5V Analog Front End with High Gain PGA - 1 - Ver.1.1 FEATURES GENERAL DESCRIPTION ⚫ Supply Voltage +2.7V to +5.5V ⚫ Ambient Operating Temperature -40°C to 125°C ⚫ ADC Resolution 16-Bit (No missing codes) ⚫ Data Rate 0.814k to 6.51ksps(1) ⚫ Input mode Differential : 2 inputs Single-ended (2) : 4inputs Pseudo-differential (3) ⚫ PGA 1V/V to 512V/V ⚫ System Calibration for offset & gain drift ⚫ Built-in Regulator ⚫ Current Consumption Normal Mode 4mA Low Power Mode 1.3mA ⚫ Conversion mode Single / Continuous ⚫ Excitation Current Source 2 systems (0.1mA, 0.25mA, 0.5mA, 1.0mA) ⚫ Interface SPI ⚫ CS (Chip Select) ⚫ Error detection CRC8, Check Sum ⚫ Package SSOP-16-BD NA2200 is a CMOS-based 5V AFE with up to 512 times internal PGA (Programmable Gain Amplifier). Internal 16-bit ΔΣ type Analog to Digital converter (ADC) can perform conversion rates from 0.814ksps to 6.51ksps. The customer can choose internal Analog to Digital converter’s input, among differential input, single-ended input and pseudo-differential input. NA2200 can set the optimum gain to the pressure sensor, flow sensor by a wide range of gain setting. Various parameters (such as gain, conversion rate, correction) settings can be easily set in the SPI communication from an external MCU. SSOP-16-BD ⚫ Pressure sensors ⚫ Flowmeters ⚫ Current Measurement ⚫ Thermostat ⚫ PLC (1) Case of single conversion. (Continuous conversion is three times the data rate.) (2) PGA2 can be used only. (PGA1 cannot be used.) Four channels of VIN1P, VIN1N, VIN2P & VIN2N can be used. (3) Bias voltage of VIN1P, VIN1N, VIN2P & VIN2N is common to VDD / 2. Input Signal can be used VIN1P and VIN2P only.

APPLICATIONS

  • 2 - Ver.1.1 ■ PRODUCT NAME INFORMATION NA220 0 BD A E2 S Description of configuration Suffix Item Description A Version Product Version. Default is A. E2 Packing Refer to the packing specifications. S Grade Standard ; Indicates the quality grade. Grade Grade Usage Operating Temperature Range Test Temperature S General-purpose and Consumer application −40°C to 125°C 25°C ■ ORDER INFORMATION Product Name Package RoHS Halogen- Free Terminal Finish Weight (mg) Quantity (pcs/reel) NA2200BDAE2S SSOP-16-BD Yes Yes Sn-2Bi 68 2,000
  • 3 - Ver.1.1 ■ PIN DESCRIPTION SSOP-16-BD Pin Configuration Pin No. Pin Name I/O Description

1 VIN1P Analog Input +INPUT 1 for differential mode / INPUT 1 for single-ended mode

2 VIN1N Analog Input -INPUT 1 for differential mode / INPUT 2 for single-ended mode

3 VIN2P Analog Input +INPUT 2 for differential mode / INPUT 3 for single-ended mode

4 VIN2N Analog Input -INPUT 2 for differential mode / INPUT 4 for single-ended mode

5 VREFN Analog Input -Reference Voltage Input

6 VREFP Analog Input +Reference Voltage Input

7 STBY Digital Input Standby Mode

8 VDD Power Supply Supply Voltage

9 GND GND GND

10 GND GND GND

11 REG Analog Output Built-in Regulator for Digital Power Supply (Place a decoupling capacitor

close to 11pin)

12 CSB Digital Input SPI Chip Select

13 SDO / RDYB Digital Output SPI serial data output / RDYB output

14 SDI Digital Input SPI serial data input

15 SCK Digital Input SPI serial clock input

16 NC GND Non Connection (*)

(*)It is recommended to be left open or connected to GND. Please refer to “TYPICAL APPLICATION CIRCUIT“ or “APPLICATION NOTES“ for details.

