAGE DC-DC CONVERTER Bellnixr Input +22.8 ~ +25.2V Output 0 ~10kV 700uA XXX HV OUT 1. Vin 2. PGND 3. SGND 4. Vcont 5. Vref 6. ON/OFF 7. Imoni 8. Vmoni DANGER plate Lot No. indication Display plate for input connector terminal name DANGERHIGH VOLTAGE Main name plate (Model, company name, input/output specification, Lot No.) Display plate for output terminal name 【Lot No. indication】 2 8
2 D 2
Production code (may not be indicated ) Manufacturing month (Jan-Sep=1-9, Oct=O, Nov=N, Dec=D) Manufacturing year (the last digit of A .D.) (Manufactured in December 2012) (Manufactured in August 2012) 6. Description of input connector terminals No. Name Function
1 Vin Input terminal (+ Vin)
2 PGND Input GND terminal (- Vin)
3 SGND Terminal for output voltage control ( - )
4 Vcont Terminal for output voltage control ( + )
5 Vref Reference voltage output terminal
6 ON/OFF Terminal for ON/OFF control
7 Imoni Terminal for output current monitoring
8 Vmoni Terminal for output voltage monitoring
Unit: mm nomi.
High Accuracy, Low Noise Mid -to-High Voltage DC -DC Converter 10,000V, 15,000V NHV Series DC-DC Converter BHV20170526_B01 7. Standard connection PGND SGND Vcont Vin Vref Vmoni Imoni ON/OFF SW Short : ON Open : OFF V V LOAD +24V 0 ~ 10V 0 ~ 10V 0 ~ 10V Output cable 10V Casing HV GND HV OUT 8. Functions 8-1 Adjustable output voltage Output voltage can be set by applying 0 to 10V between the terminal s for output voltage control , the Vcont (4Pin) and SGND (3Pin). Avoid setting out of the adjustable output voltage range or it may cause trouble. 8-2 Monitoring output voltage and output current Output current monitoring terminal, the Imon i (7pin) and output voltage monitoring terminal, the Vmoni (8pin) generate 0 - 10V proportionate to output of the converter. An internal impedance of each terminal for monitoring is 1kohm . The internal impedance of each terminal for monitoring is 1kΩ. Do not allow monitoring current to exceed 2mA PGND, SGND, casing and HV GND are connected inside. Output voltage – Vcont volage characteristic 100% 75% 50% 25% 10V7.5V5V2.5V Vcont voltage Output voltage(% NHV Vcont SGND 0~10V NHV Vmoni SGND 1KΩ
7 Imoni
1KΩVV Monitor voltage – Output voltage/Output current characteristic 25%0% Output voltage/Output current(%) Monitor voltage 2.5V 7.5V 10V 50% 75% 100%
High Accuracy, Low Noise Mid -to-High Voltage DC -DC Converter 10,000V, 15,000V NHV Series DC-DC Converter BHV20170526_B01 8-3 Reference voltage Reference voltage output terminal, the Vref (5pin) generates reference voltage of 10V. This terminal is used when controlling output voltage by a variable resistor ( 5kΩ min.). L eave this terminal open when output voltage is adjusted by external voltage. Do not allow reference current to exceed 2mA. 8-4 Overcurrent protection If output current becomes 105% or more of the rated current value, over current protection (OCP) functions to lower the output voltage. Si nce this over current protection is an auto restart type, output will resume upon release of the overcurrent state. 8-5 ON/OFF control Output voltage can be turned ON/OFF by open ing or short -circuiting between the ON/OFF (6Pin) and the SGND (3Pin) without turning on/off the input voltage. In the case of not using the ON/OFF control, short-circuit these two terminals. Use an open collector type. ・Open between 6 and 3 (6V max.): Output Off ・Short between 6 and 3 (0 – 0.3V, 2mA max.): Output On 8-6 Thermal shutdown This function works upon the abnormal rise of the ambient temperature or the temperature inside this power supply to stop the oscillation of the converter and the supply of out put power. If the t hermal shutdown functioned, shut down the input and wait some time for the temperature to come down sufficiently (after eliminating the cause) before reclosing. NHV SGND
4 Vcont
(10V) VR 100% 80% 60% 40% 20% Output voltage – VR resistance characteristic VR resistanceR1 max.Ω R2 0kΩ 0kΩ max.Ω Output voltage(%
High Accuracy, Low Noise Mid -to-High Voltage DC -DC Converter 10,000V, 15,000V NHV Series DC-DC Converter BHV20170526_B01 9. Environmental specifications This product is RoHS compliant. 10. Precautions for use To ensure user’s safety, check specifications before using the product and always observe the following precautions for use. This product is intended for use in general electronics equipment. Do not use the product for medical equipment, nuclear equipment, trains, etc., whereby human life or property may be directly affected by a damaged product. Consult with us for any use other than for such general electronics equipment. This product is not suitable for series operation and parallel operation. This equipment has a built -in over current protection circuit but avoid a prolonged over current state which may lead to failure. This product may be damaged if used under nonstandard electrical conditions or nonstandard environmental conditions including temperature. Ensure use within the standards. Avoid using this product in a place that generates corrosive gas or is dusty. This product may be damaged by static electricity. Make sure that the workplace is guarded against static buildup and static electricity on operators by use of proper grounding. A fuse mechanism is not built in this product. Connect a fuse to the + input line to guard against excessive input current under abnormal circumstances. Allow enough capacity in the power supply for a fuse to blow. This product does not come with a test report. 11. Warranty The warranty term of the product is one year after shipment. Should the product becomes defective within the warranty period due to our design or workmanship, the product will be repa ired free of charge or replaced. However, this warranty does not cover products which have been subjected to unaut horized inner modifications. The scope of our warranty is limited to that of the said product. 12. Contact If you have any further technical questions for this product, please contact us. E-mail: info@bellnix.com URL: http://www.bellnix.com