NE134 IVO | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
Preset counter with two presets – Display 6-digits – Batch counter, totalizer – Operating mode, start count, scaling factor – programmable Connection: Incremental encoder or digital sensors – Step and trailing preset programmable – Interface RS485 – Technical data - electrical ratings Voltage supply 22...50 VAC (50/60 Hz) 12...30 VDC Power consumption 5 VA, 5 W Sensor supply AC: 24 VDC ±20 % / 100 mA DC: 9...28 VDC / 100 mA Display LCD, 7-segment display, 2-lines, backlit Number of digits 6-digits 8-digits - totalizer in 2 steps Digit height 7 mm (count) 4 mm (preset) Function Preset counter Main counter with 2 presets Batch counter with 1 preset Totalizer Count modes Adding or subtracting A-B (difference counting) A+B total (parallel counting) Up/Down A 90° B phase evaluation Counting frequency Main counter: 3 Hz, 25 Hz or 10 kHz Batch counter: approx. 20 Hz Operating modes Step preset, Trailing preset Data memory >10 years in EEPROM Reset Button, electric or automatic Keylock Yes, electric (keylock) Outputs electronic Optocoupler Outputs relay Normally open or closed, programmable Interface RS485 NE134 Technical data - mechanical design Operating temperature 0...+50 °C Storing temperature -20...+70 °C Relative humidity 80 % non-condensing E-connection Plug-in screw terminals Core cross-section 1.5 mm² Protection DIN EN 60529 IP 65 face with seal Operation / keypad Membrane with softkeys Housing type Built-in housing Dimensions W x H x L 48 x 48 x 100 mm Installation depth 100 mm Mounting Clip frame Cutout dimensions 45 x 45 mm (+0.6) Materials Housing: Makrolon 6485 (PC) Keypad: Polyester Weight approx. 150 g 1 or 2 presets, PNP, NPN or AC logic Display LCD, 6-digits, programmable Technical data - electrical ratings Standard DIN EN 61010-1 Protection class II Overvoltage category II Pollution degree 2 Emitted interference DIN EN 61000-6-4 Interference immunity DIN EN 61000-6-2 Programmable parameters Measuring units, sensor logic Operating modes Scaling factor Count mode Approvals UL/cUL, CE conform
www.baumerivo.com www.baumerivo.com Preset counters electronic www.baumerivo.com 2 Subject to modification in technic and design. Errors and omissions excepted.30/10/2008 NE134 Part number NE134. AX01 Voltage supply 1 22...50 VAC 2 85...265 VAC 3 12...30 VDC Outputs
1 Relay outputs
2 Electronic outputs
0 Without interface
1 RS485
1 or 2 presets, PNP, NPN or AC logic Display LCD, 6-digits, programmable Comparator inputs Input circuit Inputs PNP- / NPN- / AC-logic Input level Programmable Input level Low 0...2 VDC Input level High 3...40 VDC Input resistance 3 kΩ Relay outputs Output circuit Switching voltage max. 250 VAC / 110 VDC Switching current max. 1 A Switching capacity max. 150 VA / 30 W Relay responding time 5 ms Electronical outputs Output circuit Optocoupler short-circuit proof Switching voltage max. 40 V Switching current max. 25 mA Trigger level Voltage supply Signal input A B Control input Output A 90°B Totalizer Interface RS485 Batch counter with or without preset Main counter with 1 or 2 presets start count scaling factor T,R- T,R+ Sensor supply Block circuit diagram Dimensions 60.8 44.7 100 1-6 Relay outputs Electronic outputs Supply voltage T,R+ 15 14 13 12 11 10 98 7 P2 P1 54 32 1 T,R- +24V T,R+ B A RS485 Sensor- supply Control input Signal input terminal - terminal/ max. 265 V - terminal Supply voltage T,R+ 15 14 13 12 11 10 98 7 P2 P1 54 32 1 T,R- +24V T,R+ B A RS485 Sensor supply Control input Signal input terminal - terminal / max. 265 V - terminal Outputs Outputs Connection diagram Accessories Adaptor plates (page %S) Z 118.033 Adaptor plate for screw mount, face 60 x 75 mm Z 118.034 Adaptor plate for clip mount, face 53.2 x 53.2 mm Z 118.035 Adaptor plate for clip mount, face 60 x 75 mm