  • 4 - Ver.1.1 ■ ABSOLUTE MAXIMUM RATINGS Symbol Ratings Unit Power Supply Voltage VDDabso 7.0 (4) V Power Dissipation PD 900 (5) / 1,300 (6) mW Analog Input Voltage VIN -0.3 to (VDD+0.3) (7) V Operating Temperature Range Topr −40 to 125 C Storage Temperature Range Tstg −40 to 150 °C (4) The difference between the absolute maximum power supply voltage and the operating power supply voltage is small. Please be careful so that the operating power supply voltage does not exceed the absolute maximum supply voltage by spike voltage. (5) Mounted on glass epoxy board. (114.3 x 76.2 x 1.57mm: based on EIA/JEDEC standard, 2Layers FR-4.) (6) Mounted on glass epoxy board. (114.3 x 76.2 x 1.6mm: based on EIA/JEDEC standard, 4Layers FR-4.) (7) Input pin is connected to the clamp diode to the power supply pin. When the input signal exceeds the supply rails 0.3V or more (below the GND rail 0.3V or more), the input current must be limited to less than 10mA. ABSOLUTE MAXIMUM RATINGS Electronic and mechanical stress momentarily exceeded absolute maximum ratings may cause permanent damage and may degrade the lifetime and safety for both device and system using the device in the field. The functional operation at or over these absolute maximum ratings is not assured.
  • 5 - Ver.1.1 ■ ELECTRICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS (Analog Input) Unless otherwise specified, all limits ensured for Ta = +25°C, VDD = 5.0V, GND = 0V, VREFP = 0.5 x VDD, VREFN = 0V, PGAIN1 = PGAIN2 = 1, VCIN2 = 0.5 x VDD, DR = 0.814ksps or 1.63ksps Parameter Symbol Conditions MIN. TYP. MAX. Unit Analog Input 1 (PGA1 = unused, PGA2 = used, PGAIN2 = 1 or 4) Differential Input Voltage Range 1 VDIN1 - ±VREF / (PGAIN2) - V Common Mode Input Voltage Range 1 VCIN1 GND - VDD V Input Impedance 1 ZIN1 FMOD = 1.25MHz PGAIN2 = 1 - 600 - kΩ FMOD = 1.25MHz PGAIN2 = 4 - 300 - kΩ Common Mode Rejection Ratio 1 CMRR1 PGAIN2 = 1 70 90 - dB Analog Input 2 (PGA1, 2 = used, PGAIN1 = 1 or 2 or 4 or 8 or 16 or 32 or 64 or 128, PGAIN2=1 or 4) Differential Input Voltage Range 2 VDIN2 PGAIN1 ≥ 2 - (±VREF) / (PGAIN1 x PGAIN2) - V Common Mode Input Voltage Range 2 VCIN2 0.1 - VDD -1.2 V Input Impedance 2 ZIN2 - 100 - MΩ Common Mode Rejection Ratio 2 CMRR2 PGAIN1 = 2 PGAIN2 = 1 CHOP = ON 70 90 - dB ELECTRICAL CHARACTERISTICS (Reference Voltage Input) Unless otherwise specified, all limits ensured for Ta = +25°C, VDD = 5.0V, GND = 0V Parameter Symbol Conditions MIN. TYP. MAX. Unit Reference Voltage VREF VREF = VREFP - VREFN 2.0 - VDD V VREFN Input Voltage Range VREFN 0 - VDD -2.5 V Input Impedance 3 ZIN3 FMOD = 1.25MHz PGAIN2 = 1 - 180 - kΩ FMOD = 1.25MHz PGAIN2 = 4 - 250 - kΩ
  • 6 - Ver.1.1 ELECTRICAL CHARACTERISTICS (Internal Regulator) Unless otherwise specified, all limits ensured for Ta = +25°C, VDD = 5.0V, GND = 0V Parameter Symbol Conditions MIN. TYP. MAX. Unit Output Voltage REG 2.376 2.4 2.424 V Temperature Drift REG_TD Ta = 25 to 125℃ (REG125–REG25) / REG25 x - -25 - ppm/℃ (8) REG25 -> Measured value at 25℃. REG125 -> Measured value at 125℃. ELECTRICAL CHARACTERISTICS (Internal Oscillator) Unless otherwise specified, all limits ensured for Ta = +25°C, VDD = 5.0V, GND = 0V Parameter Symbol Conditions MIN. TYP. MAX. Unit OSC Frequency FOSC 2.25 2.5 2.75 MHz ELECTRICAL CHARACTERISTICS (Excitation Current Source) Unless otherwise specified, all limits ensured for Ta = +25°C, VDD = 5.0V, GND = 0V Parameter Symbol Conditions MIN. TYP. MAX. Unit Output Current IEX VINxx = 1.2V - 0.10, 0.25, 0.50, 1.00 - mA Absolute Value Deviation IEX_E (Measured Value – IEX) / IEX x 100 - - ±10 % Matching Error IEX_ME IEX1 = 1mA, (IEX2 - IEX1) / IEX1 x 100 (9) - - ±1 % Temperature Drift IEX_TD Ta = 25 to 125℃ (IEX125 - IEX25) / IEX125 x - -300 - ppm/℃ Temperature Drift Matching Error IEX_TD_ME IEX2_TD - IEX1_TD (11) - ±2 - ppm/℃ (9) IEX1 -> Measured value of Excitation current source 1. IEX2 -> Measured value of Excitation current source 2. (10) IEX25 -> Measured value at 25℃. IEX125 -> Measured value at 125℃. (11) IEX1_TD -> Temperature Drift of Excitation current source 1. IEX2_TD -> Temperature Drift of Excitation current source 2. ELECTRICAL CHARACTERISTICS (Programmable Gain Amplifier) Unless otherwise specified, all limits ensured for Ta = +25°C, VDD = 5.0V, GND = 0V Parameter Symbol Conditions MIN. TYP. MAX. Unit PGA1 Gain PGAIN1 - 1, 2, 4, 8, 16, 32, 64, 128, - V/V PGA2 Gain PGAIN2 - 1, 4 - V/V
  • 7 - Ver.1.1 ELECTRICAL CHARACTERISTICS (Analog to Digital Convertor) Unless otherwise specified, all limits ensured for Ta = +25°C, VDD = 5.0V, GND = 0V, VREFP = 0.5 x VDD, VREFN = 0V, PGAIN1 = PGAIN2 = 1, VCIN2 = 0.5 x VDD Parameter Symbol Conditions MIN. TYP. MAX. Unit Resolution N No missing codes(12) 16 Bit Data Rate DR Single Conversion(13) Normal Mode 0.814k, 1.63k, 3.26k, 6.51k sps Single Conversion(13) Low Power Mode 0.203k, 0.407k, 0.814k, 1.63k Clock Frequency FMOD (MDCK) FMOD = FOSC / 2 1.125 1.25 1.375 MHz Integral Non Linearity INL best-fit-line method(14) VREFP = 5.0V PGAIN1 = 2 - ±30 ±60 ppm Offset Error OE PGAIN1 = 128 CHOP = OFF - ±150 - µV PGAIN1 = 128 CHOP = ON - ±1 ±10 µV Gain Error GE PGAIN1 = 128 Noise Free Bit(12)(15)(16) NFB VDIN2 = 0V VREFP = 5.0V VREFN = 0V DR = 0.814ksps - 15 - Bit VDIN2 = 0V VREFP = 5.0V VREFN = 0V DR = 1.63ksps - 14 - Bit (12) This parameter is not production tested. (13) There is no latency by one settling behavior. (14) Guaranteed by design evaluation and several points test (15) See table of Effective resolution and Noise Free Bit(NFB) (see page 25 to 26). (16) NFB represents the ADC output code variations 6.6σ with the differential input shorted.
  • 8 - Ver.1.1 ELECTRICAL CHARACTERISTICS (Power Supply / Supply Current) Unless otherwise specified, all limits ensured for Ta = +25°C, VDD = 5.0V, GND = 0V Parameter Symbol Conditions MIN. TYP. MAX. Unit Power Supply Voltage VDD 2.7 5.0 5.5 V Supply Current Normal Mode IDD PGA OFF 1.4 2.3 3.3 mA PGA ON 2.7 4.0 5.7 mA Supply Current Low Power Mode IDDLOW PGA OFF 0.6 0.9 1.4 mA PGA ON 0.85 1.3 1.9 mA Supply Current Sleep Mode IDDSLEEP Sleep Mode 0.14 0.27 0.4 mA Supply Current Standby Mode IDDSTBY Standby Mode STBY = VDD Regulator OFF - 0.001 0.1 µA ELECTRICAL CHARACTERISTICS (Digital I/Os) Unless otherwise specified, all limits ensured for Ta = +25°C, VDD = 5.0V, GND = 0V Parameter Symbol Conditions MIN. TYP. MAX. Unit High-level input voltage Vih 0.7 x VDD - - V Low-level input voltage Vil - - 0.2 x VDD V High-level output voltage Voh Ioh max.= 6mA 0.8 x VDD - - V Low-level output voltage Vol Iol max.= 6mA - - 0.4 V
  • 9 - Ver.1.1 ELECTRICAL CHARACTERISTICS (Serial Peripheral Interface) Parameter Symbol MIN. TYP. MAX. Unit SPI clock frequency fsck - - 10 MHz Setup time, CSB falling edge to first SCK rising edge t1 45 - - nsec Hold time, final SCK falling edge to CSB rising edge t2 45 - - nsec Pulse duration, SCK high t3 45 - - nsec Pulse duration, SCK low t4 45 - - nsec Setup time, SDI input data valid before SCK falling edge t5 10 - - nsec Hold time, SDI input data valid after SCK falling edge t6 10 - - nsec Setup time, CSB falling edge to SDO / RDYB output data t7 0 - 30 nsec Setup time, SCK rising edge to SDO / RDYB output data t8 0 - 40 nsec Hold time, SCK falling edge of LSB to SDO / RDYB output data t9 10 - 50 nsec Setup time, CSB rising edge to SDO / RDYB changing to HiZ t10 0 - 30 nsec Reset time trstw - - 400 nsec - The SPI AC timing is shown in the figure below. It is the communication of 10Mbps at the highest speed. - Capacitance Load of SDO / RDYB terminal is assumed to 40pF SPI AC timing t1 t2 t10 t7 t9t8 Hi-Z LSB MSB CSB SCK SDI SDO/RDYB SDO/RDYB=SDOSDO/RDYB=RDYB SDO/RDYB=RDYB Hi-Z MSB LSB
  • 10 - Ver.1.1 ■ REGISTER DESCRIPTION NA2200 has register (list shown below) which can access it through SPI bus. Registers with different data lengths (1 to 3 bytes) are assigned to 4-Bit register address. Register Address Register Name Data Length [byte] 0x0 CTRL 2-Byte (16-Bit) 0x1 ADCDATA 2-Byte (16-Bit) 0x2 IEXCONF 2-Byte (16-Bit) 0x3 PGACONF 1-Byte (8-Bit) 0x4 CLKCONF 1-Byte (8-Bit) 0x5 Not used - 0x6 OPTION0 1-Byte (8-Bit) 0x7 Not used - 0x8 GAIN1 3-Byte (24-Bit) 0x9 GAIN2 3-Byte (24-Bit) 0xA Not used - 0xB Not used - 0xC OFFSET1 3-Byte (24-Bit) 0xD OFFSET2 3-Byte (24-Bit) 0xE Not used - 0xF Not used - < View of the register table> Register Name Bit Name R / W Reset R / W: Bit of attribute (Read or Write) - R (Read Only) : Read only - W (Write Only) : Write only (At the time of read, return "0".) - RW (Read Write) : Read & Write - RC (Read / Write 1 to Clear bit) : Read returns the register value. Writing 1 clears the bit to 0. Writing 0 does not affect the operation. Reset: Reset value in register Set to the reset value by SPI reset command and power-on reset.
  • 11 - Ver.1.1 ■ REGISTER DESCRIPTION CTRL Register Register Address: 0x0 CTRL Bit Name - CHSELN - CHSELP R / W - RW - RW Reset - 0x4 - 0x4 Bit Name RDYCNT RDYB OV MODE R / W R R R RW Reset 0x0 1 0 0x0 Bit Bit Name Function [15] - - [14:12] CHSELN Analog input channel setting of negative side. Refer the below table: CHSELP / CHSELN Register. [11] - - [10:8] CHSELP Analog input channel setting of positive side. Refer the below table: CHSELP / CHSELN Register. [7:6] RDYCNT Modulo operation counter. 2-Bit modulo operation counter that adds 1 each time the ADCDATA resister is updated. [5] RDYB Data ready flag. When conversion data is updated, this bit is set to “0”. When ADCDATA read, this bit set to “1”. 0: Conversion completion 1: Conversion non-completion [4] OV Overflow flag. When conversion data is overflow, this bit is set to “1”. When ADCDATA read, this bit is set to “0”. 0: Valid 1: Overflow (Invalid) [3:0] MODE Operation mode setting. When this bit is “write”, sets the operation mode of ADC. When this bit is “read”, returns the current configuration state. Refer the below table : MODE Register Table 1 CHSELP / CHSELN Bit CHSELP Positive CHSELN Negative 0x0 VIN1P 0x0 VIN1P 0x1 VIN1N 0x1 VIN1N 0x2 VIN2P 0x2 VIN2P 0x3 VIN2N 0x3 VIN2N 0x4 VREFN 0x4 VREFN 0x5 VREFP 0x5 VREFP 0x6 REG 0x6 REG 0x7 GND 0x7 GND
  • 12 - Ver.1.1 Table 2 MODE Bit MODE Operation Processing 0x0 Idle Waiting state of conversion operation or calibration 0x1 Sleep Setting the state of low power consumption which conversion operation or calibration is available. Start-up time is inserted automatically before conversion operation. 0x2 Single conversion Convert once the input channel that is selected in the CHSELP / N. After the conversion, the operation is “Idle (0x0)” state. Using the value of the “OFFSET1, 2” register. 0x3 Continuous conversion Convert continuous the input channel that is selected in the CHSELP / N. Until the operation is set to "Idle (0x0)", conversion will continue. Using the value of the “OFFSET1, 2” register. 0x4 Single conversion + CHOP This is the same as “Single conversion (0x2)”, but the data rate is 1/2. Not using the value of the “OFFSET1, 2” register. 0x5 Continuous conversion + CHOP This is the same as “Continuous conversion (0x3)”, but the data rate is 1/3. Not using the value of the “OFFSET1, 2” register. 0x6 Single conversion + CHOP + IEX CHOP This is the same as “Single conversion (0x2)”, but the data rate is 1/2. Not using the value of the “OFFSET1, 2” register. CHOP operation is valid. The connection channel of IEX1 and IEX2 is switched in conjunction with the CHOP operation. 0x7 Continuous conversion + CHOP + IEX CHOP This is the same as “Continuous conversion (0x3)”, but the data rate is 1/3. Not using the value of the “OFFSET1, 2” register. CHOP operation is valid. The connection channel of IEX1 and IEX2 is switched in conjunction with the CHOP operation. 0x8 Not used(17) - 0x9 Not used(17) - 0xA Not used(17) - 0xB Not used(17) - 0xC Calibration system offset Input is selected by CHSELP / N, system offset is calibrated. 0xD Calibration system gain Input is selected by CHSELP / N, system gain is calibrated. 0xE Not used(17) - 0xF Boot Read only. It shows the state from the reset to change to “Idle (0x0)”. After the initial setting, automatically shifts to the "Idle (0x0)". (17) Please do not absolutely use the “Not used” code. It will be the cause of failure.
  • 13 - Ver.1.1 ADCDATA Register Register Address: 0x1 ADCDATA Bit Name ADCDATA R / W R Reset - Bit Bit Name Function [15:0] ADCDATA Store the converted data of the ADC.(18) Conversion data is expressed as a signed 16-bit. - When the input voltage is negative full-scale, the output is 0x8000 - When the input voltage is zero, the output is 0x0000 - When the input voltage is positive full-scale, the output is 0x7FFF. (in decimal -32768 to +32767) (18) Relationship of conversion data ADCDATA and the analog input voltage Vin is as the following equation. (It assumed that the offset error and gain error are zero.) 1516 2212212 == PGAINPGAINVREF VPGAINPGAINVREF VADCDATA inin
  • 14 - Ver.1.1 IEXCONF Register Register Address: 0x2 IEXCONF Bit Name IEX2SLP IEX2C - IEX2_EN IEX2SEL R / W RW RW - RW RW Reset 0 0x0 - 0 0x0 Bit Name IEX1SLP IEX1C - IEX1_EN IEX1SEL R / W RW RW - RW RW Reset 0 0x0 - 0 0x0 Bit Bit Name Function [15] IEX2SLP Condition setting of IEX2 at sleep mode by AUTOSLP bit = “1” of OPTION0 register. 0: IEX2 current depends on IEX2C 1: IEX2 OFF [14:12] IEX2C Current setting of IEX2. 0x0: 0.10mA 0x1: 0.25mA 0x2: 0.50mA 0x3: 1.00mA 0x4 to 0x7: Not used(17). [11] - - [10] IEX2_EN Setting ON / OFF of IEX2. 0: IEX2 OFF (Open) 1: IEX2 ON [9:8] IEX2SEL Connection setting of IEX2. 0x0: VIN1P 0x1: VIN1N 0x2: VIN2P 0x3: VIN2N (17) Please do not absolutely use the “Not used” code. It will be the cause of failure.
  • 15 - Ver.1.1 Bit Bit Name Function [7] IEX1SLP Condition setting of IEX1 at sleep mode by AUTOSLP bit = “1” of OPTION0 register. 0: IEX1 current depends on IEX1C 1: IEX1 OFF [6:4] IEX1C Current setting of IEX1. 0x0: 0.10mA 0x1: 0.25mA 0x2: 0.50mA 0x3: 1.00mA 0x4 to 0x7: Not used(17). [3] - - [2] IEX1_EN Setting ON / OFF of IEX1. 0: IEX1 OFF (Open) 1: IEX1 ON [1:0] IEX1SEL Connection setting of IEX1. 0x0: VIN1P 0x1: VIN1N 0x2: VIN2P 0x3: VIN2N (17) Please do not absolutely use the “Not used” code. It will be the cause of failure.
  • 16 - Ver.1.1 PGACONF Register Register Address: 0x3 PGACONF Bit Name - - PGA2GAIN - PGA1EN PGA1GAIN R / W - - RW - RW RW Reset - - 0 - 0 0x0 Bit Bit Name Function [7:6] - - [5] PGA2GAIN Gain setting of PGA2. 0: x1 1: x 4 [4] - - [3] PGA1EN Setting ON / OFF of PGA1. 0: PGA1 OFF 1: PGA1 ON [2:0] PGA1GAIN Gain setting of PGA1. 0x0: x1 0x1: x2 0x2: x4 0x3: x8 0x4: x16 0x5: x32 0x6: x64 0x7: x128
  • 17 - Ver.1.1 CLKCONF Register Register Address: 0x4 CLKCONF Bit Name - - CLKDIV - OSR R / W - - RW - RW Reset - - 0x0 - 0x3 Bit Bit Name Function [7:6] - - [5:4] CLKDIV(19) Setting of the ADC operating clock frequency (FMOD). FOSC is the operating clock of the internal OSC. 0x0: FOSC / 2 0x1: FOSC / 4 0x2: FOSC / 8 0x3: FOSC/ 16 [3] - - [2:0] OSR Setting of the oversampling ratio of the digital filter 0x0: 64 0x1: 128 0x2: 256 0x3: 512 0x4 to 0x7: Not used(17) (17) Please do not absolutely use the “Not used” code. It will be the cause of failure. (19) Data rate is derived by the following equation. It will be the data rate of a single conversion. If FOSC is 2.5MHz of (TYP.), Conversion data rate will be set in the table below. OSR Date Rate [sps] CLKDIV=0 (Recommendation) CLKDIV=1(*) CLKDIV=2(*) CLKDIV=3(*) 512 0.814k 0.407k 0.204k 0.102k 256 1.63k 0.814k 0.407k 0.204k 128 3.26k 1.63k 0.814k 0.407k 64 6.51k 3.26k 1.63k 0.814k (*) This parameter is not production tested. ( ) 3 1 = +CLKDIVOSC OSRFDR
  • 18 - Ver.1.1 OPTION0 Register Register Address: 0x6 OPTION0 Bit Name CHIPID LPW_EN REF_INT_EN CEMODE CE AUTOSLP R / W R RW RW RW RC RW Reset 0x2 0 0 0x0 0 0 Bit Bit Name Function [7:6] CHIPID Used to identify the chip. [5] LPW_EN Low power setting. ADC operating clock frequency (FMOD) becomes FMOD = FOSC / 8 regardless of CLKDIV setting. 0: Normal Mode 1: Low Power Mode [4] REF_INT_EN ADC reference voltage setting. 0: External reference voltage VREFP / VREFN 1: Internal reference voltage REF / GND [3:2] CEMODE SPI communication error mode setting. 0: Communication Error function OFF 1: Use prohibition 2: CRC8 3: Check Sum [1] CE The communication error can be detected if CEMODE is set to 2 (CRC8) or 3 (Check Sum). 0: No communication error 1: Communication error (Sticky bit) [0] AUTOSLP When MODE is Idle (0x0), set to ON / OFF of analog block 0: ON (Wait) 1: OFF (Power down) When the customer change AUTOSLP from 1to 0, conversion start is necessary to start-up time of the analog block.
  • 19 - Ver.1.1 GAIN1 / GAIN2 Register Register Address: 0x8, 0x9 GAIN1 / GAIN2 Bit Name GAIN R / W RW Reset 0x00 0x00 0x00 Bit Bit Name Function [23:0] GAIN Gain coefficient derived in gain calibration or the external writing gain coefficient. 18-bit unsigned coefficient, GAIN [23:18] is always "0". The customer can do the external writing gain coefficient, when internal clock is active only. In case of writing gain coefficient, please set to "0" AUTOSLP bit of OPTION0 register. OFFSET1 / OFFSET2 Register Register Address: 0xC, 0xD OFFSET1 / OFFSET2 Bit Name OFFSET R / W RW Reset 0x00 0x00 0x00 Bit Bit Name Function [23:0] OFFSET Offset coefficient derived in offset calibration or the external writing offset coefficient. 20-bit signed coefficient, OFFSET [23:20] is sign-extended value. (20) The customer can do the external writing offset coefficient, when internal clock is active only. In case of writing offset coefficient, please set to "0" AUTOSLP bit of OPTION0 register. (20) Sign - extended: If the sign is (-) fill the 1 in the free space. If the sign is (+) fill the "0" in the free space - In the case of -4 in decimal 8- bit is “11111100”. 16-bit sign extension is “11111111 11111100”. - In the case of +4 in decimal 8-bit is “00000100” 16-bit sign extension is “00000000 00000100” The GAINn and OFFSETn registers are used for the coefficients used in gain and offset calibration. “n” is determined by the setting value on the positive input side, CTRL Register 0x0 CHSELP[10:8]. Refer the below table: Data Calibration Coefficient Correspondence Table 3. Table 3 Data Calibration Coefficient Correspondence Table CHSELP Set Value Positive Gain n Register OFFSET n Register 0x0 VIN1P GAIN1 OFFSET1 0x1 VIN1N GAIN1 OFFSET1 0x2 VIN2P GAIN2 OFFSET2 0x3 VIN2N GAIN2 OFFSET2 0x4 VREFN GAIN1 OFFSET1 0x5 VREFP GAIN1 OFFSET1 0x6 REG GAIN1 OFFSET1 0x7 GND GAIN1 OFFSET1
  • 20 - Ver.1.1 ■ TYPICAL APPLICATION CIRCUIT NA2200 Typical Application Circuit Notes on External Parts Place a decoupling capacitor 0.1µF close to 11pin (REG). A decoupling capacitor should be connected to ground for stability. The regulator is optimized for NA2200 operation, so do not connect any components other than the decoupling capacitor to 11pin(REG). It is recommended that 5pin (VREFN) is connected to ground. The printed circuit board (PCB) layout pattern example of NA2200 is shown below. VDD Bridge circuit MCU 0.814ksps to 6.51ksps NFB=15-Bit@0.814ksps PGAIN2=x1, x4 16-Bit ΔΣ ADC PGA2EMI Filter SW SW VREFP VREFN VIN2N VIN2P VIN1N REG CSB SDO / RDYB SDI SCK PGAIN1=x1, x2, x4, x8, x16, x32, x64, x128 6 11 MUX Digital Filter and Calibration Level Shifter PORInternal Oscilator PGA1 Regurator Interface and Control VDD STBY GND GND VREFP VDD1 VIN1P NC REG VDD REG VDD REG VDD IEX1 IEX2 VDD VREFN VDD VREFP VREFN VIN2N VIN2P VIN1N REG CSB SDO / RDYB SDI SCK VDD STBY GND GND VIN1P NC VREFP VREFN GND
  • 21 - Ver.1.1 ■ BLOCK DIAGRAM NA2200 Block Diagram ■ OPERATING DESCRIPTION The NA2200 uses a PGA (Programmable Gain Amplifier) to amplify analog signals obtained from sensors and other devices connected to the VIN1P / VIN1N / VIN2P / VIN2N input terminals. Combination of PGA1 / PGA2 can amplify signals up to 512 times. The amplified signal is converted to digital data by a 16-Bit ΔΣ ADC, and after signal processing such as offset calibration and gain calibration, the digital signal is output to the MCU via SPI communication. A built-in level shifter outputs digital signals at the VD D level, so it can be connected to a 5V MCU. It supports up to 2 inputs in differential mode and up to 4 inputs in single-ended mode. It has two excitation current sources and can used for temperature controller applications using resistance temperature detectors. The reference voltage source for the ADC can be set to either an external reference voltage VREFP / VREFN input externally or an internal reference voltage REG using an internal regulator. In addition to Normal Mode, Low Power Mode (conversion speed 1/4 and current consumption 1/4 compared to Normal Mode), Sleep Mode (OFF except bias and REG circuit), and Standby Mode (all circuit OFF, current consumption 0.1 μA or less) can be selected. 0.814ksps to 6.51ksps NFB=15-Bit@0.814ksps PGAIN2=x1, x4 16-Bit ΔΣ ADC PGA2EMI Filter SW SW VREFP VREFN VIN2N VIN2P VIN1N REG CSB SDI SCK PGAIN1=x1, x2, x4, x8, x16, x32, x64, x128 6 11 MUX Digital Filter and Calibration Level Shifter PORInternal Oscilator PGA1 Regurator Interface and Control VDD STBY GND GND VREFP VIN1P NC REG VDD REG VDD REG VDD IEX1 IEX2 VDD VREFN SDO / RDYB
  • 22 - Ver.1.1 ■ APPLICATION NOTES ■ TERMINAL DESCRIPTION 1pin (VIN1P), 2pin (VIN1N), 3pin (VIN2P), 4pin (VIN2N), Analog Input terminals, Excitation Current Source Output terminals Analog input terminals for inputting signals from external sources such as sensors. It supports up to 2 inputs in differential mode and up to 4 inputs in single-ended mode. CHSELP and CHSELN in CTRL register 0x0 select the analog input channel for data conversion (built-in multiplexer function). NA2200 has two excitation current sources to provide a constant current to the sensors. IEXCONF register 0x2 selects the analog input channel to which the excitation current source is connected and the current value can be set. 5pin (VREFN), 6pin (VREFP), Reference Voltage Input terminals Reference voltage input terminals. Negative input / positive input are supported. 7pin (STBY), Standby terminal Standby terminal. NA2200 is in Standby Mode when STBY = VDD. 8pin (VDD), Power Supply terminal Power supply terminal. The applied DC voltage range is 2.7V to 5.5V. 9pin (GND), 10pin (GND), Ground terminals Ground terminals of NA2200. 11pin (REG), Built-in regulator output terminal for digital power supply NA2200 has a built-in regulator for digital power supply. 11pin (REG) is the output terminal. A decoupling capacitor should be connected to ground for stability. Place a decoupling capacitor close to 11pin (REG). The regulator is optimized for NA2200 operation, so do not connect any components other than the decoupling capacitor. 12pin (CSB), SPI chip select terminal NA2200 serial interface chip select terminal. It is a digital input terminal. When the CSB terminal is high level, SCK and SDI are disabled and communication is not possible. When the CSB terminal is low level, SCK and SDI are enable and communication is possible. After the CSB terminal changes from high to low level, the state of the SPI slave interface is reset and the command byte must be resent.
  • 23 - Ver.1.1 13pin (SDO/RDYB), SPI serial data output / RDYB terminal NA2200 serial interface data output / RDYB terminal. It is a digital output terminal. When reading, data from the SDO/RDYB terminal is communicated MSB first. SDO/RDYB is synchronized to the rising edge of SCK. The RDYB bit outputs “1” or “0” depending on whether the ADC is converting or not. (1: conversion in progress or 0: conversion completed) 14pin (SDI), SPI serial data input terminal NA2200 serial interface data input terminal. It is a digital input terminal. When writing, data to the SDI terminal is communicated MSB first. SDI is captured on the falling edge of SCK. 15pin (SCK), SPI serial clock input terminal NA2200 serial interface clock input terminal. It is a digital input terminal. 16pin (NC), Non connection Non connection terminal. Ground the terminal.
  • 24 - Ver.1.1 ■ Power up sequence When the power supply pin VDD reaches a voltage at which the circuit can operate, the internal reset is released by the built-in power-on reset circuit and initialization begins. After the reset is released, the startup sequence of the NA2200 is completed after a waiting period of about 600μsec . (The waiting time of about 600μsec does not include the power-on time.) After the startup sequence is completed, the device transitions to the idle state and is ready for AD conversion operation. ■ Effective resolution, Noise Free Bit (NFB) Data Rate (DR) is speed at the time of single conversion (1 settling). Output code variation σ is the effective resolution in the VIN1P and VIN1N (or VIN2P and VIN2N) connected to VDD/2, 6.6σ is the NFB. < Condition > - FMOD=1.25MHz - VDD=5.0V, GND=0V - VREFP=5.0V, VREFN=0V - Differential input - CHOP OFF - Ta=+25°C
  • 25 - Ver.1.1 (1) Normal Mode & External REF DR vs. Effective resolution (Unit: bit) OSR DR [sps] PGA OFF PGA ON x1 x2 x4 x8 X16 x32 x64 x128 x256 x512 512 0.814k 16 16 16 16 16 16 16 16 16 16 16 256 1.63k 16 16 16 16 16 16 16 16 16 16 16 128 3.26k 16 16 16 16 16 16 16 16 16 16 15 DR vs. NFB (Unit: bit) OSR DR [sps] PGA OFF PGA ON x1 x2 x4 x8 x16 x32 x64 x128 x256 x512 512 0.814k 16 16 16 16 16 16 16 16 16 14.5 14 256 1.63k 16 16 16 16 16 16 16 16 16 14.5 14 128 3.26k 14 14 14 14 14 14 14 14 14 13 12.5 (2) Low Power Mode & External REF DR vs. Effective resolution (Unit: bit) OSR DR [sps] PGA OFF PGA ON x1 x2 x4 x8 X16 x32 x64 x128 x256 x512 512 0.203k 16 16 16 16 16 16 16 16 16 16 16 256 0.407k 16 16 16 16 16 16 16 16 16 16 16 128 0.814k 16 16 16 16 16 16 16 16 16 14 14 DR vs. NFB (Unit: bit) OSR DR [sps] PGA OFF PGA ON x1 x2 x4 x8 x16 x32 x64 x128 x256 x512 512 0.203k 16 16 16 16 16 16 16 16 16 14.5 14.5 256 0.407k 16 16 16 16 16 16 16 16 16 14 14 128 0.814k 14 14 14 14 14 14 14 14 14 11.5 11.5
  • 26 - Ver.1.1 (3) Normal Mode & Internal REF DR vs. Effective resolution (Unit: bit) OSR DR [sps] PGA OFF PGA ON x1 x2 x4 x8 X16 x32 x64 x128 x256 x512 512 0.814k 16 16 16 16 16 16 16 16 16 16 16 256 1.63k 16 16 16 16 16 16 16 16 16 16 15.5 128 3.26k 16 16 16 16 16 16 16 16 16 15 15 64 6.51k 14 14 14 14 14 14 14 14 14 12 12 DR vs. NFB (Unit: bit) OSR DR [sps] PGA OFF PGA ON x1 x2 x4 x8 x16 x32 x64 x128 x256 x512 256 1.63k 14 14 14 14 14 14 14 14 14 13 13 128 3.26k 13 13 13 13 13 13 13 13 13 12 12 (4) Low Power Mode & Internal REF DR vs. Effective resolution (Unit: bit) OSR DR [sps] PGA OFF PGA ON x1 x2 x4 x8 X16 x32 x64 x128 x256 x512 512 0.203k 16 16 16 16 16 16 16 16 16 16 16 256 0.407k 16 16 16 16 16 16 16 16 16 16 16 128 0.814k 16 16 16 16 16 16 16 16 16 15 15 64 1.63k 14 14 14 14 14 14 14 14 14 13.5 12.5 DR vs. NFB (Unit: bit) OSR DR [sps] PGA OFF PGA ON x1 x2 x4 x8 x16 x32 x64 x128 x256 x512 256 0.407k 14 14 14 14 14 14 14 14 14 13.5 13 128 0.814k 13 13 13 13 13 13 13 13 13 12.5 12
  • 27 - Ver.1.1 ■ Digital filter frequency characteristic The output of the ΔΣ modulator is converted to a digital value of high resolution by a digital filter (third-order Sinc filter). Frequency characteristics will change depending on the data rate. When the conversion data rate (DR) is 6.51ksps, 3.26ksps, 1.63ksps, 0.814ksps, frequency characteristics of the digital filter is shown below. Characteristic is the case of FMOD=1.25MHz. DR=6.51ksps DR=3.26ksps DR=1.63ksps DR=0.814ksps It has a first notch in the frequency of the data rate x 3. Or later, it has a notch to the integer multiple of the position.(21) (e.x.) In the case 3.26ksps ( Figure of right) Position of the notch 1. 9.8kHz (3.26kHz x 3 x 1) 2. 19.6kHz (3.26kHz x 3 x 2) 3. 29.3kHz (3.26kHz x 3 x 3) 4. 39.1kHz (3.26kHz x 3 x 4) (N) 3.26kHz x 3 x N (N is an integer) DR=3.26ksps (21) Position of the notch varies in proportion to the frequency of the FMOD FMOD is ±10% variation. Position of the notch is likely to vary ±10% from the above figure. -120 -100 -80 -60 -40 -20 0 10000 20000 30000 40000 Gain[dB] Frequency[Hz] 6.51ksps -120 -100 -80 -60 -40 -20 0 10000 20000 30000 40000 Gain[dB] Frequency[Hz] 3.26ksps -120 -100 -80 -60 -40 -20 0 10000 20000 30000 40000 Gain[dB] Frequency[Hz] 1.63ksps -120 -100 -80 -60 -40 -20 0 10000 20000 30000 40000 Gain[dB] Frequency[Hz] 0.814ksps -120 -100 -80 -60 -40 -20 0 10000 20000 30000 40000 Gain[dB] Frequency[Hz] 3.26ksps 1 2 3 4
  • 28 - Ver.1.1 ■ Conversion Control Set the conversion operation by MODE bit of CTRL register. MODE OPERATION 0x0 Idle 0x1 Sleep 0x2 Single conversion 0x3 Continuous conversion 0x4 Single conversion + CHOP 0x5 Continuous conversion + CHOP 0x6 Single conversion + CHOP + IEX CHOP 0x7 Continuous conversion + CHOP + IEX CHOP 0x8, 0x9 0xA, 0xB Not used 0xC Calibration system offset 0xD Calibration system gain 0xE Not used 0xF Boot < Definition of time > (1) ADC conversion time of basic : Tadc (sec) (2) Calculation time for data correction (after ADC conversion) : Tcal (sec) (3) Calculation time for gain coefficient (after gain calibration) : Tdiv (sec) (4) Setup time : Ts When the analog block is ON (AUTOSLP bit of OPTION 0 register = "0"), setting the MODE bit in CTRL register to operation mode starts operation after T s (about 10µsec). The case where the MODE bit is switched from "Idle (0x0)" to "single conversion (0x2)" is shown below. Setup time AUTOSLP=0 Serial Interface Conversion Start ( MODE = 0x2 Write ) MODE 0x20x0 Δ ΣMod+Digital Filter Tadc TadcTs OSR : Over Sampling Rate FMOD : Clock Frequency of ADC FOSC : Clock Frequency of Internal Oscillator Power on Reset Boot MODE = 0xF Sleep MODE = 0x1 Single Conversion Continuous Conversion Offset/Gain Calibration Idle MODE = 0x0 MODE Setting (0xC, 0xD) Calibration End RDYB = 0Conversion End RDYB = 0 MODE Setting (0x3, 0x5, 0x7) MODE Setting (0x2, 0x4, 0x6) MODE Setting (0x0) Conversion End RDYB = 0 SPI Reset AUTOSLP = 1 AUTO SLP = 0 or MODE Setting (0x0) MODE Setting (0x2, 0x4, 0x6) MODE Setting (0x3, 0x5, 0x7) MODE Setting (0xC, 0xD) FMODOSRTadc = FOSCTcal 40= FOSCTdiv 70=
  • 29 - Ver.1.1 (5) Startup wait time : Twu Waiting time of Twu (about 70µsec) is required when changing the analog block from OFF to ON (AUTOSLP bit from "1" to "0"). The figure below shows the case where the MODE bit is switched from "sleep (0x1)" to "single conversion (0x2)". Startup wait time AUTOSLP=1 Serial Interface Conversion Start ( MODE = 0x2 Write ) MODE 0x20x1 Δ ΣMod+Digital Filter TadcTsTwu Tadc
  • 30 - Ver.1.1 Single conversion operation (MODE = 0x2) It is the basic conversion of NA2200. Even if the input signal is switched by the multiplexer (external), waiting time for converted data is unnecessary. (1 settling, zero latency) When the conversion cycle is long, the recommended usage is that converting once and power-down the remaining period. So, the consumption current of NA2200 can be reduced. It is the optimum conversion method for "switching input signals with multiplexer" and "low power consumption". Single conversion timing STEP DETAILS (1) Set to single conversion. (MODE bit in CTRL register = "0x2") (2) After the set-up time (Ts), start the conversion. (3) Conversion completed with conversion time (3 x Tadc). The conversion data is the result of the convolution integration of 3 x Tadc. (ΔΣ Mod + Digital Filter) (4) Data is corrected with calculation time (Tcal). (5) Conversion data stored in ADCDATA register. At that time, RDYB bit changes from "1" to "0". (6) Shift to Idle state. (MODE bit= ”0x0”) In NA2200, the data rate is specified by the following formula. (Single conversion) The conversion data rate (DR) is DR_all when Ts and Tcal are considered. (In the table below, CLKDIV=0) OSR DR [sps] 3xTadc(=1/DR) [sec] 3xTadc+Ts+Tcal [sec] DR_all (=1/(3xTadc+Ts+Tcal)) [sps] 512 0.814k 1.23m 1.26m 0.794k 256 1.63k 0.614m 0.640m 1.56k 128 3.26k 0.307m 0.333m 3.00k 64 6.51k 0.154m 0.180m 5.56k Δ ΣMod+Digital Filter Conversion Start ( MODE = 0x2 Write ) Data Correction RDYB Conversion DataADCDATA Serial Interface Ts TadcTadc Tadc Tcal MODE 0x20x0 0x0 (1) (2) (3) (5) (4) (6) Time ( ) 3 1 = +CLKDIVOSC OSRFDR
  • 31 - Ver.1.1 “Single conversion + CHOP” operation (MODE = 0x4) Single conversion performs single conversion twice. By change VINxP and VINxN at the second conversion, the NA2200 offset can be removed in real time. The change of VINxP and VINxN is done automatically by the internal switch. With single conversion, it is the optimum conversion method for "when you want to calibrate the offset in real time". Though, the data rate is half of single conversion. Single conversion + CHOP timing STEP DETAILS (1) Set to single conversion + CHOP. (MODE bit in CTRL register = "0x4") (2) After the set-up time (Ts), start the conversion. (3) Conversion completed in conversion time (6 x Tadc). The conversion data is the result of the convolution integration of 6 x Tadc. (1st & 2nd conversion of "ΔΣ Mod + Digital Filter".) (4) Data is corrected in calculation time (Tcal). (5) Conversion data stored in ADCDATA register. At that time, RDYB bit changes from "1" to "0". (6) Shift to Idle state. (MODE bit= ”0x0”) Conversion Start ( MODE = 0x4 Write ) Serial Interface RDYB Δ ΣMod+Digital Filter Ts TadcTadc Tadc Tadc Tadc Tadc TcalData Correction MODE 0x40x0 0x0 Conversion DataADCDATA (1) (2) (3) (5) (4) (6) Time 1st Conversion 2nd Conversion
  • 32 - Ver.1.1 “Single conversion + CHOP + IEX CHOP” operation (MODE = 0x6) Single conversion performs single conversion twice. By change VINxP and VINxN at the second conversion, the NA2200 offset can be removed in real time. The change of VINxP and VINxN is done automatically by the internal switch. The excitation current setting is automatically switched in conjunction with the CHOP operation. With single conversion, it is the optimum conversion method for "when you want to measure 3-wire RTD with high accuracy". Though, the data rate is half of single conversion. Single conversion + CHOP + IEX CHOP timing STEP DETAILS (1) Set to single conversion + CHOP + IEX CHOP. (MODE bit in CTRL register = "0x6") (2) After the set-up time (Ts), start the conversion. (3) The setting IEX1SEL / IEX2SEL of the excitation current source is switched in conjunction with the CHOP operation that switches the input polarity in the second conversion. (4) Conversion completed in conversion time (6 x Tadc). The conversion data is the result of the convolution integration of 6 x Tadc. (1st & 2nd conversion of "ΔΣ Mod + Digital Filter".) (5) Data is corrected in calculation time (Tcal). (6) Conversion data stored in ADCDATA register. At that time, RDYB bit changes from "1" to "0". (7) Shift to Idle state. (MODE bit= ”0x0”) Conversion Start ( MODE = 0x6 Write ) RDYB Conversion DataADCDATA 1st Conversion 2nd Conversion Δ ΣMod+Digital Filter Ts TadcTadc Tadc Tadc Tadc Tadc TcalData Correction MODE 0x60x0 0x0 0 1 0IEX1SEL (Internal) 1 1IEX2SEL (Internal) Serial Interface (1) (2) (4) (6) (5) (7) Time (3)
  • 33 - Ver.1.1 Continuous conversion operation (MODE = 0x3) When input signals are switched by the multiplexer, the same waiting time as the first conversion (conversion A) is required. When input signal is not switched by multiplexer, wait time after the second conversion (conversion B) is unnecessary. It is the optimum conversion method for "when input is not switched by multiplexer" and "when you want to maximize data rate". The data rate is three times that of single conversion. Continuous conversion timing STEP DETAILS (1) Set to continuous conversion. (MODE bit in CTRL register = "0x3") (2) After the set-up time (Ts), start the conversion. (3) Conversion A (1st) completed in conversion time (3 x Tadc). The conversion data A is the result of the convolution integration of conversion A (“3 x Tadc” of ΔΣ Mod + Digital Filter”) (4) Data is corrected in calculation time (Tcal) (5) Conversion data A (1st) stored in ADCDATA register. At that time, RDYB bit changes from "1" to "0". (6) After completion of conversion B (2nd), RDYB bit changes from "0" to "1". The conversion data B is the result of the convolution integration of conversion B (“3 x Tadc” of ΔΣ Mod + Digital Filter) (7) Data is corrected in calculation time (Tcal). (8) Conversion data B (2nd) stored (overwrite) in ADCDATA register. At that time, RDYB bit changes from "1" to "0". Repeat steps (5) to (8) until the operation mode is set to idle (MODE bit is set to "0x0"). Δ ΣMod+Digital Filter Serial Interface Conversion Start ( MODE = 0x3 Write ) Ts TadcTadc MODE Tadc Data Correction RDYB ADCDATA Tadc Tadc Tadc Conversion A Conversion B Conversion C Tcal Tcal Tcal 0x30x0 Conversion Data A Conversion Data B Conversion Data C (4) (7) Tadc
  • 34 - Ver.1.1 “Continuous conversion + CHOP” operation (MODE = 0x5) By changing VINxP and VINxN every "3 x Tadc", the NA2200 offset can be removed in real time. The change of VINxP and VINxN is done automatically by the internal switch. When input signals are switched by the multiplexer, the same waiting time as the first conversion (conversion A) is required. When input signal is not switched by multiplexer, wait time after the second conversion (conversion B) is unnecessary. As with “single conversion + CHOP” operation, offset of whole chip can be calibrated in real time. It is the optimal conversion method for "when you want to calibrate offsets in real time" with continuous conversion. Though, the data rate is 1/3 of continuous conversion. (Same data rate as single conversion) Continuous conversion + CHOP timing STEP DETAILS (1) Set to continuous conversion + CHOP. (MODE bit in CTRL register = "0x5") (2) After the set-up time (Ts), start the conversion. (3) Conversion A (1st) completed in conversion time (6 x Tadc). The conversion data A is the result of the convolution integration of conversion A (“6 x Tadc” of ΔΣ Mod + Digital Filter”) (4) Data is corrected in calculation time (Tcal). (5) Conversion data A (1st) stored in ADCDATA register. At that time, RDYB bit changes from "1" to "0". (6) After completion of conversion B (2nd), RDYB bit changes from "0" to "1". The conversion data B is the result of the convolution integration of conversion B (“6 x Tadc” of ΔΣ Mod + Digital Filter) (7) Data is corrected in calculation time (Tcal). (8) Conversion data B (2nd) stored (overwrite) in ADCDATA register. At that time, RDYB bit changes from "1" to "0". Repeat steps (5) to (8) until the operation mode is set to idle (MODE bit is set to "0x0"). Conversion Data B TsΔ ΣMod+Digital Filter Serial Interface Conversion Start ( MODE = 0x5 Write ) Data Correction Conversion A TadcTadc Tadc Tadc Tadc Tadc Tadc Tadc Tadc Tadc Conversion B RDYB Tcal Tcal MODE 0x50x0 Conversion Data AADCDATA (4) 3 x Tadc
  • 35 - Ver.1.1 “Continuous conversion + CHOP + IEX CHOP” operation (MODE = 0x7) By changing VINxP and VINxN every "3 x Tadc", the NA2200 offset can be removed in real time. The change of VINxP and VINxN is done automatically by the internal switch. The excitation current setting is automatically switched in conjunction with the CHOP operation. When input signals are switched by the multiplexer, the same waiting time as the first conversion (conversion A) is required. When input signal is not switched by multiplexer, wait time after the second conversion (conversion B) is unnecessary. As with “single conversion + CHOP” operation, offset of whole chip can be calibrated in real time. Continuous conversion + CHOP +IEX CHOP timing STEP DETAILS (1) Set to continuous conversion + CHOP + IEX CHOP. (MODE bit in CTRL register = "0x7") (2) After the set-up time (Ts), start the conversion. (3) The setting IEX1SEL / IEX2SEL of the excitation current source is switched in conjunction with the CHOP operation that switches the input polarity in the conversion time (3 x Tadc). (4) Conversion A (1st) completed in conversion time (6 x Tadc). The conversion data A is the result of the convolution integration of conversion A (“6 x Tadc” of ΔΣ Mod + Digital Filter”) (5) Data is corrected in calculation time (Tcal). (6) Conversion data A (1st) stored in ADCDATA register. At that time, RDYB bit changes from "1" to "0". (7) After completion of conversion B (2nd), RDYB bit changes from "0" to "1". The conversion data B is the result of the convolution integration of conversion B (“6 x Tadc” of ΔΣ Mod + Digital Filter) The setting IEX1SEL / IEX2SEL of the excitation current source is switched. (8) Data is corrected in calculation time (Tcal). (9) Conversion data B (2nd) stored (overwrite) in ADCDATA register. At that time, RDYB bit changes from "1" to "0". Repeat steps (6) to (9) until the operation mode is set to idle (MODE bit is set to "0x0"). With continuous conversion, it is the optimum conversion method for "when you want to measure 3 -wire RTD with high accuracy". Though, the data rate is 1/3 of continuous conversion. (Same data rate as single conversion) Tcal Δ ΣMod+Digital Filter Serial Interface Conversion Start ( MODE = 0x7 Write ) Data Correction RDYB ADCDATA MODE 0x70x0 Conversion A Conversion B Ts TadcTadc Tadc Tadc Tadc Tadc Tadc Tadc Tadc Tadc Tcal Conversion Data A Conversion Data B 0 1 0IEX1SEL (Internal) 1 1 0 1IEX2SEL (Internal) 0 (5) (8) 3 x Tadc (3)
  • 36 - Ver.1.1 Offset calibration operation (MODE = 0xC) Timing is almost the same as single conversion operation. Calculate the offset amount and save it in the OFFSET register (OFFSET1, OFFSET2). Offset calibration timing STEP DETAILS (1) Set to offset calibration. (MODE bit in CTRL register = “0xC”) (2) After the set-up time (Ts), start the conversion. (3) Conversion is complete in conversion time (3 xTadc). (4) Conversion data stored in OFFSET register (OFFSET1, OFFSET2). At that time, RDYB bit changes from "1" to "0". (5) Shift to Idle state. (MODE bit= ”0x0”) Δ ΣMod+Digital Filter Serial Interface RDYB Conversion Start ( MODE = 0xC Write ) Ts TadcTadc Tadc MODE 0x0 0xC 0x0 OFFSET OFFSET (1) (2) (3) (4) (5) Time
  • 37 - Ver.1.1 For offset calibration, use the CHSELP / CHSELN bits in the CTRL register to select the input channel. In addition, select the REF_INT_EN bit in the OPTION0 register. When the offset calibration command is executed, the following processing is automatically performed. ・ Using the input channel selected by the CHSELP / CHSELN bit, AD conversion is performed with the reference voltage source of the ADC selected by the REF_INT_EN bit of the OPTION0 register, and the offset is calculated. ・ Store calculated offset in OFFSET registers. The example of internal ADC offset calibration. (1) REF_INT_EN = 0 (ADC reference voltage = external reference VREFP / VREFN used) When setting the following PGA gains and input channels, and the offset calibration command is executed, the offset calibration is performed. ・ Set PGA1 to OFF (PGA1EN = 0x0) and set the PGA2 gain to “x1” (PGA2GAIN = 0x0). ・ Applying VREFN internally to the positive and negative inputs of the ADC. (CHSELP = 0x4, CHSELN = 0x4) ・ Calculate the offset. ・ Store calculated offset in OFFSET registers. (2) REF_INT_EN = 1 (ADC reference voltage = internal reference REG / GMD used) When setting the following PGA gains and input channels, and the offset calibration command is executed, the offset calibration is performed. ・ Set PGA1 to OFF (PGA1EN = 0x0) and set the PGA2 gain to “x1” (PGA2GAIN = 0x0). ・ Applying GND internally to the positive and negative inputs of the ADC. (CHSELP = 0x7, CHSELN = 0x7) ・ Calculate the offset. ・ Store calculated offset in OFFSET registers.
  • 38 - Ver.1.1 Gain calibration operation (MODE = 0xD) Timing is almost the same as “single conversion + CHOP” operation. Calculate the gain factor and save it in the GAIN register (GAIN1, GAIN2). Gain calibration timing STEP DETAILS (1) Set to gain calibration. (MODE bit in CTRL register = “0xD”) (2) After the set-up time (Ts), start the conversion. (3) Conversion is complete in conversion time (6 xTadc). (4) The slope (gain) coefficient is calculated in the gain coefficient calculation time (Tdiv). (5) The GAIN registers (GAIN 1, GAIN 2) are updated. At that time, RDYB bit changes from "1" to "0". (6) Shift to Idle state. (MODE bit= ”0x0”) Δ ΣMod+Digital Filter Serial Interface Conversion Start ( MODE = 0xD Write ) TadcTadc Tadc RDYB GAIN Tadc Tadc TadcTs Data Correction Tdiv MODE 0xD0x0 0x0 GAIN (1) (2) Time(3) (4) (6) (5)
  • 39 - Ver.1.1 For gain calibration, use the CHSELP / CHSELN bits in the CTRL register to select the input channel. In addition, select the REF_INT_EN bit in the OPTION0 register. When the gain calibration command is executed, the following processing is automatically performed. ・ Using the input channel selected by the CHSELP / CHSELN bit, AD conversion is performed with the reference voltage source of the ADC selected by the REF_INT_EN bit of the OPTION0 register, and the gain coefficient is calculated. ・ Store calculated gain coefficient in GAIN registers. The example of internal ADC gain calibration. (3) REF_INT_EN = 0 (ADC reference voltage = external reference VREFP / VREFN used) When setting the following PGA gains and input channels, and the gain calibration command is executed, the gain calibration is performed. ・ Set PGA1 to OFF (PGA1EN = 0x0) and set the PGA2 gain to “x1” (PGA2GAIN = 0x0). ・ Applying VREF internally to the positive and negative inputs of the ADC. (CHSELP = 0x5(VREFP), CHSELN = 0x4(VREFN)) ・ Calculate the gain coefficient. ・ Store calculated gain coefficient in GAIN registers. (4) REF_INT_EN = 1 (ADC reference voltage = internal reference REG / GMD used) When setting the following PGA gains and input channels, and the gain calibration command is executed, the gain calibration is performed. ・ Set PGA1 to OFF (PGA1EN = 0x0) and set the PGA2 gain to “x1” (PGA2GAIN = 0x0). ・ Applying REG and GND internally to the positive and negative inputs of the ADC. (CHSELP = 0x6(REG), CHSELN = 0x7(GND)) ・ Calculate the gain coefficient. ・ Store calculated gain coefficient in GAIN registers.
  • 40 - Ver.1.1 ■ Data calibration flow / Combination of conversion operation and calibration operation "Data calibration flow" and "Combination of conversion operation and calibration operation" are explained. Single conversion or Continuous conversion The figure below is a calibration flow block diagram of "single conversion" or "continuous conversion". The offset calibration uses the value of the OFFSET register (OFFSET1, OFFSET2). The gain calibration uses the values of the GAIN register (GAIN1, GAIN2). STEP DETAILS (1) "Input" is the following value for the input voltage Vin. The full scale of the digital filter is eight times signed 16 bits (262144 = 32768 x 8). (2) Subtract "OFFSET" calculated by offset calibration operation from "Input". (3) Multiply the result of step (2) by "GAIN" calculated by the gain calibration operation. In order to convert to signed 16-bit full scale, 1 / (0x80000) = 1 / (32768 x 8) is also multiplied. (4) Confirm whether "-32768 ≤ (3) result ≤ +32768" is satisfied. If it is not satisfied, set the OV bit of the CTRL register to "1". If it is satisfied, set the OV bit of the CTRL register to "0". (5) Store the calculation result in the ADCDATA register. If "OV=1" in step (4), the ADCDATA register is the minimum value (-32768) or the maximum value (+32767). (Example) When applying PGAIN1 = PGAIN2 = 1, OFFSET = 0, GAIN = 0x10000, VREF = 3.3V, Vin = 1V, --> ADCDATA code is "9930".(22) (22) When thinking of NA2200 as a black box, it is intuitively understood that it is correct. PGA1 PGA2 ADC Digital Filter OFFSET GAIN limit to 16-bit signed data VINP VINN ADCDATA 0x80000 Input Vin PGAIN1 PGAIN2 (1) (2) (3) (5) (4) 26214421 = PGAINPGAINVREF VInput in ( ) 80000026214421800000 x GAINOFFSETPGAINPGAINVREF V x GAINOFFSETInputADCDATA in   9930800000 1000000262144113.3 1 =  x V VADCDATA 993032768113.3 VPGAINPGAINVREF VADCDATA in
  • 41 - Ver.1.1 “Single conversion + CHOP” or “Continuous conversion + CHOP” The figure below is a block diagram of the calibration flow of "single conversion + CHOP" or "continuous conversion + CHOP". Since offset is removed by CHOP operation, the offset register value is not used for offset calibration. Otherwise, it is the same operation as "1. Single conversion or Continuous conversion" on the previous page. “Single conversion + CHOP + IEX CHOP” or “Continuous conversion + CHOP + IEX CHOP” “Single conversion + CHOP + IEX CHOP” or “Continuous conversion + CHOP + IEX CHOP” replaces the excitation current source in conjunction with CHOP operation Otherwise, it is the same operation as "2. Single conversion + CHOP or Continuous conversion + CHOP". PGA1 PGA2 ADC Digital Filter GAIN limit to 16-bit signed data VINP VINN ADCDATA 0x80000 Vin PGAIN1 PGAIN2 Input
  • 42 - Ver.1.1 ■ SPI Interface The interface is 4-wire SPI communication of CSB, SCK, SDI, SDO / RDYB. In case, CSB fixed to GND, NA2200 can use as 3-wire SPI communication device. When CSB is “1”, SCK and SDI are invalid. SDO / RDYB becomes high impedance. After CSB changes from “1” to “0”, SPI communication always starts with a command byte. When CSB is “0”, SCK and SDI become valid and these can communicate. SDI is captured on the falling edge of SCK and SDO / RDYB is synchronized with the rising edge of SCK. Bits are transferred in order from the MSB. SPI communication is performed as follows. Step Details (1) Command byte transfer (2) Read or write data transfer (1 byte or 2 byte or 3 byte data transfer) When the data transfer is completed, it waits for the command byte. When SPI communication is not in progress, the RDYB bit value of the CTRL register is output from SDO / RDYB. RDYB bit outputs "1" or "0" depending on the ADC operation state. (1: Conversion in progress, 0: Conversion end) The above state is supplied from the NA2200 to the master device (microcomputer and others). Therefore, the master device can confirm the conversion end without monitoring the NA2200 periodically. < Reading > < Writing > SPI communication format Read Command SCK SDI XA[2] A[1] A[0] R 0 00 X CE RDYCNT[1:0] RDYB OV Data MSB Data LSB SDO/RDYB=RDYBSDO/RDYB=RDYB SDO/RDYB X A[3] Command Byte Transfer Read Data Transfer ( 1 To 3 Byte ) SCK Data MSB Data LSB XA[3] A[2] A[1] A[0]XSDI SDO/RDYB RDYCNT[1:0] RDYB OVCE SDO/RDYB=RDYB SDO/RDYB=RDYB W 0 00 Command Byte Transfer Write Data Transfer ( 1 To 3 Byte )
  • 43 - Ver.1.1 SPI command byte Read command (Byte) BIT NAME - - - CE RDYCNT RDYB OV R / W - - - R R R R VALUE 0 0 0 - - - - BIT BIT NAME FUNCTION [7:5] - - [4] CE Returns the same value as the CE bit of the OPTION0 register [3:2] RDYCNT Returns the same value as the RDYCNT bit of the CTRL register [1] RDYB Returns the same value as the RDYB bit of the CTRL register [0] OV Returns the same value as the OV bit of the CTRL register Write command (Byte) BIT NAME A RW ZERO R / W W W W VALUE - - 0 BIT BIT NAME FUNCTION [7:4] A Specify the register address to be accessed. [3] RW Specify the direction of communication. (Write or Read) 0: Write 1: Read [2:0] ZERO Always write "0" Reading Writing Write Command SCK A[3] A[2] A[1] A[0]XSDI SDO/RDYB RDYCNT[1:0] RDYB OVCE SDO/RDYB=RDYB 0 00W Command Byte Transfer Read Command SCK SDI X A[3] A[2] A[1] A[0] R 0 00 CE RDYCNT[1:0] RDYB OV SDO/RDYB=RDYB SDO/RDYB Command Byte Transfer
  • 44 - Ver.1.1 SPI communication error detection SPI communication error detection is valid, in case CEMODE bit of the OPTION0 register (Register address: 0x6) sets to CRC8 mode or Check Sum mode. When the communication error detection is enable, one byte of Error check byte is added after read or write data transfer. Read mode NA2200 outputs the error check byte, after calculating CRC8 or Check Sum from command byte and reading data. SPI master device such as microprocessor examines error check byte, and please confirm the accuracy of the reading data. SPI communication format with error check byte: Reading Write mode Write the data by adding CRC8 or Check Sum to the command byte and the writing data bytes. NA2200 examines the error check byte, and writes the data if it has no error. In case error detects, CE bit is set to “1”, and the writing data is canceled. SPI communication format with error check byte: Writing Read Command SCK SDI A[3] A[2] A[1] A[0] XR 0 00 X CE RDYCNT[1:0] RDYB OV Data MSB Data LSB SDO/RDYB=RDYBSDO/RDYB=RDYB SDO/RDYB LSBMSB Generate Check Byte CRC8 or Check Sum X Command Byte Transfer Read Data Transfer ( 1 To 3 Byte ) Error Check Byte X Data LSB SDO/RDYB=RDYB LSBMSB Generate Check Byte CRC8 or Check Sum Error Check Byte X Write Command SCK Data MSBA[3] A[2] A[1] A[0] Data LSBXSDI SDO/RDYB RDYCNT[1:0] RDYB OVCE SDO/RDYB=RDYB 0 00W LSBMSB XCRC8 or Check Sum Generate Check Byte SDO/RDYB=RDYB Command Byte Transfer Write Data Transfer ( 1 To 3 Byte ) Error Check Byte SDO/RDYB=RDYB Data LSB LSBMSB XCRC8 or Check Sum Generate Check Byte Error Check Byte
  • 45 - Ver.1.1 CRC8 mode Generally, CRC has a stronger error check function than Check Sum, though it has a large MCU source because of a complex calculation. Error check byte with CRC8 mode is CRC-8-ATM (x8+x2+x+1). Initial value is 0xFF. In case data has 3 bytes, calculating as follow. Step Description (1) It takes Ex-OR of “MSB byte of data” and ”Initial value: 0xFF”. (MSB: Most Significant Bit, XOR: Exclusive OR) (2) If MSB of the result (1) is “1”, shift the data 1 bit to the left. And takes XOR of it and “00000111”. or If MSB of the result (1) is “0”, shift the data 1 bit to the left. (3) If MSB of the result (2) is “1”, shift the data 1 bit to the left. And takes XOR of it and “00000111”. or If MSB of the result (2) is “0”, shift the data 1 bit to the left. (4) Repeat the step (3) six times. (from (2) to (4), shift the data 1 bit to the left eight times) (5) It takes XOR of “the result (4)” and ”middle byte of data”. (6) If MSB of the result (5) is “1”, shift the data 1 bit to the left. And takes XOR of it and “00000111”. or If MSB of the result (5) is “0”, shift the data 1 bit to the left. (7) If MSB of the result (6) is “1”, shift the data 1 bit to the left. And takes XOR of it and “00000111”. or If MSB of the result (6) is “0”, shift the data 1 bit to the left. (8) Repeat the step (7) six times. (from (6) to (8), shift the data 1 bit to the left eight times) (9) It takes XOR of “the result (8)” and ”LSB byte of data”. (LSB: Least Significant Bit) (10) If MSB of the result (9) is “1”, shift the data 1 bit to the left. And takes XOR of it and “00000111”. or If MSB of the result (9) is “0”, shift the data 1 bit to the left. (11) If MSB of the result (10) is “1”, shift the data 1 bit to the left. And takes XOR of it and “00000111”. or If MSB of the result (10) is “0”, shift the data 1 bit to the left. (12) Repeat the step (11) six times. (from (9) to (11), shift the data 1 bit to the left eight times) The calculation of CRC8 is finished.
  • 46 - Ver.1.1 The calculation method is shown as below. The below is considered as the calculation method when the writing data is “0x201012”. (Register Address is set to “0x2”, and writing data is set to “0x1012” in the IEXCONF register.) Writing data: 00100000 00010000 00010010 (0x201012) Initial value: 11111111 (0xFF) Step (1) MSB of Writing data 00100000 (0x20) Initial value 11111111 (0xFF) XOR 11011111 Step (2) If MSB of result (1) is “1”, shifts it 1bit to the left 10111110 (1st time) Polynomial 00000111 XOR 10111001 Step (3) If MSB of result (2) is “1”, shifts it 1bit to the left 01110010 (2nd time) Polynomial 00000111 XOR 01110101 Step (4): Repeat step (3) 6 times. Shift 1bit to the left 11101010 (3rd time) If MSB of the above data is “1”, shifts it 1 bit to the left 11010100 (4th time) Polynomial 00000111 XOR 11010011 If MSB of the above data is “1”, shifts it 1 bit to the left 10100110 (5th time) Polynomial 00000111 XOR 10100001 If MSB of the above data is “1”, shifts it 1 bit to the left 01000010 (6th time) Polynomial 00000111 XOR 01000101 Shift 1bit to the left 10001010 (7th time) If MSB of the above data is “1”, shifts it 1 bit to the left 00010100 (8th time) Polynomial 00000111 XOR 00010011 (0x13) Step (5) The result (4) 00010011 (0x13) Middle byte of writing data 00010000 (0x10) XOR 00000011 Step (6) Shift 1bit to the left 00000110 (1st time) Step (7) Shift 1bit to the left 00001100 (2nd time)
  • 47 - Ver.1.1 Step (8): Repeat step (7) 6 times. Shift 1bit to the left 00011000 (3rd time) Shift 1bit to the left 00110000 (4th time) Shift 1bit to the left 01100000 (5th time) Shift 1bit to the left 11000000 (6th time) If MSB of the data is “1”, shifts it 1 bit to the left 10000000 (7th time) Polynomial 00000111 XOR 10000111 If MSB of the data is “1”, shifts it 1 bit to the left 00001110 (8th time) Polynomial 00000111 XOR 00001001 (0x09) Step (9) The result (8) 00001001 (0x09) LSB byte of writing data 00010010 (0x12) XOR 00011011 Step (10) Shift 1bit to the left 00110110 (1st time) Step (11) Shift 1bit to the left 01101100 (2nd time) Step (12): Repeat step (11) 6 times. Shift 1bit to the left 11011000 (3rd time) If MSB of the data is “1”, shifts it 1 bit to the left 10110000 (4th time) Polynomial 00000111 XOR 10110111 If MSB of the data is “1”, shifts it 1 bit to the left 01101110 (5th time) Polynomial 00000111 XOR 01101001 Shift 1bit to the left 11010010 (6th time) If MSB of the data is “1”, shifts it 1 bit to the left 10100100 (7th time) Polynomial 00000111 XOR 10100011 If MSB of the data is “1”, shifts it 1 bit to the left 01000110 (8th time) Polynomial 00000111 XOR 01000001 (0x41)
  • 48 - Ver.1.1 The calculation result is “0x41”. You need add error check byte 0x41 (01000001) with CRC8 mode, if writing data is “0x201012”. The calculation result is changed because of initial data. Initial data is 1 byte (8bits), so there are 256 calculation results.
  • 49 - Ver.1.1 In fact, CPU program calculates error check byte with CRC8. Initial value is changed as below, error check byte changes. ・ Initial value: 0x00 → error check byte: 0x6A ・ Initial value: 0x80 → error check byte: 0x61 #include <stdio.h> unsigned char crc8_gen( const unsigned char *buffer, size_t size){ const unsigned char polynomial = 0x07; /* x^8 + x^2 + x + 1 */ unsigned char crc = 0xFF; /* CRC initial value = 0xFF */ unsigned char data; int bit_count; size_t i=0; for ( ; i < size; i++) { data = crc ^ *buffer++; for ( bit_count = 0; bit_count < 8; bit_count++ ){ data <<= 1; data ^= polynomial; } else { data <<= 1; crc =data; return crc; int main () { unsigned char buffer[3]; unsigned char crc8; /* Example: Write 0x1012 to IEXCONF Register. Command 0x201012 buffer[0] = 0x20; /* Command Byte ( Address=2, Write) */ buffer[1] = 0x10; /* Write Data MS Byte */ buffer[2] = 0x12; /* Write Data LS Byte */ crc8 =crc8_gen( buffer, 3 ); printf( "CRC8 = 0x%02X¥n", crc8 ); /* Result : CRC8 = 0x41 */ return 0;
  • 50 - Ver.1.1 Check Sum mode The error check byte added in Check Sum mode is calculated by the following procedure. In case data is 3 byte, calculating as below. Step Description (1) Adding MSB byte, Middle byte and LSB byte of the data. Overflow is ignored. MSB: Most Significant Bit, LSB: Least Significant Bit) (2) The bits of result (1) inverted (1’s complement) is error check byte. The calculation method is shown as below. The below is considered as the calculation method when the writing data is “0x201012”. (Register Address is set to “0x2”, and writing data is set to “0x1012” in the IEXCONF register.) Writing data: 00100000 00010000 00010010 (0x201012) Step (1) MSB byte 00100000 (0x20) Middle byte 00010000 (0x10) LSB byte 00010010 (0x12) Addition result 01000010 (0x42) Step (2) The result of step (1) 01000010 (0x42) 1’ complement 10111101 (0xBD) The calculation result is “0xBD”. You need add error check byte (0xBD) with Check Sum mode, if writing data is “0x201012”.
  • 51 - Ver.1.1 SPI reset command Transferring SDI=1 continuously for 39 bits after SDI=0 resets the chip. In normal operation, since there is "0" in the ZERO [1: 0] bits of the SPI command byte, SDI=1 never becomes 39 consecutive bits. Wait at least 400nsec after reset and transfer the command byte of operation start. 400nsec is the minimum required for internal startup time. SPI reset command SPI communication example < Single conversion > This is an example of communication with the PGA gain setting implemented. (Processing in the shortest time) Single conversion example STEP DETAILS (1) Specify the address "0x0" of the CTRL register. (2) Specify single conversion "0x2" (= MODE). (3) Performs single conversion. (Conversion time + setup time + data correction time (= 1 / DR + Ts + Tcal)) (4) Specify the ADCDATA register (0x1). (5) Read the conversion data (ADCDATA register). The table below shows the time when CLKDIV = 0 and the operation clock of SPI is 5 Mbps. It is understood that the time of SPI communication << conversion time. OSR Conversion time (1/DR+Ts+Tcal ) [µsec] SPI communication time 512 1255 8 (= 1/(5[Mbit/s]) x 5[byte] x 8[bit/byte]) 256 640 128 333 64 180 SCK SDI 1 39 Twrst >400nsec A[3] Reset Command Byte Transfer SCK SDI SDO/RDYB=RDYB RDYB=1 ADCDATA[15:0]SDO/RDYB RDYB=0 (1) (4)(3) (5)(2) Conversion End Command Byte ( 0x00 ) CTRL Write Write Data ( 0x02 ) Single Conversion Start MODE = 0x2 Command Byte ( 0x18 ) ADCDATA Read Data Conversion
  • 52 - Ver.1.1 < Continuous conversion > Continuous conversion example STEP DETAILS (1) Specify the address "0x0" of the CTRL register and specify continuous conversion "0x3" (= MODE). (2) Perform continuous conversion (first time). After conversion, SDO / RDYB changes from "1" to "0". (3) Specify the address "0x1" of the ADCDATA register. SDO / RDYB changes from "0" to "1" when conversion data (ADCDATA register) is read. (4) Perform continuous conversion (second time). After conversion, SDO / RDYB changes from "1" to "0". (5) Specify the address "0x1" of the ADCDATA register. SDO / RDYB changes from "0" to "1" when conversion data (ADCDATA register) is read. (6) Perform continuous conversion (third time). After conversion, SDO / RDYB changes from "1" to "0". (7) : SDO / RDYB is kept "0" when reading the third conversion result is not performed. If reading is not performed, it operates as follows. (a) SDO / RDYB changes from "0" to "1" when the fourth AD conversion before data correction ends. (b) After the data correction time (Tcal), SDO / RDYB changes from "1" to "0". At the point (a) above, the third conversion data is discarded. If conversion data (ADCDATA register) is not read before the next (a) comes, the fourth data is also discarded. In order to read data safely, it is necessary to read the conversion data before (a) comes. SCK SDI SDO/RDYB=RDYB SDO/RDYB RDYB=0 ADCDATA[15:0]RDYB=1 Tcal SDO/RDYB=RDYB SDO/RDYB=RDYB RDYB=0 ADCDATA[15:0] 1st Conversion End Command Byte ( 0x00 ) CTRL Write Write Data ( 0x03 ) Continuous Conversion Start MODE = 0x3 Command Byte ( 0x18 ) ADCDATA Read 2nd Conversion End 3rd Conversion End 4th Conversion End Command Byte(0x18) ADCDATA Read
  • 53 - Ver.1.1 ■ MARKING SPECIFICATION (SSOP-16-BD) (1)(2)(3)(4)(5)(6)(7) Product Code Refer to Part Marking List (8) to (12) Control Number Part Marking List (SSOP-16-BD) Product Name (1) (2) (3) (4) (5) (6) (7) NA2200BDAE2S A 2 2 0 0 A S NOTICE There can be variation in the marking when different AOI (Automated Optical Inspection) equipment is used. In the case of recognizing the marking characteristic with AOI, please contact our sales or distributor before attempting to use AOI. (3) (10) (9) (11) (12) (7) (8) 1Pin

Package Information

SSOP-16-BD PI-SSOP-16-BD-E-A ■ PACKAGE DIMENSIONS UNIT: mm 0.5±0.2 0.15 +0.1 -0.05 0~10° 5.0 +0.3 -0.1 A 4.4±0.2 6.4±0.3 B 0.65

0.37 MAX

S 0.1±0.1 1.15±0.1 0.1 S 0.22±0.1 0.1 M S AB ■ EXAMPLE OF SOLDER PADS DIMENSIONS 1.0 0.35 0.65 4.55 5.9

SSOP-16-BD PI-SSOP-16-BD-E-A ■ PACKING SPEC UNIT: mm (1) Taping dimensions / Insert direction 5.4 1.75±0.15.5±0.05 12.0±0.3 0.3±0.05 2.2 Insert direction (E2) (2) Taping state Feed direction Sealing with covering tape Devices 2,000pcs/reel Leader part more than 550mm Trailer part more than 160mm

SSOP-16-BD PI-SSOP-16-BD-E-A (3) Reel dimensions 17.4±1 13.4±1 254±2 100±1 2±0.5 13±0.221±0.8 (4) Peeling strength Peeling strength of cover tape ・Peeling angle 165 to 180°degrees to the taped surface. ・Peeling speed 300mm/min ・Peeling strength 0.1 to 1.3N 1 6 5t o1 8 0 ° Direction to pull Feed direction Carrier tape Cover tape

SSOP-16-BD PI-SSOP-16-BD-E-A (5) Packing state Box size: 266×263×28 <Label> Product Name, Quantity, Lot No., Mark ■ HEAT-RESISTANCE PROFILES Reflow profile 3℃/s MAX. 217℃ 200℃ 150℃ 255℃ 260℃ MAX. 30s MAX. 6℃/s MAX. 60-120s 60-150s Time(s) Package Surface Temperature(℃)

■ REVISION HISTORY Date Revision Changes May 23, 2024 Ver. 1.0 Initial release Datasheet 2025/06/25 Ver. 1.1 Analog to Digital Converter -> Analog to Digital Converter(ADC) Package height correction Added note about NC terminals Order information: Quantity/reel -> Quantity

  1. The products and the product specifications described in this document are subject to change or discontinuation of production without notice for reasons such as improvement. Therefore, before deciding to use the products, please refer to our sales representatives for the latest information thereon. 2. The materials in this document may not be copied or otherwise reproduced in whole or in part without the prior written consent of us. 3. This product and any technical information relating thereto are subject to complementary export controls (so- called KNOW controls) under the Foreign Exchange and Foreign Trade Law, and related politics ministerial ordinance of the law. (Note that the complementary export controls are inapplicable to any application-specific products, except rockets and pilotless aircraft, that are insusceptible to design or program changes.) Accordingly, when exporting or carrying abroad this product, follow the Foreign Exchange and Foreign Trade Control Law and its related regulations with respect to the complementary export controls. 4. The technical information described in this document shows typical characteristics and example application circuits for the products. The release of such information is not to be construed as a warranty of or a grant of license under our or any third party's intellectual property rights or any other rights. 5. The products listed in this document are intended and designed for use as general electronic components in standard applications (office equipment, telecommunication equipment, measuring instruments, consumer electronic products, amusement equipment etc.). Those customers intending to use a product in an application requiring extreme quality and reliability, for example, in a highly specific application where the failure or misoperation of the product could result in human injury or death should first contact us.
  • Aerospace Equipment
  • Equipment Used in the Deep Sea
  • Power Generator Control Equipment (nuclear, steam, hydraulic, etc.)
  • Life Maintenance Medical Equipment
  • Fire Alarms / Intruder Detectors
  • Vehicle Control Equipment (automotive, airplane, railroad, ship, etc.)
  • Various Safety Devices
  • Traffic control system
  • Combustion equipment In case your company desires to use this product for any applications other than general electronic equipment mentioned above, make sure to contact our company in advance. Note that the important requirements mentioned in this section are not applicable to cases where operation requirements such as application conditions are conf irmed by our company in writing after consultation with your company. 6. We are making our continuous effort to improve the quality and reliability of our products, but semiconductor products are likely to fail with certain probability. In order to prevent any injury to persons or damages to property resulting from such failure, customers should be careful enough to incorporate safety measures in their design, such as redundancy feature, fire containment feature and fail-safe feature. We do not assume any liability or responsibility for any loss or damage arising from misuse or inappropriate use of the products. 7. The products have been designed and tested to function within controlled environmental conditions. Do not use products under conditions that deviate from methods or applications specified in this datasheet. Failure to employ the products in the proper applications can lead to deterioration, destruction or failure of the products. We shall not be responsible for any bodily injury, fires or accident, property damage or any consequential damages resulting from misuse or misapplication of the products. 8. Quality Warranty 8-1. Quality Warranty Period In the case of a product purchased through an authorized distributor or directly from us, the warranty period for this product shall be one (1) year after delivery to your company. For defective products that occurred during this period, we will take the quality warranty measures described in section 8-2. However, if there is an agreement on the warranty period in the basic transaction agreement, quality assurance agreement, delivery specifications, etc., it shall be followed. 8-2. Quality Warranty Remedies When it has been proved defective due to manufacturing factors as a result of defect analysis by us, we will either deliver a substitute for the defective product or refund the purchase price of the defective product. Note that such delivery or refund is sole and exclusive remedies to your company for the defective product. 8-3. Remedies after Quality Warranty Period With respect to any defect of this product found after the quality warranty period, the defect will be analyzed by us. On the basis of the defect analysis results, the scope and amounts of damage shall be determined by mutual agreement of both parties. Then we will deal with upper limit in Section 8-2. This provision is not intended to limit any legal rights of your company. 9. Anti-radiation design is not implemented in the products described in this document. 10. The X-ray exposure can influence functions and characteristics of the products. Confirm the product functions and characteristics in the evaluation stage. 11. WLCSP products should be used in light shielded environments. The light exposure can influence functions and characteristics of the products under operation or storage. 12. Warning for handling Gallium and Arsenic (GaAs) products (Applying to GaAs MMIC, Photo Reflector). These products use Gallium (Ga) and Arsenic (As) which are specified as poisonous chemicals by law. For the prevention of a hazard, do not burn, destroy, or process chemically to make them as gas or power. When the product is disposed of, please follow the related regulation and do not mix this with general industrial waste or household waste. 13. Please contact our sales representati ves should you have any questions or comments concerning the products or the technical information. Official website https://www.nisshinbo-microdevices.co.jp/en/ Purchase information https://www.nisshinbo-microdevices.co.jp/en/buy/